ESD
(Answer all questions in this section)
1. Which items generate static electricity? Mark for Review (1) Points
Work surfacesClothingPeopleAll of the above (*)
Correct
2. Why are ESD "soft failures" the most serious type of failures? Mark for Review (1) Points
They represent 60% of failuresThey represent 40% of all failuresThe damage is immediate and easily detectedThe damage is not immediately noticed or detected (*)
Correct
3. The leading cause of semiconductor failure is due to? Mark for Review (1) Points
The increased use of 45nm technology in manufacturing semiconductorsDamage during shipmentsElectrostatic discharge (*)Incorrect power supply used with the system
Correct
4. Standing up can generate up to 1,400 volts. Mark for Review (1) Points
True (*)False
Correct
5. Which of the following descriptions best defines ESD? Mark for Review (1) Points
The ability of a part to withstand a static charge without failure.Damage to system components due to the use of an incorrect power supplyThe sudden transfer, or discharge, of electricity from one object to another. (*)The failure of an item that would result in failure of the system.
Correct
Page 1 of 24
ESD
(Answer all questions in this section)
6. Low humidity environments reduce the voltage generated from friction and moving, Mark for Review
(1) Points
TrueFalse (*)
Correct
7. Which of the following is NOT one of the rules for preventing ESD damage? Mark for Review
(1) Points
Handle electronic components only when you are properly groundedKeep items away from electronic componentsStore and transport ESD-sensitive items in static-shielding containersMake sure your grounding straps are not in contact with your skin. (*)
Correct
8. What is the difference between a soft failure and a hard failure? Mark for Review
(1) Points
Soft failures occurs in the software. Hard failures occurs in the hardware.Soft failures weaken components and is difficult to detect. Hard failures are easy to identify and trace back to ESD. (*)Hard failures represent 80% of all failuresSoft failures are easily detected and rapidly fixed. Hard failures are difficult to identify and fix.
Correct
Sun Blade 6000 Storage Module M2(Answer all questions in this section)
9. Sun Blade Storage Module M2 is a disk blade containing ....... slots that can be populated with disk drives that use the Serial Attached SCSI (SAS) or Serial Advanced Technology Attachment (SATA) protocols.
Mark for Review (1) Points
328 (*)1624
Correct
10. Disk drives can be removed with the storage module in or out of the chassis. Mark for Review
(1) Points
True (*)False
Correct
Page 2 of 24
Sun Blade 6000 Storage Module M2
(Answer all questions in this section)
11. Select the tools and options that are used for diagnostics. (Select all that apply) Mark for Review
(1) Points
(Choose all correct answers)
MegaRAID Storage Manager (MSM) software (*)BIOS-based LSI configuration utilityCMM ILOM (*)Sun Validation Test Suite (VTS) software (*)LEDs and indicators (*)
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
12. You cannot mix SAS-1 and SAS-2 NEMs in the Sun Blade Modular System chassis. Mark for Review
(1) Points
True (*)False
Correct
13. The host server module must have a supported ............... (disk controller) installed to access the storage module. Mark for Review
(1) Points
CMM ILOMSAS-2 REM (*)SAS-2 disk drivesSAS-2 NEM
Correct
14. Which of the following is also referred to as an HBA or an initiator? Mark for Review (1) Points
NEMCMM ILOMREM (*)ESM
Correct
15. Sun Blade Zone Manager configurations only affect host-to-storage access, not the actual saved data on disks. Mark for Review
(1) Points
True (*)False
Correct
Page 3 of 24
Sun Blade 6000 Storage Module M2
(Answer all questions in this section)
16. Which of the following protocols is not supported by Sun Blade Storage Module M2? Mark for Review
(1) Points
Serial Management Protocol (SMP)Serial Attached SCSI (SAS)SCSI Enclosure Services (SES)Simple Serial Protocol (SSP) (*)Serial SCSI Protocol (SSP)
Correct
17. How many storage blades are supported in a single Sun Blade 6000 Modular System? Mark for Review
(1) Points
6109 (*)8
