37
Steadfast Home Inspection www.steadfasthomeinspection.com 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal Kopeikin 05/15/2019 Prepared by: Kyle Gates Owner / Inspector

Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

  • Upload
    others

  • View
    6

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Steadfast Home Inspection

www.steadfasthomeinspection.com

805-295-8009

HOME INSPECTION REPORT

6892 Trigo Rd

Goleta, CA 93117 Prepared for:

Ann Marie & Hal Kopeikin

05/15/2019

Prepared by:

Kyle Gates

Owner / Inspector

Page 2: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Table of Contents

Definitions 2

General Information 2

Structure 3

Exterior 4

Lots and Grounds 5

Roof 7

Kitchen 9

Living Space 11

Bedrooms 14

Bathrooms 18

Laundry 21

Parking 22

Attic 23

Electrical 25

Plumbing 26

Heating System 28

Summary 30

Steadfast Home Inspection, LLC 1 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 3: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

DefinitionsNOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

General Information

Property Information

Property Address: 6892 Trigo Rd

City: Goleta State: CA Zip: 93117

Client Information

Client Name: Ann Marie & Hal Kopeikin

Inspection Company

Inspector Name Kyle Gates

Company Name Steadfast Home Inspection, LLC

Inspector Phone: 805-295-8009

Inspector Email: [email protected]

Conditions

Others Present: None Property Status: Occupied

Inspection Date: 05/15/2019

Electricity: On Gas: On Water: On

Weather: Cloudy Soil Conditions: Dry

Water Source: City How Verified: Visual Inspection

Sewage Disposal: City How Verified: Visual Inspection

Health/Safety Asbestos: Asbestos material observed - Homes built prior to 1978 may be built with materials known

to contain asbestos. Products like acoustic ceiling spray texture ("popcorn" or "cottage cheese"

ceilings), tiles, vent flues, and linoleum are some examples of materials that may contain asbestos. In

many cases it is safe to leave these materials in the home, if they are in places where they will not be

disturbed. If the material must be removed (as in the case of renovation or remodel), it should be

handled and disposed of in accordance with EPA guidelines.

Health/Safety Lead Paint: Lead paint suspected based on age - Homes built prior to 1978 may contain lead paint.

Lead paint can deteriorate into lead dust that can be harmful when inhaled, especially by the elderly or

young children. While lead paint can be "encapsulated" by painting over it with non-lead paint, chips of

paint may still be dangerous. Painted wooden windows are also sources of lead dust in a home as the

abrasive action of opening & closing makes dust more likely. An environmental services company can

determine if lead paint is present.

Steadfast Home Inspection, LLC 2 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 4: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

StructureVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items. Inspector is not required to enter areas that he/she deems to be dangerous, for any reason.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

1. Estimated Age: 1969 Entrance Faces: South

2. Building Type: Single Family Garage: Attached, Converted

3. Space Below Grade: None

4. Acceptable Construction: Wood frame

5. Acceptable Foundation: Slab on Grade

6. Acceptable Differential Movement: No movement or displacement observed

7. Acceptable Slab: Poured slab

8. Not Inspected Subfloor: Due to the construction of the home, no areas of subfloor were accessible for

inspection.

Steadfast Home Inspection, LLC 3 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 5: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

ExteriorVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Front Exterior Surface

1. Defective Type: Wood siding - Siding had wood decay, which should be repaired or replaced to reduce

chances of further decay or water intrusion.

Main Exterior Surface

2. Acceptable Type: Stucco

3. Acceptable Fascia: Wood

4. Acceptable Soffit: Wood

5. Acceptable Door Bell: Hard wired

6. Acceptable Exterior Electrical: GFCI 120 VAC

7. Acceptable Exterior Lighting: Surface mount

8. Acceptable Hose Bib: Rotary

Steadfast Home Inspection, LLC 4 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 6: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Lots and GroundsVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

1. Marginal Driveway: Concrete - Driveway had cracking that appeared typical and should be monitored. If

condition worsens, correction may be necessary in order to ensure stability of driveway.

2. Marginal Walks: Concrete - Sidewalk had cracking that appeared typical and should be monitored. If

condition worsens, correction may be necessary in order to ensure stability of walkway.

3. Defective Patio: Concrete - Patio was cracked throughout. Recommend resurfacing or replacement to help

prevent further deterioration and tripping hazards.

