Dekker VMX0036MA1-00-BS Laboratory Vacuum System Equipment
Submittal Information
4330 Redwood Highway, Suite 100
San Rafael, CA 94903
Tel 415 507-9373 Fax 415 507-9376
• AES-Dekker Laboratory Vacuum System Model AES-VMX0036MA1-00-BS o (1) Dekker Titan single stage 3HP liquid ring vacuum pump skids. o Capacity vacuum pump 11.7 SCFM @ 20” HGVAC. o System Components Include:
(1) TEFC Electric motors, 230/460 Volt, 3 Phase, Premium Efficiency. (1) Flexible Couplings (1) Fabricated Steel Baseplates (1) Patented DX5 Discharge Separator-Reservoirs with 5 Stage Air/Oil Separation, Including Coalescing Filter. (1) Seal Fluid Isolation Valves (1) Y-Strainers (1) Separator Drain Valves (1) Separator Sight Level Gauges (1) Temperature RTD for Discharge Temperature Indication and High Temperature Protection. (1) High/Low Oil Level Switches (1) Air-Cooled, Heat Exchanger Packages with Main Motor Driven Fan and Fan Guard. (1) Inlet Check Valves Inlet Manifold Including:
• (1) Inlet Isolation Valves
• (1) Inlet Flex Connectors Discharge Manifold Including:
• (1) Individual Pump Drip Legs
• (1) Discharge Check Valves
• (1) Discharge Flex Connectors (1) Sets of Hydraulic Hose Seal Fluid Line. (1) Inlet Filters (1) Inlet Filter Silencers (1) Vacuum Relief Valves
o Vacuum Receiver Horizontal 60 Gallon Vacuum Receiver. Receiver Sight Level Gauge Receiver Drain Valve Receiver Vacuum Gauge
o (1) Dekker ControlDEK Control Panel 460V, 3-Phase, 60Hz, NEMA 12, CUL Listed Monitors, Measures, and Displays Performance Identifies Maintenance and Fault Conditions, Prevents Downtime, and Preserves System Quality. Custom PLC with 4.3” Color Touchscreen LCD and Integral Hour Meter. Across the Line Magnetic Vacuum Pump Starter with 3-Phase Overload Protection. Vacuum On/Off Capability with Adjustable Set Points. Vacuum Transducer for Vacuum Level Indication. Pressure Transducer for Back Pressure Indication. 24V Power Supply
DATE:
SYSTEM APPROVALAPPROVED BY:
63.67
26.0030.00
13.19
A
13.632.00
35.94 D
9.63
11
5
16
17
12
18
1
2
3
6
7
19
20
61.73
29.31
43.63 A
10.50 A
26.32 B
17.17 B
24.81 CALLOW 6" CLEARANCE FORFILTER ELEMENT
REMOVAL AND MAINTENANCE
12" CLEARANCEREQUIRED FORPROPER HEATEXCHANGER OPERATION
44.91
B
1.13 18.7521.00
25.69
C
4.17 C
3.24 D1.65 D
10
13
4
15
9/16" X 1"MOUNTING SLOT(4) PLACES
ALLOW 14" CLEARANCE FOR DOOR SWING
MINIMUM WORK DEPTH IS 48"MINIMUM WORK WIDTH IS 30"
8
9
14
NOTES:1) LOCATE VACUUM PUMP ON FLAT LEVEL SURFACE.2) PLUG ALL UNUSED PORTS WITH NPT PLUG.3) OIL CAPACITY: 1.6 GALLONS P/N: 5220-3300-0004) REFERENCE WI-EN-039 FOR ALL HARDWARE TORQUE SPECIFICATIONS.
REVISIONSREV. DESCRIPTION DATE DWG ERP APP
078624ITEM NO. QTY. DESCRIPTION PART NUMBER
1 1 FILTER INLET 1.0" 35 CFM POLYESTER 2920-0100-001-R2 1 FLEX CONN 1.0" MNPT X 8"LG 304SS/CS 3300-0100-0013 1 CTRL PANEL CONTROLDEK 3HP N12 460V 2273-0030-4604 1 FLEX CONN 1.0" MNPT X 8"LG 304SS/CS 3300-0100-0015 1 VLV BALL .5"FNPT FP 2-PC BRZ/TF 7302-0050-000-R6 1 TUBING .38"OD NYLON 6/6 TRANSLUCENT 7200-0038-0007 1 RECEIVER TNK HORZ 60 GAL CS ASME 6000-0060-1008 1 STRAINER Y .5" FNPT CI/304 6770-0050-0009 1 VLV BALL .5"FNPT FP 2-PC BRZ/TF 7302-0050-00010 2 SWITCH LEVEL 1" MNPT N7 BRS/SST 6910-0100-00011 1 VLV BALL 1" FP 2-PC THD BRZ/TF 7302-0100-00012 1 VLV CK HNG 1.00" THD CS/AL/BUNA 7316-0100-00013 1 VLV PETCOCK .25" BRASS 7329-0025-00014 1 VALVE VAC RELIEF .38" ADJ 15 SCFM 7342-0038-00015 1 HT EX 8.0"X 7.5"X2.45" PASS AIR/LIQ 4005-0807-00016 1 VLV BALL .38" SP 2-PC THD BRZ/TF 7304-0038-00017 1 GAUGE LVL .5" MNPT 6" LG AL/BRS/VITX 3615-0050-00018 1 VLV CK HNG 1.00" THD CS/AL/BUNA 7316-0100-00019 1 TEMPERATURE PROBE RTD 1/4"ODx4 1/8" 7005-0025-00120 1 PUMP LR 1 STG W/MTR 35 CFM CI/SS/V 230/460V DV0035DB-MA3-DBL21 1 CROSS 1" FNPT 150# MIRT 3005-0100-025
SYSTEM NOZZLE SCHEDULEIDENTIFIER CONNECTION SIZE
A VAPOR INLET 1" FNPTB VAPOR DISCHARGE 1" MNPTC SEPARATOR DRAIN 3/8" FNPTD RECEIVER TANK DRAIN 1/2" FNPT
MODEL NO.
PART NO.
DRAWING BY:
WEIGHT:2018328-D
408.35 LB
DRAWING TYPESUBMITTAL
DWG NO.
VMX0036MA1-00-BS
078624
SCALE:1:8
DATE:
VMX0036MA1-00-BS 460V TEFCDESCRIPTION
SPECIFIED IN DRAWINGUNLESS OTHERWISE
± .50°FRACTIONAL
ANGULAR
DECIMAL ± .50"
TOLERANCES
± 1/2"DESIGN BY:
CHECKED BY:
PROJECT ENG:
APPROVED BY:
DATE:
DATE:
DATE:
5/1/2018
5/1/2018
5/3/2018
5/11/2018
WH
RHC
RHC
AWH
AWHSHEET NO.1 OF 1
SERIAL NO.
A
1 2 3 54 6 7 8 9 10
B
C
D
E
F
G
H
I
J
31 7 852 4 6
D
H
C
I
B
F
E
G
A
THIS PRINT IS PROPERTY OF DEKKER VACUUM TECHNOLOGIES, INC. AND MAY NOT BE GIVEN TO ANY OTHER
CONCERN WITHOUT THE CONSENT OF DEKKER VACUUM TECHNOLOGIES, INC.
1
1
A
B
C
D
E
F
G
H
I
J
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
2 3 4 5 6 LBS
SPECIFIED IN DRAWING
UNLESS OTHERWISE
± 0° 30' 00"
FRACTIONAL
ANGULAR
DECIMAL ± .0625"
TOLERANCES
± 1/16"
- BTHIS PRINT IS PROPERTY OF DEKKER
MAY NOT BE GIVEN TO ANY OTHERCONCERN WITHOUT THE CONSENT OF
DEKKER VACUUM TECHNOLOGIES, INC.
VACUUM TECHNOLOGIES, INC. AND
APPROVED BY:
PROJECT ENG:
MODEL NUMBER:
PART NUMBER:
DRAWING BY:
DESIGN BY:
CHECKED BY:
DATE:
DATE:
DATE:
DATE:
SERIAL NUMBER: WEIGHT:
DRAWING TYPE:
DESCRIPTION:
SCALE:
DWG NUMBER:
SHEET NUMBER:
REVISIONS
REV DESCRIPTION DATE DWG ERP APP
OF
VMX0036
2273-0030-460
JMD 11/10/17
JMD 11/10/17
NTH 11/13/17
RHC 11/21/17
-AWH
INDUSTRIAL CONTROL PANEL SIMPLEX
3HP CONTROLDEK 460V NEMA12
2017943SUBMITTAL
30 NONE 1 4
A ADD CANBUS POWER, REVISE LAYOUT 5/2/18 DLA DLA NTH
CABINET LAYOUT
INSTALL SOFTWARE: CONTROLDEK
D-1
TS-1 TS-2CANBUS
FB-1
PS-1
FB-2,3 PS-2
-Vin +Vin
+ -
DC
ON
O/P
ADJ
OL-1
M-1
GND
GND
+V
3
3
+V1 15 16112 12 122 1
+V SH-V L H
H
+V -V LSH H
2 12 1 152 12 1 161
5 9 108 12 1311
1
76
LSH-V
LSH+V
HG
G
G
G
-V
+V
6 14-- 84 95 107 11 12 13
4-- 14
G
G
G
G
RESET
AUTOHAND/
START ESCRESETSTOP
controlDEK dekkervacuum.com
PLC-1
ITEM QTY LABEL DESCRIPTION PART NUMBER
1 1 ENCL ENCLOSURE N4/12 16"X14"X8" 2607-1614-080
2 1 M-1 CONTACTOR AC IEC 7A 3PH C-H 24VDC 2598-0007-002
3 1 OL-1 OVERLOAD RLY FRAME B 2.4-4.0A C-H 2625-0004-003
4 1 PS-1 POWER SUPPLY 24VDC 5A 380-480VAC 2621-0024-010
5 1 PS-2 24V DC/DC CONVERTER 1A 24VDC 2621-0024-026
6 1 FB-1 FUSE HLDR FINGSF CL. CC 2POLE IND 2611-0002-002
7 2 FU-1,2 FUSE 4 AMP TIME DELAY CLASS CC 2610-0004-001
8 2 FB-2,3 ELEC.TERM BLOCK 2 LEVEL FUSED INDICATING 2604-2412-008
9 1 FB-2,3 END SECTION FOR DOUBLE LEVEL FUSED TB 2606-2412-012
10 1 FU-3 FUSE 4 AMP 5x20mm GLASS FUSE TIME DELAY 2610-0004-004
11 1 FU-4 FUSE, 1A, 250VAC, 5X20mm, GLASS SLO-BLOW 2610-0001-020
12 1 PLC-1 DEKKER CUSTOM V430 12IN/10OUT CANBUS 2540-2400-017
13 1 PLC-1 MICROSD MEMORY CARD 8GB 2555-0008-000
14 1 TR-1 TRANS PRESS 0-15PSIA 4-20MA 7120-0025-020
15 1 TR-2 TRANS PRESS 0-15PSIG 0-10VDC 7120-0025-008
16 2 TR-1,2 BUSHING BULK.75"UNC X .25"FNPT BRS 3002-7525-004
17 1 RESET PUSH BUTTON OVERLOAD RELAY RESET 2630-0010-000
18 1 D-1 ELEC.TERM BLK 2-LEVEL 6.2MM W/DIODE 2604-2412-003
19 17 TS ELEC.TERM BLOCK DOUBLE LEVEL 6.2MM 2604-2412-004
20 2 TS ELEC.TERMINAL BLOCK GND 6.2 2-TIER 2604-2412-005
21 2 TS ELEC.TERMINAL BLOCK END COVER 2606-2412-000
22 6 TS ELEC.TERMINAL BLOCK END SECTION DIN 2606-2412-002
23 1.5 DIN RAIL ELEC.TERM. BLK. DIN RAIL 7.5 X 35MM 2602-2410-000
24 0.56 WIRE DUCT WIRING DUCT W/ COVER 1.00"X2.25" WH 9702-0100-225
25 1.67 WIRE DUCT WIRING DUCT W/ COVER 1.50"X2.25" WH 9702-0150-225
26 2 GND LUG, GROUNDING, 14-2 AWG 2552-1402-000
BILL OF MATERIALS
DATE:
SYSTEM APPROVAL
APPROVED BY:
POWER DISTRIBUTION
1
1
A
B
C
D
E
F
G
H
I
J
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
2 3 4 5 6 LBS
SPECIFIED IN DRAWINGUNLESS OTHERWISE
± 0° 30' 00"
FRACTIONAL
ANGULAR
DECIMAL ± .0625"
TOLERANCES
± 1/16"
- BTHIS PRINT IS PROPERTY OF DEKKER
MAY NOT BE GIVEN TO ANY OTHERCONCERN WITHOUT THE CONSENT OF
DEKKER VACUUM TECHNOLOGIES, INC.
