1Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
MODELS:NATURAL GAS PROPANECFL-18NG-C CFL-18LP-CCFL-24NG-C CFL-24LP-CCFL-30NG-C CFL-30LP-CCFL-24NG-IPI CFL-24LP-IPI
• Donotstoreorusegasolineorotherflam-mablevaporsand liquids in thevicinityofthisoranyotherappliance.
• What to do if you smell gas - Donottrytolightanyappliance.- Donottouchanyelectricalswitch.Donotuseanyphoneinyourbuilding.
- Immediatelycallyourgassupplierfromaneighbor’sphone.Followthegassuppli-er’sinstructions.
- Ifyoucannotreachyourgassupplier,callthefiredepartment.
• Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagency,orthegassupplier.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
Owner’s ManualInstallation and Operation
DO NOT DISCARD THIS MANUALCAUTION
• Leave thismanualwithpartyresponsibleforuseandoperation.
DO NOTDISCARD• Important operating
and maintenanceinstructionsincluded.
• Read,understandandfollowtheseinstructionsforsafeinstallationandoperation.
IntheCommonwealthofMassachusetts:• Installationmustbeperformedbyalicensedplumberorgasfitter.
• Thechimneyfluedamper,whenusedwithgaslogs,willbeweldedopenorcompletelyremoved.
• ACOdetectorshallbeinstalledintheroomwheretheapplianceisinstalled.
WARNINGHOT SURFACES! GlassandothersurfacesarehotduringoperationANDcooldown.Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway
• CAREFULLY SUPERVISE children in same room asfireplace.
• Alertchildrenandadultstohazardsofhightemperatures.High temperatures may ignite clothing or other flammable materials.• Keep clothing, furniture, draperies and other flammablematerialsaway.
Installation and service of thisapplianceshouldbeperformedbyqualifiedpersonnel.Hearth&HomeTechnologiesrecommendsNFIcertifiedprofessionals.
WARNING: Thisproductand the fuelsused tooperate this product (liquid propane or natural
gas),andtheproductsofcombustionofsuchfuels,canexpose you to chemicals including benzene,which isknown to theStateofCalifornia to causecancerandreproductiveharm. Formore informationgoto:www.P65Warnings.ca.gov.
Note: Theuseofathermostatisprohibitedinventedloginstallations.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/212
Congratulations
Listing Label Information/Location
ModelName: ___________________________________________ Datepurchased/installed: __________________
SerialNumber: __________________________________________ Locationonappliance: ____________________
Dealershippurchasedfrom: _______________________________ DealerPhone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Readthismanualbeforeinstallingoroperatingthisappliance.Pleaseretainthisowner’smanualforfuturereference.
We recommend that you record the following pertinent information about your appliance.
GasInformation
SerialNumber
TypeofGas
Themodelinformationregardingyourspecificappliancecanbefoundontheratingplateusuallylocatedinthecontrolareaoftheappliance.
Homeowner Reference Information
ModelNumber
for Not Not for use use with with solid solid fuel.fuel.((Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solide).solide).
This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes, codes, if if any; any; if if not, not, follow follow ANSI ANSI Z223.1Z223.1in in the the USA USA or or CAN/CGA CAN/CGA B149 B149 installation installation codes. codes. (Installer (Installer l’appareil l’appareil selon selon les les codes codes ou ou reglementsreglementslocaux locaux ou, ou, en en l’absence l’absence de de tels tels reglements, reglements, selon selon les les codes codes d’installation d’installation CAN/CGA-B149.)CAN/CGA-B149.)