4. Acceptable Deck: Painted wood

5. Acceptable Grading: Flat

6. Acceptable Swale: No problem observed

7. Acceptable Ground Cover: Grass

8. Marginal Vegetation: Trees - Trees planted within 10 feet of the foundation could cause damage.

Recommend removal of any trees within this distance.

Steadfast Home Inspection, LLC 5 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 7: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Lots and Grounds (Continued)9. Defective Fence: Wood - Wooden fence was in contact with the dirt below, which can lead to decay and

pest infestation. Only treated wood should be in contact with the dirt. Dirt should be removed from

the bottom of the fence.

10. Not Inspected Lawn Sprinklers: The function of yard sprinklers are beyond the scope of this inspection. For

further evaluation, contact a qualified landscape maintenance contractor.

Steadfast Home Inspection, LLC 6 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 8: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

RoofVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items. Inspector is not required to enter areas that he/she deems to be dangerous, for any reason.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Main Roof Surface

1. Method of Inspection: On roof

2. Acceptable Unable to Inspect: 0%

3. Marginal Material: Asphalt shingle - Shingles throughout the roof had missing granules. There were torn

and cracked shingles in various places. While no evidence of current leakage was observed, leaks

may develop without warning.

Roof had exposed fasteners that could be an entry point for water. An appropriate sealant should

be applied over the fasteners. This is a regular maintenance issue that should be performed as

needed.

Exposed fastener Exposed fasteners

4. Type: Hip

5. Approx Age: 10+ years

6. Acceptable Valleys: Asphalt shingle

7. Acceptable Skylights: Tube-type

8. Acceptable Plumbing Vents: ABS

Steadfast Home Inspection, LLC 7 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 9: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Roof (Continued)9. Health/Safety Electrical Mast: Mast with tie back at roof - Drip loops were not of adequate length to keep water

from running down the mast to the electrical service. Drip loops should be repaired for occupants'

safety to help prevent a possible service outage.

Drip loop too high

10. Defective Gutters: Partial, Plastic - Some gutters were present. The addition of gutters would help ensure

that rainwater gets transported away from the building structure and foundation, improving the life

of both.

11. Marginal Gutters: Partial, Plastic - Gutters had debris in them and should be cleaned in order to function

properly.

12. Defective Downspouts: None present - Downspouts were not installed. Recommend adding downspouts

to guide water down from the roof, toward extended leaders and/or a drainage system that can

move water away from any structures.

Steadfast Home Inspection, LLC 8 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 10: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

KitchenVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Main Kitchen

1. Acceptable Cooking Appliance: Kenmore

2. Acceptable Ventilator: Microwave integrated, Kenmore

3. Acceptable Disposal: In-Sinkerator, 3/4 HP

4. Acceptable Dishwasher: Kenmore

5. Air Gap Present? No Dishwasher did not have an Air Gap installed. A physical air gap helps protect the public

water supply in case of a loss of pressure. Although required by the local building code, many people opt to go

without. If this is the case, a high-loop of the dishwasher drain line under the counter is highly recommended (or

some other means of backflow prevention).

6. Acceptable Refrigerator: Maytag

7. Acceptable Refrigerator: Frigidaire

8. Acceptable Microwave: Kenmore

9. Acceptable Sink: Stainless steel, Double basin

10. Acceptable Plumbing/Fixtures: Single-hole faucet, Brass trap

11. Defective Counter Tops: Tile - Grout was damaged or missing and should be repaired. Damaged grout

could allow tiles to move or water to move off the counter into the cabinets below.

12. Acceptable Cabinets: Wood and laminate

13. Acceptable Walls: Drywall / sheetrock

Steadfast Home Inspection, LLC 9 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 11: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Kitchen (Continued)14. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

15. Acceptable Ceiling: Drywall / sheetrock

16. Acceptable Floor: Wood

17. Defective Door: Vinyl sliding, Dual paned - Door lock was not functional and should be repaired.

18. Marginal Door: Vinyl sliding, Dual paned - Screen was torn or damaged.

19. Acceptable Windows: Tube-type skylight

20. Acceptable Electrical: GFCI 120VAC

21. Acceptable Lighting: Lighted skylight, Recessed lights

22. Acceptable HVAC Source: Heating system register

Steadfast Home Inspection, LLC 10 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 12: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Living SpaceVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Living Room Living Space

1. Acceptable Walls: Drywall / sheetrock

2. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

3. Acceptable Floor: Tile, Vinyl floor covering

4. Acceptable Door: Wood and glass

5. Acceptable Windows: Aluminum sliding, Single paned

6. Acceptable Electrical: 120VAC

7. Acceptable HVAC Source: Heating system register

Sun Room Living Space

8. Acceptable Walls: Vinyl / Synthetic

9. Acceptable Ceiling: Vinyl / Synthetic

10. Acceptable Floor: Concrete

Steadfast Home Inspection, LLC 11 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 13: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Living Space (Continued)11. Marginal Door: Vinyl sliding, Dual paned - Screen was torn or damaged.