VACUUM TECHNOLOGIES, INC. AND
APPROVED BY:
PROJECT ENG:
MODEL NUMBER:
PART NUMBER:
DRAWING BY:
DESIGN BY:
CHECKED BY:
DATE:
DATE:
DATE:
DATE:
SERIAL NUMBER: WEIGHT:
DRAWING TYPE:
DESCRIPTION:
SCALE:
DWG NUMBER:
SHEET NUMBER:
REVISIONSREV DESCRIPTION DATE DWG ERP APP
OF
VMX0036
2273-0030-460
JMD 11/10/17
JMD 11/10/17
NTH 11/13/17
RHC 11/21/17
-AWH
INDUSTRIAL CONTROL PANEL SIMPLEX
3HP CONTROLDEK 460V NEMA12
2017943SUBMITTAL
30 NONE 2 4
L1
60 HZ
3 PHASE
480 V
L3
L2
G
MINIMUM 14 AWG
14 AWG
M-1 OL-1
1T3
1T2
1T1
14 AWG
MTR-13 HP | 3.6 FLA | 1.25 SFVACUUM PUMP MOTOR
L1
L3
G G
+ 24VDC
2
1
-
+
POWER
SUPPLY
L1
PS-1
L2
+24VFU-1
FU-2
FU-3
24VDC COM
+CANBUS
-V
+V
-
+ FU-4
-CANBUS
1
2
+V
-V
V1
V2
L1A
L2A
L1
L2
G
4 AMP CLASS CC
FB-1 FB-2
4 AMP
1 AMP
FB-3
L2
LUG LUG
PS-2
-
+
G
+24V
DC/DC
CONVERTER
INPUT OUTPUT
3
D-1
A ADD CANBUS POWER, REVISE LAYOUT 5/2/18 DLA DLA NTH
UPSTREAM PROTECTION: FUSIBLE DISCONNECT OR CIRCUIT BREAKER MUST BE PROVIDED BY INSTALLER AS PER STATE AND LOCAL CODES.MAXIMUM CLASS J FUSE: 15 AMP
PANEL VOLTAGE: 480V / 3 PHASE / 60HZ
SCCR: 5kA RMS SYMMETRICAL AT 600V*
LARGEST MOTOR: 3 HP
PANEL FULL LOAD AMPS: 4.0 AMPS
*SCCR: 100kA RMS SYMMETRICAL AT 600VWHEN PROTECTED WITH 100kAIC OR GREATER FUSIBLE DISCONNECT OR CIRCUIT BREAKER.
MAXIMUM INV. TIME BREAKER: 15 AMP
TORQUE TERMINAL BLOCKS TO 5-7 L1BINUL/cUL LISTED CONTROL PANEL
REPLACE WITH LIKE FUSES ONLYUSE COPPER WIRE ONLY
INDICATES TERMINAL BLOCKINDICATES RELAY TERMINAL POINT
DENOTES EXTERNAL WIRING
3.
6.
4.
5.
NOTES:
1.2.
7.
MAXIMUM CLASS CC FUSE: 15 AMP
CONTROL - PLC
V430-J-RA22
PLC-1
1
2
3
6
7
8
9
10
11
12
13
14
15
M-1
1413 OL-1
9695
RTD-1
SEAL FLUID TEMPERATURE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
M-1A1 A2
24VDC + 24VDC COM
+V
0V
GND
I9
I8
I7
AN2
AN3
I4
I3
I2
I1
I0
0V
A0
A1
O4
O5
O6
O7
1
2
1
1
1
1
4
5
6
7
8
G
24VDC COM
24VDC COM
16
VACUUM PUMP MOTOR RUNNING SIGNAL
OPTIONAL HIGH LEVEL SWITCH
OPTIONAL HORN SILENCE PUSHBUTTON
VACUUM PUMP MOTOR OVERLOAD SIGNAL
VACUUM PUMP CONTACTOR (ENERGIZE = RUN)
OPTIONAL LOW LEVEL SWITCH
2
11
1 7
8
9
16
11
2
5 I10
4 I11
G
RTD
INPU
T
SYSTEM VACUUM0-15 PSIA|4-20 mA
TR-19
1
G
24VDC +
10BACKPRESSURE
0-15 PSIG|0-10 VDC
TR-210
1
G
24VDC +
2 24VDC COM
1111
1212
1313
1414
1515
1OPTIONAL REMOTE STOP
1OPTIONAL REMOTE START
LLS-1
HLS-1
REMOTE START
REMOTE STOP
JUMPER
JUMPER
JUMPER
PB-1
REMOVE JUMPER IF INSTALLED
REMOVE JUMPER IF INSTALLED
CLOSE CONTACT TO SILENCE
OPEN CONTACT TO STOP
CLOSE CONTACT TO START
REMOVE JUMPER IF INSTALLEDA
NA
LOG
INPU
TS
O0
O1
O2
O3
AN
ALO
G O
UTPU
T S
WHT
RED
RED
BLK
RED
WHT
RED
BLK
WHT
RED
BLK
4
5
6
A
B
1
JUMPER SETTINGS
23456789101112
CONTROLLER
1314
1
1
A
B
C
D
E
F
G
H
I
J
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
2 3 4 5 6 LBS
SPECIFIED IN DRAWINGUNLESS OTHERWISE
± 0° 30' 00"
FRACTIONAL
ANGULAR
DECIMAL ± .0625"
TOLERANCES
± 1/16"
- BTHIS PRINT IS PROPERTY OF DEKKER
MAY NOT BE GIVEN TO ANY OTHERCONCERN WITHOUT THE CONSENT OF
DEKKER VACUUM TECHNOLOGIES, INC.
VACUUM TECHNOLOGIES, INC. AND
APPROVED BY:
PROJECT ENG:
MODEL NUMBER:
PART NUMBER:
DRAWING BY:
DESIGN BY:
CHECKED BY:
DATE:
DATE:
DATE:
DATE:
SERIAL NUMBER: WEIGHT:
DRAWING TYPE:
DESCRIPTION:
SCALE:
DWG NUMBER:
SHEET NUMBER:
REVISIONSREV DESCRIPTION DATE DWG ERP APP
OF
VMX0036
2273-0030-460
JMD 11/10/17
JMD 11/10/17
NTH 11/13/17
RHC 11/21/17
-AWH
INDUSTRIAL CONTROL PANEL SIMPLEX
3HP CONTROLDEK 460V NEMA12
2017943SUBMITTAL
30 NONE 3 4
A ADD CANBUS POWER, REVISE LAYOUT 5/2/18 DLA DLA NTH
PLC COMMUNICATIONS
1 485 A+
6 485 B-
RS-485
PORT 2
V430
CUSTOMER MODBUS
OPTIONAL
FOR MULTIPLEXING
CANBUS
IF EQUIPPED
PLC-1
(NOT IN TRUE ORDER)CANBUS PORT
121Ω1/4W, 1%
121 OHM
RESISTOR
OPTIONAL CUSTOMER MODBUS CONNECTION
150Ω 1/2W RESISTOR
B-
A+
0V
SH15
0Ω
+V
-V
L
H
SH
+V
-V
L
H
SH
+V
-V
L
H
SH
121Ω
121Ω
NOTE: REMOVE TERMINATING RESISTOR FROMTHE CENTER PANEL OF CANBUS NETWORK
BLU
WHT
BLU
WHT
OR EQUIVALENTBELDEN 3084A CABLE
BLK
RED
BLU
WHT
BLK
RED
BLU
WHT
OR EQUIVALENTBELDEN 3084A CABLE
BLK
RED
BLK
RED
RED
BLK
WHT
RED
BLK
WHT WHT WHT WHT WHT
B-
A+
0V
SH
B-
A+
0V
SH
1/2W RESISTORRED
BLK
RED
BLK
RED
BLK
RED
BLK
NOTE: TERMINATE SHIELD OFONLY FIRST PANEL TO GND
2B
2A
0V
SH
NOTE: TERMINATE SHIELD OFONLY MODBUS MASTER TO GND
NOTE: A SUCCESSFUL MODBUS LINK CAN OFTEN BE MADE WITH SUITABLE TWISTED, SHIELDEDPAIR CABLE. THE TRIAD CABLE MAY BE NEEDED IF A 0V REFERENCE CONNECTION IS REQUIRED.
150 OHM
(BY INSTALLER)
MASTERMODBUS RTU
END USER
SLAVEMODBUS RTU
END USER
SLAVEMODBUS RTU
END USER
SLAVEMODBUS RTU
VACUUM SYSTEM
TWISTED, SHIELDED TRIAD TWISTED, SHIELDED TRIAD TWISTED, SHIELDED TRIAD
150 OHM
BY INSTALLER
1/4W, 1%121 OHM
RESISTOR1/4W, 1%121 OHM
RESISTOR
G
G
PANEL 3 (TS-2)PANEL 2 (TS-2)PANEL 1 (TS-2)
ONOFF
1 2 3 4 5 6
SWITCH SETTINGSPORT 2 DIP
1
1
A
B
C
D
E
F
G
H
I
J
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
2 3 4 5 6 LBS
SPECIFIED IN DRAWINGUNLESS OTHERWISE
± 0° 30' 00"
FRACTIONAL
ANGULAR
DECIMAL ± .0625"
TOLERANCES
± 1/16"
- BTHIS PRINT IS PROPERTY OF DEKKER
MAY NOT BE GIVEN TO ANY OTHERCONCERN WITHOUT THE CONSENT OF
DEKKER VACUUM TECHNOLOGIES, INC.
