1 Suggested Engineering Changes to Modular Coil Lead Area James H. Chrzanowski June 13, 2006

Suggested Engineering Changes to Modular Coil Lead Area

Embed Size (px)

DESCRIPTION

Suggested Engineering Changes to Modular Coil Lead Area. James H. Chrzanowski June 13, 2006. Lead Area Design Changes. Lead Area upper chill plate Lead Area lower cladding Improve tracking distance hardware to jumpers Eliminate floating Hardware Jumper studs Power bus joint. - PowerPoint PPT Presentation

Citation preview

Page 1: Suggested Engineering Changes to Modular Coil Lead Area

1

Suggested Engineering Changes to Modular Coil Lead

Area

James H. Chrzanowski

June 13, 2006

Page 2: Suggested Engineering Changes to Modular Coil Lead Area

2

Lead Area Design Changes

• Lead Area upper chill plate

• Lead Area lower cladding

• Improve tracking distance hardware to jumpers

• Eliminate floating Hardware– Jumper studs– Power bus joint

Page 3: Suggested Engineering Changes to Modular Coil Lead Area

3

Lead Area Chill Plates

- If possible eliminate upper chill plate

- Difficult to insulate

- Potential problem in future??

Page 4: Suggested Engineering Changes to Modular Coil Lead Area

4

Lead Area Cladding- Lower

• Replace lower cladding in lead area with G-11cr [eliminate floating pieces]

Page 5: Suggested Engineering Changes to Modular Coil Lead Area

5

Power Bus Tie-in Area

• Improve tracking distance- install barrier

• Eliminate floating through bolts- tie studs to one side of joint

Page 6: Suggested Engineering Changes to Modular Coil Lead Area

6

Improve Tracking Distance

• Improve tracking distance

• Install 032 in. thick G-11cr insulator under jumpers covering bolts

Page 7: Suggested Engineering Changes to Modular Coil Lead Area

7

Lead Area Floating Hardware-Link the [3] jumper studs to the bottom jumper using G-11cr [1] insulator and copper plate [2]

-Tie plate to jumper 1 lug [3] using wire

3

1

2

Page 8: Suggested Engineering Changes to Modular Coil Lead Area

8