12. Acceptable Windows: Vinyl sliding, Single paned

13. Acceptable Electrical: GFCI 120VAC

14. Acceptable HVAC Source: None present

15. Acceptable Smoke Alarm: Battery-operated

Hallway Living Space

16. Acceptable Walls: Drywall / sheetrock

17. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

18. Acceptable Floor: Vinyl floor covering

19. Acceptable Windows: Tube-type skylight

20. Acceptable Electrical: 120VAC

21. Acceptable Lighting: Lighted skylight, 3-way switch

Steadfast Home Inspection, LLC 12 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 14: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Living Space (Continued)22. Acceptable Smoke Alarm: Battery-operated

23. Acceptable CO Alarm: Combination Smoke/CO

Steadfast Home Inspection, LLC 13 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 15: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

BedroomsVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Master Bedroom

1. Acceptable Walls: Drywall / sheetrock

2. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

3. Acceptable Floor: Vinyl floor covering

4. Acceptable Door: Hollow wood

5. Acceptable Windows: Aluminum sliding, Single paned

6. Acceptable Windows: Stained Glass

7. Acceptable Electrical: 120VAC

8. Acceptable Lighting: Switched receptacle

9. Marginal Closet: Single - Closet doors were missing or not installed.

10. Not Inspected HVAC Source: Window A/C Unit - Window A/C unit not inspected as it is not a system of the

home. Window units are typically considered personal property and not transferred with the home.

11. Marginal HVAC Source: Heating system register - Little or no air flow was felt from the vent while the

HVAC system was in operation. Recommend further evaluation by a qualified HVAC contractor.

Steadfast Home Inspection, LLC 14 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 16: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Bedrooms (Continued)12. Acceptable Smoke Alarm: Battery-operated

Second Bedroom

13. Acceptable Walls: Drywall / sheetrock

14. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

15. Acceptable Floor: Vinyl floor covering

16. Acceptable Door: Hollow wood

17. Marginal Windows: Aluminum sliding, Single paned - Window screen was loose and should be re-secured.

18. Acceptable Electrical: 120VAC

19. Acceptable Lighting: Switched receptacle

20. Marginal Closet: Single - Closet doors were missing or not installed.

21. Marginal HVAC Source: Heating system register - Little or no air flow was felt from the vent while the

HVAC system was in operation. Recommend further evaluation by a qualified HVAC contractor.

22. Acceptable Smoke Alarm: Battery-operated

Third Bedroom

Steadfast Home Inspection, LLC 15 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 17: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Bedrooms (Continued)23. Acceptable Walls: Drywall / sheetrock

24. Health/Safety Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust

is a hazard to occupants and should be avoided. Disposal should be done in accordance with EPA

recommendations.

25. Acceptable Floor: Vinyl floor covering

26. Acceptable Door: Hollow wood

27. Acceptable Windows: Aluminum sliding, Single paned

28. Acceptable Electrical: 120VAC

29. Acceptable Lighting: Switched receptacle

30. Marginal Closet: Single - Closet doors were missing or not installed.

31. Acceptable HVAC Source: Heating system register

32. Acceptable Smoke Alarm: Battery-operated

Fourth Bedroom

33. Acceptable Walls: Drywall / sheetrock

34. Acceptable Ceiling: Drywall / sheetrock

35. Acceptable Floor: Carpet

36. Acceptable Door: Solid wood

Steadfast Home Inspection, LLC 16 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 18: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Bedrooms (Continued)37. Marginal Windows: Aluminum sliding, Single paned - Window screen was torn or damaged.

38. Acceptable Electrical: 120VAC

39. Acceptable Lighting: Ceiling mounted

40. Marginal Closet: Single - Closet doors were missing or not installed.

41. Acceptable Smoke Alarm: Battery-operated

Steadfast Home Inspection, LLC 17 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 19: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

BathroomsVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Master Bathroom

1. Acceptable Walls: Drywall / sheetrock

2. Acceptable Ceiling: Drywall / sheetrock

3. Defective Floor: Tile - Grout between tile is damaged or missing. Grout holds tile in place and helps seal

against moisture intrusion and should be replaced or repaired as necessary. This is a part of

ongoing maintenance.

