51
STEP 7 V14 New functions Programming; editors and usability; system functions Unrestricted © Siemens AG 2016

STEP 7 V14 New functions - ad.siemens.com.cn...SIMATIC STEP 7 in the TIA Portal Highlights of STEP 7 V14 Page 2 6. System functions 5. Online functions 4. Alarming 3. Language innovations

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

  • STEP 7 V14

    New functions

    Programming; editors and usability; system functions Unrestricted © Siemens AG 2016

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 2

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Support of new CPU‘s

    Functions

    • S7-1500 T-CPU family with integrated motion control

    functionality like “Synchronous axis” and “Output cam”

    • CPU 1518(F)-4 PN/DP ODK (Open Development Kit):

    • Integration of C/C++ functions using ODK 1500S

    • Integration of Simulink® models using Target 1500S

    • CPU 1516pro (F)-2 PN

    • Failsafe S7-1500 Software Controller

    • CPU 1212FC

    S7-1500T-CPU CPU 1518(F)-4 PN/DP ODK

    CPU 1516pro(F)-2 PN

    Seite 3

    CPU 1507SF & CPU 1515SP PC F

    New New

    New

    New

    CPU 1212FC New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Grouping of devices in the project navigation

    Functions

    • Grouping of I/O devices/slaves

    in the project navigation

    Benefits

    • Technological merging

    of devices

    • Devices as part of large applications

    can be located more quickly

    Page4

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Horizontal or vertical division of the network/device view

    Functions

    • The arrangement of the network/device view

    can be chosen freely.

    Benefits

    • The vertical division of the device view provides

    its user with a structured overview of all devices

    and can be used for editing the most important

    device properties.

    • The horizontal division of the network view is

    most helpful for editing all of the parameters of

    the configured connections.

    Page5

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Synchronization of the network and topology view

    Network view Topology view

    Topology view after synchronization

    Functions

    • The arrangement of the devices in the

    topology view can be synchronized with

    the network view.

    Benefits

    • Standardized user interface for both the

    device and topology view

    • Fast adjustment of the topology view

    Page6

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Firmware update under online accesses (also called LifeList)

    Functions

    • In addition to the CPU/IM, the

    online & diagnostics editor under

    online accesses displays all

    plugged-in modules.

    • Modules can be updated

    individually.

    Benefits

    • The user can perform a device

    update regardless of whether all

    modules have been configured in

    advance.

    Page7

    New

  • Unrestricted © Siemens AG 2016

    Profile definition in the hardware catalog

    • The user-defined hardware catalog allows

    quick and easy access to frequently used

    modules.

    • Article number-specific

    • Defined profiles can be exported via

    Tools/Settings/General.

    Mass operations for assigning a new

    controller to I/O devices

    • New context menu entries for individual

    stations guarantee a quick assignment to I/O

    controllers.

    • Multiple selection possible

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Collection of useful functional extensions

    Page8

    New

    New

  • Unrestricted © Siemens AG 2016

    Changing device properties "in-place"

    • Important properties such as IP addresses

    and device names can be changed directly

    in the network view.

    Detailed information in the address

    overview

    • The device name and the I/O system help

    to clearly identify modules.

    • The user can view the size of the address

    area at a glance.

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Collection of useful functional extensions

    New

    Page9

    New

    New New New

  • Unrestricted © Siemens AG 2016

    Assigning a PN device name as a mass

    operation

    • The PROFINET device name can be

    assigned as a mass operation in the network

    view/IO-communication.

    Topology comparison in table view

    • The table view allows a compact overview of

    both the online and offline configuration.

    • They can easily be synchronized.

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Collection of useful functional extensions

    Page10

    New

    New

  • Unrestricted © Siemens AG 2016

    Structured IO tags

    • Graphic display of structured IO tags in the

    table

    • Display of overlapping variables

    SIMATIC STEP 7 in the TIA Portal – Hardware and network editor

    Collection of useful functional extensions

    Page11

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 12

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    SCL networks in LAD/FBD

    Functions

    • SCL networks can be inserted in an LAD (FBD) block.

    Benefits

    • Depending on the use case, the ideal programming

    language can be selected freely within a block, e.g. LAD

    for links and SCL for subsequent mathematical

    calculations, so that programming becomes considerably

    more efficient.