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
18. Which of the following are Sun Blade Storage Module M2 components? (Select all that apply) Mark for Review
(1) Points
(Choose all correct answers)
SAS-2 NEM (*)SATA FMods (*)SAS-2 disk drivesVMware (*)
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
19. The MSM software can be used from a management client to monitor which of the following: (Select all that apply) Mark for Review
(2) Points
(Choose all correct answers)
SAS-2 REMStorage module enclosure temperature, voltage, and faults (*)Mechanical or SSD drives (*)FMods (*)
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
20. The Sun Blade 6000 Modular System chassis includes its own Service Processor (SP) software called ............ Mark for Review
(1) Points
LSI Fusion-MPT IRCMM ILOM (*)LSI MegaRAID Storage ManagerBIOS-based LSI Configuration Utility
Correct
Page 4 of 24
Sun Blade 6000 Storage Module M2
(Answer all questions in this section)
21. .............is a user-installable high performance solid-state storage device that acts like a SAS disk and uses flash memory technology Mark for Review
(1) Points
for increased data access speeds
NEMCMMFMod (*)ESM
Correct
22. A server module with SAS-1 devices can access the networking component of a SAS-2 NEM. Mark for Review
(1) Points
True (*)False
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
23. Sun Blade Storage Module M2 also supports SAS-1 NEMs along with SAS-2 NEMs. Mark for Review
(1) Points
TrueFalse (*)
Correct
24. While discovery in Vela1 is host initiated, in Vela2, it is self discovery. Mark for Review
(1) Points
True (*)False
Correct
25. The Sun Blade Zone Manager feature of the CMM ILOM can assign storage that is internal to a server module. Mark for Review
(1) Points
TrueFalse (*)
Correct
Page 5 of 24
Sun Blade 6000 Storage Module M2
(Answer all questions in this section)
26. The storage module contains how many internal FMod slots? Mark for Review (1) Points
24 (*)83216
Correct
27. SAS-2 and SATA drives can be used on the same storage blade. Mark for Review (1) Points
TrueFalse (*)
Correct
28. 9NEMHydra-2 is the code name for which of the following NEMs? Mark for Review (1) Points
Sun Blade 6000 10GbE Multi-Fabric NEMSun Blade 6000 Virtualized Multi-Fabric 10GbE M2 NEM (*)Sun Blade 6000 Virtualized Multi-Fabric 10GbE NEMSun Blade 6000 Multi-Fabric NEM
Correct
Sun Blade X6270 and X6270 M2 Server Module Architecture and Features(Answer all questions in this section)
29. Which diagnostics test the host hardware while the server's OS is booting? Mark for Review
(1) Points
POST (*)hostdiagspdiagUboot
Incorrect. Please refer to “Sun Blade X6270 and X6270 M2 Server Module courses” for more information.
30. Which state of the Power/OK LED indicates that the OS has booted successfully on the server blade? Mark for Review
(1) Points
STANDBY BLINKSTEADY ON (*)SLOW BLINKOFF
Correct
Page 6 of 24Sun Blade X6270 and X6270 M2 Server Module Architecture and Features
(Answer all questions in this section)
31. What is the maximum memory supported by server blade assuming you use 8-GByte DIMMs? Mark for Review
(1) Points
144 GBytes (*)128 GBytes256 GBytes64 GBytes
Correct
32. Which disk types are supported by the server blades? Mark for Review (1) Points
SAS and SATA (*)SASnone
SATA
Correct
33. Which ILOM account extended role allows the user to create ILOM accounts? Mark for Review
(1) Points
consoleadminuser management (*)reset and host control
Correct
34. How many DIMMs slots are supported per memory channel? Mark for Review (1) Points
3 (*)412
Correct
35. To replace an FMOD the state of the ESM power LED must be? Mark for Review (1) Points
FlashingONOFF (*)does not matter
Correct
Page 7 of 24
Sun Blade X6270 and X6270 M2 Server Module Architecture and Features
(Answer all questions in this section)
36. How many disk slots are available on the front of each server blade? Mark for Review
(1) Points
4 (*)862
Correct
37. What can the Windows Event Viewer be used for under the Windows OS? Mark for Review
(1) Points
view the system driversview the system accountsview the system logs (*)view the system processes