4. Acceptable Door: Hollow wood

5. Acceptable Windows: Aluminum sliding, Single paned

6. Health/Safety Electrical: 120VAC - Current practice calls for GFCI outlets in any areas that may get wet, such

as kitchens and baths, to reduce risk of shocks. Outlets in this room were not GFCI protected and

protective devices should be installed.

7. Acceptable Lighting: Ceiling mounted

Steadfast Home Inspection, LLC 18 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 20: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Bathrooms (Continued)8. Acceptable Counter/Cabinet: Tiled, Wood and composite

9. Marginal Sink/Basin: Porcelain coated - Sink stopper did not function fully; water slowly drained when

closed.

10. Acceptable Faucets/Traps: Center-set faucet, Brass trap

11. Acceptable Shower/Surround: Fiberglass pan and fiberglass surround

12. Defective Toilet: American Standard - The toilet was loose at the floor, which can lead to a leak or seepage.

Recommend a new wax ring be installed when repaired.

13. Acceptable HVAC Source: Heating system register

14. Defective Ventilation: Window only - Recommend installation of ventilation fan to help prevent excessive

moisture.

Hallway Bathroom

15. Acceptable Walls: Drywall / sheetrock, Wood

16. Acceptable Ceiling: Drywall / sheetrock

17. Acceptable Floor: Tile

18. Acceptable Door: Hollow wood

19. Acceptable Windows: Skylight

20. Health/Safety Electrical: 120VAC - Current practice calls for GFCI outlets in any areas that may get wet, such

as kitchens and baths, to reduce risk of shocks. Outlets in this room were not GFCI protected and

protective devices should be installed.

21. Acceptable Lighting: Lighted skylight

Steadfast Home Inspection, LLC 19 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 21: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Bathrooms (Continued)22. Acceptable Sink/Basin: Wall-mounted, Porcelain coated

23. Acceptable Faucets/Traps: Wide spread faucet, Brass trap

24. Defective Tub/Surround: Porcelain tub, Stone surround

25. Defective Toilet: Kohler - The toilet was loose at the floor, which can lead to a leak or seepage. Recommend

a new wax ring be installed when repaired.

26. Acceptable HVAC Source: Heating system register

27. Acceptable Ventilation: Electric ventilation fan

Steadfast Home Inspection, LLC 20 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 22: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

LaundryVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Garage Laundry Room/Area

1. Not Inspected Washer: LG - The Washer was not inspected as it is not considered an 'installed' component in

the home. Washing machines have many settings and they should be inspected by an appliance

repair specialist to ensure they are good working order before use.

2. Not Inspected Dryer: Maytag - The Dryer was not inspected as it is not considered an 'installed' component in

the home. Dryers have many settings and they should be inspected by an appliance repair

specialist to ensure they are good working order before use.

3. Health/Safety Washer Hose Bib: Rubber hoses - Washer hoses were rubber, which are more prone to bursting

that the recommended braided style. For safety, they should be replaced.

4. Health/Safety Washer and Dryer Electrical: 120 VAC - Outlet or switch was missing its cover. Cover should be

installed to help reduce risk of electrocution.

5. Acceptable Dryer Gas Line: Cast iron

6. Acceptable Washer Drain: Wall mounted drain

7. Acceptable Walls: Exposed framing

8. Acceptable Ceiling: Exposed framing

9. Acceptable Floors: Concrete

10. Acceptable Door: Hollow wood

11. Health/Safety Electrical: 120VAC - Electrical outlets in Laundry areas should be GFCI-protected for safety.

Recommend installation of GFCI-protection devices, whether receptacles or breakers to protect all

Laundry outlets.

12. Acceptable Lighting: Ceiling mounted

Steadfast Home Inspection, LLC 21 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 23: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

ParkingVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Main Garage

1. Type of Structure: Attached Car Spaces: None (Converted)

2. Defective Garage Doors: Metal - Garage door weather-stripping did not make solid contact with the ground,

which could create an entry point for water or pests. Recommend correction.

3. Marginal Garage Doors: Metal - Door panels have small to medium dents that do not affect the operation

of the door.