    • An SCL network, for example, can now be inserted

    instead of the Calculate Box.

    Page 13

    S7-1200 S7-300/400/WinAC

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    SCL regions – "networks" for SCL

    Functions

    • New keyword REGION (cf. C#)

    • Any name including spaces and special characters

    • Nested regions

    • Open/closed status is saved

    • Synchronized navigation column including the display of

    syntax errors

    Benefits

    • Code structuring

    • Enhanced overview and readability

    • Simple navigation even in large blocks

    Page 14

    S7-1500 S7-1200 S7-300/400/WinAC

    New

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Hiding block parameters (LAD/FBD)

    Functions

    • Useable for:

    • FBs and FCs

    • All parameter types (In, Out and InOut)

    • All data types

    • Can be found in the properties of the parameter

    • Adjustable options:

    • Show

    • Hide for assigned and unassigned parameters

    • Hide if no parameter is assigned

    Benefits

    • Improved overview of blocks with many optional

    parameters

    Page 15

    S7-1200 S7-300/400/WinAC

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Automatic numbering of blocks

    Function

    • Block numbers required for internal

    processing are assigned automatically by the system

    (setting in the block properties)

    • The system resolves conflicts in the block numbers

    automatically, e.g. due to copying processes.

    • Conflicts can be resolved automatically by the system -

    even for know-how-protected blocks. A password is not

    required (prerequisite: Encryption was implemented using

    >= V13 SP1)

    Benefits:

    • User programs can be programmed symbolically

    • The user does not have to concern himself with numbers

    and number conflicts

    Copy and paste

    The system renumbers the

    blocks and resolves the

    conflict during the

    translation.

    S7-1500 S7-1200 S7-300/400/WinAC

    Page 16

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Comparing blocks using checksums

    Functions

    • Source codes can be compared using many filter options.

    • Evaluation of checksums in the user program

    Benefits

    • Differences in blocks are recognized more quickly.

    • The reasons for differences can be identified more quickly

    (e.g. the data type used has changed)

    • Filters enable a user-defined comparison

    • Program changes can be detected during runtime and be

    processed accordingly – for V14 the following evaluation

    options are possible:

    • Checksum for the complete standard program

    • F signature for the safety program and safety hardware

    Page 17

    Old_Checksum = C153Q3

    Cur_Checksum = XZA135

    Program Compare:

    PLC Program

    changed

    S7-1500 S7-1200 S7-300/400/WinAC

    GetChecksum()

    New

    New

  • Unrestricted © Siemens AG 2016

    Absolute address for standard blocks, also

    for structures

    • Structured tabs in standard blocks now show

    the absolute address instead of the relative

    offset

    Go to definition within the

    • UDT editor with tags of the type UDT

    • DB editor with tags of the type UDT

    • Interface editors with tags of the type

    FB, DB, and UDT

    Predefined block parameters

    • The predefined block parameter is entered

    automatically when the block is called

    • With FCs/FBs for IN, OUT and INOUT

    • With Intelli-Sense

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Collection of useful functional extensions

    Page 18

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    Declaring new tags as Temp

    • New tags are declared as Temp by default

    and not as bit memories

    Network status on opening/closing a block

    • Networks are displayed the same way they

    were displayed the last time the block was

    closed.

    Block information with up to 125 characters

    • For S7-1200/1500

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Collection of useful functional extensions

    Page 19

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    Hierarchical representation of the compile

    results

    • Display of the block subfolders

    • Enhanced overview

    SCL: Display all monitored values

    • Context menu for showing/hiding

    • All available tags are displayed

    SCL: CTRL + Click for Go to definition

    • Quick for defining a tag, FBs, ... jump via

    hyperlink

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Collection of useful functional extensions

    Page 20

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Collection of useful functional extensions

    Page 21

    “Undo” also available offline

    Global setting for Operand representation

    and Tag information

    New

    New

  • Unrestricted © Siemens AG 2016

    S7-Graph: Absolut_Info_Overlay

    • Optimized display of the absolute address

    (minimal column width)

    S7-Graph: Symbolic jump/jump target

    • Symbolic display of the jump and jump target

    in the DetailedSequenceView.

