14
Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 Submittal data Job name: Location: Purchaser: Order number: Engineer: Submitted to: For: Ref: Approval: Construction: Submitted by: Date: Unit designation: Schedule number: Model number: Unit data Cooling performance Total capacity MBH Sensible capacity MBH Outdoor design temperature °F DB/WB Total supply air CFM Temp. of air entering evaporator coil °F Power input req. (less blower motor) kW Heating performance Electric heat kW Gas-fired input cap. MBH Supply air blower performance Total supply air CFM Ext. static press. IWG Blower speed RPM Power output req. BHP Motor rating HP Power input req. kW Electrical data Power supply Total unit ampacity amps Max. overcurrent device __ fuse __ breaker amps Total unit weight Weight including factory-installed options lbs 5783171-TSD-A-0819 Revision: A-0819 2019-08-01 Johnson Controls Ducted Systems

Submittal Data Sheet: TempMaster Omni Choice CV15 to CV28

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Submittal Data Sheet: TempMaster® Omni™Choice CV15 to CV28

Submittal data

Job name: Location:Purchaser: Order number:Engineer:Submitted to: For: Ref: Approval: Construction:Submitted by: Date:Unit designation: Schedule number: Model number:

Unit data

Cooling performance

Total capacity MBHSensible capacity MBHOutdoor design temperature °F DB/WBTotal supply air CFMTemp. of air entering evaporator coil °FPower input req. (less blower motor) kW

Heating performance

Electric heat kWGas-fired input cap. MBH

Supply air blower performance

Total supply air CFMExt. static press. IWGBlower speed RPMPower output req. BHPMotor rating HPPower input req. kW

Electrical data

Power supplyTotal unit ampacity ampsMax. overcurrent device__ fuse __ breaker amps

Total unit weight

Weight including factory-installed options lbs

5783171-TSD-A-0819 Revision: A-0819

2019-08-01

Johnson Controls Ducted Systems

Factory-installed options

Coil/hail guard

Hinged and toolless access panels

Magna-Dry modulating hot gas reheat dehumidification

Aluminized steel gas heat exchanger

Stainless steel gas heat exchanger

Modulating gas heat

Stainless steel drain pan

E-Coat coil coating

MERV 8 filter

MERV 13 filter

Constant volume airflow

IntelliSpeed discrete fan control

Multi-zone variable air volume (VAV)

CRSZ control single zone VAV

High static indoor blower motor

Non-fused disconnect switch

Circuit breaker

Powered convenience outlet

Non-powered convenience outlet

High SCCR

Phase monitor

Electric heat

Manual outside air damper

Motorized outside air damper

Low leak economizer

Single or dual enthalpy economizer control

Barometric relief damper

Constant volume power exhaust

Modulating power exhaust

Air proving switch

Dirty filter switch

CO² sensor

Condensate overflow switch

Low ambient head pressure control

Supply and return air smoke detectors

Smart Equipment™ control communication card

Verasys

Field-installed accessories

Roof curb, 14-inch or 24-inch height

Burglar bars

Coil/hail guard

Flue exhaust extension

Propane conversion

High altitude kit for propane

High altitude kit for natural gas

Non-powered convenience outlet

Electric heat

Manual outside air damper

Motorized outside air damper

Low leak economizer

Single or dual enthalpy economizer control

Barometric relief damper

Constant volume power exhaust

Modulating power exhaust

Bolt on energy recovery ventilator (ERV)

Air proving switch

Dirty filter switch

CO² sensor

Condensate overflow switch

Low ambient head pressure control

Supply and return air smoke detectors

Smart Equipment™ control communication card

MAP (Mobile Access Portal) Gateway for use with Smart Equipment™ control

Verasys

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV282

Johnson Controls Ducted Systems

Physical dimensions

Figure 1: CV15 and CV18 physical dimensions

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 3

Johnson Controls Ducted Systems

Figure 2: CV20 physical dimensions

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV284

Johnson Controls Ducted Systems

Figure 3: CV25 physical dimensions

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 5

Johnson Controls Ducted Systems

Figure 4: CV28 physical dimensions

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV286

Johnson Controls Ducted Systems

Rain hood dimensions

Figure 5: Rain hood dimensions

Table 1: Rain hood componentsItem DescriptionA Economizer, manual damper, and motorized damper rain hoodB Power exhaust rain hood

Utilities entryTable 2: Utilities entryEntry description Opening size diameter (in.)