4. Acceptable Door Operation: Manual

5. Acceptable Walls: Exposed framing

6. Acceptable Ceiling: Exposed framing

7. Not Inspected Floor/Foundation: Poured concrete - Floor was largely unavailable for inspection due to

occupants' belongings.

Steadfast Home Inspection, LLC 22 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 24: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

AtticVisual inspection is limited to accessible areas. Inspector is not required to move furniture, rugs, access panels, or belongings. Some

defects may be hidden by these items. Inspector is not required to enter areas that he/she deems to be dangerous, for any reason.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Main Attic

1. Method of Inspection: In the attic

2. Acceptable Unable to Inspect: 0%

3. Acceptable Roof Framing: 2x8 Rafter

4. Acceptable Sheathing: Dimensional wood

5. Acceptable Ventilation: Soffit vents, Roof vents

6. Acceptable Insulation: Fiberglass, Batts

7. Acceptable Insulation Depth: <8"

8. Health/Safety Wiring/Lighting: 120 VAC - Junction box missing cover. Recommend covering to help protect

from risk of shock.

Electrical conductors had insulation worn through, exposing the copper conductors. Recommend

replacement or repair.

Exposed conductors

9. Health/Safety Signs of Pests: Signs of rodents - Recommend further evaluation by a qualified pest inspector.

10. Defective Signs of Pests: Wood destroying organisms - Recommend further evaluation by a qualified pest

inspector.

Steadfast Home Inspection, LLC 23 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 25: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Attic (Continued)Signs of Pests: (continued)

Steadfast Home Inspection, LLC 24 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 26: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

ElectricalInspection of electrical components is limited to those that are readily accessible and using normal operating controls. Wiring in walls

is beyond the scope of this inspection.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

1. Service Amps: 100 Volts: 120/240 VAC

2. Acceptable Service: Copper

3. Acceptable 120 VAC Branch Circuits: Copper

4. Acceptable 240 VAC Branch Circuits: Copper

5. Acceptable Aluminum Wiring: None observed

6. Acceptable Conductor Type: Non-metallic sheathed cable (Romex)

7. Acceptable Ground: Not visible

8. Acceptable Smoke Alarms: 7 of 5 recommended

9. Acceptable CO Alarms: 2 of 1 recommended

Exterior Wall Electric Panel

10. Health/Safety Manufacturer: Unknown - The service panel had no dead front cover (inner cover), leaving wiring

exposed. Recommend installation for occupants' safety.

Distribution panel was lacking a legend describing each circuit in a way that is clear and

unambiguous. Recommend labeling each circuit.

11. Acceptable Main Breaker Size: 100 Amps

12. Acceptable Breakers: Copper

13. Health/Safety AFCI: None observed - No Arc-Fault Circuit Interrupter (AFCI) devices were installed in the panel.

Though not required when this home was built, AFCIs are now commonly called for at all circuits

feeding lights or receptacles in bedrooms, living rooms and hallways. They help protect against

electrical fires caused by electrical arcing both at the installed wiring in the walls and anything

plugged into the protected outlets. Recommend installation of AFCI devices.

14. Acceptable GFCI: At GFCI receptacles

15. Is the panel bonded? Yes

Steadfast Home Inspection, LLC 25 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 27: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

PlumbingInspection of plumbing components is limited to those that are readily accessible and using normal operating controls. Plumbing in

walls is beyond the scope of this inspection.

Water softeners, reverse osmosis and/or water filtration systems are beyond the scope of this inspection. For more information, it is

recommended you contact the installer and/or provider.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

1. Acceptable Water Meter: At street

2. Acceptable Main Water Shutoff: Front of house

3. Acceptable Service Line: Copper

4. Acceptable Water Lines: Copper

5. Acceptable Drain Pipes: Cast iron

6. Acceptable Service Caps: Not visible

7. Acceptable Vent Pipes: ABS

8. Acceptable Gas Meter: Back of home

9. Acceptable Main Gas Shutoff: At gas meter

Steadfast Home Inspection, LLC 26 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 28: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Plumbing (Continued)10. Acceptable Gas Service Lines: Cast iron

Garage Water Heater

11. Acceptable Water Heater Operation: Functional at time of inspection

12. Manufacturer: Rheem

13. Model Number: 22V40F1 Serial Number: RHLN 0411Z01136

14. Type: Natural gas Capacity: 40 Gallons

15. Approx. Age: 2011 Area Served: Whole house

16. Acceptable Flue Pipe: Double wall

17. Acceptable Seismic Strapping: Strapped

18. Acceptable Temperature Pressure Release Valve (TPRV): Copper

19. Acceptable Drain Tube: Pan

Steadfast Home Inspection, LLC 27 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 29: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Heating SystemIt is always recommended that the homeowner follow the manufacturer's recommendations regarding filter replacement and system

maintenance. Most manufacturers recommend annual maintenance of heating systems by qualified HVAC contractor and monthly

replacement of any disposable filters.

