2
Strep A FIA Quidel | Rapid Diagnostics | quidel.com | 800.874.1517 | 858.552.1100 Enhanced performance and productivity Enhanced assay sensitivity WALK AWAY and READ NOW modes provide flexible workflow options Objective results in 5 minutes Record keeping flexibility Barcode scanner captures user and patient IDs Digital record of QC, calibration and patient results Transmission of data to EMR via LIS/Middleware Virena ® surveillance and remote data management capabilities Automatically captures patient de-identified results Generates, trends and maps disease prevalence through your organization year-round User can create reports and files for in-depth analysis and actionable response Rapid Strep A . . . brought to you by Sofia

Strep A - Quidel€¦ · WALK AWAY and READ NOW modes provide flexible workflow options Objective results in 5 minutes Record keeping flexibility Barcode scanner captures user and

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Strep A - Quidel€¦ · WALK AWAY and READ NOW modes provide flexible workflow options Objective results in 5 minutes Record keeping flexibility Barcode scanner captures user and

Strep A FIA

Quidel | Rapid Diagnostics | quidel.com | 800.874.1517 | 858.552.1100

Enhanced performance and productivityEnhanced assay sensitivity

WALK AWAY and READ NOW modes provide flexible workflow options

Objective results in 5 minutes

Record keeping flexibilityBarcode scanner captures user and patient IDs

Digital record of QC, calibration and patient results

Transmission of data to EMR via LIS/Middleware

Virena® surveillance and remote data management capabilitiesAutomatically captures patient de-identified results

Generates, trends and maps disease prevalence through your organization

year-round

User can create reports and files for in-depth analysis and actionable

response

Rapid Strep A . . . brought to you by Sofia

SS2025300EN00.qxp_Layout 1 12/13/16 4:37 PM Page 1

Page 2: Strep A - Quidel€¦ · WALK AWAY and READ NOW modes provide flexible workflow options Objective results in 5 minutes Record keeping flexibility Barcode scanner captures user and

Sofia Strep A FIA

Moderately complex

Accurate detection with throat swab samples

Excellent performance demonstrated at amulti-site study*

Room temperature storage

24-month shelf life from date of manufacture

Compatible with two transport media (seePackage Insert for details)

SL2000 | SS2025300EN01 (12/16)

Sofia Strep A FIA – 25 Test Kit: Catalog #20253

Fill to Line

SqueezeTop Bulb

PipetteOverflow

Sample

Reader

FLUA+B

Paper Feed

Eject

Print

STREP A

5

Procedure

Walk Away Mode – Walk away and multitask

Culture

Pos Neg Total

Sofia Pos 116 24 140

Sofia Neg 12 584 596

Total 128 608 736

Sofia Strep A FIA Results vs. Culture*

Source: Multi-center clinical field study conducted in eight distinct sites in the U.S. and two in

Australia. Samples included 736 patients.

*Refer to the Package Insert for additional performance claims.

STREP A

Reader

FLUA+B

STREP A

5 1

Read Now Mode – Batch multiple samples per hour

Sensitivity 90.6% (116/128)Specificity 96.1% (584/608)

SS2025300EN00.qxp_Layout 1 12/13/16 4:37 PM Page 2