    S7-Graph: Hide Absolut_Info_Overlay

    • The Absolut_Info_Overlay can now be

    hidden using the context menu.

    SIMATIC STEP 7 in the TIA Portal – New editor functions

    Collection of useful functional extensions

    New

    New

    New

    New

    Page 22

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 23

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Array(*) for transferring arrays of variable length

    Functions

    • Array(*) as new parameter data type

    • LOWER_BOUND, UPPER_BOUND for determining the

    array boundaries

    • STL, SCL, LAD, FBD

    Benefits

    • Pointer programming for arrays of varying lengths no

    longer necessary

    • Better runtime performance than pointer (Any/Variant) and

    copying by MOVE_BLK

    • Fully symbolic and improved readability

    • Enables generic standard functions for arrays varying in

    length

    S7-1200 S7-300/400/WinAC

    Page 24

    New

    New

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Array of multi-instances

    Functions

    • Saving multi-instance data in an array

    (STL, SCL, LAD, FBD)

    • Multi-instances can be called in loops

    • Applies to PID-Tos* as well

    Benefits

    • Drastic reduction of code

    • Enhanced readability

    • Efficient programming of mass calls

    S7-1200 S7-300/400/WinAC

    Page 25

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Indexed access to technology objects

    Functions

    • List technology object (TO) instances in an array of

    DB_ANY

    • Hand over DB_ANY to a technology object

    • S7-1500: starting from FW V2.0

    • S7-1200: starting from FW V4.2

    Benefits

    • Indexed access to TOs in slopes instead of separate

    access requests

    • Reduction of code

    Page 35

    New

    S7-1500 S7-1200 S7-300/400/WinAC

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Transfer instance as parameter

    Functions

    • Transfer of an instance to an FC/FB

    • Call of the transferred instance in the FC/FB

    • STL, SCL, LAD, FBD

    Benefits

    • Standardized functions to which dynamic

    instances are transferred

    • The used instance has to be defined at the block

    call (not inside the block).

    S7-1200 S7-300/400/WinAC

    Page 27

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Constants

    Function:

    • Local and global constants can be used both in the code

    and as array boundaries.

    • For the declaration of a string, constants (local, global) can

    now be used for the length as well.

    Benefits:

    • Arrays and strings can be adapted centrally by changing

    the constant value.

    • Thus, for example, programs with a centralized adjustment

    to the availability of memory of CPUs can be adapted.

    S7-1500 S7-1200 S7-300/400/WinAC

    Page 28

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Serialize / Deserialize

    Serialize data

    • “Serialize” transforms structured

    data in a byte array.

    • “Deserialize” transforms a byte array

    in a structure.

    SERIALIZE

    Structure

    • Var1 : Byte

    DESERIALIZE

    2#0000_0001

    2#0000_0000

    S7-1500 S7-1200 S7-300/400/WinAC

    Structure

    • Var1 : Bool = true

    • Var2 : Bool = false

    • Var3 : Bool = false

    • Var4 : Bool = false

    • Var5 : Bool = false

    • Var6 : Bool = false

    • Var7 : Bool = false

    • Var8 : Bool = false

    Array of Byte can be

    saved in the optimized

    data area.

    New

    Page 29

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Comparison of UDT tags

    Functions

    • Two variables of the same PLC data type can be

    compared to each other.

    • Check for consistency and inconsistency

    • Available in STL, SCL, LAD, FBD

    Benefits

    • Symbolic programming using structured variables is now

    possible without restrictions and with optimal runtime

    performance.

    S7-1200 S7-300/400/WinAC

    Page 30

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Multi-lingual texts on the PLC

    Functions

    • Alarm texts and comments in the user program are

    loaded* onto the controller in 3 languages.

    Benefits

    • Web server and display can display alarms in up to three

    languages.

    • Translations are retained when downloaded/uploaded.

    • HMI Code Viewer and Graph-Viewer show the comments

    and the code in three languages.

    • Notes:

    • Applies to S7-1500, 2 languages for S7-1200

    • The alarms are loaded into the work memory. The contents are loaded into

    the load memory.