Portable heaters and those that were not permanently attached to the building are outside the scope of the inspection.

NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection.

Acceptable Functional with no observed signs of defect.

Defective Item is not functioning as intended and/or needs repair.

Marginal Item is either in a state of reduced functionality or near the end of its intended life.

Health/Safety Item represents a possible health or safety concern.

Not Inspected Item was unable to be inspected for reason noted in report.

Closet Heating System

1. Acceptable Heating System Operation: Functional at the time of inspection

2. Manufacturer: Guardian

3. Model Number: GGLS080B12MP11A Serial Number: W1N1480363

4. Type: Forced air Capacity: Unknown

5. Area Served: Whole house Approx. Age: 2011

6. Fuel Type: Natural gas

7. Acceptable Heat Exchanger: 4 Burner

8. Unable to Inspect: 0%

9. Defective Blower Fan/Filter: Direct drive with disposable filter - Filter is dirty and should be replaced.

Recommend following manufacturer's recommendations for changing the HVAC system filter(s).

10. Acceptable Distribution: Metal duct

11. Acceptable Draft Control: Induced, Open Chamber

12. Acceptable Flue Pipe: Double wall

13. Acceptable Controls: Safety-shut off switch

14. Acceptable Thermostats: Single, Programmable

Steadfast Home Inspection, LLC 28 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 30: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Heating System (Continued)15. Suspected Asbestos: Yes - The material insulating the duct transition boots is likely to contain asbestos.

Recommend care be taken when handling. Removal should be done in accordance with EPA guidelines.

Steadfast Home Inspection, LLC 29 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 31: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Defective SummaryItems in this Summary are not functioning as intended and/or need repair. This summary is not the entire report. The complete

report may include additional information of concern to the client. It is recommended that the client read the complete report.

Exterior

1. Front Exterior Surface Type: Wood siding - Siding had wood decay, which should be repaired or replaced to

reduce chances of further decay or water intrusion.

Lots and Grounds

2. Patio: Concrete - Patio was cracked throughout. Recommend resurfacing or replacement to help prevent further

deterioration and tripping hazards.

3. Fence: Wood - Wooden fence was in contact with the dirt below, which can lead to decay and pest infestation.

Only treated wood should be in contact with the dirt. Dirt should be removed from the bottom of the fence.

Roof

4. Gutters: Partial, Plastic - Some gutters were present. The addition of gutters would help ensure that rainwater

gets transported away from the building structure and foundation, improving the life of both.

5. Downspouts: None present - Downspouts were not installed. Recommend adding downspouts to guide water

down from the roof, toward extended leaders and/or a drainage system that can move water away from any

structures.

Kitchen

6. Main Kitchen Air Gap Present? No Dishwasher did not have an Air Gap installed. A physical air gap helps protect

the public water supply in case of a loss of pressure. Although required by the local building code, many people

opt to go without. If this is the case, a high-loop of the dishwasher drain line under the counter is highly

recommended (or some other means of backflow prevention).

7. Main Kitchen Counter Tops: Tile - Grout was damaged or missing and should be repaired. Damaged grout could

allow tiles to move or water to move off the counter into the cabinets below.

8. Main Kitchen Door: Vinyl sliding, Dual paned - Door lock was not functional and should be repaired.

Bathrooms

9. Master Bathroom Floor: Tile - Grout between tile is damaged or missing. Grout holds tile in place and helps seal

against moisture intrusion and should be replaced or repaired as necessary. This is a part of ongoing

maintenance.

10. Master Bathroom Toilet: American Standard - The toilet was loose at the floor, which can lead to a leak or

seepage. Recommend a new wax ring be installed when repaired.

11. Master Bathroom Ventilation: Window only - Recommend installation of ventilation fan to help prevent

excessive moisture.

12. Hallway Bathroom Tub/Surround: Porcelain tub, Stone surround

13. Hallway Bathroom Toilet: Kohler - The toilet was loose at the floor, which can lead to a leak or seepage.

Recommend a new wax ring be installed when repaired.