VACUUM TECHNOLOGIES, INC. AND
APPROVED BY:
PROJECT ENG:
MODEL NUMBER:
PART NUMBER:
DRAWING BY:
DESIGN BY:
CHECKED BY:
DATE:
DATE:
DATE:
DATE:
SERIAL NUMBER: WEIGHT:
DRAWING TYPE:
DESCRIPTION:
SCALE:
DWG NUMBER:
SHEET NUMBER:
REVISIONSREV DESCRIPTION DATE DWG ERP APP
OF
VMX0036
2273-0030-460
JMD 11/10/17
JMD 11/10/17
NTH 11/13/17
RHC 11/21/17
-AWH
INDUSTRIAL CONTROL PANEL SIMPLEX
3HP CONTROLDEK 460V NEMA12
2017943SUBMITTAL
30 NONE 4 4
1 485 A+
6 485 B-
TS-4
2
2B
2A
SH
2
24VDC COM
TS-2
+V
-V
L
H
SH
OR EQUIVALENTBELDEN 3084A CABLE
+V
+CANBUS
-V
- CANBUS
+V
-V
L
H
SH
PANEL TO PANEL CANBUS CONNECTION (FOR MULTIPLEX OPERATION)
A ADD CANBUS POWER, REVISE LAYOUT 5/2/18 DLA DLA NTH
935 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 46360-5672TOLL-FREE: 888-925-5444 TEL.: 219-861-0661 FAX: 219-861-0662
Page number5-106
Please visit our Website atwww.dekkervacuum.com
Su
ctio
n A
ir C
ap
acity
(Dry
)A
CF
MA
bso
rbe
d P
ow
er
(HP
)
Performance characteristicsNominal capacity: 35CFMMotor: 60Hz/3HP/2.2kW 50Hz/2HP/1.5kW Speed(RPM): 60Hz/3500 50Hz/2900 Max.vacuum: 29"Hg/25TorrWeight (including motor): 78Lbs/35kgMax. gas inlet
o otemp: 212 F/100 CMax.noise level(at 3ft):70 dBAPerformance based on dryair, seal-water temperature
o60 F and atmosphericpressure of 29.92"Hg.
Absolute pressure (Torr)
5. SINGLE-STAGE PUMPS
Tolerance 10 %
Materials of construction/Seal codeMat.code 3 4Casing Portplate Impeller Shaft Seal code B*A= standard mechanical seal with Viton elastomerB= standard mechanical seal with Teflon elastomer* = other seal materials available upon request.
2316 SS 316 SS 316 SS 316 SS
NA
1 NA
NA NA NA NA
cast iron cast iron 316 SS
420 SS A*
Why should you consider this vacuumpump for your application?
NA NA
NA NA
DV0035B-MA
US
GP
MS
ervice
Liq
uid
Vacuum (Inch Hg)
1.0
2.0
2
3
4
29.2 29 28.5 28 27.5 27 26 25 24 23 22 20 18 14 10 5 2
40
30
20
10
0
20 25 30 40 50 60 70 80 90 100 200 300 400 500 600 700
0.0
3500 RPM
3500 RPM
2900 RPM
2900 RPM
0
1
Motor-mounted vacuum pumpDV0035B-MA
t Designed for heavy duty applications.
316 stainless steel impeller is standard.
Features economical UL/CSA EPACT-compliant motor-mounted design.
Manufactured to ISO 9001 standards.
Low operating noise level.
Features single face mechanicalseal as standard.
Virtually no maintenance is required.
Compact design results in smallfootprint design.
Capable of handling saturatedgas mixtures.
Capable of handling small amounts of liquids.
Only one moving part.
Can operate using various seal- fluids.
t
t
t
t
t
t
t
t
t
t
t
Dimensions (inches) not binding. Subject to change without notice.
DV0035B-MA
Introducing the serieshigh efficiency, single-stage liquid ring vacuum pump.
TITAN
Reference1010/7/smb
9.08
3.944.92
6.858.15
3.74
5.94
3/4" FNPTCONDUITCONNECTION
3.54SHAFT
.49 5.51
.39 THRUMOUNTING HOLES
(6) PLACES
CL
.71
2.40
9.09
6.50
.20
.24
1/4" FNPTSEAL FLUIDPORT
1/4" FNPTPUMP DRAINPORT
1" FNPT INLET 1" FNP DISCHARGE
19.71
0.95
2.96
Product Information Packet
DEKKER VACUUM TECH INC
50150030015
2.2KW,3450RPM,3PH,60HZ,D90DYZ,3532M,TEFC
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
Page 2 of 5
Product Information Packet: 35Z719Q060G1 - 2.2KW,3450RPM,3PH,60HZ,D90DYZ,3532M,TEFC
Part Detail
Revision: D Status: PRD/A Change #: Proprietary: Yes
Type: AC Elec. Spec: 35WGQ060 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 35Z719 Layout: 35LYZ719 Poles: 02 Created Date: 12-02-2015
Base: RG Eff. Date: 03-19-2018 Leads: 9#18
Specs
Enclosure: TEFC
Frame: D90DYZ
Frame Material: Steel
Output @ Frequency: 2.200 KW @ 60 HZ
Synchronous Speed @ Frequency: 3600 RPM @ 60 HZ
Voltage @ Frequency: 230.0 V @ 60 HZ
460.0 V @ 60 HZ
XP Class and Group: None
XP Division: Not Applicable
Agency Approvals: CSA EEV
CSA
UR
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Rigid
Bearing Grease Type: Polyrex EM (-20F +300F)
Blower: None
Current @ Voltage: 3.600 A @ 460.0 V
Insulation Class: F
Inverter Code: Inverter Ready
KVA Code: L
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 18 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 3532M
Mounting Arrangement: B35
Power Factor: 92
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: D-Flange
Pulley Shaft Indicator: Tapped & Key
Rodent Screen: None
RoHS Status: ROHS COMPLIANT
Shaft Extension Location: Double Shaft
Page 3 of 5
Product Information Packet: 35Z719Q060G1 - 2.2KW,3450RPM,3PH,60HZ,D90DYZ,3532M,TEFC
7.200 A @ 230.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Frame Prefix: D
Front Face Code: Standard
Front Shaft Indicator: Special Combos Not Listed
Heater Indicator: No Heater
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: IEC
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: None
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
Page 4 of 5
Product Information Packet: 35Z719Q060G1 - 2.2KW,3450RPM,3PH,60HZ,D90DYZ,3532M,TEFC
Nameplate NP3386L
CAT.NO.
SPEC. 35Z719Q060G1
IEC FRAME D90DYZ KW 2.2
VOLTS 230/460
AMP 7.2/3.6
RPM 3450 ENCL TEFC
HZ 60 PH 3 CL F
SER.F. 1.25 DES B CODE L
NEMA-NOM-EFF 86.5 I.P. 54
RATING 40C AMB-CONT
CC 010A USABLE AT 208V
DE 6206 ODE 6203
SER. #
SFA 9/4.5
Page 5 of 5
Product Information Packet: 35Z719Q060G1 - 2.2KW,3450RPM,3PH,60HZ,D90DYZ,3532M,TEFC
SERIES L6 | W.E. ANDERSON FLOTECT® Liquid Level Switch
dwyer-inst.com
DWYER INSTRUMENTS, INC.
DS-L6 | 4/16
®
T: 219-879-8000 | F: 219-872-9057 | [email protected]
FEATURES/BENEFITS
• Compact design is built for years of trouble-free service• Simple and dependable operation with no mechanical linkage• Float lever pivoted within the body moves when the process liquid displaces thefloatandmagnetontheoppositeendofthefloatlevercontrolsasecondmagneton the switch actuating lever located in the switch housing
• Leak proof lower body machined from bar stock• Sidewallordirectteemountingoptionsavailabletoactasanexternalfloat
chamber• Weatherproof and explosion-proof body for demanding outdoor applications• Electrical assembly can be easily replaced without removing the unit from the
installation so that the process does not have to be shut down• Sensitivetolevelchangesoflessthan1/2˝(12mm)
APPLICATIONS
• Direct pump control for maintaining level• Automatic tank dump operations• Level control• Valve control• Level alarm in sumps, scrubber systems, hydro-pneumatic tanks, boilers, and water/
wastewater treatment processes
DESCRIPTION
The SERIES L6 Flotect® Float Switches is a rugged and reliable float switch which operates automatically to indicate tank level. It is offered with a 303 SS or brass body with spherical or cylindrical float options.
Model L6 with External Float Chamber
Model L6 with Spherical Float
Model L6 with Cylindrical Float
SPECIFICATIONSService Liquids compatible with wetted materials.
Wetted Materials Float: Solid polypropylene or 304 SS; Lower Body: Brass or 303 SS; Magnet: Ceramic; External Float Chamber (Tee): Matches lower body choice of brass or 303 SS; Other: Lever Arm, Spring, Pin, etc.: 301 SS.
Temperature Limit-4 to 220°F (-20 to 105°C) Standard, MT high temperature option 400°F (205°C)(MT not UL, CSA, ATEX, IECEx and KC). ATEX compliant AT, IECEx IEC and KC option ambient temperature -4 to 167°F (-20 to 75°C) process temperature: -4 to 220°F (-20 to 105°C).
Pressure Limits See model chart.
Enclosure Rating
Weatherproof and Explosion-proof. Listed with UL and CSA for Class I, Groups A, B, C and D; Class II, Groups E, F, and G. (Group A on stainless steel body models only). ATEX 0344 II 2 G Ex d IIC T6 Gb Process Temp≤75°C. EC-Type Certificate No.: KEMA 04ATEX2128. ATEX Standards: EN 60079-0: 2009; EN60079-1: 2007. IECEx Certified: For Ex d IIC T6 Gb Process Temp≤ 75°C. IECEx Certificate of Conformity: IECEx DEK II.0039. IECEx Standards: IEC 60079-00: 2007; IEC 60079-1: 2007. Korean Certified (KC) for Ex d IIC T6 Gb Process Temp≤75°C. KTL Certificate Number: 2012-2454-75.
Switch Type SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating UL models: 5 A @ 125/250 VAC (V~). CSA, ATEX and IECEx models: 5 A @ 125/250 VAC (V~); 5 A res., 3 A ind. @ 30 VDC (V ). MV option: .1 A @ 125 VAC (V~). MT option: 5 A @125/250 VAC (V~). [MT option not UL, CSA, ATEX or IECEx].
Electrical Connections UL models: 18 AWG, 18˝ (460 mm) long. ATEX/CSA/IECEx models: terminal block.Upper Body Brass or 303 SS.
Conduit Connection 3/4˝ male NPT standard, 3/4˝ female NPT or M25 with BSPT option on junction box models.
Process Connection 1˝ male NPT or 1˝ male BSPT on models without external float chamber, 1˝ female NPT or 1˝ female BSPT on models with external float chamber.
Mounting Orientation Horizontal with index arrow pointing down.SpecificGravity See chart.
Weight Approximately 1 lb (.5 kg) without external float chamber, 1.75 lb (.8 kg) with external float chamber.Agency Approvals ATEX, CE, CSA, IECEx, KTL, UL.
®
DIMENSIONS
1 FEMALENPT/BSPT TYP 2 PLACES
3-5/64[78.18]
1-9/64[28.97]
2 [50.80]HEX
8-9/16 [217.49]
3/4 MALE NPTCONDUIT
CONNECTION
Ø1-1/16[26.99]
Ø1 [25.40]
1-3/4[44.45]
1 MALENPT/BSPT
3/4[19.05]
6[152.40]
Ø1-1/16[26.99]
3/4 MALE NPTCONDUIT
CONNECTIONØ1 [25.40] x 2 [50.80]
LONG FLOAT 1 MALENPT/BSPT
2-7/8[73.03] 1-1/16 [26.99]
6-1/2[165.10]
Ø1-1/16[26.99]
3/4 MALE NPTCONDUIT CONNECTION
Model L6 with External Float Chamber Model L6 with Spherical Float Model L6 with Cylindrical Float
HOW TO ORDER
SERIESL6 - FLOTECT® Mini-size flow switches
BODYB-B - BrassS-S - SS
FLOAT MATERIAL-S - SPDT-D - DPDT
L6 EP B-B -S
Use the bold characters from the chart below to construct a product code.
