Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
* See Mechanical Data
Types available:
*Dimension is given in the table below
Double secondarySingle secondary
A±0.5mm
a±0.5mm
c*
b ±0.5mm*
d*
B*±0.5mm
H*
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
1- age-p
SecondaryVoltage
[V]
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
<400
VoltageDrop
[%]
15
Transformer dimensions [mm]
A B H a b c d
12
10
10
10
10
10
10
10
10
8
8
7
7
7
7
6.5
5.5
4
<400 15 66 79 75 55 47.5 4.2 5.5
7
8
8
8
2.CKL Series
Order code
9.xxx.E06634.xxx
9.xxx.E07526.xxx
9.xxx.E07532.xxx
9.xxx.E07535.xxx
9.xxx.E07541.xxx
9.xxx.E08429.xxx
9.xxx.E08438.xxx
9.xxx.E08441.xxx
9.xxx.E09635.xxx
9.xxx.E09645.xxx
9.xxx.E09650.xxx
9.xxx.E09660.xxx
9.xxx.E10838.xxx
9.xxx.E10845.xxx
9.xxx.E10850.xxx
9.xxx.E10860.xxx
9.xxx.E12041.xxx
9.xxx.E12053.xxx
9.xxx.E12061.xxx
9.xxx.E12073.xxx
9.xxx.E15049.xxx
9.xxx.E15066.xxx
9.xxx.E15092.xxx
9.xxx.E06623.xxx
PrimaryVoltage
[V]
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
<600
RatedPower
[VA]
50
50
63
75
85
80
90
100
180
200
300
400
450
500
630
800
1000
250
30
150
200
250
300
180
Standardoffer
- page -
- 2 -
66 90 75 55 58.5 4.2 5.5
75 82 80 62.5 51.0 4.2 5.5
75 78 80 62.5 57.0 4.2 5.5
75 91 80 62.5 60.0 4.2 5.5
75 97 80 62.5 66.0 4.2 5.5
84 85 88 70.0 53.5 4.2 5.5
84 94 88 70.0 62.5 4.2 5.5
84 97 88 70.0 65.5 4.2 5.5
96 92 95 80.0 61.5 5.2 7.5
96 104 95 80.0 71.5 5.2 7.5
96 109 95 80.0 76.5 5.2 7.5
96 119 95 80.0 86.5 5.2 7.5
108 95 105 90.0 64.5 5.2 7.5
108 102 105 90.0 71.5 5.2 7.5
108 107 105 90.0 76.5 5.2 7.5
108 117 105 90.0 80.5 5.2 7.5
120 98 115 100.0 70.0 6.2 9.5
120 110 115 100.0 82.0 6.2 9.5
120 118 115 100.0 90.0 6.2 9.5
120 130 115 100.0 102.0 6.2 9.5
150 131 150 125.0 82.5 8.2 11.5
150 148 150 125.0 98.5 8.2 11.5
150 174 150 125.0 124.5 8.2 11.5
-
- 4 -
- 6 -
-
-
- 8 -
-
- 10 -
-12-
-
- 14 -
- 16 -
-
-
-
-
- 18 -
- 20 -
-
- 22 -
- 24 -
- 26 -
- 28 -
S2.C
KL
Seri
es
2 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 30VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 700 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2.CKL Series
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
302.50
1.25
1.43
1.25
0.63
0.83
0.71
0.63
0.63
13.8 SIT 2.CKL.E06623.209
* See Mechanical Data
VoltageDrop
[%]
15
EI66/23
www.stf-trafo.comwww.stf.rs
V.13.1 by Stevanovic trafoÓ
30
30
30
30
30
30
30
30
2.CKL.E06623.210
2.CKL.E06623.215
2.CKL.E06623.217
2.CKL.E06623.218
2.CKL.E06623.221
2.CKL.E06623.223
2.CKL.E06623.225
2.CKL.E06623.240
115
230
0.26
0.13
30
30
2.CKL.E06623.260
2.CKL.E06623.270
30
30
30
30
30
30
30
30
30
30
30
2.CKL.E06623.409
2.CKL.E06623.410
2.CKL.E06623.415
2.CKL.E06623.417
2.CKL.E06623.418
2.CKL.E06623.421
2.CKL.E06623.423
2.CKL.E06623.425
2.CKL.E06623.440
2.CKL.E06623.460
2.CKL.E06623.470
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.08 30 2.CKL.E06623.280
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
30 2.CKL.E06623.480400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
2.50
1.25
1.43
1.25
0.63
0.83
0.71
0.63
0.63
0.26
0.13
0.08
t ftransformers
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
79 / 47.5
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
2 x 13.8
24.2
27.6
2 x 27.6
41.4
48.3
55.2
48.3, 55.2
132
264
460
13.8
2 x 13.8
24.2
27.6
2 x 27.6
41.4
48.3
55.2
48.3, 55.2
132
264
460
3- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI66/23