Steadfast Home Inspection, LLC 30 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 32: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Defective Summary (Continued)Defective Summary (Continued)

Parking

14. Main Garage Garage Doors: Metal - Garage door weather-stripping did not make solid contact with the ground,

which could create an entry point for water or pests. Recommend correction.

Attic

15. Main Attic Signs of Pests: Wood destroying organisms - Recommend further evaluation by a qualified pest

inspector.

Heating System

16. Closet Heating System Blower Fan/Filter: Direct drive with disposable filter - Filter is dirty and should be

replaced. Recommend following manufacturer's recommendations for changing the HVAC system filter(s).

Steadfast Home Inspection, LLC 31 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 33: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Marginal SummaryItems in this Summary are either in a state of reduced functionality or near the end of their intended life. This summary is not the

entire report. The complete report may include additional information of concern to the client. It is recommended that the client read

the complete report.

Lots and Grounds

1. Driveway: Concrete - Driveway had cracking that appeared typical and should be monitored. If condition

worsens, correction may be necessary in order to ensure stability of driveway.

2. Walks: Concrete - Sidewalk had cracking that appeared typical and should be monitored. If condition worsens,

correction may be necessary in order to ensure stability of walkway.

3. Vegetation: Trees - Trees planted within 10 feet of the foundation could cause damage. Recommend removal of

any trees within this distance.

Roof

4. Main Roof Surface Material: Asphalt shingle - Shingles throughout the roof had missing granules. There were

torn and cracked shingles in various places. While no evidence of current leakage was observed, leaks may

develop without warning.

Roof had exposed fasteners that could be an entry point for water. An appropriate sealant should be applied over

the fasteners. This is a regular maintenance issue that should be performed as needed.

5. Gutters: Partial, Plastic - Gutters had debris in them and should be cleaned in order to function properly.

Kitchen

6. Main Kitchen Door: Vinyl sliding, Dual paned - Screen was torn or damaged.

Living Space

7. Sun Room Living Space Door: Vinyl sliding, Dual paned - Screen was torn or damaged.

Bedrooms

8. Master Bedroom Closet: Single - Closet doors were missing or not installed.

9. Master Bedroom HVAC Source: Heating system register - Little or no air flow was felt from the vent while the

HVAC system was in operation. Recommend further evaluation by a qualified HVAC contractor.

10. Second Bedroom Windows: Aluminum sliding, Single paned - Window screen was loose and should be

re-secured.

11. Second Bedroom Closet: Single - Closet doors were missing or not installed.

12. Second Bedroom HVAC Source: Heating system register - Little or no air flow was felt from the vent while the

HVAC system was in operation. Recommend further evaluation by a qualified HVAC contractor.

13. Third Bedroom Closet: Single - Closet doors were missing or not installed.

14. Fourth Bedroom Windows: Aluminum sliding, Single paned - Window screen was torn or damaged.

15. Fourth Bedroom Closet: Single - Closet doors were missing or not installed.

Bathrooms

16. Master Bathroom Sink/Basin: Porcelain coated - Sink stopper did not function fully; water slowly drained when

closed.

Steadfast Home Inspection, LLC 32 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 34: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Marginal Summary (Continued)

Parking

17. Main Garage Garage Doors: Metal - Door panels have small to medium dents that do not affect the operation

of the door.

Steadfast Home Inspection, LLC 33 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 35: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Health/Safety SummaryItems in this Summary represent a possible health or safety concern. This summary is not the entire report. The complete report may

include additional information of concern to the client. It is recommended that the client read the complete report.

General Information

1. Asbestos: Asbestos material observed - Homes built prior to 1978 may be built with materials known to contain

asbestos. Products like acoustic ceiling spray texture ("popcorn" or "cottage cheese" ceilings), tiles, vent flues, and

linoleum are some examples of materials that may contain asbestos. In many cases it is safe to leave these

materials in the home, if they are in places where they will not be disturbed. If the material must be removed (as

in the case of renovation or remodel), it should be handled and disposed of in accordance with EPA guidelines.

2. Lead Paint: Lead paint suspected based on age - Homes built prior to 1978 may contain lead paint. Lead paint

can deteriorate into lead dust that can be harmful when inhaled, especially by the elderly or young children. While

lead paint can be "encapsulated" by painting over it with non-lead paint, chips of paint may still be dangerous.

Painted wooden windows are also sources of lead dust in a home as the abrasive action of opening & closing

makes dust more likely. An environmental services company can determine if lead paint is present.