-O
PROCESS CONNECTION-3 - NPT-4 - BSPT process connection and M25 conduit connection on units with junction box
OPTIONS-MV - Gold plated contacts for dry circuits (see electrical rating in specifications)-MT - High temperature rated 400°F (204°C) (see electrical rating in specifications, no listings or approvals, only available on models with stainless steel floats)-CSA - CSA and UL approved construction, includes weatherproof and explosion-proof junction box-AT - ATEX compliant construction includes, weatherproof and explosion-proof, junction box-IEC - IECEx certified construction
FLOAT TYPE AND INSTALLATION-O - Polypropylene, spherical, side wall mount-A - 304 SS, cylindrical, side wall mount-B - Polypropylene, spherical, brass external float chamber-C - 304 SS, spherical, side wall mount-H - 304 SS, spherical, brass external float chamber-L - 304 SS, spherical, 304 SS external float chamber-S - Polypropylene, spherical, 304 SS external float chamber
-3
CONSTRUCTIONEP - Explosion proof
Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Dwyer advises its customers to obtain the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current.
dwyer-inst.com
DWYER INSTRUMENTS, INC.
DS-L6 | 4/16
T: 219-879-8000 | F: 219-872-9057 | [email protected] 800-872-9141
A
B
Dimensional Data: (inches)A(O.D.) B* C
1 1.3 3.5 1.6
11/4 1.7 3.5 2.0
11/2 1.9 4.0 2.3
2 2.4 4.0 2.8
21/2 2.9 5.0 3.3
3 3.5 5.5 3.9
4 4.5 6.0 4.9
5 5.6 7.0 6.1
6 6.6 8.0 7.1
8 8.6 10.0 9.5
10 10.8 12.0 11.5
12 12.8 14.0 13.8
Valve size
C
Consult factory for larger sizes. *All “B” dimensions EEEEE.060”
*All fasteners and spring pins are 316 stainless steel. BUNA-N is standardseal in all valves. Optional seal materials: EPDM, SILICONE, VITON. 316 stain-less steel springs are optional for all models. Consult factory for any otherspecial material requirements.#Max Operating Pressure at 60oF.
1The Cv of our high-performance checkvalves is almost twice that of conventional,metallic-hinge, double door check valves forsizes 2” through 4” and approximately 25%more for sizes 16” through 24”.
Standard Male NPT Models and Materials*Model Body Discs Wing Support M.O.P.#
07-0-0 Aluminum Aluminum Forged 50 PSIASTM B241 ASTM B209 Aluminum6061T6 6061T6 6061
07-1-0 Carbon Steel Aluminum Forged 150 PSIASTM A53GR.B ASTM B209 Aluminumor A106 6061T6 6061
07-1-4 Carbon Steel Stainless Steel Forged 150 PSIASTM A53Gr.B ASTM A240 Stainless Steelor A106 316 316
07-3-3 Brass Brass Forged Brass 150 PSIASTM B43 ASTM B36 ASTM B124Alloy C230 Alloy C260 Alloy C377
07-4-4 Stainless Steel Stainless Steel Forged 150 PSIASTM A 312 ASTM A240 Stainless SteelGr. 316 316 316
U.S. ValveWe make high-performance checkvalves that will double your Cv.1 If youare looking for the lowest possiblepressure loss then our resilient hingeddouble disc valves are what you need.
DurableOur unique, air-foil designed wing sup-port conditions the flow profile, result-ing in a more laminar, less turbulentflow, thus extending the life of the valve.Our valves consistently out-perform allother products on the market today.
Low MaintenanceA protective coating secures ourvalves against normal atmosphericcorrosion and enhances appearance,making priming and paintingunecessary.
ReliableEach of our valves is individually in-spected and tested to ensure perfor-mance. Most manufacturers will checkonly random valves. We test every,single one.
Highest QualityOur designs specify the finest materi-als engineered specifically for each ap-plication. We manufacture all ourvalves with forged wing supports forsuperior strength against linear loads,and all wing pins and fasteners aremade of 316 stainless steel.
Manufactured by U.S. ValveEvery component is manufactured en-tirely by U.S. Valve. We control thequality, we control delivery and wekeep our prices down.
In StockWe stock a vast inventory of valves,so most sizes and materials can shipthe same day.
Parts and Description:
1 Body
2 Disc
3 Disc Backup
4 Wing Support
5 Wing Pin
6 Seal
7 Sealing Washer
8 Wing Support Screw
9 Disc Assembly Screw
10 Wing Assembly Screw
11 Spring (Optional)
1
U.S.Valve LLC168 South Van Brunt StEnglewood NJ 07631tel: (201) 569 4241fax: (201) 569 2278email: [email protected]: www.usvalve.com
4 6 2 3
8
7
11
5
9
Item Description
10
10 100
1,00
0
10,0
00
100,
000
2" 2-1/
2"
3" 4" 5" 6" 12"
10"
8"
.1
1
10
30
100
1,00
0
10,0
00
100,
0000
1,00
0,00
0
2" 2-1/
3" 4" 5" 6" 12"
10"
8"
.01
.1
1.0
2.0
3.0
Pressure Loss Charts:
Pre
ssu
re lo
ss in
P.S
.I.
Water Flow - @ 70oF - GPM
Your U.S.Valve Representative:
Air Flow - @ 60oF - SCFM
Pre
ssu
re lo
ss in
P.S
.I.
U.S.Valve LLC
168 South Van Brunt StEnglewood NJ 07631tel: (201) 569 4241fax: (201) 569 2278email: [email protected]: www.usvalve.com
VMX0036MA1VMX0036MA1Maintenance PartsMaintenance Parts
2924-0055-001Replacement Element
(Not Shown)
Replacement ElementInlet Filter
6855-0100-035Discharge Hose (Kit)
Separator Element (Not Shown)7342-0038-000Vacuum Relief Valve
Inlet Filter1-3k Hours
Discharge Hose (Kit)As needed
Separator Element6300-0312-00010k Hours Vacuum Relief Valve
As needed10k Hours
7316-0100-000Separator Gasket 7316-0100-000Check ValveAs needed
Separator Gasket3545-0038-000As Needed As neededAs Needed
4005-0807-0004700-2000-010Seal Change Kit
4005-0807-000Heat Exchanger
Seal Change Kit30k Hours
Heat ExchangerAs needed
30k Hours
(Not Shown)(Not Shown)4730-2008-021Scavenge Line (Kit)Scavenge Line (Kit)As needed2710-2011-580
Fan Shroud
4730-2008-025
As neededFan Shroud5058-0030-000 4730-2008-025
Seal Fluid Hose (Kit)
5058-0030-000FanAs needed
5220-0050-000 Seal Fluid Hose (Kit)4730-2008-038W/ Temp Control Valve
As needed5220-0050-000Standard Oil (1.75 Gal)Yearly or 10k Hours W/ Temp Control Valve
As neededYearly or 10k Hours
As needed
Please verify Serial Number prior to order.Filters and Accessories not included on all standard systems.
Installation
Operation
&
Maintenance
Manual
Oil-Sealed Liquid Ring Vacuum Pump Systems
Part No. 9983-0000-S01 Rev. A / January 2018
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 2
OIL-SEALED LIQUID RING VACUUM PUMP SYSTEMS
TABLE OF CONTENTS
CUSTOMER SERVICE 5
CONTACT INFORMATION 5 ORDER INFORMATION 5
INTRODUCTION 6
SAFETY 6
THEORY OF OPERATION 7
STORAGE 8
INITIAL FREIGHT RECEIPT AND INSPECTION 8
INSTALLATION 8
OVERVIEW 8 UNPACKING 8 LIFTING 8 LOCATION 8 MOUNTING 9 VENTILATION 9 ELECTRICAL PREPARATION 10 PIPE CONNECTION AND SIZING 11 INLET PIPING 11 DISCHARGE PIPING 12 COOLING WATER PIPING 12
START-UP PROCEDURES 13
SHUT DOWN PROCEDURES 18
MAINTENANCE 18
PUMP BEARING LUBRICATION 18 MOTOR BEARING LUBRICATION (WHERE REQUIRED) 18 INLET FILTER (IF INSTALLED) 18 SEAL FLUID 18 OIL CHANGE PROCEDURE 18 VMX0203-VMX0553 19 VMX0063-VMX0153 20 VMX0036 20 STANDARD SYSTEM CAPACITIES 21
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 3
PRIMING THE PUMP 21 COMPLIMENTARY OIL ANALYSIS 21 OIL SOLENOID VALVE 22 SEAL FLUID STRAINER 22 SEPARATOR ELEMENT 22 SEPARATOR ELEMENT OIL RETURN LINE 22 SHAFT SEALS 22
MAINTENANCE SCHEDULE 23
FIRST 8 HOURS OF OPERATION 23 DAILY 23 500 HOURS OF OPERATION 23 1000 HOURS OF OPERATION 23 10,000 HOURS OF OPERATION 23 30,000 HOURS OF OPERATION 23 DEVARNISHING 24
ACCESSORIES AND PROTECTIVE DEVICES (IF INCLUDED) 24
ACCESSORIES 24 PROTECTIVE DEVICES 24
TROUBLESHOOTING 25
START-STOP PROBLEMS 25 UNIT WILL NOT START 25 UNIT SHUTS DOWN WHILE RUNNING 25 VACUUM PROBLEMS 26 UNIT OPERATES, BUT DOES NOT ACHIEVE DESIRED VACUUM LEVEL 26 OVERHEATING PROBLEMS 26 UNIT OVERHEATS OR OPERATES ABOVE 200°F 26 UNIT OVERHEAT ON START-UP IN LOW AMBIENT TEMPERATURES 26 NOISE AND VIBRATION PROBLEMS 26 THE SYSTEM IS MAKING AN ABNORMAL NOISE OR SOUND 26 SYSTEM IS VIBRATING EXCESSIVELY 27 OIL PROBLEMS 27 SYSTEM USES EXCESSIVE OIL OR PRODUCES AN OIL-MIST 27 TROUBLESHOOTING QUICK REFERENCE GUIDE 28
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 4
THIS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MUST STAY WITH
EQUIPMENT.
PLEASE REGISTER YOUR EQUIPMENT WARRANTY AND START-UP RECORD ONLINE
AT WWW.DEKKERVACUUM.COM
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 5
CUSTOMER SERVICE
Contact information
935 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 46360-5672
TEL.: 219-861-0661 – FAX: 219-861-0662 – TOLL-FREE: 888-925-5444
Bus. Hours: 7:30 a.m. – 4:30 p.m. CST
Website: www.DEKKERvacuum.com
E-mail: [email protected]
Order Information When calling for service, parts or system information always have the pump or system model number and
serial number(s) ready. Refer to the bill of lading or the gold-colored system information plate attached to the
system (see image below).
