Upload
kamal-wiggins
View
25
Download
0
Tags:
Embed Size (px)
DESCRIPTION
Suggested Engineering Changes to Modular Coil Lead Area. James H. Chrzanowski June 13, 2006. Lead Area Design Changes. Lead Area upper chill plate Lead Area lower cladding Improve tracking distance hardware to jumpers Eliminate floating Hardware Jumper studs Power bus joint. - PowerPoint PPT Presentation
Citation preview
1
Suggested Engineering Changes to Modular Coil Lead
Area
James H. Chrzanowski
June 13, 2006
2
Lead Area Design Changes
• Lead Area upper chill plate
• Lead Area lower cladding
• Improve tracking distance hardware to jumpers
• Eliminate floating Hardware– Jumper studs– Power bus joint
3
Lead Area Chill Plates
- If possible eliminate upper chill plate
- Difficult to insulate
- Potential problem in future??
4
Lead Area Cladding- Lower
• Replace lower cladding in lead area with G-11cr [eliminate floating pieces]
5
Power Bus Tie-in Area
• Improve tracking distance- install barrier
• Eliminate floating through bolts- tie studs to one side of joint
6
Improve Tracking Distance
• Improve tracking distance
• Install 032 in. thick G-11cr insulator under jumpers covering bolts
7
Lead Area Floating Hardware-Link the [3] jumper studs to the bottom jumper using G-11cr [1] insulator and copper plate [2]
-Tie plate to jumper 1 lug [3] using wire
3
1
2
8