    Stelth

    Reference Electrodes

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    2/114

    PVC plastic tube

    Wooden Plug

    Saturated CuSO4Solution or gelatin

    Pure Copper Rod

    Copper Lead Wire

    Epoxy seal

    Old Technology

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    3/114

    Problem...

    Making Contactwith the Soil

    Solution

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    4/114

    Add

    18-24 lbs. of

    Plaster

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    5/114

    plaster

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    6/114

    New PROBLEM . . . . .

    Plaster is

    Dehydration of CuSO4Solution

    Hygroscopic!!!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    7/114

    plaster

    CuSO4 Solutiongoes into

    plaster

    Dehydration ofCuSO4 Solution

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    8/114

    plaster

    More CuSO4Solution goes

    into plaster

    ReferenceElectrode is

    dying

    More Dehydration

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    9/114

    plaster

    Opened circuitfrom shrinking Hardened plaster

    ReferenceElectrode is dying

    More DehydrationMore Problems

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    10/114

    Another Problem . . . . . .

    Cannot TEST

    TheREFERENCE ELECTRODE in Plaster

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    11/114

    Another Problem . . . . . .

    Plaster is Hygroscopic therefore

    NO SHELF LIFE

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    12/114

    plaster

    Hard plaster

    Dead Cell !

    Old Technology

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    13/114

    Installation Costs!

    Still Another PROBLEM

    ACTIVATION TIME

    ACTIVATION takes 2 to 6 hours.

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    14/114

    No shelf life, generally one month!

    No protection against chloride attack!

    No protection against H2S attack!

    Casting Plaster is Hygroscopic!

    High Installation Costs!

    Cannot be frozen! No winter installations! Copper Sulfate Chemistry in liquid or gelatin

    form leaches into the environment - Always!!

    Design Flaws of Old Technology

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    15/114

    Solves these Problems

    New Stelth Technology . . . . .

    and Adds NEWFeatures . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    16/114

    New Stelth Technology, Specification . . .

    Indefinite Shelf Life!

    Chloride & Chlorine Ion Trappers!

    Hydrogen Sulfide (H2S) Ion Trappers!

    Moisture Retention Membranes!

    Expanded Sensing Area!

    Weight Reduction (miniaturization)

    30 year guaranteed life!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    17/114

    New StelthTechnology . . . . .

    Uses Medical Grade Ceramicfor Sensing Area

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    18/114

    New StelthTechnology . . . . .

    Reduces IR Drop from cell to structure!

    Reduces IR Drop by lowering internal resistance of electrode!

    Greater sensitivity in High-Resistance and Dry Soils

    Highest Quality - Used in hospitals & space craft to filter water!

    Same material used to grind steel tools! Very Tough!

    Ceramic Sensing Area 36 Times Larger

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    19/114

    Impregnated with Ion Trappers

    Traps Chloride & Chlorine Ions

    New StelthTechnology . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    20/114

    Military Grade Epoxy for Sealing

    Used in sea water installations by the US Navy! Will not degrade in seawater or fresh water!

    New StelthTechnology . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    21/114

    Military Grade Epoxy for Sealing

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    22/114

    Highest Purity Chemistry

    Highest quality CuSO4 (laboratory grade)

    Completely Solid State chemistry

    Highly Conductive

    Blended with an H2S Ion Trapping carrier

    New Stelth Technology . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    23/114

    Solid State chemistry

    New Stelth Technology

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    24/114

    ChoicesA 30 year reservoirof Copper Sulfate

    OR

    A 2 year reservoirof Copper Sulfate

    Water

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    25/114

    99.99% Pure Copper Sensing Element

    Highest quality Copper, non-oxygenated!

    Treated to expand the surface area by a factor of 8!

    Vapor-phased decontaminated!

    Clean room bathed, de-tarnished & assembled!

    New Stelth Technology . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    26/114

    99.99% Pure Copper Sensing Element

    New Stelth Technology . . . . .

    Treated to expand to 8 timesnormal surface area

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    27/114

    Water & Chemical Proof Connection

    Triple Lead Wire Seal!

    Wire is RHH-RHW and is UL approved!

    Wire is flame proof!

    Wire is a low-density & cross-linked polymer!

    Which allows cuts to be repaired in the field!

    Wire is flexible in sub-zero weather!

    New Stelth Technology . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    28/114

    The Finished Concept!

    Hydrogen Sulfide (H2S) Indicators

    New Stelth Technology . . . . .

    Stelth

    Stelth

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    29/114

    Stelth

    Reference Electrode

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    30/114

    Choices33 square inchesof Sensing Area

    OR

    1 to 2 square inchesof sensing area

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    31/114

    This ChoiceIs Why

    This technologyGives

    UnparallelPerformance in

    Desert Dry Soilsand

    Flood Zones

    Over this choice

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    32/114

    Using Todays Technology

    We can produce a reference

    electrode that has absorbedand applied all availabletechnologies discovered

    since 1922 ..