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
66.0±0.5mm
55.0±0.5mm
4.2mm
C*±0.5mm
5.5mm
B*±0.5mm
75.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 30 79 / 47.5<400 9.xxx.E06623.xxx
VoltageDrop
[%]
15
50
Types available on request:
9.xxx.E06634.xxx<600 <400 IT
IT
15
Width*
B / C[mm]
90 / 58.5
*See Mechanical Data
S2.C
KL
Seri
es
4 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 50VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 980 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
504.17
2.08
2.38
2.08
1.04
1.39
1.19
1.04
1.04
SIT 2.CKL.E07526.209
* See Mechanical Data
VoltageDrop
[%]
12
EI75/26
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2107526
2.CKL.E0 .2157526
2.CKL.E0 .2177526
2.CKL.E0 .2187526
2.CKL.E0 .2217526
2.CKL.E0 .2237526
2.CKL.E0 .2257526
2.CKL.E0 .2407526
115
230
0.43
0.22
2.CKL.E0 .2607526
2.CKL.E0 .2707526
2.CKL.E0 .4097526
2.CKL.E0 .4107526
2.CKL.E0 .4157526
2.CKL.E0 .4177526
2.CKL.E0 .4187526
2.CKL.E0 .4217526
2.CKL.E0 .4237526
2.CKL.E0 .4257526
2.CKL.E0 .4407526
2.CKL.E0 .4607526
2.CKL.E0 .4707526
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.13 2.CKL.E0 .2807526
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4807526400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
82 / 51.013.4
2 x 13.4
23.5
26.9
2 x 26.9
40.3
47.0
53.8
47.0, 53.8
129
258
448
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
4.17
2.08
2.38
2.08
1.04
1.39
1.19
1.04
1.04
0.43
0.22
0.13
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
82 / 51.0
13.4
2 x 13.4
23.5
26.9
2 x 26.9
40.3
47.0
53.8
47.0, 53.8
129
258
448
5- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI75/26
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
75.0±0.5mm
62 5±0.5mm.
4.2mm
C*±0.5mm
5.5mm
B*±0.5mm
80.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 50 82 / 51.0<400
VoltageDrop
[%]
12
63
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
88 / 57.0
*See Mechanical Data
<600 75 91 / 60.0<400 10
85<600 <400 IT
IT
10 97 / 66.0
9.xxx.E07526.xxx
9.xxx.E07532.xxx
9.xxx.E07535.xxx
9.xxx.E07541.xxx
S2.C
KL
Seri
es
6 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 63VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 1200 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
635.25
2.63
3.00
2.63
1.31
1.75
1.50
1.31
1.31
SIT 2.CKL.E07532.209
* See Mechanical Data
VoltageDrop
[%]
10
EI75/32
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2107532
2.CKL.E0 .2157532
2.CKL.E0 .2177532
2.CKL.E0 .2187532
2.CKL.E0 .2217532
2.CKL.E0 .2237532
2.CKL.E0 .2257532
2.CKL.E0 .2407532
115
230
0.55
0.27
2.CKL.E0 .2607532
2.CKL.E0 .2707532
2.CKL.E0 .4097532
2.CKL.E0 .4107532
2.CKL.E0 .4157532
2.CKL.E0 .4177532
2.CKL.E0 .4187532
2.CKL.E0 .4217532
2.CKL.E0 .4237532
2.CKL.E0 .4257532
2.CKL.E0 .4407532
2.CKL.E0 .4607532
2.CKL.E0 .4707532
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.16 2.CKL.E0 .2807532
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4807532400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
88 / 57.0
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
5.25
2.63
3.00
2.63
1.31
1.75
1.50
1.31
1.31
0.55
0.27
0.16
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
88 / 57.0
7- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI75/32
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
75.0±0.5mm
62 5±0.5mm.