Type Type of of Gas Gas (Sorte (Sorte De De Gaz)Gaz)::
NNAATURALTURAL GASGAS
MADE MADE IN IN USAUSA
Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment.Adjustment.Approved Approved Minimum Minimum (De (De Gaz) Gaz) AcceptableAcceptable 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)Maximum Maximum Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)Maximum Maximum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)Minimum Minimum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. d’eau)d’eau)
Model:Model:(Modele):(Modele):
SerialSerial(Serie):(Serie):
ANSI ANSI Z21XX-XXXX Z21XX-XXXX · · CSA CSA 2.XX-MXX 2.XX-MXX · · UL307BUL307B
XXXXXXXXXXXXXXXXIN IN CANADACANADA
ALTITUDE:ALTITUDE: 0-0000 0-0000 FT.FT. 0000-0000FT.0000-0000FT.MAX. MAX. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000MIN. MIN. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000ORIFICE ORIFICE SIZE:SIZE: #XXXXX#XXXXX #XXXXX#XXXXX XXXXXXXXXXXXXXXX
Total Total Electrical Electrical Requirements: Requirements: 000Vac, 000Vac, 00Hz., 00Hz., less less than than 00 00 AmperesAmperes
Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044
CongratulationsonselectingaHearth&HomeTechnologiesgasfireplace,anelegantandcleanalternative towoodburningfireplaces.Thegasfireplaceyouhaveselectedisdesignedtoprovidetheutmostinsafety,reliability,andefficiency.Astheownerofanewfireplace,you’llwanttoreadandcarefully follow all of the instructions contained in thisowner’smanual.Payspecialattentiontoallcautionsandwarnings.
This owner’s manual should be retained for futurereference.Wesuggest that you keep itwith yourotherimportantdocumentsandproductmanuals.Theinformationcontainedinthisowner’smanual,unlessnotedotherwise, applies to allmodels andgas controlsystems.YournewHearth&HomeTechnologiesgasfireplacewillgiveyouyearsofdurableuseandtrouble-freeenjoyment.Welcome to theHearth&HomeTechnologies familyoffireplaceproducts!
3Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
=Containsupdatedinformation.
Table of Contents
1 Introduction A. ApplianceCertification. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. BTUSpecifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6C. HighAltitudeInstallation. . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Getting Started A. InspectApplianceandComponents. . . . . . . . . . . . . . . . . . 7B. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Operating Guidelines and Maintenance Instructions A. BeforeLightingAppliance......................... 10B. Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Troubleshooting A. StandingPilotIgnitionSystem. . . . . . . . . . . . . . . . . . . . . 13B. IntelliFire®IgnitionSystem. . . . . . . . . . . . . . . . . . . . . . . . 15
5 Reference Materials A. ServiceParts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17B. LimitedLifetimeWarranty. . . . . . . . . . . . . . . . . . . . . . . . . 22C.ContactInformation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/214
Thislogsetistobeinstalledonlyinasolid-fuelburningfireplacewithaworkingflueandoneconstructedofnon-combustiblematerial.Theminimumpermanentventopen-ingprovidedbythefireplacechimneydampertoventtheflueproductsmustnotbelessthan51squareinches(328cm2).ThechimneydamperMUSTbefixedinamannertomaintaintheminimumpermanentventopening.Thismaybeaccomplishedbyfasteningthedamperstopclamppro-videdtotheedgeofthedampertopreventitsclosing.Theinstallation,includingprovisionsforcombustionandventilationair,mustconformwiththeNationalFuelGasCodeANSIZ223.1(intheUnitedStates),theCAN/CGAB-149InstallationCode(inCanada)andapplicablelocalbuildingcodes.Thesemodelscanbeinstalledinabedroom(intheUnitedStates)whichhasatotalvolumeofunconfinedspaceap-propriatetotheparticularinstallation.RefertotheNationalFuelGasCodeANSIZ223.1/NFPA54-(currentedition).TheUniformMechanicalCode(currentedition),andLocalBuildingOfficialsfortheoptionsallowedinobtaininganeffectivebedroomvolumeofunconfinedspace.Alwayskeeptheapplianceareaclearandfreefromcom-bustiblematerials,gasoline,andotherflammablevaporsandliquids.WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
A. Appliance Certification
WARNINGFireRiskAsphyxiationRisk
ThesegaslogsetshavebeentestedandlistedintheU.S.inaccordancewithANSI Z21.60b-2004.TheyhavebeenlistedbyUnderwritersLaboratoriesInc.forinstallationandoperationintheUnitedStatesandCanadaasdescribedintheseInstallationandOperationInstructions.Allcompo-nentsareUL,AGA,CGAorCSAsafetycertified.Checkwithyourlocalbuildingcodeagencypriortoinstall-ingthisappliancetoensurecompliancewithlocalcodes,includingtheneedforpermitsandfollow-upinspections.Intheabsenceoflocalcodes,complywiththeNationalFuelGasCode,ANSIZ223.1-LatestEditionintheU.S.Ifanyassistanceisrequiredduringinstallation,pleasecontactyourlocaldealer.
