RF Engineering and Custom Build Model Number: SRY-ODU201
V 0.0 E&OE
StingRay RF over Fibre Outdoor Unit
With hot-swap power supplies & fibre modules, LNB powering, local & remote control
The StingRay RF over Fibre Outdoor unit (ODU) is a robust
weatherproof (IP65 rated) enclosure which has been designed
to be wall or post mounted close to the antenna. It can
accommodate up to 10 Transmit or Receive 200 series StingRay
Fibre modules.
The transmit modules benefit from a high and wide dynamic
range with automatic link optimisation ensuring high quality
transmission. Resilience is provided by a full hot-swap, modular
design.
Benefits & features:
High resilience from dual
redundant, hot-swap power
supplies (1) & hot-swap CPU module
(3)
Full local (2) & remote control (5) &
monitoring
Up to 10 single or dual RX or TX
modules (4)
Fibre patch panel and splice tray
(6) provided for termination of the
incoming fibre cable
DIN rail allows for flexible power
connection (7)
Thermostat for operation below -20°
C & humidity detection (8)
Removable gland plate (9)
13/18V LNB powering & 22KHz tone
(provided on TX modules)
Typical applications:
Designed to be wall or post
mounted close to an antenna
Distribution of comms traffic across
site with minimal loss
Front of ODU - door closed
1
2
3
4
5
5
6
7
8
9
Internal of ODU - door open
RF Engineering and Custom Build
V 0.0 E&OE
ETL SYSTEMS LIMITED Coldwell Radio Station Madley Hereford England HR2 9NE
TELEPHONE +44 (0)1981 259020 EMAIL [email protected]
FACSIMILE +44 (0)1981 259021 WEB www.etlsystems.com
Model Number: SRY-ODU201
StingRay RF over Fibre Outdoor Unit (ODU)
Technical specifications and operating parameters
System Control
Local Control (Optional) LCD and keypad
Remote Control
Ethernet (RJ45)
Port,
10BaseT/100BaseT
x or optical,
including ETL
TCP/IP protocol,
SNMP & Web
Browser Interface
Optical Ethernet
connection 1310
nm, 10 km reach
bidirectional over
two single mode
optical fibres
Monitoring
Temperature, RF
power & optical
power
Locally or
remotely
Alarms Dry contact alarm port on rear panel
for PSU failure
Physical
Capacity Up to 10 200 series modules
RF Connector Options (As defined on the modules) BNC / SMA / F-type
Impedance Options (As defined on the modules)
50Ω / 75Ω
Dimensions 407 x 356 x 254 mm
Weight 21 kg
Colour White 00-E-55 semi-gloss
Environmental
Operating temperature -20 to 60˚C
Location Outdoor or indoor use
Storage temperature -40 to +80˚C
Humidity Internally 20-90% RH,
non-condensing
Internal
humidity
sensor
Altitude 10,000 ft / 3,000 m AMSL
Power
LNB Power Up to 500 mA
per module
Module must
support LNB
power
AC Power 85-264Vac
50/60Hz
Circuit breaker
protected
AC Consumption
<300 W all
channels
occupied
Total AC input
PSU Dual redundant Diode OR
Hot-swap PSU Yes
Fibre module options
Module Model # for
chassis above Type Capacity Frequency LNB Powering -20dB Monitor Port
SRY-TX-L1-201 Transmit Single 850-2450 MHz (L-Band)
SRY-RX-L1-202 Receive Single 850-2450 MHz (L-Band)
SRY-TX-L1-205 Transmit Dual 850-2450 MHz (L-Band)
SRY-RX-L1-206 Receive Dual 850-2450 MHz (L-Band)
SRY-TX-B2-207 Transmit Dual 50-2450 MHz (Broadband)