4.2mm
C*±0.5mm
5.5mm
B*±0.5mm
80.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 50<400
VoltageDrop
[%]
12
63
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
*See Mechanical Data
<600 75<400 10
85<600 <400 IT
IT
10
9.xxx.E07526.xxx
9.xxx.E07532.xxx
9.xxx.E07535.xxx
9.xxx.E07541.xxx
82 / 51.0
88 / 57.0
91 / 60.0
97 / 66.0
S2.C
KL
Seri
es
8 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 80VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 1430 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
806.67
3.33
3.81
3.33
1.67
2.22
1.90
1.67
1.67
SIT 2.CKL.E08429.209
* See Mechanical Data
VoltageDrop
[%]
10
EI84/29
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2108429
2.CKL.E0 .2158429
2.CKL.E0 .2178429
2.CKL.E0 .2188429
2.CKL.E0 .2218429
2.CKL.E0 .2238429
2.CKL.E0 .2258429
2.CKL.E0 .2408429
115
230
0.70
0.35
2.CKL.E0 .2608429
2.CKL.E0 .2708429
2.CKL.E0 .4098429
2.CKL.E0 .4108429
2.CKL.E0 .4158429
2.CKL.E0 .4178429
2.CKL.E0 .4188429
2.CKL.E0 .4218429
2.CKL.E0 .4238429
2.CKL.E0 .4258429
2.CKL.E0 .4408429
2.CKL.E0 .4608429
2.CKL.E0 .4708429
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.20 2.CKL.E0 .2808429
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4808429400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
85 / 53.5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
6.67
3.33
3.81
3.33
1.67
2.22
1.90
1.67
1.67
0.70
0.35
0.20
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
85 / 53.5
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
9- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI84/29
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
84.0±0.5mm
70 0±0.5mm.
4.2mm
C*±0.5mm
5.5mm
B*±0.5mm
88.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 80 85 / 53.5<400
VoltageDrop
[%]
10
90
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
94 / 62.5
*See Mechanical Data
<600 100 97 / 65.5<400 10 IT
9.xxx.E08429.xxx
9.xxx.E08438.xxx
9.xxx.E08441.xxx
S2.C
KL
Seri
es
10 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 100VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 1860 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
1008.33
4.17
4.76
4.17
2.08
2.78
2.38
2.08
20.8
SIT 2.CKL.E08441.209
* See Mechanical Data
VoltageDrop
[%]
10
EI84/41
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2108441
2.CKL.E0 .2158441
2.CKL.E0 .2178441
2.CKL.E0 .2188441
2.CKL.E0 .2218441
2.CKL.E0 .2238441
2.CKL.E0 .2258441
2.CKL.E0 .2408441
115
230
0.87
0.43
2.CKL.E0 .2608441
2.CKL.E0 .2708441
2.CKL.E0 .4098441
2.CKL.E0 .4108441
2.CKL.E0 .4158441
2.CKL.E0 .4178441
2.CKL.E0 .4188441
2.CKL.E0 .4218441
2.CKL.E0 .4238441
2.CKL.E0 .4258441
2.CKL.E0 .4408441
2.CKL.E0 .4608441
2.CKL.E0 .4708441
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.25 2.CKL.E0 .2808441
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4808441400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
97 / 65.5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8.33
4.17
4.76
4.17
2.08
2.78
2.38
2.08
20.8
0.87
0.43
0.25
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
97 / 65.5
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
11- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI84/41
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
84.0±0.5mm
70 0±0.5mm.
