University of Michigan, TCAUP Structures II Slide 1 of 22
Architecture 324Structures II
Steel Column Analysis and Design
ā¢ Failure Modesā¢ Effects of Slendernessā¢ Stress Analysis of Steel Columnsā¢ Capacity Analysis of Steel Columnsā¢ Design of Steel Columns
University of Michigan, TCAUP Structures II Slide 2 of 22
Leonhard Euler (1707 ā 1783)
Euler Buckling (elastic buckling)
ā A = Cross sectional area (in2)ā E = Modulus of elasticity of the material (lb/in2)ā K = Stiffness (curvature mode) factorā L = Column length between pinned ends (in.)ā r = radius of gyration (in.)
portrait by Emanuel Handmann,1753
University of Michigan, TCAUP Structures II Slide 3 of 22
Analysis of Steel Columns
Conditions of an Ideal Column
ā¢ initially straightā¢ axially loadedā¢ uniform stress (no residual stress)ā¢ uniform material (no holes)ā¢ no transverse loadā¢ pinned (or defined) end conditions
University of Michigan, TCAUP Structures II Slide 4 of 22
Analysis of Steel Columns
Short columnsFail by material crushingPlastic behavior
Intermediate columnsCrush partially and then buckleInelastic behaviorLocal buckling ā flange or webFlexural torsional buckling - twisting
Long columnsFail in Euler bucklingElastic behavior
short intermediate long
University of Michigan, TCAUP Structures II Slide 5 of 22
Analysis of Steel Columns
Estimate ofeffective length factor, K
University of Michigan, TCAUP Structures II Slide 6 of 22
Analysis of Steel Columns
Estimate of K:
University of Michigan, TCAUP Structures II Slide 7 of 22
Determining K factorsby Alignment Charts
Sidesway Inhibited:Braced frame1.0 > K > 0.5
Sidesway Uninhibited:Un-braced frameunstable > K > 1.0
More Pinned:If Ic/Lc is largeand Ig/Lg is smallThe connection is more pinned
More Fixed:If Ic/Lc is smalland Ig/Lg is largeThe connection is more fixed
G = ā
ā
Sidesway inhibited
University of Michigan, TCAUP Structures II Slide 8 of 22
Determining K factorsby Alignment Charts
Sidesway Inhibited:Braced frame1.0 > K > 0.5
Sidesway Uninhibited:Un-braced frameunstable > K > 1.0
More Pinned:If Ic/Lc is largeand Ig/Lg is smallThe connection is more pinned
More Fixed:If Ic/Lc is smalland Ig/Lg is largeThe connection is more fixed
G = ā
ā
Sidesway uninhibited
University of Michigan, TCAUP Structures II Slide 9 of 22
Analysis of Steel Columns - LRFD
Euler equation:
Short & Intermediate Columns:
Long Columns:
Transition Slenderness
short long
University of Michigan, TCAUP Structures II Slide 10 of 22
Analysis of Steel Columnspass / fail by LRFD
Data:ā¢ Column ā size, lengthā¢ Support conditionsā¢ Material properties ā Fyā¢ Factored load ā Pu
Required:ā¢ Pu Ćø Pn (pass)
1. Calculate slenderness ratios. Lc/r , Lc=KLThe largest ratio governs.
2. Check slenderness ratio against upper limit of 200 (recommended)
3. Calculate transition slenderness 4.71 šø/š¹š¦and determine column type (short or long)
4. Calculate Fcr based on slenderness
5. Determine ĆøPn and compare to PuPn = Fcr Ag Ćø = 0.9
6. If Pu Ćø Pn , then OK
Short
Long
University of Michigan, TCAUP Structures II Slide 11 of 22
Analysis of Steel Columnspass / fail by ASD
Data:ā¢ Column ā size, lengthā¢ Support conditionsā¢ Material properties ā Fyā¢ Factored Load ā Pu
Required:ā¢ Pu Ćø Pn (pass)