CAUTIONChecktheconstructionofthefireplacebeforeinstallingthegaslogset.Theareaoftheflueshouldnotbelessthan1/11theareaofthefireplaceopening.Non-airtightglassdoorsshouldbe installedon thefireplace if theareaof theflueislessthan1/11theareaofthefireplaceopening.Airtightdoorsmustneverbeusedwiththisgaslogset.
FireRisk• THISUNITISNOTFORUSEWITHSOLIDFUEL. Solid fuels shall not be burned in afireplace where a decorative appliance isinstalled.Failuretofollowtheseinstructionswillresultinafire.
WARNING
1 1 Introduction
GasLogSetsareDecorativeGasAppliancesforInstalla-tioninaSolid-fuelBurningFireplace.MinimumfireplacesizesforthesemodelsisshowninFigure1.
MODELS: CFL-18NG/LP-C, CFL-24NG/LP-C, CFL-30NG/LP-C, CFL-24NG/LP-IPILABORATORY: Underwriters Laboratories, Inc. (UL)TYPE: Decorative Gas Appliances for Installation in
Solid-Fuel Burning FireplacesSTANDARD: ANSI Z21.60b-2004 CSA 2.26b-2004
• This log set must NOT be installed in an unventedappliance.
• Openthechimneydampertoitsfullyopenpositionwhenburningthisgaslogset.
• Logsmustneverbeburnedwithoutthefluedamperinthefullopenposition. Failure todoso isdangerous toyourhealthandvoidsallwarranties.
• Allgasappliancesproducesomecarbonmonoxidewhenoperated. Carbonmonoxide is a colorless, odorless,poisonous gas. Adequate provisionsmust bemade toprovidecombustionairforthisgaslogset.Ifoutsideairisnotaccessedbythefireplace,itmaybenecessarythatanadditionalcombustionairsourcebeprovided.
5Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
MODEL CFL-18-C
MINIMUMFIREPLACESIZE FRONTWIDTH:231/2”(750mm) REARWIDTH:191/2”(521mm) DEPTH :131/2”(331mm) HEIGHT :22”(508mm)
23 1/2
MODEL CFL-24-C
TOPVIEW
MINIMUMFIREPLACESIZE FRONTWIDTH:271/2”(750mm) REARWIDTH:22”(521mm) DEPTH :151/2”(331mm) HEIGHT :22”(508mm)
151/2
27 1/2
22
TOPVIEW13 1/2
19 1/2
TOPVIEW
MINIMUMFIREPLACESIZE FRONTWIDTH:30”(750mm) REARWIDTH:24”(521mm) DEPTH :151/2”(331mm) HEIGHT :22”(508mm)
151/2
30
24
MODEL CFL-30-C
Figure1.MinimumFireplaceSizesforCFL-18/24/30-C
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/216
C. High Altitude InstallationNOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.Wheninstallingabove2000feetelevation:• In theUSA:Reduce inputrate4%foreach1000feetabove2000feet.
• In CANADA:Reduce input rate 10% for elevationsbetween2000 feet and4500 feet.Above4500 feet,consultlocalgasutility.
Checkwithyourlocalgasutilitytodetermineproperorificesize.
B. BTU Specifications
Models(U.S. or Canada) Input BTU/h
OrificeSize (DMS)
CFL-18NG-CCFL-24NG-CCFL-30NG-CCFL-24NG-IPI
US(0-2000 FT) 60,000 7-1.55mm
CANADA(2000-4500 FT) 54,000 #25DMS
CFL-18LP-CCFL-24LP-CCFL-30LP-CCFL-24LP-IPI
US(0-2000 FT) 60,000 2.30mm
CANADA(2000-4500 FT) 54,000 #43DMS
7Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
Thesemodelscontaincompletegas-burner,grate(s),andlogcomponentsneeded.Usecautionwhenhandlinglogs toavoiddamage.Positionthegas-burnerassemblytotherearofthefireplace.Oncefullyassembled,thefrontlogwillextendforwardoftheburnerassembly.