Correct
38. Which of the following components CAN be hot swapped? Mark for Review (1) Points
CPUHDD or SSD (*)FMODDIMM
Correct
39. Which ILOM screen displays a list of failed server components? Mark for Review (1) Points
statusinventoryfailed componentsfault management (*)
Correct
40. To enable Service Mode you need to perform all but one of these Mark for Review
steps on the server blade? (1) Points
Gather the product serial number and ILOM versionGenerate the service password from a designated websiteCall Oracle service for the sunservice password (*)Set the session mode to service
Correct
Page 8 of 24
Sun Blade X6270 and X6270 M2 Server Module Architecture and Features
(Answer all questions in this section)
41. The FMODs are resident on the sever blade motherboard. Mark for Review (1) Points
TrueFalse (*)
Correct
42. Which of serial management port parameters is NOT a factory default on the server blade? Mark for Review
(1) Points
no parity1 stop bit9600 baud7 data bits (*)
Correct
43. Which blade chassis supports these server blades? Mark for Review (1) Points
Sun Blade 8000 Modular SystemSun Netra CT900 ServerSun Blade 6000 Modular System (*)All the blade systems listed
Correct
44. Which components is found on the X6270 server blade but not on the X6270 M2 server blade? Mark for Review
(3) Points
USB portsFMODcompact flash disk drives (*)system battery
Correct
45. How do you view the CPLD firmware version of its main board? Mark for Review (1) Points
BIOS screenUsing flashupdateILOM command or screenUsing the cpld_update script (*)
Correct
Page 9 of 24
Sun Blade X6270 and X6270 M2 Server Module Architecture and Features
(Answer all questions in this section)
46. Which of the following components requires an Allen wrench for its replacement on the X4800 server? Mark for Review
(1) Points
system batteryDIMMCPU (*)FMOD
Correct
47. What type of serial management port connector is supported by the server blade front faceplate? Mark for Review
(1) Points
USBUCP (*)DB9RJ-45
Correct
48. To enable the sunservice account you need to set the session parameter to on the server blade? Mark for Review
(1) Points
onserviceenabledescalation (*)
Incorrect. Please refer to “Sun Blade X6270 and X6270 M2 Server Module courses” for more information.
Sun Blade(TM) X6240 Server Module Installation, Administration, and Troubleshooting(Answer all questions in this section)
49. Which indicator on the server blade signals that it is ready to be removed? Mark for Review
(1) Points
Ready-to-Remove (*)Service Action RequiredOKLocator
Correct
50. How do you light a DIMM Fault indicator? Mark for Review (1) Points
Program it from ILOM.Program it from the SP.Push the Fault Remind button on the CMM.
Push the Fault Remind button on the server blade. (*)
Correct
Page 10 of 24
Sun Blade(TM) X6240 Server Module Installation, Administration, and Troubleshooting
(Answer all questions in this section)
51. Which management tool is used by the Sun Blade X6240 Server Module? Mark for Review
(1) Points
ELOMILOM (*)LOMALOM
Correct
52. What is the default root password for the SP ILOM? Mark for Review (1) Points
<CR>cangetinchangeme (*)root
Correct
53. Which ILOM command is used to download and install firmware? Mark for Review (1) Points
<tt>load</tt> (*)<tt>download</tt><tt>ftp</tt><tt>install</tt>
Correct
54. How many alerts can be configured? Mark for Review (1) Points
131415 (*)12
Incorrect. Please refer to “ Sun Blade X6240 Server Module Installation, Administration, and Troubleshooting ” for more information.
55. Which command is used to make an account in ILOM? Mark for Review (1) Points
<tt>create</tt> (*)<tt>make</tt><tt>vadduser</tt><tt>add</tt>
Correct
Page 11 of 24
Sun Blade(TM) X6240 Server Module Installation, Administration, and Troubleshooting
(Answer all questions in this section)
56. What type of I/O paths originate at the server modules, go through the midplane, and to the I/O modules? Mark for Review
(1) Points
PCI ExtendedInfiniBandHypertransportPCI Express (*)
Incorrect. Please refer to “ Sun Blade X6240 Server Module Installation, Administration, and Troubleshooting ” for more information.