1. Calculate slenderness ratios.The largest ratio governs.
2. Check slenderness ratio against upper limit of 200 (recommended)
University of Michigan, TCAUP Structures II Slide 12 of 22
3. Calculate transition slenderness 4.71 šø/š¹š¦ and determine column type (short or long)
4. Calculate Fcr based on slenderness
5. Determine ĆøPn and compare to Pu
6. If Pu Ćø Pn , then OK
Analysis of Steel Columnspass / fail by ASD
W8x35
University of Michigan, TCAUP Structures II Slide 13 of 22
Analysis of Steel Columnscapacity by LRFD
Data:ā¢ Column ā size, lengthā¢ Support conditionsā¢ Material properties ā Fy
Required:ā¢ Max load capacity
1. Calculate slenderness ratios.The largest ratio governs.
2. Check slenderness ratio against upper limit of 200 (recommended)
3. Calculate transition slenderness 4.71 šø/š¹š¦ and determine column type (short or long)
4. Calculate Fcr based on slenderness
5. Determine ĆøPn and Compute allowable capacity: Pn = Fcr Ag Pu = ĆøPn
Short
Long
University of Michigan, TCAUP Structures II Slide 14 of 22
Capacity Example 1
Free standing columnThird floor studio spaceSupports roof load = 20 psf DL + SL
snow 15lbs / FT depth
University of Michigan, TCAUP Structures II Slide 15 of 22
Capacity Example 1
1. Calculate slenderness ratios.The largest ratio governs.
2. Check slenderness ratio against upper limit of 200 (recommended)
3. Calculate transition slenderness 4.71 šø/š¹š¦ and determine column type (short or long)
4. Calculate Fcr based on slenderness
University of Michigan, TCAUP Structures II Slide 16 of 22
Capacity Example 1
5. Determine ĆøPn and Compute allowable capacity: Pu = ĆøPn
DL = 20 psf
20 psf (1600 sf) = 32k on column
University of Michigan, TCAUP Structures II Slide 17 of 22
Capacity Example 2long column ā using equations
rx = 3.51 in.ry = 2.03 in.
University of Michigan, TCAUP Structures II Slide 18 of 22
Capacity Example 2 long column ā using table
University of Michigan, TCAUP Structures II Slide 19 of 22
Design of Steel Columnswith AISC Strength Tables
Data:ā¢ Column ā lengthā¢ Support conditionsā¢ Material properties ā Fy
ā¢ Applied load - Pactual
Required:ā¢ Column Size
1. Enter table with height, KL = Lc2. Read allowable load for each section to
find the smallest adequate size.3. Tables assume weak axis buckling. If
the strong axis controls the length must be divided by the ratio rx/ry
4. Values stop in table (black line) at slenderness limit, KL/r = 200
University of Michigan, TCAUP Structures II Slide 20 of 29
University of Michigan, TCAUP Structures II Slide 21 of 22
AISC Critical Stress Table for previous example Kl/ry = 118.2
University of Michigan, TCAUP Structures II Slide 22 of 22
AISC Critical Stress Table
for previous example Kl/ry = 118.2
University of Michigan, TCAUP Structures II Slide 23 of 22
Steel Frame Construction
University of Michigan ā North Quad
University of Michigan, TCAUP Structures II Slide 24 of 29
Steel Frame ConstructionMesse Leipzig ā 1996
Congress Centre ā Gerkan, Marg und PartnerGlass Hall ā Ian Ritchie ArchitectsTower - Schlaich, Bergermann und Partner
Messe Leipzig - Glass Hall - Ian Ritchie Architects Messe Leipzig ā Cable braced tower. Jƶrg Schlaich
University of Michigan, TCAUP Structures II Slide 25 of 29
Steel Frame Construction
Messe Leipzig Glass Hall - Ian Ritchie Architects
University of Michigan, TCAUP Structures II Slide 26 of 29
Steel Frame Construction
Messe Leipzig Glass Hall - Ian Ritchie Architects
University of Michigan, TCAUP Structures II Slide 27 of 29
Steel Frame Construction
Messe Leipzig Glass Hall - Ian Ritchie Architects
University of Michigan, TCAUP Structures II Slide 28 of 29
Branching Columns (tree columns)
bridge in Pragsattel, Stuttgart, 1992Schlaich, Bergermann und Partner
University of Michigan, TCAUP Structures II Slide 29 of 29
Branching Columns (tree columns)
Stuttgart Airport Terminal,Gerkan, Marg und PartnerSchlaich, Bergermann und Partner