4.2mm
C*±0.5mm
5.5mm
B*±0.5mm
88.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 80<400
VoltageDrop
[%]
10
90
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
*See Mechanical Data
<600 100<400 10 IT
9.xxx.E08429.xxx
9.xxx.E08438.xxx
9.xxx.E08441.xxx
85 / 53.5
94 / 62.5
97 / 65.5
S2.C
KL
Seri
es
12 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 150VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 2280 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
15012.5
6.25
7.14
6.25
3.13
4.17
3.57
3.13
3.13
SIT 2.CKL.E09635.209
* See Mechanical Data
VoltageDrop
[%]
10
EI96/35
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2109635
2.CKL.E0 .2159635
2.CKL.E0 .2179635
2.CKL.E0 .2189635
2.CKL.E0 .2219635
2.CKL.E0 .2239635
2.CKL.E0 .2259635
2.CKL.E0 .2409635
115
230
1.30
0.65
2.CKL.E0 .2609635
2.CKL.E0 .2709635
2.CKL.E0 .4099635
2.CKL.E0 .4109635
2.CKL.E0 .4159635
2.CKL.E0 .4179635
2.CKL.E0 .4189635
2.CKL.E0 .4219635
2.CKL.E0 .4239635
2.CKL.E0 .4259635
2.CKL.E0 .4409635
2.CKL.E0 .4609635
2.CKL.E0 .4709635
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.38 2.CKL.E0 .2809635
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4809635400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
92 / 61.5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
13.2
2 x 13.2
23.1
26.4
2 x 26.4
39.6
46.2
52.8
46.2, 52.8
127
253
440
12.5
6.25
7.14
6.25
3.13
4.17
3.57
3.13
3.13
1.30
0.65
0.38
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
92 / 61.5
13- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI96/35
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
96.0±0.5mm
80 0±0.5mm.
5.2mm
C*±0.5mm
7.5mm
B*±0.5mm
95.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 150<400
VoltageDrop
[%]
10
180
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
104 / 71.5
*See Mechanical Data
<600 200<400 8
250<600 <400 IT
IT
8
9.xxx.E09635.xxx
9.xxx.E09645.xxx
9.xxx.E09650.xxx
9.xxx.E09660.xxx
92 / 61.5
109 / 76.5
119 / 86.5
S2.C
KL
Seri
es
14 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 200VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 3020 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
20016.7
8.33
9.52
8.33
4.17
5.56
4.76
4.17
4.17
SIT 2.CKL.E09650.209
* See Mechanical Data
VoltageDrop
[%]
8
EI96/50
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2109650
2.CKL.E0 .2159650
2.CKL.E0 .2179650
2.CKL.E0 .2189650
2.CKL.E0 .2219650
2.CKL.E0 .2239650
2.CKL.E0 .2259650
2.CKL.E0 .2409650
115
230
1.74
0.87
2.CKL.E0 .2609650
2.CKL.E0 .2709650
2.CKL.E0 .4099650
2.CKL.E0 .4109650
2.CKL.E0 .4159650
2.CKL.E0 .4179650
2.CKL.E0 .4189650
2.CKL.E0 .4219650
2.CKL.E0 .4239650
2.CKL.E0 .4259650
2.CKL.E0 .4409650
2.CKL.E0 .4609650
2.CKL.E0 .4709650
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.50 2.CKL.E0 .2809650
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4809650400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
109 / 76.5
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
13.0
2 x 13.0
22.7
25.9
2 x 25.9
38.9
45.4
51.8
45.4, 51.8
124
248
432
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
16.7
8.33
9.52
8.33
4.17
5.56
4.76
4.17
4.17
1.74
0.87
0.50
13.0
2 x 13.0
22.7
25.9
2 x 25.9
38.9
45.4
51.8
45.4, 51.8
124
248
432
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
109 / 76.5
15- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI96/50
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
96.0±0.5mm
80 0±0.5mm.
