SupremeSprinkler Pipes & Fittings

Presentation

The Supreme Industries Ltd

Page 2: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

SUPREMEHDPE Sprinkler Pipes and Fittings

Page 3: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Supreme Sprinkler………. Sprinkler system is a system where you can spray water through nozzles, at

rate which is less than absorption capacity of soil. This system and it joints consists of pipes and fittings made up of HDPE. Water use can be optimized to get maximum benefits out of it, by means of this system. Supreme HDPE pipes and fittings accessories are designed and developed by experts, to provide you the best quality .

SUPREME HDPE pipes and fittings are useful for all kinds of soils. It is useful where land is not leveled. By applying water through the sprinkler system, water can be saved ,soil erosion can be prevented / reduced, temperature of plant area can be maintained in summer. All the plants get uniform and regular water, so plant growth is uniform and fast. The crop gets ready earlier compared to others. Quality of crop remains uniform, and production is more. Thus you get better income and reduced cost.

Application : Suitable for almost all field crops like Wheat, Gram, Pulses as well as

Vegetables, Cotton, Soya bean, Tea, Coffee, and other fodder crops. Suitable for Residential, Industrial, Hotel, Resorts, Public & Government

Enterprises, Golf Links, Race courses. Salient Features : Portable , Chemically inert, Easy Handling, Quick installation, Corrosion

resistant, Flexible and tough, Low labour, Protection from ultra violet rays.

Page 4: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd
Page 5: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

DATA SHEET for Sprinkler Irrigation System: A. Raw Material Requirement Reference

  Designation (MRS) 6.3, 8.0 & 10 Mpa at 20ºC IS;14151(pt-1); 1999

  Melt Flow Rate (I5) 0.2 to 1.10 Gm/10 min. at 190º C IS;14151(pt-1); 1999

  Density 940.4 to 958.4 Kg/cm3 IS;14151(pt-1); 1999

B. Dimension As per table IS;14151(pt-1); 1999

 Length 3.0 to 6.0m or as agreed between manufacturer and

Purchaser.IS 14151 (pt-1): 1999

  Visual Appearance (Surface Finish) Satisfactory IS 14151 (pt-1): 1999

C. Performance Requirement    

  Heat Reversion Test Max 3% IS 14151 (pt-1): 1999

 

Hydrostatic Pressure Resistance Test

QUALITY TEST IS 14151 (pt-1): 1999

Duration: 165 hrs. at 80ºC, Stress Values : 3.5 Mpa

ACCEPTANCE TEST

Duration : 48 hrs at 80º C ,Stress Values: 3.8 Mpa

 

Fusion Compatibility Test QUALITY TEST IS 14151 (pt-1): 1999

Duration: 165 hrs at 80º C, Stress Values : 3.5 Mpa

ACCEPTANCE TEST

Duration : 48 hrs 80º C, Stress Values : 3.8 Mpa

  Melt Flow Rate (I5) 0.2 to 1.10 (both inclusive) Gm/10 min. IS 2530 : 1963

Page 6: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

DATA SHEET for Sprinkler Irrigation System:  Carbon Black Content & Dispersion 2.5 ± 0.5% IS 2530 : 1963

  Tensile Test 19 Mpa(T/S) 500%(Elongation) IS 14151 (pt-1): 1999

  Workmanship and Appearance Satisfactory IS 14151 (pt-2): 1999

  Bearing Capacity of Holding Attachment The holding attachment is strong enough to withstand the pressure two times the working pressure of pipe.

IS 14151 (pt-2): 1999

  Leakage Test without leakage IS 14151 (pt-2): 1999

  Hydraulic Proof Test The assembly shall not show any sign of localized swelling, leakage, weeping or deformation and shall not burst during the test.