Gold-colored system information plate
Parts should be purchased from the nearest authorized DEKKER Vacuum Technologies, Inc. (hereafter
referred to as DEKKER) representative (visit www.dekkervacuum.com to find a distributor near you via the
Distributor Locator) or from the vacuum pump system supplier. If, for any reason parts, cannot be obtained in
this manner, contact the factory directly.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 6
INTRODUCTION The Vmax oil-sealed liquid ring vacuum pump system has been designed to give you safe, reliable, trouble-free
service provided some of the basic maintenance guidelines as set out in this manual are followed. Compared to
other vacuum pump systems, the Vmax oil-sealed liquid ring vacuum pump system offers the advantages of no
metal-to-metal contact between the impeller and casing. Grease lubricated bearings are mounted external to
the pumping chamber, isolated by mechanical shaft seals. This means that the pump requires no internal
lubrication. However, a vacuum pump is a rotating piece of equipment and operators must exercise good
judgment and follow proper safety procedures to avoid damage to the equipment or personal injury. Please
review and follow all instructions in this manual before attempting to install, start or operate equipment.
SAFETY All vacuum pumps, systems and/or compressors (hereafter referred to as the Product) offered by DEKKER
have been designed and manufactured for safe operation. However, the responsibility for safe operation rests
with those who use and maintain these products. The safety department where the product is installed should
establish a safety program based on OSHA, federal, state, and local codes. It is important that due
consideration be given to hazards which arise from the presence of electrical power, hot liquids, harmful gases,
and rotating equipment. Proper installation and care of protective devices is essential to safe system operation.
These safety procedures are to be used in conjunction with the instructions contained in this manual.
WARNING: DO NOT PUMP OXYGEN or oxygen rich mixtures with these pumps -
EXPLOSION HAZARDS!
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 7
THEORY OF OPERATION The DEKKER Vmax oil-sealed liquid ring vacuum pump system includes our high efficiency liquid ring vacuum
pump. The impeller assembly is the only moving part which rotates freely in the casing without metal-to-metal
contact which means no additional lubrication is required. The function of the sealing liquid is to create a liquid
piston action used to produce vacuum and to remove the heat of compression. The seal fluid, hereafter
referred to as oil, in the system circulates in a closed loop passing through an air- or water-cooled heat
exchanger that removes the heat of compression. The discharge separator/reservoir holds the seal fluid and
incorporates the DEKKER DX-5 or DX-7 patented high-efficiency separator arrangement to separate the seal
fluid from the air or gases discharged by the pump. See “Piping and Instrument Diagram” of the Vmax oil-sealed
liquid ring vacuum pump system below.
Piping and Instrument Diagram
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 8
STORAGE Keep the system in a cool dry environment and close the seal fluid isolation valve as shown on page 17. Plug all
open ports to keep out dirt and foreign objects. Every 2 weeks rotate the impeller by rotating the shaft by
hand 2 ¼ turns.
INITIAL FREIGHT RECEIPT AND INSPECTION Before a system ships from DEKKER, it is thoroughly tested, and will not be released unless it passes our
Quality Control standards. All pumps are thoroughly inspected and are not released unless they pass our
Quality Control standards. Once the product is received and signed for in Good Condition, DEKKER cannot
be held accountable for undiscovered, unclaimed damage that is a result of freight transit. It is the responsibility
of the receiver to thoroughly inspect and test the product for functionality upon delivery. The customer should
take photos of the product as it arrives and send to DEKKER and the freight carrier if there are any issues. The
party who selected the shipper is responsible for filing the freight claim. Failure to report these issues within
the freight carriers’ undiscovered damage window can result in non-acceptance of freight claims. DEKKER does
keep photos of all systems, as shipped, to assist in freight claims. Report any damage immediately to
Key items to inspect:
Is the product received as requested? Are all parts, accessories, and components delivered?
Was the skid or crating received in good condition? Check for cosmetic damage.
Check wiring inside of control panel. Are all wires should be terminated and connections tight? (If
applicable)
Check control panel components. Are they tight on DIN rail and/or other mounts/fasteners?
Are there any leaks or puddles around the pump? Specify hose, piping or housing leak.
System must be given an initial startup test as soon as possible after delivery. This is to ensure that the motor
has not shifted out of alignment during transit as well as to verify that electrical components are functioning
without fault – Variable Frequency Drive (VFD), Programmable Logic Controllers (PLC), panel cooling fans,
transducers.
INSTALLATION
Overview The design of the piping system, foundation layout, and plant location are the responsibility of the purchaser.
DEKKER Vacuum Technologies, Inc. and its representatives may offer advice, but cannot assume responsibility
for operation and installation design.
Please consult the factory or a specialist skilled in the design of plant layout, system piping design, and
foundation design. The installer should carefully read this manual before installing the equipment. DEKKER or
your authorized dealer can provide start up assistance in most instances for a fee. Contact DEKKER for
hourly/daily service rates.
Unpacking Upon receipt of pump or system, immediately inspect for signs of damage. Carefully remove packing or crating
from around pump or system. Be sure to keep equipment in upright position.
Lifting Lift the equipment carefully and with weight evenly distributed. DEKKER is not responsible for equipment that
has been damaged through mishandling or dropping.
Location Install the unit in a well ventilated and dust free area. The pump or system should be a minimum distance of 3
feet from surrounding walls to allow for checking fluid level, temperatures, pressures and general servicing.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 9
Mounting The pump or system must be installed on a level surface in the horizontal position. The foundation must be
designed to support the total unit weight, without any settlement or crushing, be rigid and substantial enough
to absorb any equipment vibration, maintain true alignment with any drive mechanism, and must permanently
support the system baseplate at all points. The vacuum system must be leveled and secured with anchor bolts.
Anchor bolts must be of adequate size to withstand the mechanical stresses exerted on it.
Systems 50 HP and larger should also be grouted into position per local codes. The foundation should be
constructed to allow for ¾ to 1-½ inch of grout. The baseplate is set on shims and the grout is poured
between the foundation and the baseplate. To have the required body to support the baseplate, grout should
be at least ¾ inch thick.
The number and location of shims will be determined by the design of the baseplate. Firm support should be
provided at points where weight will be concentrated and at the anchor bolt locations. Use enough, and large
enough, shims to provide rigid support. Baseplates are usually designed with openings to allow pouring grout.
When the baseplate has been shimmed, leveled, and the anchor bolts have been snugly tightened, a dam is
constructed around the foundation to contain the grout. The dam level should be at least ½ inch above the top
surface of the shims. Grout should be poured inside and around the outside of the baseplate and leveled. Allow
the grout to dry for a minimum of 48 hours before tightening the anchor bolts.
Please note that the pump/motor coupling and V-belt units will need to be realigned prior to start-up, with
the exception of monoblock units.
Ventilation Locate the unit in an area with sufficient airflow and accessibility. To prevent excessive ambient temperature
rise, it is imperative to provide adequate ventilation. Cooling is an important aspect of reliable equipment
operation and it is therefore important to install the unit in a reasonably cool area where the temperature does
not exceed 104°F (40°C). For higher ambient temperatures contact the factory.
Typical system operating temperature is between 140°-185°F. Minimum oil temperature should not be below
45°F.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 10
Electrical Preparation
Wire Size Chart (AWG) by Vmax Horsepower
Recommended Wire Size and Disconnect Size for Vmax Systems
Vmax
FLC NEC Tables Volt. Copper AWG (kcmil) Recommended Conduit
Size in Inches
Recommended Fused
Disconnect (Amps)
Recommended Class J
Fuse System Serv.
Model No. HP Fact. 200V 230V 460V Tol. 200V 230V 460V 200V 230V 460V 200V 230V 460V 200V 230V 460V
VMX0023MA1 1.5 1.15 6.9 6 3 ±10% 14 14 14
1/2"
15 15 15 12 10.5 5.25
VMX0023KA1 1.5 1.15 6.9 6 3 ±10% 14 14 14 15 15 15 12 10.5 5.25
VMX0036MA1 3 1 11 9.6 3.7 ±10% 14 14 14 20 20 15 19.2 16.8 8.4
VMX0036KA1 3 1.15 11 9.6 4.8 ±10% 14 14 14 20 20 15 19.2 16.8 8.4
VMX0063MA1 5 1.15 17.5 15.2 7.6 ±10% 12 12 14 40 30 15 30.6 26.6 13.3
VMX0063KA1 5 1.4 17.5 15.2 7.6 ±10% 12 12 14 40 30 15 30.6 26.6 13.3
VMX0083MA1 5 1.15 17.5 15.2 7.6 ±10% 12 12 14 40 30 15 30.6 26.6 13.3
VMX0083KA1 5 1.4 17.5 15.2 7.6 ±10% 12 12 14 40 30 15 30.6 26.6 13.3
VMX0103MA1 7.5 1 25.3 22 11 ±10% 10 10 14 50 40 20 44.2 38.5 19.2
VMX0103KA1 7.5 1.3 25.3 22 11 ±10% 10 10 14 50 40 20 44.2 38.5 19.2
VMX0153MA1 10 1 32.2 28 14 ±10% 8 10 14 60 50 30 56.3 49 24.5
VMX0153KA1 10 1.28 32.2 28 14 ±10% 8 10 14 60 50 30 56.3 49 24.5
VMX0203KA1 15 1.3 48.3 42 21 ±10% 6 6 10 3/4" 3/4" 1/2" 90 80 40 84.5 73.5 36.7
VMX0303KA1 20 1.25 62.1 54 27 ±10% 4 6 10 1” 3/4" 1/2" 110 100 50 109 94.5 47.2
VMX0303KA1-20 20XP 1.15 62.1 54 27 ±10% 4 6 10 1” 3/4" 1/2" 110 100 50 109 94.5 47.2
VMX0453KA1 25 1.3 78.2 68 34 ±10% 3 4 8 1” 1” 1/2" 140 120 60 137 119 59.5
VMX0453KA1-20 25XP 1.15 78.2 68 34 ±10% 3 4 8 1” 1” 1/2" 140 120 60 137 119 59.5
VMX0553KA1 40 1.3 120 104 52 ±10% 0 1 6 1.25 1.25 3/4" 220 190 100 210 182 91
VMX0553KA1-20 40XP 1.15 120 104 52 ±10% 0 1 6 1.25 1.25 3/4" 220 190 100 210 182 91
VMX0753KA1 50 1.28 150 130 65 ±10% 0 0 4 1.5 1.5 1” 270 230 115 262 227 114
VMX1003KA1 60 1.15 177 154 77 ±10% 0 0 3 2 1.5 1” 320 270 140 310 269 135
VMX1103KA1 75 1.15 221 192 96 ±10% 300 0 1 2 2 1.25 390 340 180 387 336 168
VMX1203KA1 100 1.15 285 248 124 ±10% 500 350 0 2.5 2.5 1.25 510 440 230 499 434 217
NOTES: 1. Based on no more than three single insulated conductors rated 0-2000 volts. 6. If fuse is not a standard size, choose the next higher standard size.
2. Conduit sizes shown at 9.6%. Fill does include ground conductor if required (over 60 amperes). 7. If disconnect is not a standard size, choose the next higher standard size.