5.2mm
C*±0.5mm
7.5mm
B*±0.5mm
95.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 150<400
VoltageDrop
[%]
10
180
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
*See Mechanical Data
<600 200<400 8
250<600 <400 IT
IT
8
9.xxx.E09635.xxx
9.xxx.E09645.xxx
9.xxx.E09650.xxx
9.xxx.E09660.xxx
104 / 71.5
92 / 61.5
109 / 76.5
119 / 86.5
S2.C
KL
Seri
es
16 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 250VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 3520 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
25020.8
10.4
11.9
10.4
5.21
6.94
5.95
5.21
5.21
SIT 2.CKL.E09660.209
* See Mechanical Data
VoltageDrop
[%]
8
EI96/60
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E0 .2109660
2.CKL.E0 .2159660
2.CKL.E0 .2179660
2.CKL.E0 .2189660
2.CKL.E0 .2219660
2.CKL.E0 .2239660
2.CKL.E0 .2259660
2.CKL.E0 .2409660
115
230
2.17
1.09
2.CKL.E0 .2609660
2.CKL.E0 .2709660
2.CKL.E0 .4099660
2.CKL.E0 .4109660
2.CKL.E0 .4159660
2.CKL.E0 .4179660
2.CKL.E0 .4189660
2.CKL.E0 .4219660
2.CKL.E0 .4239660
2.CKL.E0 .4259660
2.CKL.E0 .4409660
2.CKL.E0 .4609660
2.CKL.E0 .4709660
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.63 2.CKL.E0 .2809660
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E0 .4809660400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
119 / 86.513.0
2 x 13.0
22.7
25.9
2 x 25.9
38.9
45.4
51.8
45.4, 51.8
124
248
432
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
13.0
2 x 13.0
22.7
25.9
2 x 25.9
38.9
45.4
51.8
45.4, 51.8
124
248
432
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
119 / 86.5
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
20.8
10.4
11.9
10.4
5.21
6.94
5.95
5.21
5.21
2.17
1.09
0.63
17- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
EI96/60
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
96.0±0.5mm
80 0±0.5mm.
5.2mm
C*±0.5mm
7.5mm
B*±0.5mm
95.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 150<400
VoltageDrop
[%]
10
180
Types available on request:
<600 <400 IT
IT
10
Width*
B / C[mm]
*See Mechanical Data
<600 200<400 8
250<600 <400 IT
IT
8
9.xxx.E09635.xxx
9.xxx.E09645.xxx
9.xxx.E09650.xxx
9.xxx.E09660.xxx
104 / 71.5
92 / 61.5
109 / 76.5
119 / 86.5
S2.C
KL
Seri
es
18 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 300VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 4050 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
30025.0
12.5
14.3
12.5
6.25
8.33
7.14
6.25
6.25
SIT 2.CKL.E12041.209
* See Mechanical Data
VoltageDrop
[%]
7
EI120/41
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21012041
2.CKL.E .21512041
2.CKL.E .21712041
2.CKL.E .21812041
2.CKL.E .22112041
2.CKL.E .22312041
2.CKL.E .22512041
2.CKL.E .24012041
115
230
2.61
1.30
2.CKL.E .26012041
2.CKL.E .27012041
2.CKL.E .40912041
2.CKL.E .41012041
2.CKL.E .41512041
2.CKL.E .41712041
2.CKL.E .41812041
2.CKL.E .42112041
2.CKL.E .42312041
2.CKL.E .42512041
2.CKL.E .44012041
2.CKL.E .46012041
2.CKL.E .47012041
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 0.75 2.CKL.E .28012041
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48012041400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
98 / 68.512.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
3007
25.0
12.5
14.3
12.5
6.25
8.33
7.14
6.25
6.25
2.61
1.30
0.75
12.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
98 / 68.5
19- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
120.0±0.5mm
100 0±0.5mm.