IS 14151 (pt-2): 1999

  Weldability Test QUALITY TEST IS 14151 (pt-2): 1999

Duration: 165 hrs. at 80ºC Stress Values : 3.5Mpa

ACCEPTANCE TEST

Duration : 48 hrs at 80ºC Stress Values: 3.8 Mpa

 

D. Identification & Marking Colour: Black. All pipes shall be indelibly marked by hot foil embossing as per Colour code

IS 14151: 1999

Class-1-----Orange

Class-2------Red

Class-3------Blue

Class-4-------Green

Page 7: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Supreme Sprinkler pipes comply to IS 14151-Part I & Part II ,

Class 1( 0.25 Mpa ) - IS 14151 : 1999

Sr. No.

OD(mm) Avg(mm). Thickness(mm) Avg(mm).

Min Max OD Min Max Thickness

1 75.00 75.70 75.35 2.00 2.40 2.20

2 90.00 90.80 90.40 2.20 2.60 2.40

3 110.00 111.00 110.50 2.70 3.20 2.95

4 125.00 126.20 125.60 3.10 3.60 3.35

5 140.00 141.30 140.65 3.50 4.10 3.80

6 160.00 161.50 160.75 3.90 4.50 4.20

7 180.00 181.70 180.85 4.40 5.00 4.70

8 200.00 201.80 200.90 4.90 5.60 5.25

Page 8: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Supreme Sprinkler pipes comply to IS 14151 Part I & Part II :

Class 2( 0.32 Mpa ) - IS 14151 : 1999             

Sr. No.

OD(mm) Avg(mm). Thickness(mm) Avg(mm).

Min Max OD Min Max Thickness

1 63.00 63.60 63.30 2.00 2.40 2.20

2 75.00 75.70 75.35 2.50 2.90 2.70

3 90.00 90.80 90.40 2.90 3.40 3.15

4 110.00 111.00 110.50 3.40 3.90 3.65

5 125.00 126.20 125.60 3.80 4.50 4.15

6 140.00 141.30 140.65 4.30 5.00 4.65

7 160.00 161.50 160.75 4.90 5.60 5.25

8 180.00 181.70 180.85 5.50 6.30 5.90

9 200.00 201.80 200.90 6.10 7.00 6.55

Page 9: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Supreme Sprinkler pipes comply to IS 14151 Part I & Part II

Class 3( 0.4 Mpa ) - IS 14151 : 1999             

Sr. No.

OD(mm) Avg(mm). Thickness(mm) Avg(mm).

Min Max OD Min Max Thickness

1 50.00 50.50 50.25 2.00 2.40 2.20

2 63.00 63.60 63.30 2.50 2.90 2.70

3 75.00 75.70 75.35 3.00 3.40 3.20

4 90.00 90.80 90.40 3.50 4.10 3.80

5 110.00 111.00 110.50 4.20 4.80 4.50

6 125.00 126.20 125.60 4.80 5.50 5.15

7 140.00 141.30 140.65 5.40 6.10 5.75

8 160.00 161.50 160.75 6.20 7.00 6.60

9 180.00 181.70 180.85 6.90 7.80 7.35

10 200.00 201.80 200.90 7.70 8.70 8.20

Page 10: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Supreme Sprinkler pipes comply to IS 14151 Part I & Part II

Class 4( 0.6 Mpa ) - IS 14151 (Part 1) : 1999

             

Sr. No.

OD(mm) Avg(mm). Thickness(mm) Avg(mm).

Min Max OD Min Max Thickness

1 40.00 40.40 40.20 2.30 2.80 2.55

2 50.00 50.50 50.25 2.90 3.40 3.15

3 63.00 63.60 63.30 3.80 4.40 4.10

4 75.00 75.70 75.35 4.50 5.20 4.85

5 90.00 90.80 90.40 5.30 6.10 5.70

6 110.00 111.00 110.50 6.50 7.40 6.95

7 125.00 126.20 125.60 7.40 8.30 7.85

8 140.00 141.30 140.65 8.30 9.30 8.80

9 160.00 161.50 160.75 9.40 10.60 10.00

10 180.00 181.70 180.85 10.60 11.90 11.25

11 200.00 201.80 200.90 11.80 13.20 12.50

Page 11: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

Sprinkler Piping System Layout Design

Page 12: Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

THANK YOU………..

The Supreme Industries Limited