    Alarms and comments in three languages

    S7-1500 S7-1200 S7-300/400/WinAC

    Page 31

  • Unrestricted © Siemens AG 2016

    Recursive block call in SCL

    • Already available for LAD/FBD/STL

    • For S7-1200/1500

    Multiple assignment:

    • Easy assignment of a value to any number

    of tags (e.g. initialization)

    New arithmetic functions:

    • +=, -=, *=, /=

    • For S7-1200/1500

    SIMATIC STEP 7 in the TIA Portal – Language innovations

    Collection of useful functional extensions

    FC/FB

    Page 32

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 33

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    S7-1500

    SIMATIC STEP 7 in the TIA Portal – New and improved system functions

    Access to alarm texts from the user program

    Functions

    Virtual HMI - Same functional scope as

    SIMATIC HMI:

    • Subscription for specific display classes

    (filter option)

    • Selection of up to 3 languages

    Benefits

    Easy connection of third-party products

    to the alarm system of the S7-1500

    S7-1200 S7-300/400/WinAC

    Alarm server

    • System diagnostics

    • Program_Alarm

    • S7-Graph

    • ProDiag

    Page 34

    Data block

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 35

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Online

    DB-Editor

    Functions

    • Re-initialization of actual values with

    start values of the DB

    • Re-initialization of actual values of multiple DBs

    with the snapshot (also entire PLC)

    • Redesign of the icons

    Overwrite offline values in the ES (snap shot)

    Overwrite online values in the PLC

    Transfer only of offline values

    Benefits

    • Quick reset of the application to a defined state

    • Quick restoration of the application after upgrade or PLC

    replacement

    Page 36

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – Online

    Monitoring of structures in the block status

    Functions

    • A new "Monitor value" tab in the inspector window enables

    the monitoring of structures on the block as well as their

    call environment.

    • Context-sensitive selection

    • For InOut interconnections, both the transferred and the

    returned value are displayed.

    Benefits

    • Fast troubleshooting when values of a structure variable

    change with several accesses per cycle

    • Clear representation of actual values of a structure tag

    Page 37

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 38

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Innovated cross reference list

    Functions

    • HMI and PLC accesses at a glance

    • New types of cross references (types-instances,…)

    • Overlapping accesses on PLC tags

    • User input of tags (Go To... functionality)

    • Check several tags at the same time

    • Support of know how protected blocks

    • Several filtering options

    Benefits

    • Quick analysis of the program structure

    • Quick identification of errors

    Seite 39

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Trace – Repeated measurements/ recording onto a memory card

    Objective

    • Automated recording without the TIA Portal

    • Automated repeated measuring

    • Troubleshooting in systems

    • Persistent storage of measurements (on memory card)

    Configuration and display

    • Repeated measuring

    • Record N measurements according to trigger conditions

    • Reactivate measurement after saving

    • Optional: overwrite the oldest measurement

    • Up to 1000 measurements

    • Webserver S7-1500

    • Only measurements stored on the memory card are displayed;

    no configuration

    • Saving as csv file and display of csv files

    • Automatic naming of measurements - including a time stamp

    • Measurements will be saved in a separate folder

    Page 50

    TIA Portal Webserver

    RAM

    CPU

    New

    S7-1500 S7-1200 S7-300/400/WinAC

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Trace – Combining measurements

    Objective

    • Displaying different measurements in a common diagram

    Typical applications

    • Comparative analysis of repeated measurements (controller optimization)

    • Combining simultaneous measurements from different devices (S7-1200, S7-1500, drives)

    Page 41

    Combining

    measurements in PNV

    Single measurements Combined measurement

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Trace – Combining measurements - Functionality

    Chronological alignment of measurements

    • Measurements can be aligned according to the time axis

    • Orientation according to trigger pulse, first/last sample

    • Orientation according to time stamps

    • Additional fine adjustment

    Display options (as with a single measurement)

    • 16 signals can be displayed at a time

    • Signals can be grouped

    • Assigned track record or display in a shared diagram

    • Display of time stamps or relative to trigger pulse

    Page 42

    Each measurement can be timed and moved

    accordingly.

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Global search

    Searching for user texts

    • Separate editor for global search

    • All of the project data is indexed for quick searches.