2 2 Getting Started
Note:Thegassupplylineshouldbepurgedofanytrappedairpriortothefirstfiringoftheunit.
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
CAUTION! When installing this log set in a factory built fireplace, be certain to consult the fireplace installation manual. ALL knockouts in the fireplace through which the gas supply line is run MUST be resealed with insulation after the gas line is in place.
WARNING! Risk of Asphyxiation! Improper positioning of log set may allow spillage and prohibit proper draft. • Position the log set as close to the back of the fireplace as
possible.
A. Inspect Appliance and Components• Carefullyremovetheapplianceandcomponentsfromthepackaging.
• Ifpackagedseparately,thelogsetandappliancegratemustbeinstalled.
• Reporttoyourdealeranypartsdamagedinshipment,particularlytheconditionoftheglass.
• Read all of the instructions before starting the instal-lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.
WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in-complete or substitute components. Keep appliance dry.
Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:• Installationanduseofanydamagedapplianceor ventsystemcomponent.
• Modificationoftheapplianceorventsystem.• Installationother thanas instructedbyHearth&HomeTechnologies.
• Improperpositioningofthegaslogsortheglassdoor.• Installationand/oruseofanycomponentpartnotapprovedbyHearth&HomeTechnologies.
Any such action may cause a fire hazard.
B. Installation1. GAS CONNECTIONa.Runpropersizegaslineintofireplace.A1/2inch(13mm)
gasline,witha3/8inch(10mm)reductionforhook-up,isusuallysufficientfortheGasLogset;however,iftherunisunusuallylong,alargerlinemayberequired.ContactyourlocalgascompanyorDepartmentofBuildingandSafetyifthereareanyquestions.
b.Optimumapplianceperformancerequiresproperinputpressures.Pressurerequirementsare:
Gas Pressure Natural Gas PropaneMinimuminletpressure 5.0in.w.c. 11.0in.w.c.Maximuminletpressure 10.0in.w.c. 13.0in.w.c.Manifoldpressure 3.5in.w.c. 10.0in.w.c.
c.Theapplianceanditsindividualshutoffvalvemustbedisconnectedfromthegassupplypipingsystemduringanypressuretestingofthesystemattestpressuresinexcessof1/2psig.
d.Thisappliancemustbe isolated from thegassupplypipingsystembyclosingitsindividualmanualshutoffvalveduringanypressure testingof the gas supplypipingsystemattestpressuresequaltoorlessthan1/2psig.
WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion.• Verifyinletpressures.Verifyminimumpressureswhenotherhouseholdgasappliancesareoperating.
• Install regulator upstreamof valve if line pressure isgreaterthan1/2psig.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/218
Figure 1.
DAMPER CLAMP
OPEN DAMPER
WARNING! Risk of Fire! • Open the chimney damper to its FULLY OPEN posi-
tion when burning this gas log set.• DO NOT burn Logs without the flue damper in the
FULL OPEN position. Failure to do so is dangerous to your health and voids all warranties.
Note:TheCommonwealthofMassachusettsrequires thatthechimneyfluedamper,whenusedwithgaslogs,shallbeweldedopenorcompletelyremoved.
Figure 2. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI
2. ELECTRICAL INSTALLATION• Thisappliancemaybeusedwithawallswitchand/or
remotecontrol.• Uselowresistancethermostatwireforwiringfromigni-
tionsystemtothewallswitch.• Keepwirelengthsasshortaspossiblebyremovingany
excesswirelength.• Lowvoltageand110VACvoltagecannotbeshared
withinthesamewallbox.
BLACK
RED
BATTERY PACK(BATTERIES REQUIRED)
WIRES(TO BROWN)
OR
AN
GE
GR
EEN
VALVE
GROUND TOFIREPLACE
CHASSIS
WHITE
ORANGE
IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR
I
S
REMOTE OR WALL SWITCH
e.Adamperstopclampwithsetscrewisprovidedtopre-ventfullclosureofthefireplacedamperblade.Attachtheclamptotheedgeofthedamperbladewithpliersorwrenches.Ifthedamperstopsupplieddoesnotfittheapplication,useapermanentmeansthatwillkeepthedamperopentoaMINIMUMof51squareinches(328cm2).SeeFigure1.
