1
COGENERATION STORAGE TANK Submial Sheet CST-Sub-01 Job Name: __________________________________ Location: __________________________________ Engineer: __________________________________ Agent/Wholesaler: ______________________________ Contractor: __________________________________ NOTES: Model No. _____________ Gal. Cap. _____________ Tank Working Construction: ________________ Pressure: _____________ Dimensions:________________ Lining: _____________ Equipment Tag(s): _____________________________________________ COGENERATION STORAGE TANK 10/19—Printed in U.S.A. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 45° CONTROLLER BRACKET WIRING CHASE 3/8" NPT FLANGE (4X) SENSOR BULBWELL 45° 90° 2" NPT FLANGE UPPER SYSTEM CONNECTION 1" NPT FLANGE RELIEF VALVE 3/4" AIR VENT AUX BULBWELL 2" NPT FLANGE LOWER SYSTEM CONNECTION 61.05 (2X) 75.43 12.30 (2X) 135° 2" NPT FLANGE (2X) AUX HEAT 2" NPT FLANGE (2X) AUX HEAT 1" FIP DHW OUTLET CST150-002 ONLY 28.50 1" FIP DHW INLET CST150-002 ONLY RATING PLATE 3.32 12.80 62.05 47.30 61.05 1" DRAIN Standard Features > Five Year Limited Warranty (See Warranty for details) > 125 PSI Working Pressure > Auto Air Vent > Storage Controller > Temperature Sensors > Jacketed and Insulated > 150 Gallon Capacity Optional Equipment Temperature and Pressure Gauge Lifting Lugs Pressure Relief Valve: 30 PSI 50 PSI 75 PSI 100 PSI 125 PSI Approx. Ship Model Weight Number Dia. Height Description (lbs.) CST150 28” 76” Hydronic Storage Tank 650 CST150-DHW 28” 76” Indirect DHW Storage Tank 650

Submittal Sheet CST-Sub-01green.lochinvar.com/_linefiles/CST-Sub-01.pdfStandard Features > Five Year Limited Warranty (See Warranty for details) > 125 PSI Working Pressure > Auto Air

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Submittal Sheet CST-Sub-01green.lochinvar.com/_linefiles/CST-Sub-01.pdfStandard Features > Five Year Limited Warranty (See Warranty for details) > 125 PSI Working Pressure > Auto Air

COGENERATION STORAGE TANK

Submittal Sheet CST-Sub-01

Job Name: __________________________________

Location: __________________________________

Engineer: __________________________________

Agent/Wholesaler: ______________________________

Contractor: __________________________________

NOTES:

Model No. _____________ Gal. Cap. _____________Tank WorkingConstruction: ________________ Pressure: _____________

Dimensions:________________ Lining: _____________

Equipment Tag(s):

_____________________________________________

COGENERATION STORAGE TANK

10/19—Printed in U.S.A.

Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000

Lochinvar.com

45°

CONTROLLERBRACKET

WIRINGCHASE

3/8" NPTFLANGE (4X)SENSORBULBWELL

45° 90°

2" NPT FLANGEUPPER SYSTEM CONNECTION

1" NPT FLANGERELIEF VALVE

3/4" AIR VENT

AUXBULBWELL

2" NPTFLANGELOWERSYSTEMCONNECTION

61.05(2X)

75.43

12.30(2X)

135°

2" NPT FLANGE(2X) AUX HEAT

2" NPTFLANGE (2X)AUX HEAT

1" FIPDHW OUTLETCST150-002 ONLY

28.50

1" FIPDHW INLETCST150-002ONLY

RATINGPLATE

3.32

12.80

62.05

47.30

61.05

1" DRAIN

Standard Features> Five Year Limited Warranty (See Warranty for details)

> 125 PSI Working Pressure

> Auto Air Vent

> Storage Controller

> Temperature Sensors

> Jacketed and Insulated

> 150 Gallon Capacity

Optional EquipmentTemperature and Pressure Gauge

Lifting Lugs

Pressure Relief Valve:

30 PSI

50 PSI

75 PSI

100 PSI

125 PSI

Approx. Ship Model Weight Number Dia. Height Description (lbs.)

CST150 28” 76” Hydronic Storage Tank 650 CST150-DHW 28” 76” Indirect DHW Storage Tank 650