29
Status and Design Features of the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center [email protected] Co-authors: Kim D. Otten, Vicente J. Suarez, Dzu K. Le NASA Glenn Research Center May 3 rd 6 th 2010

Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center [email protected]

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Status and Design Features

of the new NASA GRC

Mechanical Vibration Facility (MVF)

Presented by: Kim D. Otten

NASA Glenn Research Center

[email protected]

Co-authors: Kim D. Otten,

Vicente J. Suarez, Dzu K. Le

NASA Glenn Research Center

May 3rd – 6th 2010

Page 2: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

2

Test Facility Overview

• Environmental test capability for NASA’s future space programs is being developed at the Space Power Facility (SPF) at the NASA Glenn Plum Brook Station in Sandusky, OH.

• SPF will provide one-stop shopping for a wide variety of space environmental testing.

•The focus of this presentation is the status and design of the Mechanical Vibration Facility (MVF).

Environmental Facility Capability:

• Mechanical Vibration

• Acoustic

• Modal Floor

• Thermal-Vacuum

Page 3: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

3

Space Power Facility – Sandusky OH

Disassembly Bay

Area

Page 4: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Provide and Support Future NASA Testing

Acoustic

Testing

Sine

Vibration

and Modal

Testing

Thermal

Vacuum

Testing

4

Page 5: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Benham Corporation is Prime Contractor

*

* MVF Suppliers:

TEAM: Actuators &

Spherical Couplings,

Pad Bearings, etc.

Data Physics:

Vibration Control

System

5

Page 6: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

MVF Primary Objectives

• Benham is tasked to design and deliver a Mechanical Vibration

Facility (MVF):

– Capable of base shaking a 75-ft, 75,000 lb, 23.67-ft CG, 18-ft

diameter test article with single-axis sine excitation to 1.25-g

vertically and 1.0-g horizontally from 5-to-150-Hz without

repositioning the test article.

– Capable of fixed-base modal testing the same test article (71-ft

tall)

6

Page 7: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

7

Mechanical Vibration Facility (MVF)

20' Modal

Floor

“The MVF requirements make it a higher capacity facility than any in existence - 50% greater payload capacity, 25% greater vertical force capacity and 50% higher frequency range than HYDRA (ESTEC), the current largest capacity (aerospace) vibration system.”

Vertical Shaker &

Spherical Couplings

North

Vibration Table

Horizontal

Shaker

Note: MVF is capable 480,000 lbf vertically, and 170,000 lbf in each lateral direction.

Page 8: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

8

Mechanical Vibration Subsystem – Close-up

Horizontal Actuator Assembly (HAA)

• Horizontal Actuator Drives Table Horizontally

• Composed of Horiz. Actuator & Pad Bearing

• Pad Bearings Guides Table Vertically ( Horiz. Actuator Mounting Pedestals Not Shown)

Vertical Actuator Assembly (VAA)

• Vertical Actuators Drives Vertical Vibration

• Composed of Vertical Actuator & Spherical Coupling

• Spherical Couplings Permits Horizontal Motion

• Spherical Coupling Restrains Overturning Moments(With Vertical Actuators Locked Down)

Page 9: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

9

MVF with Vibration Table Removed

Horizontal Actuators

Assemblies (4)

Access under the

Vibration Table

Table Supports (4)

Vertical Actuator

Assemblies (16)

Air Bag

stands (4)

Page 10: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

MVF Operation – Overview

10

• Vertical Shake

• Horizontal Shake

• Spherical Coupling

Vertical Motion Mov ie.wmv

Sherical Coupling-Double Animation WMF.wmv

BIAXIAL PLAN VIEW Y MOTION.wmv

Movies

Note: MVF is capable of 6-DOF, but the MVF Controller would require modification

Page 11: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

11

Testing has been performed for Vertical Actuators

Page 12: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Shale

2’ 2”

10’ 10”

19’ Base for MVF Horizontal Actuators

SPF Finished Floor

4-ft Concrete

MVF Lifts (Concrete Pours)

Pour #1

Pour #2

Pour #3

Pour #4

Pour #5 (8”)

Bottom of MVF Pit

Not to Scale

4” Mud Mat (min)

12

Page 13: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

13

December 2008 - Construction BaselineStarting Point: 4” Mud Mat on Floor of 19-ft deep pit, and Shotcrete/Anchored Vertical Walls

Page 14: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

14

December 2008 – Rock Bolt Driller

Page 15: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

15

April 2009 – Rebar for Pour #1

North

Wall

Page 16: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

16

June 2009 – Pour #1

North

Wall

Page 17: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

17

June 2009 - Pour #1 – Complete

North

Page 18: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

18

June 2009 - Pour #2 – Rebar & Formwork

North

Wall

Page 19: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

19

June 2009 - Pour #2 – Complete

North

Wall

Page 20: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

20

July 2009 - Pour #3 – Formwork

North Wall

Page 21: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

21

August 2009 - Pour #4 – Rebar

North Wall

Page 22: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

22

September 2009 – Pour #4 Forms Removed

North

Wall

Page 23: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

23

October 2009 - Tensioning Rock Bolts

90 of 106 Rock Anchors Tensioned to 208,000 lbs

Remaining 16 will be Tensioned when Horizontal Pedestals Installed

Page 24: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

24

November 2009 – Pour #5 Complete

North Wall

Page 25: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Summary: Started w/ Empty 19-ft pit in

December 2008

25

North

Wall

Page 26: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

December 2009

26

Concrete : 4.4 million lbs (1038 cu yds)

Rebar : 11.2 miles (79 tons)

Rock Anchors: 20.4 million lbf (106)

Tension Anchors: 11.1 million lbf (178)

North Wall

Page 27: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Mechanical Vibration Facility

Modal Plate

Area

32-ft Diam

Footprint

18-ft Diam.

Footprint

• Will be able to accommodate single-axis sine excitation for 75,000 lb test

article with 23.67-ft CG and 18-ft diameter to 1.25-g vertically and 1.0-g

lateral from 5 to 150 Hz without rotating test article.

• Space and the MVF reaction mass is designed to accommodate even

larger diameter test articles.

27

Page 28: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Looking Forward

For MVF Testing, Contact

Mr. Jerry Carek,

Phone: (419)-621-3219, [email protected]

• Vertical Actuators – Completed

• Spherical Couplings – Completed

• Horizontal Actuators Complete – June 2010

• MVF Table Complete – June 2010

• MVF Assembly Complete – August 2010

• Benham Verification of MVF Complete – April 2011

• NASA Integrated System Testing – Summer 2011

• Available for Testing – Fall 2011

Page 29: Status and Design Features of the new ... - Team Corporationof the new NASA GRC Mechanical Vibration Facility (MVF) Presented by: Kim D. Otten NASA Glenn Research Center Kim.D.Otten@nasa.gov

Contact Information:

Kim Otten

NASA Glenn Research Center

[email protected]

29