REMOTE OR WALL SWITCH
BLACK BLACK
ON/OFFSWITCH
RED
THERMOPILE
WHITE
Figure 3. Standing Pilot Wiring Diagram
f. TestfiretheunitafterreferringtotheSAFETY INFOR-MATION and LIGHTING INSTRUCTIONS found inSection3inthismanual,oronthelabelplateassemblyfoundonthegas-burner.
g.Afterthegaslineinstallationiscomplete,allconnectionsmustbetightenedandcheckedforleakswithacom-mercially-available,non-corrosiveleakchecksolution.Be sure to rinseoffall leak check solution followingtesting.RefertoSection3,OPERATING GUIDELINES and MAINTENANCE INSTRUCTIONS.
h.Oncethegas-burneristestfiredandgassupplylinesarepurged,assemblethegrate(s)andlogs.BecertaintofollowtheLogPlacementInstructionsshippedwiththeunit.RemembertokeeptheLogInstructionsalongwiththismanualforfutureuse.
9Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
4. REMOTE CONTROL• Ifaremotecontrolisused,thereceivercannotbeplacedundertheburner.Ifpossible,placethereceiveroutsidethecombustionchamber.
• Ifthereceivermustbeplacedinthecombustionchamber,theprotectiveheatshieldMUSTbeused.SeeFigure4.
• Positionreceiveronleftsideofgaslogset(oppositethepilot).Placeprotectiveheat shield over receiver.SeeFigure5.
Figure 4. Protective Heat Shield
Figure 5. Receiver Location-Left Side of Log Set
RECEIVERRECEIVER
3. AIR SHUTTER SETTINGS.Thisappliancehasanadjustableairshutter(whichcon-trolstheprimaryair)factorysetfortheminimumverticalventrun.Ifyourinstallationhasmorethantheminimumrequiredverticalventlength,adjustmentoftheairshuttermaybenecessary toobtainoptimalflameappearance.This should be adjusted by a qualified installer at the time of installation.
Air Shutter Settings
NG PropaneBurner 3/8in. FullOpen
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2110
3 3 Operating Guidelines and Maintenance Instructions
Fire RiskBesurefireplacescreenorglassdoorsare inplacewhenburningfireplacelogs.Unlessotherprovisions forcombustionairareprovided, thescreenordoorsshallhaveanopeningforintro-ductionofcombustionair.THISGASLOGSETISNOTDESIGNEDTOOPERATEWITHAIRTIGHTGLASSDOORS.Adequatecombustionandcoolingairmustbeprovidedortheunitwillnotfunctionproperly.
WARNING
Fire RiskExplosion RiskWARNING:Toavoidpossibleinjury,fireandexplosion,please readand follow thesepre-cautionsandallinstructionsonthisappliancebeforelightingthepilot.Beforelighting,smellatfloorleveland/oruseothermeans(suchasusingacommercially-available,non-corrosiveleakchecksolutiononallpipingandconnec-tions,usingagasdetector,etc.)tocheckforgasleaks.NOTE:L.P.(Propane)gascanbecomeodorless andCANNOTalways be detectedbysmell.
WARNING
B. MaintenancePeriodicallyremovethelogsandexaminetheburner.Ifdirty,cleanwithasoftbrush.Alsoexaminetheareaaroundtheburnerairshutterandthepilot.Anydirtorlintinthisarea should be removed.Thiswill ensure long life andtrouble-freeoperation.Theapplianceandventingsystemshouldbe inspectedbeforeinitialuseandinspectedandcleanedatleastan-nuallybyaqualifiedfieldserviceperson.
A. Before Lighting ApplianceBeforelightingthisappliancedetermineifithasaStandingPilotor IntelliFire® ignitionsystembyviewing thewiringsystemandgasvalve.Ifthisappliancehasaredorblackignitorbutton(seeFigure3andFigure4)thisappliancehasaStandingPilotignitionsystem.Ifthereisnoredorblackignitorbutton,thisappliancehasanIntelliFireignitionsystem.