3. Wire sizes are based on NEC Table 310.15.b.16 @ 75°C rated conductors.
4. Approved trade size conduit or metal tubing.
5. Above information is general information. Per NEC tables please confirm motor FLA does not exceed FLC.
Note: Fuse and disconnect sizes are for vacuum pump only. For main disconnect and fuse sizes for systems
with a circulation pump and fan, multiply the FLC of the vacuum pump motor by 175% then add the FLC for
the circulation pump and fan to get the fuse size. Disconnect must be sized to fit fuse.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 11
All system wiring is performed at the factory if a control panel is supplied and installed on the skid. Check area
classification to ensure all electrical enclosures comply with code. Required customer wiring is minimal, but
should be done by a qualified electrician in compliance with OSHA, National Electric Code and any other
applicable local electrical code concerning switches, fused disconnects, etc. DEKKER includes a wiring diagram
in the control panel for use by the installer. DEKKER recommends a main disconnect switch be fitted between
the vacuum system and the incoming power.
After the electrical wiring connections are completed, check the incoming voltage to make sure the incoming
voltage is the same as the vacuum system voltage. Line voltage should be within the voltage tolerance as
specified on the motor or to local code. Check the system for proper motor rotation. The direction of
rotation is marked by an arrow on the motor or pump housing. Jog the motor by pressing the ON button and
then the OFF button. If the rotation is incorrect, switch any two of the three main power leads (three phase
power) on the contactor inside the control panel. Failure to do so could result in serious equipment damage.
WARNING: Install, ground, and maintain equipment in accordance with the National Electrical
Code and all applicable federal, state and local codes.
WARNING: For NFPA 99 hospital and generator applications, please shut down the vacuum
pumps prior to generator testing. The rapid stop and restart may cause damage to the pump
and/or motor and cause damage to electrical panel and related components.
Pipe Connection and Sizing Before installation, remove all protective inserts on the pump suction and discharge. Piping connected to the
system must be installed without imposing any strain on the system components. Improperly installed piping
can result in misalignment, general operating problems and pump failure. Use flexible connectors where
necessary. Piping must be cleaned of debris before installation.
DEKKER recommends CPVC piping as discharge temps may exceed +170°F. CPVC is rated for 200°F max, and
PVC is only rated for 140°F max. Schedule 40 PVC piping is generally acceptable for the inlet connections.
Inlet Piping Note: Install a temporary screen at the pump inlet flange at first start-up to protect the unit against carryover
of pipe debris and welding slag. The screen must be removed after the initial run-in period.
Inlet piping should be at least the size of the pump inlet. Install the system as close as possible to the process to
minimize losses due to the length of the suction line. If the system has to be installed further away from the
process, be sure the inlet piping is properly sized to minimize the overall line pressure drop. For more
information consult your authorized dealer or contact the factory.
Pump systems operating in parallel on a common manifold must each have a manual or automatic shut-off valve
and a suitable check valve installed in the suction line close to the pump suction flange. This allows each
individual system to be isolated when it is not in operation. The line size of the manifold should be a minimum
equal to the sum of the individual system pipe areas.
Systems are supplied with an inlet check valve as standard. This valve is installed close to the pump suction
flange to prevent back flow of process gas and seal fluid when the pump is stopped.
If the inlet gas pumped contains dust or foreign particles, a suitable 5 micron (or finer) inlet filter should be
installed at the inlet port. For more information consult your authorized dealer or the factory.
If the possibility exists that the pump inlet can become closed during operation it will be essential to install
some type of vacuum relief valve (anti-cavitation valve) so that air can enter the pump inlet. Never run a pump
with a closed suction. This causes hydraulic knock / cavitation and can damage the pump.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 12
Discharge Piping Discharge piping must be at least the size of the separator discharge. Do not discharge the exhaust gases from
the pump system into the area where the system is installed. Vapors pulled over from the process could be
hazardous. Install an exhaust line of at least the same diameter as the discharge connection on top of the
separator reservoir leading outside. See the “Discharge Piping Diagram” as shown below.
For vacuum pump systems operating in parallel on a common discharge, DEKKER recommends the installation
of a suitable check valve close to the separator discharge flange of each unit. Discharge check valves should be
a low differential pressure type with positive shutoff. This will prevent discharge gasses from back flowing to
other systems. When discharging more than one pump in a common discharge line and/or over a long distance,
oversize pipe accordingly.
Discharge Piping Diagram
Cooling Water Piping Water-cooled systems require an adequate supply of cooling water at a maximum of 85°F and a minimum
supply pressure of 20 psig. If the cooling water temperature is higher or available pressure lower, contact your
authorized dealer or the factory.
The cooling water outlet connection of the heat exchanger may be fitted with an optional automatic
temperature control valve, which regulates the cooling water flow rate depending on pump operating
temperature. The valve is preset at the factory. To raise the system operating temperature, turn the valve-
adjusting screw counter-clockwise. To lower operating temperature, turn clockwise. Normal system operating
temperature is between 140°-185°F. Minimum oil temperature should not be below 45°F. The valve will only
open when the system operating temperature is reached.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 13
START-UP PROCEDURES
1 Ensure all shipping plugs and/or paper covers are
removed from system and tagging information is
followed for successful startup.
2 Ensure seal fluid isolation valve is open (NOTE: There
may be more than one valve). This valve is located
below the separator and/or near the y-strainer.
Seal Fluid Isolation Valve
3 Jog the motor briefly and check direction of rotation.
The direction of rotation is marked by an arrow on the
motor or pump housing. If direction is incorrect,
switch any two of the three leads at the power
connection (three phase only). The correct direction of
rotation is clockwise facing the pump from the drive
end and counter-clockwise if viewed from the non-
drive end.
4A Check drive coupling alignment. Angular and parallel
alignment should be within the following chart
allowances (see next page, item 4A.1). Consult the
factory for specific system size alignment. Mono-block
units do not require any field adjustment (motors are
C-face mounted).
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 14
4A.1
Alignment Chart
Pump
Model
Sleeve
Size
Maximum
RPM
Parallel
Misalignment
Angular
Misalignment "B"
-- 3 9200 0.010 0.035 1.188
-- 4 7600 0.010 0.043 1.500
DV0036 5 7600 0.015 0.056 1.938
DV0060-80 6 6000 0.015 0.070 2.375
DV0100-0150 7 5250 0.020 0.081 2.563
DV0200-0300 8 4500 0.020 0.094 2.938
DV0450 9 3750 0.025 0.109 3.500
DV0550 10 3600 0.025 0.128 4.063
-- 11 3600 0.032 0.151 4.875
-- 12 2800 0.032 0.175 5.688
-- 13 2400 0.040 0.195 6.625
-- 14 2200 0.045 0.242 7.750
-- 16 1500 0.062 0.330 10.250
Figure 1
B Dimension
Figure 2
Parallel Measurement
Figure 3
Angular Measurement
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 15
4B For units utilizing V-belt drives, make sure the sheaves
are properly installed and aligned before attempting to
tension the drive. The V-belts should be placed over the
sheaves and in the grooves without forcing them over the
sides of the grooves. The tensioning steps below can be
used for all types of V-belts, all cross sections and
number of belts and all types of construction.
Avoid excessive heat (140°F and higher); belt life will
be shortened. Never switch or mix belts from one
groove to another on the sheaves. Do not use belt
dressing. Sheaves should remain free of oil and grease.
When replacing belts install an identical set.
For more specific V-belt tensioning guidelines consult
factory.
Sheave alignment should be checked by placing a straight
edge or tight cord across the sheave faces so that it
touches all four points of contact. Ordinarily, a
misalignment of more than one-half of one degree (one
eighth inch in one foot) will adversely affect belt life.
Improper sheave alignment produces uneven wear on
one side of the belt, causes the belt to roll over in the
sheaves or throws the entire load on one side of the belt,
stretching or breaking the cords on that side.
Tensioning a Drive - General Rules of Tensioning
1. Ideal tension is the lowest tension at which the belt
will not slip under peak load conditions.
2. Check tension frequently during the first 24-48
hours of run-in operation.
3. Over tensioning shortens belt and bearing life.
4. Keep belts free from foreign material which may
cause slip.
5. Make V-Drive inspection on a periodic basis. Tension
belt when slipping. Never apply belt dressing as this
will damage the belt and cause early failure.
6. If the unit is idle for an extended period of time, the
tension on the belts should be removed.
Simple Tensioning Procedure
1. Measure the span length.
2. At the center of the span apply a force
(perpendicular to the span) large enough
to deflect the belt 1/64”, for every inch of
span length. For example, one deflection
of a 100 inch span would be 100/64 or 1-
9/16 inches.
3. Compare the force you have applied with
the values given in Table 4B.1 on the next
page. If the force is between the values for
normal tension, and 1-1/2 times normal
tension, the drive tension should be
satisfactory. A force below the value for
normal tension indicates an under
tensioned drive. If the force exceeds the
value for 1-1/2 times normal tension, the
drive is tighter than it needs to be. 4. After the proper operating tension has
been applied to the belts, double check
the following: A) Parallel position of the
sheave shafts. B) Correct alignment of
sheave grooves.
Tensioning rules and procedure
courtesy of Dodge PT Manual MN-
4002
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 16
4B.1
Tensioning Table
Tensioning Table and installation image courtesy of Dodge PT Manual MN-4002
Notes:
1. Use approximately 130% of above values to tension a new set of belts.
2. Use closest sheave diameter for sizes not shown.
Speed Range Diameter 1.0 1.5 2.0 4.0+
1200-3600 2.2 2.2 2.5 2.7 3
1200-3600 2.5 2.6 2.9 3.1 3.6
1200-3600 3 3.1 3.5 3.7 4.2
1200-3600 4.1 3.9 4.3 4.5 5.1
1200-3600 5.3 4.6 4.9 5.1 5.7
1200-3600 6.9 5 5.4 5.6 6.2
1200-3600 4.4 6.5 7.5 8 9
1200-3600 5.2 8 9 9.5 10
1200-3600 6.3 9.5 10 11 12
1200-3600 7.1 10 11 12 13
900-1800 9 12 13 14 15
900-1800 14 14 15 16 17
900-1800 12.5 18 21 23 25
900-1800 14 21 23 24 28
700-1500 17 24 26 28 30
700-1500 21.2 28 30 32 34
400-1000 24.8 31 32 34 36
900-1800 7.1 8.5 9.5 10 11
900-1800 9 10 11 12 13
900-1800 14 12 13 14 15
700-1200 21.2 14 15 16 17
900-1800 12.5 18 21 23 25
900-1800 14 21 23 24 28
700-1500 17 24 26 28 30
700-1200 21.2 28 30 32 34
400-1000 24.8 31 32 36
5V
8V
V-Belt SectionSmall Sheave Deflection Force
3VX
5VX
8VX
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 17
5 Check fluid level in separator reservoir. The fluid level
should be at the FILL LINE on the sight gauge. If
gauge level is low, do not add oil. Systems are
given a full charge of oil at DEKKER factory. Before
filling, run unit at normal vacuum conditions for a few
minutes, then shut down and fill to correct fluid level.
Note: Fluid level may vary depending on vacuum level.
Deep Vacuum (>25”HgV) requires more oil, but Low
Vacuum (<15”HgV) can blow oil into outer shell. Both
of these conditions will appear as lower oil in the
sight-glass. Refer to Troubleshooting for additional
details.
6 If your system contains an inlet valve in the vacuum
line, set it to approximately 3/4 closed, and start
pump. If valve is not supplied, one should be installed.
Warning: Do not operate pump with suction open
to atmosphere for long periods of time.
Note: Ideal vacuum is > 15”HgV at sea level.
Note: This is an Air Inlet Valve, not an Oil Valve.
7 Run the pump for a few minutes then turn it off.
If unit is equipped with vacuum relief valve, valve is
typically preset at 27”HgV at sea level.
