12
SY/Max to Quantum Quick Wiring Adapter (QWA) ank Prendergast dustrial Solution Center siness Development Manager for Services 8-975-9122 [email protected]

SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 [email protected]

Embed Size (px)

Citation preview

Page 1: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to QuantumQuick Wiring Adapter (QWA)Frank Prendergast Industrial Solution CenterBusiness Development Manager for [email protected]

Page 2: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWA

●What is the Quick Wiring Adapter

●Schneider Electric have designed a new Quantum I/O terminal block that SY/Max terminal blocks connect directly inside.

●This allows SY/Max I/O to be quickly converted to Quantum I/O without disturbing field wiring.

●Cost and Productivity benefits of migrating to Quantum

– SY/Max is 187% more expensive than Quantum to repair (on average)

– SY/Max is 89% more expensive than Quantum to exchange. (on average)

– Quantum Mean Time Between Failure values are 4 to 20 times greater than SY/Max!

– Quantum CPUs are 5 to 10x faster leading to greater productivity

Page 3: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

●What is the value proposition?●Utilize existing SY/Max field wiring and terminal blocks

– Less time and labor required to change– Reduce chance of wiring errors

●Minimizes conversion time per drop – MINIMIZE PLANT DOWNTIME (associated with the upgrade)– Rewire = 5 to 6 hours per drop QWA = 1 hour per drop

●No wire is removed and circuit board in QWA is validated to be correct.

●Minimizes your overall RISK of change !

●Minimize your cost and equipment downtime with less expensive more robust Quantum hardware.

SY/Max to Quantum QWA

Page 4: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWA

●How it is ordered.●Please call 1-800-468-5342 extension 1 and ask for Field Services.

●and

●Email a list of all of the SY/Max modules that you want to replace in an email to [email protected]

●We will send you a quotation for the new Quantum modules, Quick Wiring Adapters, and SY/Max adapter plates you need.

●April 20th first customer order

●Lead time is 4 weeks

Current Symax Modules supported

8030-HIM-101 8030-HOM-222

8030-HIM-102 8030-HOM-232

8030-HIM-131 8030-RIM-121

8030-HIM-141 8030-ROM-121

8030-HIM-151 8030-RIM-101

8030-HIM-161 8030-RIM-361

8030-HOM-211 8030-ROM-221/222

8030-HOM-221 8030-ROM-431

8030-HOM-231 RIM125

8030-HOM-241 ROM271

8030-HOM-251 RIM731

8030-HOM-261 ROM871

8030-HOM-271  

Page 5: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

●FAQs.● Q. Is the new QWA any deeper or longer than my SY/Max system?● A. Yes. The QWA is ½ inch longer and deeper.

● Q. How do I know what this QWA does electronically?● A. The QWA connects wire to wire. Each QWA has a unique part number on it that

identifies which SY/Max module and Quantum module it is designed for. For example a HIM101DAI5400 states that it is a SY/Max 8030HIM101 module connected to a Quantum 140DAI5400 module. In addition a wiring diagram is included with each QWA.

● Q. Are there any limitations to using the QWA?● A. The QWA was designed to handle the same worst case electrical conditions as the

SY/Max module would encounter.

● Q. Do I have to worry about electrical live wires?● A. The QWA has a cover (same as standard Quantum terminal block) so it offers the

same safety as long as the cover is closed.

SY/Max to Quantum QWA

Page 6: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 1

Observe allsafety rules and turnoff all power sourcesgoing to the rack andI/O modules !

Remove all electricalpower from the rackand all non I/O modules

Page 7: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 2

Remove all I/O Terminal blocks from I/O modules

Page 8: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 3

Remove all I/Omodules from therack

Remove the SY/Maxrack

Page 9: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 4

Install the SY/Max to QuantumAdapter plate kit

This allows you to install the Quantumbackplane without having to drill into the enclosure sub-panel.

Page 10: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 5

Install the QuantumI/O modules in thesame location asprevious SY/Max I/O module.

Page 11: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 6

Install theSY/Max to QuantumQuick Wiring Adapterterminal block intothe Quantum I/OModule.

Open the coverTo the Quick WiringAdapter.

Page 12: SY/Max to Quantum Quick Wiring Adapter (QWA) Frank Prendergast Industrial Solution Center Business Development Manager for Services 978-975-9122 frank.prendergast@us.schneider-electric.com

SY/Max to Quantum QWAInstallation Step 7

Insert the SY/Maxterminal block intothe SY/Max to QuantumQWA

Close the cover.

You are now readyto startup your systemknowing that the wiringfrom your older SY/Maxsystem is now beingused in your QuantumSystem !