    Stelth

    Stelth

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    33/114

    New Stelth Technology . . . . .

    StelthReference Electrodes

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    34/114

    All Stelth Reference ElectrodesareTested to the Highest Standards in an

    ISO-9000 Certified Facility

    Continuity of wire!

    Continuity of wire insulation!

    Resistance of lead wire and sensing elementconnection (has to be a dead short)!

    Internal resistance of reference electrode!

    Calibration of Reference Electrodes are done at the

    final state of assembly at 25Celsius!

    Final test is for response time from activation to

    stable reading without Hysteresis!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    35/114

    New StelthTechnology . . . . .

    Each unit has a Serial Number and

    Comes with Certified Test Certificate

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    36/114

    New StelthTechnology . . . . .

    Tested and Serial Number applied

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    37/114

    And Remember! Installation Time.

    Lets Compare...

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    38/114

    Old TechnologyInstallation Procedure

    Pipe

    1 2 3 4 5

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    39/114

    Old TechnologyInstallation Procedure

    Pipe

    1 2 3 4 5 6 hours

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    40/114

    Pipe

    1 hour

    Installation Procedure for theStelth Reference Electrode

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    41/114

    What is the latest Technology in the world ofCorrosion Today?

    Stelth 7 IR Free Probes . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    42/114

    Stelth 7 IR Free Probes . . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    43/114

    1 cm2

    5+5 cm2

    10 cm2

    Stelth 7 IR Free Probes . . . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    44/114

    Stelth 7

    Rocket IR Free Probes . . . .

    10+10 cm2

    50+50 cm2

    100 cm2

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    45/114

    EC/DIN-50925 IR Free Probe

    Developed with the cooperation of

    European Governments by the largest

    Gas Distribution & Pipeline Company in Europe . . .

    and is now a DIN Standard

    Ruhr Gas

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    46/114

    EC/DIN-50925 IR Free Probe Reads Average potential of pipeline!

    Reads Current Required to protect Worst Holiday!

    Compatible Remote Monitoring & Control Systems!

    Reads the ON & OFFPotentials of the Worst Conditionon your pipeline!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    47/114

    EC/DIN-50925 IR Free Probe Eliminates expensive interrupters & the difficult

    task of synchronizing them.

    Allows you to take IR Free Off Potential readings

    on High Amperage Rectifiers without interruptingor turning rectifier off.

    IR FreeOn & Off Potential readings can takenwith total disregard for outside influences such as:

    Other Pipelines, Your Own Rectifier,Subways,Electrical Trains, Electrical TransmissionLines, Anode Beds, et cetera.

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    48/114

    This is the . . . .

    PROBLEM . .

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    49/114

    -.85

    -.85-.85

    -.85

    -.85

    Gas Water

    Electric

    TelecomTrains

    BAD READING

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    50/114

    -.61

    -.48-.81

    -.71

    -.43

    Gas Water

    Electric

    TelecomTrainsBAD READING

    BAD READING

    BAD READING

    BAD READINGBAD READING

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    51/114

    The Solution

    TheStelth 7 IR Free Probe

    85

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    52/114

    -.85

    -.85

    -.85

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    -.85

    -.85

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    53/114

    TheStelth 7 IR Free Probe

    Ignores all other systems,

    Electric,Water,Cable,

    Trains,

    Oil Lines,et cetera.

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    54/114

    This is the way..

    Consolidated Edison in New York City

    &

    City of San Diego in California

    Now see their systems.

    85

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    55/114

    -.85

    -.85-.85

    -.85

    -.85

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    Stelth 7 IR Free Probe

    C

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    56/114

    EC/DIN-50925 IR Free Probe

    164 (50m)

    Specification for development of the Stelth 7 IR Free Probe

    Read the WORST potential in a 50 meter pipe section!

    Read the average potential!

    Read current density!

    Read IR Free On & Off potentials!

    Be able to SEE the 100 mV shift!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    57/114

    10 ohms

    30 ohms

    100 ohms

    164 (50m)

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    58/114

    10 ohms

    30 ohms

    100 ohms

    164 (50m)

    10

    5

    0

    IR FreeON Potential

    Reading

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    59/114

    10 ohms

    30 ohms

    100 ohms

    164 (50m)

    10

    5

    0

    IR FreeOFF Potential

    Reading

    while viewing the

    100 mVshift

    100 V C it i

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    60/114

    0 1 3 4 5

    -.85

    -.80

    -.75

    -.70

    -.65-.60

    -.55

    -.50-.45

    Shift is 125 mV

    Seconds

    mV

    100 mV Criterion

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    61/114

    Stelth

    IntermissionReference Electrodes

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    62/114

    TheStelth 7 IR Free Probe

    Installation . . . .

    is Simple . . . .

