    Question

    What is Rockwell Automation's support policy for and what are some frequently asked questions about using Rockwell Automation Software with Windows XP mode in

    Windows 7?

    Environment

    Windows XP mode in Windows 7

    RSI software

    Node-Locked activations

    Concurrent activations

    The following pro ducts were tested and are now supported for us e with Windows XP Mode in Windows 7:

    FactoryTalk View Studio for FactoryTalk View Enterprise v6.00 (SR 3)

    FactoryTalk View Studio for Machine Edition v6.00 (SR 3)

    RSView32 Works v7.50

    FactoryTalk Activation Manager v3.30 (SR 3) (see issues listed below)

    FactoryTalk Services Platform (FTSP) v2.30 (SR 3) (see issues listed below)

    RSLinx Enterprise v5.30

    RSLinx Classic v2.57

    PanelBuilder32 v3.82

    The following product s will soon be tested:

    RSLogix5000 V19

    What is Windows XP Mode in Windows 7?

    Windows XP Mode in Windows 7 is a Windows XP Pro SP 3 Virtual Image that runs in the latest version of Microsofts Virtual PC software. This Windows XP Pro SP 3

    image uses the license with the Windows 7 host, and is a downloadable add-on for Windows 7 Professional, Ultimate, and Enterprise.

    Where can more information be found on Windows XP Mode in Windows 7?

    More information can be found on the Microsoft Windows XP Mode information site:

    http://windows.microsoft.com/en-US/windows7/products/features/windows-xp-mode

    Does Windows XP Mode comes standard with Windows 7?

    Windows XP Mode in Windows 7 is a downloadable add-on, it is not installed by default. The download link is the following:

    http://www.microsoft.com/windows/virtual-pc/download.aspx

    Why were Rockwell Automation products tested with Windows XP Mode in Windows 7?

    Some Rockwell Automation products, including older versions, do not yet support Windows 7 64-bit operating systems. The main goal of this testing was to provide an

    option for customers upgrading their engineering workstation / laptop to a Windows 7 64-bit Operating System. Windows XP Mode in Windows 7 should not be used in a

    production environment to host any run-time products; it should only be used with Rockwell Automation application development products like FactoryTalk View Studio,

    PanelBuilder32, and RSLogix5000.

    Are ther e any k now n issu es wi th Ro ckw ell A uto mati on So ftw are pr odu cts and Wind ows XP Mode in Wind ows 7?

    There are two issues related to the CPR9 SR3 release of the FactoryTalk Services Platform (FTSP). One issue is related to installing FTSP in the Windows XP Mode

    image, and the other issue is related to using Windows XP Mode Unity mode when running the image.

    Issue 1: The default Windows XP Mode settings will cause error messages from FTSP that the FactoryTalk Directory cannot be configured from a remote client when

    you try to perform the installation.

    To avoid this, select Disable Integration Features from the Windows XP Mode Tools menu before installing FTSP. To access the Tools menu make sure the XP mode is

    not in Full Screen. Once installation is complete, a user can use FTSP normally with Disable Integration Features still selected.

    Issue 2: Post installation, the use of Windows XP Mode Unity, or communications with the host PC, may be desired. Enable Integration Features must be selected for

    either of these two operations. Since it has been disabled as part of Issue 1 (above,) follow these steps to enable it once again.

    918 Support of Rockwell Automation Software in Windows XP ... https://rockwellautomation.custhelp.com/app/answers/detail/a_id/341918

    n 4 24.04.2014 20:54

  • 8/9/2019 Support of Rockwell Automation Software in Windows XP Mode in Windows 7

    2/4

    Launch FactoryTalk Administration Console from Start -> Programs -> Rockwell Software.1.

    Select Network Directory.2.

    Add the host PC computer name to the FactoryTalk Directory (FactoryTalk Directory -> System -> Computers and Groups -> Computers) or disable the "Require

    computer accounts for all client machines" setting in FactoryTalk Policies (FactoryTalk Directory -> System -> System Policies -> Security Policy)

    3.

    Once those changes are made, select Enable Integration Features from the Windows XP Mode Tools menu.

    Caution: If these steps are notperformedbefore selecting Enable Integration Features from the Windows XP Mode Tools menu,the FactoryTalk Directory will

    become locked out.

    4.

    The Factor yTalk Servi ces Platform (FTSP) v2.30 (SR 3) requires settin g changes (see abov e.) Will thes e be requir ed in future vers ions of t he FTSP?

    FTSP v2.40 is being modified to allow a remote client installation. This change will allow the user to skip the install related change described above.

    What is Unity Mode in Windo ws XP Mode?

    There are two modes in Windows XP Mode: Desktop Mode and Unity Mode.

    Desktop Mode involves running the XP Image in a separate window.

    Unity Mode involves running the programs in the XP Image as if they were installed on the host Windows 7 operating system. The programs are available under the

    Windows 7 Start Menu.

    918 Support of Rockwell Automation Software in Windows XP ... https://rockwellautomation.custhelp.com/app/answers/detail/a_id/341918

    n 4 24.04.2014 20:54

  • 8/9/2019 Support of Rockwell Automation Software in Windows XP Mode in Windows 7

    3/4

    Thus, in Unity mode, the program appears to run natively in Windows 7.

    How is thi s different than VMWare Workstation?

    With Windows XP Mode in Windows 7, Microsoft is providing a free copy of Windows XP Pro SP3 for use. While VMWare Workstation offers the user more ways to

    configure a Virtual Image, it has a separate license cost.

    How do I u se a USB Dongle with t he FactoryTalk Activ ation Manager in XP Mode?

    Installation and setup of the USB Dongle drivers for use in XP Mode is more involved than in native Windows 7 or Windows XP. Skip the installation of the HASP drivers

    when installing the Activation Manager, and refer to 67561 - 9509-USBDONG:Using a USB Dongle for activation in Windows 7 XP mode.

    Do Node-Locked activations work in XP Mode?

    No, Node-Locked activations will not work properly within XP Mode, because XP Mode is accessed through a terminal service within Windows 7, which is not supported

    for Node-Locked activations.

    918 Support of Rockwell Automation Software in Windows XP ... https://rockwellautomation.custhelp.com/app/answers/detail/a_id/341918

    n 4 24.04.2014 20:54

  • 8/9/2019 Support of Rockwell Automation Software in Windows XP Mode in Windows 7

    4/4

    Comments (0)

    This answer has no comments

    Post a Comment

    Product Tree for This Answer (expand/collapse)

    DISCLAIMER

    This knowledge base web site is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects.

    Accordingly, the information in this web site is not intended to constitute application, design, software or other professional engineering advice or services. Before making any

    decision or taking any action, which might affect your equipment, you should consult a qualified professional advisor.

    ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND

    MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO

    USERS "AS IS." IN NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL,

    LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES.

    ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT OF THE INFORMATION (INCLUDING SOFTWARE)

    PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that

    certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you.

    This page is best viewed in Internet Explorer 7, Firefox 3.5, Chrome 4, Safari 4 or newer.

    918 Support of Rockwell Automation Software in Windows XP ... https://rockwellautomation.custhelp.com/app/answers/detail/a_id/341918

    4 24 04 2014 20 54