Roof

3. Electrical Mast: Mast with tie back at roof - Drip loops were not of adequate length to keep water from running

down the mast to the electrical service. Drip loops should be repaired for occupants' safety to help prevent a

possible service outage.

Kitchen

4. Main Kitchen Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be treated as if it

contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to occupants and

should be avoided. Disposal should be done in accordance with EPA recommendations.

Living Space

5. Living Room Living Space Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos,

identification of which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to

occupants and should be avoided. Disposal should be done in accordance with EPA recommendations.

6. Hallway Living Space Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos,

identification of which is beyond the scope of this inspection. For safety of occupants, the material should be

treated as if it contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to

occupants and should be avoided. Disposal should be done in accordance with EPA recommendations.

Bedrooms

7. Master Bedroom Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be treated as if it

contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to occupants and

should be avoided. Disposal should be done in accordance with EPA recommendations.

Steadfast Home Inspection, LLC 34 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 36: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Health/Safety Summary (Continued)8. Second Bedroom Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be treated as if it

contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to occupants and

should be avoided. Disposal should be done in accordance with EPA recommendations.

9. Third Bedroom Ceiling: Popcorn / Acoustic ceiling - "Popcorn" ceilings may contain asbestos, identification of

which is beyond the scope of this inspection. For safety of occupants, the material should be treated as if it

contains asbestos until tested. Scraping, or disturbing in any way that creates dust is a hazard to occupants and

should be avoided. Disposal should be done in accordance with EPA recommendations.

Bathrooms

10. Master Bathroom Electrical: 120VAC - Current practice calls for GFCI outlets in any areas that may get wet,

such as kitchens and baths, to reduce risk of shocks. Outlets in this room were not GFCI protected and protective

devices should be installed.

11. Hallway Bathroom Electrical: 120VAC - Current practice calls for GFCI outlets in any areas that may get wet,

such as kitchens and baths, to reduce risk of shocks. Outlets in this room were not GFCI protected and protective

devices should be installed.

Laundry

12. Garage Laundry Room/Area Washer Hose Bib: Rubber hoses - Washer hoses were rubber, which are more

prone to bursting that the recommended braided style. For safety, they should be replaced.

13. Garage Laundry Room/Area Washer and Dryer Electrical: 120 VAC - Outlet or switch was missing its cover.

Cover should be installed to help reduce risk of electrocution.

14. Garage Laundry Room/Area Electrical: 120VAC - Electrical outlets in Laundry areas should be GFCI-protected

for safety. Recommend installation of GFCI-protection devices, whether receptacles or breakers to protect all

Laundry outlets.

Attic

15. Main Attic Wiring/Lighting: 120 VAC - Junction box missing cover. Recommend covering to help protect from

risk of shock.

Electrical conductors had insulation worn through, exposing the copper conductors. Recommend replacement or

repair.

16. Main Attic Signs of Pests: Signs of rodents - Recommend further evaluation by a qualified pest inspector.

Electrical

17. Exterior Wall Electric Panel Manufacturer: Unknown - The service panel had no dead front cover (inner cover),

leaving wiring exposed. Recommend installation for occupants' safety.

Distribution panel was lacking a legend describing each circuit in a way that is clear and unambiguous.

Recommend labeling each circuit.

18. Exterior Wall Electric Panel AFCI: None observed - No Arc-Fault Circuit Interrupter (AFCI) devices were

installed in the panel. Though not required when this home was built, AFCIs are now commonly called for at all

circuits feeding lights or receptacles in bedrooms, living rooms and hallways. They help protect against electrical

fires caused by electrical arcing both at the installed wiring in the walls and anything plugged into the protected

outlets. Recommend installation of AFCI devices.

Steadfast Home Inspection, LLC 35 of 36 6892 Trigo Rd

Palm-Tech Inspector, Copyright © 1998-2019, PDmB, Inc.

Steadfast Home Inspection, LLC

Page 37: Steadfast Home Inspection, LLC...Steadfast Home Inspection 805-295-8009 HOME INSPECTION REPORT 6892 Trigo Rd Goleta, CA 93117 Prepared for: Ann Marie & Hal KopeikinExterior Visual

Health/Safety Summary (Continued)

Heating System

19. Suspected Asbestos: Yes - The material insulating the duct transition boots is likely to contain asbestos.

Recommend care be taken when handling. Removal should be done in accordance with EPA guidelines.