57. How many GbE ports are supported on a NEM slot? Mark for Review (1) Points
2 (*)143
Incorrect. Please refer to “ Sun Blade X6240 Server Module Installation, Administration, and Troubleshooting ” for more information.
58. Which OS must be running on the Sun Blade X6240 Server Module in order to execute the troubleshooting tool SunVTS? Mark for Review
(1) Points
Windows.Linux.The OS cannot be running when this software is executed.Solaris 10 OS (*)
Correct
SPARC T3-Based Server Maintenance(Answer all questions in this section)
59. What is the minimum ILOM version that supports the SPARC T3 servers? Mark for Review
(1) Points
2413 (*)
Correct
60. The SPARC T3 servers supports FMODs. Mark for Review (1) Points
True
False (*)
Correct
Page 12 of 24
SPARC T3-Based Server Maintenance
(Answer all questions in this section)
61. Which diagnostic tool is available from Solaris? Mark for Review (1) Points
diagspdiagSunVTS (*)faultmgmt
Correct
62. The FMA logs may provide you a course of action. Mark for Review (1) Points
True (*)False
Correct
63. Which connector supports the serial port on the SPARC T3-1B? Mark for Review (1) Points
Front panel DB9 connectorFront panel UCP connector (*)Front panel RJ-45 connectorFront panel DB25 connector
Correct
64. What Solaris command can be used to view the system configuration? Mark for Review
(1) Points
netcfgnetconfigprtdiag (*)ifconfig
Correct
65. Which is the highest Ethernet interface speed supported by all the SPARC T3 servers? Mark for Review
(1) Points
1-GbE100-MbE10-GbE (*)100-GbE
Correct
Page 13 of 24
SPARC T3-Based Server Maintenance
(Answer all questions in this section)
66. IPMI is supported on all the SPARC T3 servers. Mark for Review (1) Points
True (*)False
Correct
67. The server's OS can be booted which ILOM command? Mark for Review (1) Points
bootloadstart (*)osboot
Correct
68. Which CPU type is supported on these servers? Mark for Review (1) Points
Intel XeonSPARC T3 (*)UltraSPARC T2AMD Opteron
Correct
69. Which FMA command displays hardware errors in the server from ILOM? Mark for Review
(1) Points
show errorsshow hwerrorsshow faultsshow faulty (*)
Correct
70. The XAUI interfaces come from which component? Mark for Review (1) Points
Ethernet controller chipsSouthbridge chipThere are no XAUI interfacesCPU chips (*)
Correct
Page 14 of 24
SPARC T3-Based Server Maintenance
(Answer all questions in this section)
71. Which are the interface used between the CPUs and the PCIe HUB chip? Mark for Review
(1) Points
PCI Express 2.0 (*)Quick Path Interconnects (QPI)HyperTransport (HT)Front-Side Buses
Correct
72. Which file contains the Solaris system event logs? Mark for Review (1) Points
/var/log/messages/usr/adm/log/var/adm/log/usr/log/messages (*)
Incorrect. Please refer to “WZTB-5160: SPARC T3 Based Servers Maintenance ” for more information.
73. Which software can be accessed from Solaris as well as ILOM? Mark for Review (1) Points
FMA (*)prtdiagSunVTSASR
Correct
74. ILOM, BIOS and IPMI maintain logs? Mark for Review (1) Points
True (*)False
Correct
75. How many USB connectors are there on each SPARC T3 server? Mark for Review (1) Points
4
5 (*)23
Incorrect. Please refer to “WZTB-5160: SPARC T3 Based Servers Maintenance ” for more information.