Note: For pump priming capacity, see the
Maintenance Section of this manual, page 22.
However, pumps are primed from the factory.
8 With the pump shut off, check fluid level again. The
fluid level should be at the FILL LINE on the sight
gauge. Add fluid if necessary.
Warning: Never remove the oil fill plug while the
pump is running.
9 Start pump again and check that discharge pressure on
the separator does not exceed 2 psig when operating
under vacuum conditions. A pressure higher than 2
psig is a sign of high back pressure in the discharge
pipe system. Display might show a higher pressure at
start-up at low vacuum (0-10"HgV).
Note: Nominal operation should be less than 2 psig.
10 Check the voltage and motor current. They should be
within the specifications for the motor. Amperage
should be checked at the Overload.
Note: This test should also be performed under
normal system operating conditions.
DANGER: HIGH VOLTAGE!
Lethal shock hazard present.
USE EXTREME CAUTION!
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 18
11 After 15-30 minutes of operation, check pump
operating temperature, which should be in the 140°-
185°F range.
12 Remove temporary inlet screen.
SHUT DOWN PROCEDURES To stop vacuum system follow the procedure as outlined below.
Push the STOP button or turn switch to the OFF position. The inlet check valve will prevent fluid from the
system from flowing back into the inlet manifold.
Note: If inlet piping could be under vacuum for an extended period of time without the pump running, inlet
piping should be vented to atmosphere unless the process requires otherwise.
Note: Close the seal fluid isolation valve and the pump inlet isolation valve during extended periods of storage
or when transporting. See Storage section on page 8 for details. Open valves before starting system.
MAINTENANCE
WARNING: Before attempting any maintenance such as changing the fluid, disconnect all power from the
system by switching off the main breaker, isolate all energy sources and allow system to cool.
Pump Bearing Lubrication Refer to pump series manual for details.
Motor Bearing Lubrication (where required) For information regarding motor bearing lubrication, refer to the motor maintenance and operation manual.
Inlet Filter (If Installed) Check after first 8 hours of operation. Clean or replace inlet filter element every 1000 to 3000 hours
depending on application or if excessive pressure drop is noticed. In some applications it may be necessary to
clean inlet filter more often. Clean filters by gently knocking off into a dust bin. Brush filter free of debris and
clean with a wet/dry vacuum cleaner. DO NOT USE COMPRESSED AIR TO CLEAN ANY FILTERS!
CAUTION: Be careful not to allow foreign material to fall in the pump suction opening when removing the
filter cartridge. Horizontal filter installation is recommended to prevent this. Filters must be disposed of
properly as they might contain toxic substances carried over from the process.
Seal Fluid The system(s) are shipped with DEKKER's specially formulated Vmaxol seal fluid. These fluids are specifically
designed for use in DEKKER Vmax systems, providing low viscosity, excellent water separating qualities, anti-
foaming and low oxidation. DEKKER recommends that Vmaxol sealing fluids be used for obtaining ultimate
performance from the Vmax vacuum pump system and to preserve the extended 3-year warranty period.
When using Standard Vmaxol it is recommended that the seal fluid be changed every 10,000 hours of
operation. When using Synthetic/Food grade Long-life Vmaxol, seal fluid may be changed every 15,000 hours of
operation. Extreme operating conditions may require more frequent changes.
Oil Change Procedure To change the fluid, first make sure there is no power to the system and the pump is off. We recommend that
the fluid be changed when the system is at operating temperature. CAUTION: Oil will be hot.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 19
To ensure that all seal fluid is removed, drain at all ports labeled below. Failure to service any of these ports
will eventually result in premature failure of the system.
When charging the system with new fluid, make sure that the pump is filled with oil to the shaft centerline
level. Do not fill the pump above the shaft centerline. Starting the pump with oil level above the shaft
centerline may result in shaft or impeller damage or failure. You can add oil by removing the suction or
discharge flange and pouring oil through pump suction or discharge port.
Fill the reservoir to the FILL LINE on the sight gauge. Open the air bleed valve on the heat exchanger to
remove all air from the system. Run the pump for a few minutes, stop and check fluid level again. If required,
add additional fluid to the reservoir. Be sure not to overfill. Unscrew the Brass Push-Lock Fitting, and
check port ‘D’ for excess oil.
Check seal fluid level in the reservoir. A high fluid level could mean a build-up of water in the reservoir, which
should be drained. Since water settles below oil, drain from port ‘C’ until only the oil drains. Check every
500 hours.
VMX0203-VMX0553 A. Pump Drain (Ball Valve)
B. Y-Strainer (Hex Plug/Mesh Screen)
C. Inner Shell Drain (Pipe/Hex Plug/Ball Valve)
D. Outer Shell Drain (90 Degree Brass Push-Lock Fitting) Sight Glass does not read from this Outer Shell.
Before adding oil when you see it low in the sight glass, check for carried-over oil here.
E. Heat Exchanger Drain (Hex Plug/Ball Valve)
A
Prime
Pump
B
D C
E
Oil Fill
(Reservoir)
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 20
VMX0063-VMX0153 A. Pump Drain (Typically Plugged) Not Shown; Face of Pump 6 o’clock position
B. Y-Strainer (Hex Plug/Mesh Screen)
C. Main Tank Drain (Ball Valve)
D. Separator Scavenge Line Drain (90 Degree Brass Push-Lock Fitting)
E. Heat Exchanger Drain (Hex Plug/Ball Valve)
VMX0036 A. Pump Drain (Typically Plugged)
B. Y-Strainer (Hex Plug/Mesh Screen)
C. Main Tank Drain (Ball Valve)
D. Separator Scavenge Line Drain (90 Degree Brass Push-Lock Fitting) Not Shown; Under Separator Element
Housing
E. Heat Exchanger. Disconnect Hoses/Piping to Drain
A
B
C
E
Prime
Pump
Oil Fill
(Reservoir)
D
A
B
C
D
Prime
Pump Oil Fill
(Reservoir)
E
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 21
Standard System Capacities
System Capacity
(gal) System
Capacity
(gal)
VMX0036MA1-XX 1.6 gal VMX0303KA1-XX 11 gal
VMX0063MA1-XX 4.5 gal VMX0453KA1-XX 16 gal
VMX0083MA1-XX 4.75 gal VMX0553KA1-XX 17 gal
VMX0103MA1-XX 6 gal VMX0653KA1-XX 34 gal
VMX0103KA1-XX 6.5 gal VMX0753KA1-XX 34 gal
VMX0153MA1-XX 6.25 gal VMX1003KA1-XX 37 gal
VMX0153KA1-XX 7.25 gal VMX1103KA1-XX 37 gal
VMX0203KA1-XX 10.5 gal VMX1203KA1-XX 39.5 gal
Priming the Pump Below is a table showing the amount of seal fluid needed to prime the pump.
Pump Fluid Volume
(qt.)
Fluid Volume
(gal)
DV0035 0.5 0.1
DV0060 1.5 0.4
DV0080 1.9 0.5
DV0100 2.2 0.5
DV0150 4.7 1.2
DV0200 5.6 1.4
DV0300 7.2 1.8
DV0450 11.1 2.8
DV0550 14.6 3.7
DV0750 18.4 4.6
DV1200 36.1 9
Complimentary Oil Analysis DEKKER offers oil analysis to customers, regardless of the age of their system, at no charge. Collect
approximately 4 fluid ounces from the machine, and secure it in any type of clean bottle. On the bottle or a
packing list, please include the following: system serial number, the type of oil, the run hours on the oil and
machine, and note any problems you are having with the system if applicable.
Also make sure to include your contact information with email address. After the analysis is complete,
DEKKER will provide a report of the condition of the oil, along with recommendations.
Send to:
DEKKER Vacuum Technologies, Inc.
935 S. Woodland Ave.
Michigan City, IN 46360
United States
ATTN: After Sales
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 22
Oil Solenoid Valve The oil solenoid valve, if equipped, is located in seal fluid piping near the pump. The valve prevents oil from
filling the pump on shutdown. It is critical that this valve operates properly. If the valve malfunctions in an open
position, oil will flow back into the pump when the system is shut off. This will result in hard starting and
possible equipment damage.
If the valve is stuck in the closed position, poor vacuum performance will result. If the pump is operated for
longer than a minute without oil, internal damage may occur. The condition of the solenoid valve interior will
mirror the condition of the oil reservoir housing. If there is a buildup of sludge, varnish, or particulate in the oil
reservoir, the solenoid valve body may be likewise contaminated.
Seal Fluid Strainer After the first 50 hours of operation, clean the strainer in the seal fluid line. This is done to remove any debris
carried over into the system from the process. Clean and inspect the strainer every 1000-3000 hours
depending on application or if excessive oil discharge temperature (above 185°F) is indicated. An increase in
pump discharge oil temperature is an indication of low oil flow and normally is an indication of strainer
blockage. If cleaning of strainer does not decrease temperature check the seal fluid line for blockage.
Separator Element The separator element(s) is located in the separator reservoir. The purpose of the separator element is to
remove the oil from the discharge air. Replace the element every 10,000 hours or once a year. Earlier
replacement may be necessary when the back pressure is higher than 4 psig. High back pressure could be a
result of contaminates on the separator element due to oil varnish or contaminated inlet gas stream.
Replacement may vary depending on application.
NOTE: Thread-in style filters are installed hand-tight. Do not over-tighten with a wrench.
Separator Element Oil Return Line The separator element oil return lines are 1/8” to 3/8” transparent tubing. The purpose of these lines is to
remove excessive oil build-up from inside the separator and separator element. If excessive smoking or oil mist
is present check the oil return lines for blockage and replace if necessary. Also check that the steel section of
oil return line located on top of the separator reservoir is cut at a 45° angle and is touching the bottom of the
separator element.
Shaft Seals All DEKKER oil-sealed liquid ring vacuum pumps are fitted with mechanical shaft seals. Mechanical seals do not
require maintenance unless there is more than a small amount of leakage. To define this we differentiate
between the following:
Weepage: Mechanical seals work by having two flat surfaces pushed together by axial force from the closing
mechanism and by product pressure in the seal chamber. When the seal is in operation, the seal fluid lubricates
the two faces. This thin film of lubrication protects the faces of the seal from heat and excessive wear, but it
can also allow for a small amount of leakage across the seal face. This small leakage is called a “weep”. While a
weep has rather arbitrary limits, it is commonly considered to be a leakage rate of less than one drop of liquid
every minute. Seal weeps are not covered under warranty.
Leakage: A leakage rate of more than one drop per minute is considered to be a “leak”. Seal leakage is
normally a result of a build-up of abrasive particles carried over in the pump suction. These particles cause
excessive wear on the seal faces. Leakage caused by wear and tear is not covered under warranty.
Seal replacement is addressed in the assembly and disassembly instruction for the specific pump model used.
Consult factory for assistance.
Particles and debris that enter seal fluid can work into the sealing faces of the mechanical seals. Any debris
pulled into the pump will mix with the seal fluid.
VMAX systems equipped with mechanical seal scavenger tubing must be monitored for oil flow through the
lines after startup. If oil is present in the scavenger tubing, the seals may be leaking and replacement should be
scheduled.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 23
MAINTENANCE SCHEDULE To help ensure trouble free system operation, a basic maintenance schedule consisting of the following system
checks is recommended.
