SY/Max to QuantumQuick Wiring Adapter (QWA)Frank Prendergast Industrial Solution CenterBusiness Development Manager for [email protected]
SY/Max to Quantum QWA
●What is the Quick Wiring Adapter
●Schneider Electric have designed a new Quantum I/O terminal block that SY/Max terminal blocks connect directly inside.
●This allows SY/Max I/O to be quickly converted to Quantum I/O without disturbing field wiring.
●Cost and Productivity benefits of migrating to Quantum
– SY/Max is 187% more expensive than Quantum to repair (on average)
– SY/Max is 89% more expensive than Quantum to exchange. (on average)
– Quantum Mean Time Between Failure values are 4 to 20 times greater than SY/Max!
– Quantum CPUs are 5 to 10x faster leading to greater productivity
●What is the value proposition?●Utilize existing SY/Max field wiring and terminal blocks
– Less time and labor required to change– Reduce chance of wiring errors
●Minimizes conversion time per drop – MINIMIZE PLANT DOWNTIME (associated with the upgrade)– Rewire = 5 to 6 hours per drop QWA = 1 hour per drop
●No wire is removed and circuit board in QWA is validated to be correct.
●Minimizes your overall RISK of change !
●Minimize your cost and equipment downtime with less expensive more robust Quantum hardware.
SY/Max to Quantum QWA
SY/Max to Quantum QWA
●How it is ordered.●Please call 1-800-468-5342 extension 1 and ask for Field Services.
●and
●Email a list of all of the SY/Max modules that you want to replace in an email to [email protected]
●We will send you a quotation for the new Quantum modules, Quick Wiring Adapters, and SY/Max adapter plates you need.
●April 20th first customer order
●Lead time is 4 weeks
Current Symax Modules supported
8030-HIM-101 8030-HOM-222
8030-HIM-102 8030-HOM-232
8030-HIM-131 8030-RIM-121
8030-HIM-141 8030-ROM-121
8030-HIM-151 8030-RIM-101
8030-HIM-161 8030-RIM-361
8030-HOM-211 8030-ROM-221/222
8030-HOM-221 8030-ROM-431
8030-HOM-231 RIM125
8030-HOM-241 ROM271
8030-HOM-251 RIM731
8030-HOM-261 ROM871
8030-HOM-271
●FAQs.● Q. Is the new QWA any deeper or longer than my SY/Max system?● A. Yes. The QWA is ½ inch longer and deeper.
● Q. How do I know what this QWA does electronically?● A. The QWA connects wire to wire. Each QWA has a unique part number on it that
identifies which SY/Max module and Quantum module it is designed for. For example a HIM101DAI5400 states that it is a SY/Max 8030HIM101 module connected to a Quantum 140DAI5400 module. In addition a wiring diagram is included with each QWA.
● Q. Are there any limitations to using the QWA?● A. The QWA was designed to handle the same worst case electrical conditions as the
SY/Max module would encounter.
● Q. Do I have to worry about electrical live wires?● A. The QWA has a cover (same as standard Quantum terminal block) so it offers the
same safety as long as the cover is closed.
SY/Max to Quantum QWA
SY/Max to Quantum QWAInstallation Step 1
Observe allsafety rules and turnoff all power sourcesgoing to the rack andI/O modules !
Remove all electricalpower from the rackand all non I/O modules
SY/Max to Quantum QWAInstallation Step 2
Remove all I/O Terminal blocks from I/O modules
SY/Max to Quantum QWAInstallation Step 3
Remove all I/Omodules from therack
Remove the SY/Maxrack
SY/Max to Quantum QWAInstallation Step 4
Install the SY/Max to QuantumAdapter plate kit
This allows you to install the Quantumbackplane without having to drill into the enclosure sub-panel.
SY/Max to Quantum QWAInstallation Step 5
Install the QuantumI/O modules in thesame location asprevious SY/Max I/O module.
SY/Max to Quantum QWAInstallation Step 6
Install theSY/Max to QuantumQuick Wiring Adapterterminal block intothe Quantum I/OModule.
Open the coverTo the Quick WiringAdapter.
SY/Max to Quantum QWAInstallation Step 7
Insert the SY/Maxterminal block intothe SY/Max to QuantumQWA
Close the cover.
You are now readyto startup your systemknowing that the wiringfrom your older SY/Maxsystem is now beingused in your QuantumSystem !