Page 15 of 24
SPARC T3-Based Server Maintenance
(Answer all questions in this section)
76. Which ILOM command displays sensor and status information? Mark for Review (1) Points
faultmgmt (*)spdiagstatussnapshot
Correct
77. Which of the following is not a FRU or CRU? Mark for Review (1) Points
MotherboardCPU (*)DIMMsBattery
Correct
Sun Blade 6000 Modular System Installation, Administration and Troubleshooting(Answer all questions in this section)
78. Which of the following is a FRU and NOT a CRU? Mark for Review (1) Points
I/O Chassis (*)Power supplyServer moduleRear fan module
Correct
79. Which command is used to make change the root password in ALOM? Mark for Review
(1) Points
chpwordchangeuserpassword (*)password
Correct
80. What type of I/O paths originate at the server modules, go through the midplane, and to the I/O modules? Mark for Review
(1) Points
InfiniBandHypertransportPCI ExtendedPCI Express (*)
Correct
Page 16 of 24
Sun Blade 6000 Modular System Installation, Administration and Troubleshooting
(Answer all questions in this section)
81. Which OS must be running on the Sun Blade X6220 Server Module in order to execute the troubleshooting tool SunVTS? Mark for Review
(1) Points
LinuxWindowsSolaris 10 OS, Update 2. (*)
The OS cannot be running when this software is executed.
Correct
82. How many Sun Blade 6000 Modular Systems fit in a 42 rack unit, 19-inch rack? Mark for Review
(1) Points
FourTwoOneThree (*)
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
83. What is the name of the user that must execute the troubleshooting scripts on the SP under /usr/local/bin? Mark for Review
(1) Points
guestscriptrunnerrootsunservice (*)
Correct
84. Which is NOT a fault management component? Mark for Review (1) Points
IndicatorsSensorsDiagnosis engineFans (*)
Correct
85. Where do you set up the netboot port within the Sun Blade X6220 Blade Module? Mark for Review
(1) Points
SP ILOM
OBPCMM ILOMBIOS (*)
Correct
Page 17 of 24
Sun Blade 6000 Modular System Installation, Administration and Troubleshooting
(Answer all questions in this section)
86. How many EM slots are dedicated to each server module? Mark for Review (1) Points
ThreeFourOneTwo (*)
Correct
87. Which modules need to be removed from the chassis before disk replacement? Mark for Review
(1) Points
Server bladeNEMNo modules (*)CMM
Correct
88. Which of the following commands would put you in the appropriate directory to assign a static IP address to the network management port?
Mark for Review (1) Points
cd /CH/networkcd /CMM/netcfgcd /SP/networkcd /CMM/network (*)
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
89. How many power supplies can be removed and still keep the system powered up? Mark for Review
(1) Points
1 (*)243
Correct
90. The type of processors on the Sun Blade T6300 Server Modules are: Mark for Review (1) Points
UltraSPARC IIIUltraSPARC T1Intel ZeonAMD Opteron (*)
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
Page 18 of 24
Sun Blade 6000 Modular System Installation, Administration and Troubleshooting
(Answer all questions in this section)
91. What is the default network configuration protocol that the CMM uses, if available? Mark for Review
(1) Points
CMM is only available through a serial port connection.Static network configuration parameters.Dynamic Host Configuration Protocol (DHCP). (*)CMM protocol.
Correct
92. How many processors does a Sun Blade X6220 Server Module have? Mark for Review
(1) Points
12 (*)34
Correct
93. Which indicator on the server blade signals that it is ready to be removed? Mark for Review
(1) Points
Service action neededReady-to-remove (*)LocatorOK
Correct
94. Which ILOM command is used to download and install firmware? Mark for Review (1) Points
ftpload (*)installdownload
Correct
95. Which modules need to be removed from the chassis before DIMM replacement? Mark for Review
(1) Points
No modulesNEMsServer blade (*)CMMs
Correct
Page 19 of 24
Sun Blade 6000 Modular System Installation, Administration and Troubleshooting
(Answer all questions in this section)
96. Which of the following options to hdt can be used to write output to a log file? Mark for Review
(1) Points
-a-q-e-l (*)
Correct
97. How do you light a DIMM fault indicator? Mark for Review (1) Points