Left Field drilled11 to maximum of 7/8 in.Control wiring

Bottom Field drilled1 to maximum of 7/8 in.Left Field drilled1 to maximum of 3 in.

Power wiringBottom Field drilled1 to maximum of 3 in.

Left2, 32, 3 2-in. hole with ¾-in. grommetGas piping

Bottom2 1-1/4 in. hole

Front44 1-1/2-in. holeCondensate drain

Bottom3, 4 2-in. hole with 1-1/4-in. grommet

1 Factory provided dimples show the hole location to facilitate the drilling of entry holes.2 3/4 in. NPT gas piping is required.3 You must insert the piping through the factory-installed grommet for a watertight seal.4 1 in. NPT female connection piping is required.

Note: You must field seal all entry holes to preventrain water entry into the building.

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 7

Johnson Controls Ducted Systems

Accessory weightsTable 3: Unit accessory weights

Unit sizeUnit accessory

15 to 17.5 ton 20 ton 25 ton 27.5 tonEconomizer 145 145 165 165Motorized damper 65 65 75 75Power exhaust 75 75 75 75Barometric damper 50 50 50 50Electric heat (75 kW) 75 75 75 75Gas heat (largest) 155 155 155 155Hail guards 75 80 100 125Wood skid and shippingbrackets 60 70 70 80

Roof curb 215 230 230 250

Table 4: Supply fan VFD weightsSupply fan motor 208/230V 460V 575V

2.9 HP 10 10 103.7 HP 10 10 105.3 HP 10 10 107.5 HP 15 15 1510 HP 20 15 1512 HP 20 15 15

Note: Add 5 lbs. to the supply fan VFD weights ifthere is a bypass.

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV288

Johnson Controls Ducted Systems

Roof curbsThe following figures show the roof curbs for the units. All dimensions are in inches.

Return air

Supply air

Figure 6: 1RC0443 and 1RC0446 roof curb dimensions

Table 5: 1RC0443 and 1RC0446 dimensions

Roof curb X measurement (in.)1RC0443 141RC0446 24

The following units are compatible with 1RC0443 and 1RC0446 roof curbs.• CV15 • CV18

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 9

Johnson Controls Ducted Systems

Figure 7: 1RC0444 and 1RC0447 roof curb dimensions

Table 6: 1RC0444 and 1RC0447 dimensions

Roof curb X measurement (in.)1RC0444 141RC0447 24

The following units are compatible with 1RC0444 and 1RC0447 roof curbs.• CV20• CV25

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV2810

Johnson Controls Ducted Systems

Figure 8: 1RC0445 and 1RC0448 roof curb dimensions

Table 7: 1RC0445 and 1RC0448 dimensions

Roof curb X measurement (in.)1RC0445 141RC0448 24

The following unit is compatible with 1RC0445 and 1RC0448 roof curbs.• CV28

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 11

Johnson Controls Ducted Systems

Figure 9: Roof curb cutaway

Table 8: Roof curb cutaway componentsItem Description Item DescriptionA Wood nailer D Roof felt (field supplied)B Curb frame E Rigid insulation (field supplied)C Counter flashing (field supplied) F Cant strip (field supplied)

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV2812

Johnson Controls Ducted Systems

Economizer options

Figure 10: Economizer options

Table 9: Economizer componentsItem DescriptionA Fresh air hoodB Power exhaust hoodC Power exhaust damperD Power exhaustE Low leak economizer

Typical installationThe following figures show the typical installations for the unit.Figure 11: Roof jack installation Figure 12: Roof curb installation

Submittal Data Sheet: TempMaster® Omni™ Choice CV15 to CV28 13

Johnson Controls Ducted Systems

Subject to change without notice. Printed in U.S.A. Copyright © 2019 by Johnson Controls. All rights reserved.

Johnson Controls Ducted Systems

www.tempmasterhvac.com