    Stelth 7 Rocket IR Free Probe

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    63/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    64/114

    GovernmentAuthorization

    to dig

    Installation Site

    Installation Site

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    65/114

    Installation Site

    Old Test PointTo be removed

    36 Pipelineburied

    1.75m deep

    PipelineMarker

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    66/114

    6 hole drilled to 2.5 meters

    Stelth 7 Rocket Hole Placement

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    67/114

    36 Pipe

    1.75 meters

    .37 meters

    2.25 meters

    Spring Line(Horizontal Centerline)

    Stelth 7 Rocket Hole Placement

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    68/114

    Presoaking Stelth 7Rocket for 20 seconds

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    69/114

    Presoaking Stelth 7Rocket for 20 seconds

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    70/114

    Insertion of Stelth 7Rocket

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    71/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    72/114

    pipeline wire

    Stelth 7wire

    pipeline wire

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    73/114

    splice box

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    74/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    75/114

    pipeline wire

    Stelth 7wire

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    76/114

    pipelinewire

    Stelth 7wire

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    77/114

    Stelth 7

    wire

    pipeline wire

    splice wire

    pipeline wire

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    78/114

    splice wire

    p pe e e

    splice

    Test pointconduit

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    79/114

    conduit

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    80/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    81/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    82/114

    Installing

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    83/114

    Old test point

    Installing

    Bullet BoxInterrupter &

    Test Station

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    84/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    85/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    86/114

    Coupons IR Drop(connected to pipeline)

    Reference Cell

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    87/114

    (connected to pipeline)

    Coupons IR Free(dead lead)

    Pipeline

    Future connection for

    ComancheDart

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    88/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    89/114

    Testing that Stelth 7is activated

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    90/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    91/114

    Disconnect pipelineConnection for 60 days

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    92/114

    Recording Date ofInstallation

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    93/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    94/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    95/114

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    96/114

    Sending 12 months of data to theDART

    Interrogator350 meters down the mountain!

    All

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    97/114

    Reference Electrode Designs

    manufactured...

    are affected by conditions that will alterthe performance or destroy your

    reference electrode

    Here are a several

    Causes of Malfunction and Failure!!!

    Take the Plastic Bag OFF before installation!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    98/114

    Take the Plastic Bag OFFbefore installation!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    99/114

    pH..

    Can KILL reference electrodes

    Acidity 9

    The Reference Electrodei A d !

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    100/114

    is not an Anode!

    Dont Connect it like an Anode!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    101/114

    Don t Connect it like an Anode!

    A V

    S

    hunt

    Temperature

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    102/114

    Temperature..

    Can alter the accuracy & completelyshut down a reference electrodes

    Upper Limit = 176 F (80 C)

    Lower limit = -10 F (-23 C)

    Environment

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    103/114

    Environment..Can determine the accuracy of any reference

    electrodes

    Zinc-Zinc Sulfate Zn-ZnSO4

    MUST be in a non-chloride environment

    Either inSoil or Water

    Copper-Copper Sulfate Cu-CuSO4or

    WHY

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    104/114

    WHY..

    Because the chlorides alter

    the chemistry of the copper sulfate

    and prevent the necessary

    ion exchangebetween the

    coppersensing elementand the environment

    Chl id

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    105/114

    Chlorides..Kill more reference electrodes than any

    other single influence

    1000 PPM(parts per million)

    will KILL any reference electrode

    NOW

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    106/114

    NOW..

    Silver-Silver Chloride Ag-AgCIis a different story.

    To achieve a proper ion exchange

    You need between

    10,000 and 27,000 ppmof chlorides with 19,000 ppm

    being ideal, which is seawater

    Reference Electrode Wire must have itsOwn Conduit Return!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    107/114

    Own Conduit Return!

    Induced AC Current

    A V

    S

    hunt

    Do not run Anode wires & Reference Electrodei t th i th d it!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    108/114

    wires together in the same conduit!

    A V

    S

    hunt

    H drogen S lfide

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    109/114

    Hydrogen Sulfide

    H2S will kill any reference electrodes!

    100 PPM(parts per million)

    is the maximum level that areference electrode can tolerate!

    Do Not Locate Reference Electrodes Near AnyAnodes Impressed Current or Sacrificial!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    110/114

    Anodes, Impressed Current or Sacrificial!

    A V

    S

    hunt

    Do Not use the Negative Return from the Pipeline to theRectifier for the Reference Electrode Return Wire!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    111/114

    Rectifier for the Reference Electrode Return Wire!

    To Anodes

    A V

    S

    hunt

    From Structure

    Negative Return

    Do not locate under Electrical Transmission Lines!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    112/114

    A V

    Shunt

    Induced AC Current

    Hydrocarbons

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    113/114

    Hydrocarbons.

    any amount will destroy areference electrode!

    Zero PPM(parts per million)

    is the maximum level that areference electrode can tolerate!

  • 8/2/2019 Stelth Reference Electrodes Presentation for Wikon 03-21-2010

    114/114

    StelthThe End