6.2mm
C*±0.5mm
9.5mm
B*±0.5mm
115.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 300<400
VoltageDrop
[%]
7
400
Types available on request:
<600 <400 IT
IT
7
Width*
B / C[mm]
*See Mechanical Data
<600 450<400 7
500<600 <400 IT
IT
7
98 / 70.0 9.xxx.E12041.xxx
9.xxx.E12053.xxx
9.xxx.E12061.xxx
9.xxx.E12073.xxx
EI120/41
110 / 82.0
130 / 102.0
118 / 90.0
S2.C
KL
Seri
es
20 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 400VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 5200 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
40033.3
16.7
19.0
16.7
8.33
11.11
9.52
8.33
8.33
SIT 2.CKL.E12053.209
* See Mechanical Data
VoltageDrop
[%]
7
EI120/53
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21012053
2.CKL.E .21512053
2.CKL.E .21712053
2.CKL.E .21812053
2.CKL.E .22112053
2.CKL.E .22312053
2.CKL.E .22512053
2.CKL.E .24012053
115
230
3.48
1.74
2.CKL.E .26012053
2.CKL.E .27012053
2.CKL.E .40912053
2.CKL.E .41012053
2.CKL.E .41512053
2.CKL.E .41712053
2.CKL.E .41812053
2.CKL.E .42112053
2.CKL.E .42312053
2.CKL.E .42512053
2.CKL.E .44012053
2.CKL.E .46012053
2.CKL.E .47012053
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 1.00 2.CKL.E .28012053
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48012053400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
110 / 80.512.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
33.3
16.7
19.0
16.7
8.33
11.11
9.52
8.33
8.33
3.48
1.74
1.00
12.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
110 / 80.5
21- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
120.0±0.5mm
100 0±0.5mm.
6.2mm
C*±0.5mm
9.5mm
B*±0.5mm
115.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 300<400
VoltageDrop
[%]
7
400
Types available on request:
<600 <400 IT
IT
7
Width*
B / C[mm]
*See Mechanical Data
<600 450<400 7
500<600 <400 IT
IT
7
9.xxx.E12041.xxx
9.xxx.E12053.xxx
9.xxx.E12061.xxx
9.xxx.E12073.xxx
EI120/53
98 / 70.0
110 / 82.0
130 / 102.0
118 / 90.0
S2.C
KL
Seri
es
22 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 500VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 6550 g
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
50041.7
20.8
23.8
20.8
10.4
13.9
11.9
10.4
10.4
SIT 2.CKL.E12073.209
* See Mechanical Data
VoltageDrop
[%]
7
EI120/73
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21012073
2.CKL.E .21512073
2.CKL.E .21712073
2.CKL.E .21812073
2.CKL.E .22112073
2.CKL.E .22312073
2.CKL.E .22512073
2.CKL.E .24012073
115
230
4.35
2.17
2.CKL.E .26012073
2.CKL.E .27012073
2.CKL.E .40912073
2.CKL.E .41012073
2.CKL.E .41512073
2.CKL.E .41712073
2.CKL.E .41812073
2.CKL.E .42112073
2.CKL.E .42312073
2.CKL.E .42512073
2.CKL.E .44012073
2.CKL.E .46012073
2.CKL.E .47012073
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 1.25 2.CKL.E .28012073
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48012073400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
130 / 100.512.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
12.8
2 x 12.8
22.5
25.7
2 x 25.7
38.5
44.9
51.4
44.9, 51.4
123
246
428
41.7
20.8
23.8
20.8
10.4
13.9
11.9
10.4
10.4
4.35
2.17
1.25
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
500 130 / 100.5
23- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
120.0±0.5mm
100 0±0.5mm.