First 8 Hours of Operation Check oil level
Check inlet filter element if installed
Clean strainers and remove temporary inlet screen
Check for water in sight gauge and drain if necessary
Check piping for signs of oil leakage and tighten if necessary
Check belt tension, if applicable
Daily Check oil level
Inspect for leaks
Check for water in sight gauge and drain if necessary
Check piping for signs of oil leakage and tighten if necessary
Check for oil in scavenger tubing. VMAX systems equipped with mechanical seal scavenger tubing
must be monitored for oil flow through the lines after startup. If oil is present in the scavenger tubing,
the seals may be leaking and replacement should be scheduled.
500 Hours of Operation Under normal operating conditions repeat the daily steps above and,
Check inlet filter element if installed
Clean strainers and remove temporary inlet screen
1000 Hours of Operation Check back pressure on separator element; it should not exceed 4 psig. Change separator element if
back pressure exceeds 4 psig. Also, check discharge pipe system for blockage.
Clean or replace inlet filter element.
Remove debris from pump housing, motor fan guard, and heat exchanger.
Applicable to pumps equipped with grease fittings located on each bearing housing. Grease bearings
with a quality #2 lithium grease. Do not over-grease, 3 to 4 pumps with a grease gun is sufficient
under normal conditions.
10,000 Hours of Operation Every 10,000 hours, or annually, change seal fluid. Use DEKKER Vmaxol seal fluid. Life of Standard
Vmaxol is 10,000 hours of operation. Synthetic/Food grade long-life Vmaxol may be changed every
15,000 hours of operation.
Change separator element if back pressure exceeds 4 psig.
Check coupling element for wear. Replace if worn.
Clean strainer in seal fluid line.
30,000 Hours of Operation Every 30,000 hours, or every 5 years, it is recommended that you replace the vacuum pump’s
mechanical seals and bearings as preventative maintenance. This should be done by a DEKKER
authorized distributor or properly trained service technician.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 24
Devarnishing The operating life of the unit is greatly enhanced based on the quality of the seal fluid. Oxidized or darkened
seal fluid is a sign of trouble. Plugged filters reduce performance and may damage pump. Periodic maintenance
will offer the best protection for your equipment.
DEKKER offers a specially formulated devarnishing compound Proclean 39V for oil-sealed liquid ring pumps and
systems. Procedure for using Proclean 39V and SDS sheet are included with the product.
NOTE: Varnished pumps are not covered under warranty.
ACCESSORIES AND PROTECTIVE DEVICES (IF INCLUDED)
Accessories The following accessories are available for Vmax oil-sealed liquid ring vacuum pump systems.
Inlet or Discharge Flexible Connectors (optional): These flex connectors are used in piping
systems to eliminate vibration transmission from machinery throughout the piping network.
Vibration Isolators (optional): Vibration isolators are used to eliminate vibrations, noise and shock
transmission from machinery to the floor. Floor-mount type vibration isolators are used for Vmax
vacuum pump systems.
System Isolation Valve (optional): This valve may be installed on the vacuum receiver tank or
vacuum pump manifold. Usually the valve is used to isolate the vacuum system from the piping
network.
Inlet Filter (optional): An inlet filter may be installed on the Vmax oil-sealed vacuum pump systems
to prevent carry-over of particles into the pump.
Vacuum Relief Valve (optional): This valve may be installed on the pump suction manifold or on
the receiver. The vacuum relief valve is used to protect the vacuum pump from closed suction which
can damage the pump.
Protective Devices The following protective devices are available to protect the unit from being damaged and to help with
maintenance:
High Temperature Switch (optional): The switch will signal when the temperature of the seal
fluid is exceeding the shut-down level. The switch will shut the unit down. The unit will not restart
until the alarm condition is acknowledged and is reset. The switch is a “snap disc” type of switch that
is normally closed. When the temperature reaches the maximum set point, the switch will open. Once
the switch has opened, there is a 10°-20°F differential that the temperature will need to drop to, in
order for the switch to close.
High Back-Pressure Switch (optional): This switch is installed on the discharge of the separator.
When the back-pressure reaches a pre-determined level (4 psi), the switch will signal the control
panel. A high back-pressure light may be installed on the control panel, which, when illuminated,
signals that the exhaust element in the vacuum pump needs to be replaced. Note that the high back-
pressure switch will not shut the unit down, but the exhaust element must be replaced as soon as
possible.
Low Oil Level Switch (optional): This switch is installed in the separator/reservoir of the liquid
ring vacuum pump. It is a float type of switch. If the level switch is triggered, the affected pump will
shut down. The LOW OIL LEVEL light on the control panel will be illuminated. The low level switch
will be wired into the main alarm of the panel. The alarm will have to be reset to restart the pump.
When filling the system with oil, make sure that the power to the pump is off because if the alarm
reset button has been reset and the level switches contacts close while filling the pump, the pump will
start-up automatically.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 25
High Oil Level Switch (optional): This switch is installed in the separator/reservoir of the liquid
ring vacuum pump. It is a float type of switch. If the level switch is triggered, the affected pump will
shut down. The HIGH OIL LEVEL light on the control panel will be illuminated. The high level switch
will be wired into the main alarm of the panel. The alarm will have to be reset to restart the pump.
When draining the system, make sure that the power to the pump is off because if the alarm reset
button has been reset and the level switches contacts close while draining the pump, the pump will
start-up automatically.
TROUBLESHOOTING The following is a basic troubleshooting guide and not all options may be included. Service should be done by a
DEKKER authorized distributor or a properly trained service technician. Each unit is tested and checked at the
factory. Always indicate model and serial number when calling. The model and serial number is viewable on the
gold-colored information plate attached to the unit.
WARNING: Before attempting any maintenance such as changing the fluid, disconnect all power from the
unit by switching off the main breaker, isolate all energy sources and allow unit to cool. All electrical work
should be done by a qualified electrician in compliance with OSHA, National Electric Code and any other
applicable local electrical code.
Start-Stop Problems
Unit will not start 1. No main AC power. Confirm that the main AC power disconnect is ON and supplying power to the
control panel. This can be measured with an AC voltmeter at the power supply terminals in the
control panel. Refer to the electrical control panel diagram supplied with the system. If main AC power
is not present at the power supply, verify incoming AC voltage on the motor contactor.
2. Check if the disconnects or circuit breaker is switched on.
3. Check the overload setting on the starter and fuses.
4. Check the small auxiliary contactor on the face of the main contactor. A loose connection or debris
can cause faulty operation. Remove, clean, and reattach. Tighten wires.
5. Check alarm reset, light should be off.
6. Ensure that the proper voltage is supplied and that the wire size is correct.
7. Check electrical control panel. Make sure that all wires are tight. Wires may vibrate loose during
shipment or operation.
8. Check low oil level switch. Add oil to reservoir if needed.
9. Check high oil level switch. Drain oil from reservoir if needed.
10. Check if the pump has seized by rotating the coupling by hand (disconnect power first). If a rubbing
noise or binding is observed, contact authorized dealer.
Unit shuts down while running 1. Check operating temperature.
2. Check the overload setting on the starter and fuses.
3. Ensure that the proper voltage is supplied and that the wire size is correct.
4. Check for loose electrical connections.
5. Check the vacuum set points.
6. Check low oil level switch. Add oil to reservoir if needed.
7. Check high oil level switch. Drain oil from reservoir if needed.
8. Check if the pump has seized by rotating the coupling by hand (disconnect power first). If a rubbing
noise or binding is observed, contact authorized dealer.
9. Clean oil strainer.
10. Check if pump operates against high back pressure (> 4 psig), if so replace oil separator element.
11. Check the small auxiliary contactor on the face of the main contactor. A loose connection or debris
can cause faulty operation. Remove, clean, and reattach. Tighten wires.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 26
Vacuum Problems
Unit Operates, but does not achieve desired vacuum level 1. Stop system and disconnect power.
2. Check if the inlet valve is open and inlet filter is clean.
3. Ensure that no lines are open to the atmosphere, causing loss of vacuum.
4. Check for leaks in piping systems, using conventional leak detection methods.
5. Ensure oil level is correct, pump is primed and filled with oil to the shaft centerline only.
6. Check if the oil isolation valve is open.
7. Check if the oil solenoid valve is working.
8. Check the vacuum set points.
9. Check setting of vacuum relief valve and adjust as needed. The valve is typically preset at 27”HgV at
sea level.
10. Check if the motor rotation is correct. Rotation should be clockwise (facing pump from motor
side) and marked by an arrow on the motor or pump housing. If incorrect, switch any two of the
three main power leads on the contactor inside the control panel.
Overheating Problems
Unit overheats or operates above 200°F 1. Stop system and disconnect power.
2. Check the oil cooler and fan. Clean cooler externally with compressed air. Ensure that 12" of space
is available in front of the cooler and that the ambient temperature is below 104°F.
3. Check if the oil isolation valve is open.
4. Check if the oil solenoid valve is working.
5. Ensure oil level is correct, pump is primed and filled with oil to the shaft centerline only.
6. Check if the temperature control valve is working and that oil is flowing through the cooler.
CAUTION: Oil will be HOT.
7. Clean oil strainer.
8. Check if oil cooler is blocked internally with solids passed through from the process.
Unit overheat on start-up in low ambient temperatures 1. Stop system and disconnect power
2. Oil tends to thicken in temperatures of 45°F and below. Place heat tape and insulation on the fluid
seal line from the heat-exchanger to the pump inlet.
3. Also insulate the seal-fluid solenoid valve or change oil to synthetic fluid contact authorized dealer
or the factory for more information.
Noise and Vibration Problems
The system is making an abnormal noise or sound 1. Stop system and disconnect power.
2. Check the coupling and/or element for proper alignment. If worn or damaged, replace.
3. Check if the bearings are greased. Rotate the coupling by hand, which should rotate freely. If a
rubbing noise or binding is observed, contact authorized dealer.
4. Ensure oil level is correct, pump is primed and filled with oil to the shaft centerline only.
5. Check setting of vacuum relief valve and adjust as needed. The valve is typically preset at 27”HgV at
sea level.
6. Check the inlet filter and clean if necessary. Pump may hydraulically knock / cavitate if filter is
blocked.
7. Check if the inlet valve is closed. The pump may hydraulically knock / cavitate if inlet is closed.
8. Check vacuum level. Pump may hydraulically knock / cavitate as a result of too deep of a vacuum
level.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 27
System is vibrating excessively 1. Stop system and disconnect power.
2. Check the coupling and/or element for proper alignment. If worn or damaged, replace.
3. Check if the bearings are greased. Rotate the coupling by hand, which should rotate freely. If a
rubbing noise or binding is observed, contact authorized dealer.
4. Check if baseplate is properly supported. Uneven floor will distort baseplate, which could cause
vibrating problems.
5. Check that the mounting bolts of pump, coupling, fan and cooler are not loose. Tighten as required.
6. Check belt alignment on belt drive systems.
Oil Problems
System uses excessive oil or produces an oil-mist Stop system and disconnect power.
1. Check the oil return line from the separator for blockage to ensure that oil flows from separator to
vacuum pump.
2. Check if pump operates against high back pressure (> 4 psig), if so replace oil separator element.
3. Normal and continuous operating vacuum level should be 15”HgV or deeper. If not, contact
authorized dealer or the factory.
4. Check for an excessive amount of water vapor carried over from the process in the oil reservoir by
slowly draining from separator drain. Remove all excess water.
DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-S01 Rev. A 28
Troubleshooting Quick Reference Guide