    Functions

    • Start via menu, toolbar, shortcut, context menu

    • Textual search with results list, incl. preview of places found

    • Structured and sortable

    • "Go to“ option form the list to the place found in the editor

    • Flexible search request (Infix, Suffix, Wildcards)

    • Scope of search can be limited

    Scope of search

    • PLC (SCL, STL, LAD/FBD, GRAPH, tags)

    incl. Failsafe & Trace

    • HMI (screens, scripts, recipes, etc.)

    Page 43

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Automation Software Updater – Function extensions

    Functions

    • Corporate Update Server: Selected TIA Portal Updates

    can be stored on a local server and then be distributed via

    the local network.

    • Updates will be distributed through standard Microsoft

    server services (IIS, BITS).

    Benefits

    • Automation Update Server: Central update management

    within the company

    • Reduction of the needed internet bandwidth

    • Enhanced security, as there is no need for the TIA Portal

    station to be connected to the internet

    Page 44

    TIA Portal Engineering Stationen

    Siemens Update Server

    Corporate Update Server

    New

    Internet

    Intranet

    TIA Updater Tool

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Import and export of the TIA Portal settings

    Functions

    • Manual import and export of the global TIA Portal settings

    • Central administration of the global settings

    Benefits

    • Easy transfer of the global TIA Portal settings between

    different installations/PCs

    • TIA Portal settings that are valid company-wide can be

    easily rolled out to any number of TIA Portal users

    • Identical TIA Portal behavior and appearance at all

    managed TIA Portal installations

    Page 45

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    New help as information system

    Functions

    • New help system based on HTML


    • Expanded search function

    • Programming examples for all

    PLC applications

    • New start page and synchronization

    with the online support page

    Benefits

    • Several search results can be

    displayed in separate tabs at the

    same time

    • Objects can be located more quickly

    thanks to device-granular search

    options.

    Page 46

    Search Navigation Content

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal – System functions

    Collection of useful functional extensions

    Page 47

    Archiving and retrieval

    • Backup copy or ZIP-archive

    • Delete recoverable data

    • Add date/time to filename

    Grouping of windows

    • New button in the status bar

    Sorting keyboard shortcuts

    • The list of keyboard shortcuts can be sorted

    for a better overview (settings keyboard

    operation)

    New

    New

    New

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal

    Highlights of STEP 7 V14

    Page 48

    6. System functions

    5. Online functions

    4. Alarming

    3. Language innovations

    2. Editor functions

    1. Hardware configuration

    Monitoring of structures in the block

    Re-initialization with start and snapshot

    values,

    new design of the toolbar in the DB editor

    Grouping of devices

    Hardware profiles, ….

    SCL networks in LAD/FBD

    Hide block parameters (LAD/FBD)

    SCL regions

    Array(*)

    Array of multi-instances

    Evaluate program changes using checksums

    Multi lingual texts on the PLC

    Open use of alarm texts

    Global search

    Innovated information system

    Export/import of settings

    7. Simulation

    Quick PLCSIM startup in

    compact mode

    Easy device exchange, …

    Details

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal - Simulation

    S7-PLCSIM - Overview

    Functions

    • New compact view

    • No simulation project needed to start application

    • New CPUs:

    • S7-1200F incl. F I/Os

    • S7-1500 Compact-CPUs

    • T-CPU incl. motion functions

    • Drag & Drop of hardware modules into the Sim-

    table

    • Simulation of the decentralized periphery

    • Undo/Redo-feature

    • Functional extensions for sequences

    Page 49

    S7-1500 S7-1200 S7-300/400/WinAC

  • Unrestricted © Siemens AG 2016

    SIMATIC STEP 7 in the TIA Portal - Simulation

    S7-PLCSIM - Sequences

    Functions

    • Importing CPU traces as a sequence

    • Starting a sequence using trigger handling

    • Activating/Deactivating of actions

    • Delay times for sequences

    Benefits

    • Simple analysis of parameters in the laboratory

    • Simple adjustment of the sequence to fit new

    requirements

    Page 50

    Neu

    Neu

    S7-1500 S7-1200 S7-300/400/WinAC

  • Unrestricted © Siemens AG 2016

    Thank you for your attention!

    Page 51

    siemens.com/tia-portal