6.2mm
C*±0.5mm
9.5mm
B*±0.5mm
115.0
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
<600 300<400
VoltageDrop
[%]
7
400
Types available on request:
<600 <400 IT
IT
7
Width*
B / C[mm]
*See Mechanical Data
<600 450<400 7
500<600 <400 IT
IT
7
9.xxx.E12041.xxx
9.xxx.E12053.xxx
9.xxx.E12061.xxx
9.xxx.E12073.xxx
EI120/73
98 / 70.0
110 / 82.0
130 / 102.0
118 / 90.0
S2.C
KL
Seri
es
24 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 630VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 8,3 kg
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
SIT 2.CKL.E15049.209
* See Mechanical Data
VoltageDrop
[%]
EI150/49
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21015049
2.CKL.E .21515049
2.CKL.E .21715049
2.CKL.E .21815049
2.CKL.E .22115049
2.CKL.E .22315049
2.CKL.E .22515049
2.CKL.E .24015049
115
230
2.CKL.E .26015049
2.CKL.E .27015049
2.CKL.E .40915049
2.CKL.E .41015049
2.CKL.E .41515049
2.CKL.E .41715049
2.CKL.E .41815049
2.CKL.E .42115049
2.CKL.E .42315049
2.CKL.E .42515049
2.CKL.E .44015049
2.CKL.E .46015049
2.CKL.E .47015049
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 2.CKL.E .28015049
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48015049400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
131 / 82.56306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
6306.5
52.5
26.3
30.0
26.3
13.1
17.5
15.0
13.1
13.1
5.48
2.74
1.58
12.8
2 x 12.8
22.4
25.6
2 x 25.6
38.3
44.7
51.1
44.7, 51.1
123
245
426
52.5
26.3
30.0
26.3
13.1
17.5
15.0
13.1
13.1
5.48
2.74
1.58
12.8
2 x 12.8
22.4
25.6
2 x 25.6
38.3
44.7
51.1
44.7, 51.1
123
245
426
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
131 / 82.5
25- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
150.0±0.5mm
125 0±0.5mm.
8.2mm
C*±0.5mm
11.5mm
B*±0.5mm
150.0
EI150/49
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
VoltageDrop
[%]
Types available on request:
Width*
B / C[mm]
*See Mechanical Data
9.xxx.E15049.xxx
9.xxx.E15066.xxx
9.xxx.E15092.xxx
IT
IT
IT
131 / 82.5
148 / 98.5
174 / 124.5
630
800
1000
<400 6.5
<400 5.5
<400 4
<600
<600
<600
S2.C
KL
Seri
es
26 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 800VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 10,4 kg
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
SIT 2.CKL.E15066.209
* See Mechanical Data
VoltageDrop
[%]
EI150/66
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21015066
2.CKL.E .21515066
2.CKL.E .21715066
2.CKL.E .21815066
2.CKL.E .22115066
2.CKL.E .22315066
2.CKL.E .22515066
2.CKL.E .24015066
115
230
2.CKL.E .26015066
2.CKL.E .27015066
2.CKL.E .40915066
2.CKL.E .41015066
2.CKL.E .41515066
2.CKL.E .41715066
2.CKL.E .41815066
2.CKL.E .42115066
2.CKL.E .42315066
2.CKL.E .42515066
2.CKL.E .44015066
2.CKL.E .46015066
2.CKL.E .47015066
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 2.CKL.E .28015066
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48015066400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
148 / 98.58005.566.7
33.3
38.1
33.3
16.7
22.2
19.1
16.7
16.7
6.96
3.48
2.00
12.7
2 x 12.7
22.2
25.3
2 x 25.3
38.0
44.3
50.6
44.3, 50.6
121
243
422
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
148 / 98.58005.5
66.7
33.3
38.1
33.3
16.7
22.2
19.1
16.7
16.7
6.96
3.48
2.00
12.7
2 x 12.7
22.2
25.3
2 x 25.3
38.0
44.3
50.6
44.3, 50.6
121
243
422
27- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
150.0±0.5mm
125 0±0.5mm.