Program it from the SP.Push the fault remind button on the CMM.Program it from ILOM.Push the fault remind button on the server blade. (*)
Correct
Sun Blade X6275 Server Module Architecture and Features(Answer all questions in this section)
98. The Sun Blade X6275 Server Module supports onboard 2.5 inch SAS disk drives. Mark for Review
(1) Points
TrueFalse (*)
Correct
99. The Sun Blade X6275 Server Module motherboard is field replaceable? Mark for Review
(1) Points
True (*)False
Correct
100. Which diagnostic tool is available from the ILOM sunreserve account? Mark for Review
(4) Points
SunVTSdiagspdiag_vayu (*)faultmgmt
Correct
Page 20 of 24
Sun Blade X6275 Server Module Architecture and Features
(Answer all questions in this section)
101. How many CPU chips does each node of the Sun Blade X6275 support? Mark for Review
(1) Points
2 (*)341
Correct
102. Which new ILOM command displays sensor and status information? Mark for Review
(3) Points
statusfaultmgmt (*)snapshot
spdiag
Correct
103. Which file contains the Linux system event logs? Mark for Review (1) Points
/usr/log/messages/usr/adm/log/var/adm/log/var/log/messages (*)
Correct
104. How can you reset the BIOS password back to factory default? Mark for Review (1) Points
Cycling the J42 jumper for the specific node. (*)Configuring a new password from within IPMIConfiguring a new password from within ILOMCycling the CMM jumper
Correct
105. Which UCP connector supports node 0 serial port? Mark for Review (1) Points
Both UCPBottom UCPNeither UCPTop UCP (*)
Correct
Page 21 of 24
Sun Blade X6275 Server Module Architecture and Features
(Answer all questions in this section)
106. Which new ILOM command persists across reboots of the SP? Mark for Review (1) Points
StopPersistPortsharing (*)Start
Correct
107. What Linux command can be used to view the network configuration? Mark for Review
(1) Points
ifconfig (*)netcfgipconfignetconfig
Correct
108. ILOM, BIOS and IPMI maintain system event logs? Mark for Review (1) Points
True (*)False
Correct
109. Which of the following are FRUs? Mark for Review (1) Points
BatteryFlash DIMMsDIMMsCPU and heat sink (*)
Correct
110. The node 0 SAS disk slot is located? Mark for Review (1) Points
In rear of the server blade on the bottom slotIn front of the server blade on the top slotIn front of the server blade on the bottom slotIn rear of the server blade on the top slot (*)
Correct
Page 22 of 24
Sun Blade X6275 Server Module Architecture and Features
(Answer all questions in this section)
111. How many NEMs does each server blade node support? Mark for Review (1) Points
1 (*)234
Incorrect. Please refer to “Sun Blade X6275 Server Module Courses courses” for more information.
112. Which Preboot command can be used to configure the ownership of the serial port? Mark for Review
(1) Points
edit (*)modifychangeowner
Correct
113. Which CPU type is supported on the Sun Blade X6275? Mark for Review (1) Points
AMD OpteronSun SPARC T2 Plus
Sun SPARC T2 PlusIntel Nahelam-EP Xeon2 (*)
Correct
114. The D0 memory DIMM slot is the one furthest from the CPU? Mark for Review (1) Points
TrueFalse (*)
Correct
115. Which are the interface used between the CPUs and the PCIe HUB? Mark for Review (1) Points
PCI ExpressHyperTransport (HT)Quick Path Interconnects (QPI) (*)Front-Side Buses
Correct
Page 23 of 24
Sun Blade X6275 Server Module Architecture and Features
(Answer all questions in this section)
116. What chassis supports the Sun Blade X6275 Server Module? Mark for Review (1) Points
Sun Blade 6000 Modular SystemSun Blade 6048 Modular System (*)Netra CT900Sun B1600
Correct
117. The Flash DIMM LED is a fault LED? Mark for Review
(1) Points
TrueFalse (*)
Incorrect. Please refer to “Sun Blade X6275 Server Module Courses courses” for more information.
Page 24 of 246. Power supply
replacement does NOT affect air flow in which CRU?
Mark for Review (1) Points
EM
Server module (*)
CMM
NEM
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more informatio
n.
7. Which indicator on the EM signals that it is ready to be removed?
Mark for Review (1) Points
Service action needed
Locator
OK (*)
Ready-to-remove
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
9. Which of the operating systems is NOT supported by the Sun Blade X6220 Blade
Mark for Review
(1) Points
Module?
