1
Petrolux ® III Thermal Performance Data Family Source 1598 Ambient (°C) 844 Ambient (°C) Supply Wire (°C) Class I Div 2 Class II Div 1 Class III Simultaneous Presence Class I Div 2 Class II Div 1 Class I Zone 2 Watt Type PD/WL CE PD/WL CE Groups T Rating Groups T Rating nA nR P3S 42 CFL 55 55 55 55 90 A, B, C, D T3 E, F, G T4 T1 T6 50 HPS 60** 55** 55* 55 90 A, B, C, D T3 E, F, G T4A T1 T6 50 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T4 T1 T5 55 QL 45 45 40 40 90 A, B, C, D T3C E, F, G T4A T1 70 HPS 60** 55** 55* 55 90 A, B, C, D T2C E, F, G T4A T2C T4 70 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T5 T2B T4 100 HPS 60** 55** 55* 55 90 A, B, C, D T2A E, F, G T4A T2B T4 100 MH 55 55 55 55 90 A, B, C, D T2B E, F, G T4 T1 T4 150 HPS 60** 50 55* 40 90 A, B, C, D 325 E, F, G T4 T2 T4 150 MH 55 5055 40 90 A, B, C, D 350 (325 for CE) E, F, G T4 350 (325 for CE) T4 150 MHE 40 40 40 40 90 A, B, C, D T1 E, F, G T4 T1 T5 P3M 42 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T6 55 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A 57 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T6 50 HPS 55 55 55 55 90 A, B, C, D T3C E, F, G T4 T2A T5 70 HPS 55 55 55 55 90 A, B, C, D T3A E, F, G T5 T3A T4 70 MH 55 55 55 55 90 A, B, C, D T2C E, F, G T4 T2A T4 70 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T6 85 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A 100 HPS 55 55 55 55 90 A, B, C, D T2D E, F, G T4A T3 T3 100 MH 55 55 55 55 90 A, B, C, D T2A E, F, G T4A T2B T3 150 HPS 55 55 55 55 90 A, B, C, D T2B E, F, G T4A T2B T3 150 MH 55 55 55 55 90 A, B, C, D 350 E, F, G T4 T2A T4 150 MHE 40 40 40 40 90 A, B, C, D 325 E, F, G T4 T2 T4 175 PMH 55 55 55 55 90 A, B, C, D T2A E, F, G T4 T2A T4 * UL844 Ambient Temperature is 40°C when fusing is ordered as an option ** UL1598 Ambient Temperature is 50°C when fusing is ordered as an option UL1598 Ambient Temperature is 45°C when fusing is ordered as an option

T-Code Rating Charts:Layout 1 - Acuity Brands Brochu… · Petrolux ® III Thermal Performance Data Family Source 1598 Ambient (°C) 844 Ambient (°C) Supply Wire (°C) Class I Div

Embed Size (px)

Citation preview

Page 1: T-Code Rating Charts:Layout 1 - Acuity Brands Brochu… · Petrolux ® III Thermal Performance Data Family Source 1598 Ambient (°C) 844 Ambient (°C) Supply Wire (°C) Class I Div

Petrolux® III

Thermal Performance Data

Family Source1598 Ambient

(°C)844 Ambient

(°C)

SupplyWire(°C)

Class I Div 2 Class II Div 1

Class III

SimultaneousPresence

Class I Div 2Class II Div 1

Class IZone 2

Watt Type PD/WL CE PD/WL CE Groups T Rating Groups T Rating nA nR

P3S

42 CFL 55 55 55 55 90 A, B, C, D T3 E, F, G T4 T1 T650 HPS 60** 55** 55* 55 90 A, B, C, D T3 E, F, G T4A T1 T650 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T4 T1 T555 QL 45 45 40 40 90 A, B, C, D T3C E, F, G T4A T1 —70 HPS 60** 55** 55* 55 90 A, B, C, D T2C E, F, G T4A T2C T470 MH 55 55 55 55 90 A, B, C, D T2D E, F, G T5 T2B T4100 HPS 60** 55** 55* 55 90 A, B, C, D T2A E, F, G T4A T2B T4100 MH 55 55 55 55 90 A, B, C, D T2B E, F, G T4 T1 T4150 HPS 60** 50† 55* 40 90 A, B, C, D 325 E, F, G T4 T2 T4150 MH 55 50† 55 40 90 A, B, C, D 350 (325 for CE) E, F, G T4 350 (325 for CE) T4150 MHE 40 40 40 40 90 A, B, C, D T1 E, F, G T4 T1 T5

P3M

42 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T655 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A —57 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T650 HPS 55 55 55 55 90 A, B, C, D T3C E, F, G T4 T2A T570 HPS 55 55 55 55 90 A, B, C, D T3A E, F, G T5 T3A T470 MH 55 55 55 55 90 A, B, C, D T2C E, F, G T4 T2A T470 CFL 55 55 55 55 90 A, B, C, D T3B E, F, G T4 T2A T685 QL 40 40 40 40 90 A, B, C, D T3C E, F, G T4 T2A —100 HPS 55 55 55 55 90 A, B, C, D T2D E, F, G T4A T3 T3100 MH 55 55 55 55 90 A, B, C, D T2A E, F, G T4A T2B T3150 HPS 55 55 55 55 90 A, B, C, D T2B E, F, G T4A T2B T3150 MH 55 55 55 55 90 A, B, C, D 350 E, F, G T4 T2A T4150 MHE 40 40 40 40 90 A, B, C, D 325 E, F, G T4 T2 T4175 PMH 55 55 55 55 90 A, B, C, D T2A E, F, G T4 T2A T4

* UL844 Ambient Temperature is 40°C when fusing is ordered as an option** UL1598 Ambient Temperature is 50°C when fusing is ordered as an option† UL1598 Ambient Temperature is 45°C when fusing is ordered as an option