8.2mm
C*±0.5mm
11.5mm
B*±0.5mm
150.0
EI150/66
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
VoltageDrop
[%]
Types available on request:
Width*
B / C[mm]
*See Mechanical Data
9.xxx.E15049.xxx
9.xxx.E15066.xxx
9.xxx.E15092.xxx
IT
IT
IT
630
800
1000
<400 6.5
<400 5.5
<400 4
<600
<600
<600
131 / 82.5
148 / 98.5
174 / 124.5
S2.C
KL
Seri
es
28 - age-p
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
·
·
·
· °
·
·
·
·
·
·
·
·
Rated power: 1000VA
Safety Isolating & Isolating Transformers
Non-short-circuit proof
Ambient temperature 40 C
Temperature Class B
Self-extinguishing plastics UL94HB
Degree of protection IP00
Clamp Terminals for Currents up to 60A
Moisture protected by varnish
High electrical safety and long service-lifefeatures
In compliance with: EN61558-1, EN61558-2-4,EN61558-2-6
Weight: 13,3 kg
Approvals:
Electrical Data:
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
2. SeriesCKL
Order code
Safety Isolating /Isolating
transformers
[VA]
Width*
B / C[mm]
230
230
230
230
230
230
230
230
230
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
SIT 2.CKL.E15092.209
* See Mechanical Data
VoltageDrop
[%]
EI150/92
www.stf-trafo.comwww.stf.rs
V. by Stevanovic trafoÓ13.1
2.CKL.E .21015092
2.CKL.E .21515092
2.CKL.E .21715092
2.CKL.E .21815092
2.CKL.E .22115092
2.CKL.E .22315092
2.CKL.E .22515092
2.CKL.E .24015092
115
230
2.CKL.E .26015092
2.CKL.E .27015092
2.CKL.E .40915092
2.CKL.E .41015092
2.CKL.E .41515092
2.CKL.E .41715092
2.CKL.E .41815092
2.CKL.E .42115092
2.CKL.E .42315092
2.CKL.E .42515092
2.CKL.E .44015092
2.CKL.E .46015092
2.CKL.E .47015092
230
230
230
400
400
400
400
400
400
400
400
400
400
400
400 2.CKL.E .28015092
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
IT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
SIT
IT
IT
2.CKL.E .48015092400 IT
12
2 x 12
21
24
2 x 24
36
42
48
42, 48
115
230
400
t ftransformers
174 / 124.51000483.3
41.7
47.6
41.7
20.8
27.8
23.8
20.8
20.8
8.70
4.35
2.50
12.5
2 x 12.5
21.8
25.0
2 x 25.0
37.4
43.7
49.9
43.7, 49.9
120
240
416
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
174 / 124.510004
83.3
41.7
47.6
41.7
20.8
27.8
23.8
20.8
20.8
8.70
4.35
2.50
12.5
2 x 12.5
21.8
25.0
2 x 25.0
37.4
43.7
49.9
43.7, 49.9
120
240
416
29- age-pWe reserve right to change specifications, product descriptions, product quality, pricing and application at any time
without any notice and further obligation.
2.CKL SERIES
L Brackets Mounting Dry Type Power Transformer
2.C
KL
Seri
es
S t ftransformers
Possible Connection Types:
Double secondarySingle secondary
230-240V50-60Hz
Secondary
230-240V50-60Hz
DoubleVoltage
230-240V50-60Hz
Double Current
Mechanical Data:
*Transformer width is given in table with Electrical Data
Double secondarySingle secondary
150.0±0.5mm
125 0±0.5mm.
8.2mm
C*±0.5mm
11.5mm
B*±0.5mm
150.0
EI150/92
PrimaryVoltage
@ [A]
Secondary Voltage
With Load No Load
[V] [V][V]
RatedPower
[SIT / IT]
9.xxx Series
Order code
Safety Isolating /Isolating
transformers
[VA]
VoltageDrop
[%]
Types available on request:
Width*
B / C[mm]
*See Mechanical Data
9.xxx.E15049.xxx
9.xxx.E15066.xxx
9.xxx.E15092.xxx
IT
IT
IT
630
800
1000
<400 6.5
<400 5.5
<400 4
<600
<600
<600
131 / 82.5
148 / 98.5
174 / 124.5