RHEL AS4 (64-bit)HPUX 4.0 (*)Solaris 10 U3 (64-bit)Win 2003 EE ( 64-bit)
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
11. How do you light a processor fault indicator?
Mark for Review
(1) Points
Program it from the SP.
Push the fault remind button on the CMM.Program it from ILOM.
Push the fault remind button on the server blade. (*)
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for
more information.
12. The two types of I/O modules supported by the Sun Blade 6000 Modular System are (Choose 2)?
Mark for Review
(1) Points
(Choose all correct answers)
Motherboard
ExpressModule (*)
Network Express module (*)Standard IO module
Server module
Chassis Management module
Incorrect. Please refer to “Sun Blade 6000 Modular System Installation, Administration and Troubleshooting” for more information.
24. A/An ........... provides Mark for
backup power to save cache disk data when system power is removed or interrupted.
Review (1) Points
FMod
NEM
ESM (*)
CMM
Incorrect. Please refer to “Sun Blade 6000 Storage Module M2 Courses” for more information.
53. Which tool do you use to upgrade the firmware on ILOM and BIOS on the server blade?
Mark for Review
(1) Points
BIOS
IPMI
OBP
ILOM (*)
Incorrect. Please refer to “Sun Blade X6270 and X6270 M2 Server Module courses” for more information.
68. The Mark for
Windows system event logs can be displayed using the Log Viewer.
Review (1) Points
True
False (*)
Incorrect. Please refer to “Sun Blade X6275 Server Module Courses courses” for more information.
71. The physical replacement of the Sun Blade X6275 Server Module is the same as any other C48 server blade?
Mark for Review
(1) Points
True (*)
False
Incorrect. Please refer to “Sun Blade X6275 Server Module Courses courses” for more information.
72. Which is a new ILOM menu being introduced with the Sun Blade X6274 Server Module? Mark for Review
(1) Points
Preboot (*)
UBoot
BIOS Boot
ILOM Boot
Correct
73. What is minimum number of DIMMs supported per CPU? Mark for Review
(1) Points
2
1
4
3 (*)
Incorrect. Please refer to “Sun Blade X6275 Server Module Courses courses” for more information.
74. The Flash DIMM LED is a fault LED?
Mark for Review
(1) Points
True
False (*)
Correct
75. What is the minimum ILOM version that supports the Sun Blade X6275 Server Module? Mark for Review
(1) Points
2.0.2.9
2.0.1.0
2.0.3.13 (*)
3.0
Correct
104. Which of the following statements are Partner requirements for collaboration in the Multi-Vendor Support Program (MVSP)?
Mark for Review
(1) Points
(Choose all correct answers)
Partner must provide the Mutual Customer’s support identification number when collaborating with Oracle Support. (*)Partner must provide and maintain standard contact and escalation information for the MVSP. (*)Partner must establish their own severity levels and response timeframes for Mutual Customer support issues.Partner must direct Mutual Customers to contact Oracle Support directly on Oracle-related issues.
As part of the MVSP, Partners have the option of collaborating with Oracle Support on a Mutual Customer support issue.
Incorrect. Refer to the Multi-Vendor Support Program Overview training for more information.
111.
Which of the following is not normally provided via My Oracle Support
Mark for Review (1) Points
Certification information
Certified Advantage Partner Criteria (*)Access to SR logging
Diagnostic Tests
Incorrect, refer to the Oracle Support Basics training for more information
112. What can you expect following an escalation request? Mark for Review
(1) Points
24x7 working until problem resolved
Oracle Support manager telephones you to discuss your problem and agree to an action plan (*)Support Engineer passes SR to another engineerOracle Consultant onsite within 24 hours
Correct
113. Before raising an SR which of the following would you not need to do?
Mark for Review (1) Points
Run diagnostic tools
Set up an Oracle Collaborative Support session (*)Check My Oracle Support for any resolutions to similar issuesEnsure you understand the business impact
Incorrect, refer to the Oracle Support Basics training for more information
125.
The Main Community Home Page contains links to new member orientati
Mark for Review (1) Points
on resources, recorded trainings, FAQs, and a variety of other helpful resources for those of you just starting out in the communities.
False
True (*)
Incorrect. Refer to the My Oracle Support Community training for more information.