Before operating this appliance have a qualified tech-nician:• Removeallshippingmaterials.• Reviewproper placement of logs, rockwool, and ver-miculite.
• Checkthewiring.• Ensurethattherearenogasleaks.Uponcompletingthegaslineconnection,asmallamountofairwillbeinthelines.Whenfirstlightingthepilotlight,itwilltakeafewminutesforthelinestopurgethemselvesof thisair. Once thepurging iscomplete, thepilotandburnerwill lightandoperateas indicated in the instruc-tionmanual.Subsequentlightingoftheappliancewillnotrequiresuchpurging.
WARNINGHOT SURFACES! GlassandothersurfacesarehotduringoperationANDcooldown.Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway
• CAREFULLYSUPERVISE children in same room asfireplace.
• Alertchildrenandadultstohazardsofhightemperatures.High temperatures may ignite clothing or other flammable materials.• Keepclothing,furniture,draperiesandotherflammablematerialsaway.
WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
Improper installation, adjustment, alteration, service ormaintenance can cause injury or property damage. Forassistance or additional information, consult a qualifiedservicetechnician,serviceagencyoryourdealer.
11Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
Lighting Instructions (IPI)TheIPIsystemmustbeoperatedwithtwoD-cellbatteries.
1. This appliance is equipped with an ignitiondevicewhichautomaticallylightstheburner.DO NOTtrytolighttheburnerbyhand.
2. Wait five (5) minutes to clear out any gas.Thensmellforgas,includingnearthefloor.Ifyousmellgas,STOP!Follow“B”intheSafetyInformationlocatedontheleftsideofthisla-bel.Ifyoudonotsmellgas,gotonextstep.
3. Tolighttheburner: Equippedwithwallswitch:TurnON/OFFswitch
toON. Equippedwithremoteorwallcontrol:Press
ONorFLAMEbutton. Equippedwiththermostat:Settemperatureto
desiredsetting.4. Iftheappliancedoesnotlightafterthreetries,
callyourservicetechnicianorgassupplier.
LIGHTINGINSTRUCTIONS (IPI)
TO TURN OFFGAS TO APPLIANCE
1. Equippedwithwallswitch:TurnON/OFFswitchtoOFF.
Equippedwithremoteorwallcontrol: PressOFFbutton.
Equippedwiththermostat:Settemperaturetolowestsetting.
2. Service technician should turn off electricpowertothecontrolwhenperformingservice.
FOR YOUR SAFETYREAD BEFORE LIGHTING
WARNING: Ifyoudonotfollowtheseinstructionsexactly,afireorexplosionmayresultcausingpropertydamage,personalinjuryorlossoflife.
CAUTION:
NOT FOR USE WITH SOLID FUEL
WARNING:
GASVALVE
ForadditionalinformationonoperatingyourHearth&HomeTechnologiesfireplace,pleaserefertowww.hearthnhome.com.
A.Thisapplianceisequippedwithanintermittentpilotignition(IPI)devicewhichautomaticallylightstheburn-er.DO NOTtrytolighttheburnerbyhand.
B. BEFORE LIGHTING,smellallaroundtheapplianceareaforgas.Besuretosmellnexttothefloorbecausesomegasisheavierthanairandwillsettleonthefloor.
WHAT TO DO IF YOU SMELL GAS• DO NOTtrytolightanyappliance.• DO NOTtouchanyelectricswitch;donotuseanyphoneinyourbuilding.
DO NOT CONNECT LINE VOLT-AGE (110/120 VAC OR 220/240 VAC) TO THE CONTROL VALVE.Improper installation, adjustment, al-teration, service or maintenance cancauseinjuryorpropertydamage.Re-fertotheowner’sinformationmanualprovidedwiththisappliance.This appliance needs fresh air forsafe operation andmust be installedso there are provisions for adequatecombustionandventilationair.
Hotwhileinoperation.DO NOTtouch.Keepchildren,clothing,furniture,gaso-lineandotherliquidshavingflammablevaporsaway.
• Immediately call your gas supplierfromaneighbor’sphone.Followthegassupplier’sinstructions.
•If you cannot reach your gas sup-plier,callthefiredepartment.
C. DO NOTuse thisappliance ifanyparthasbeenunderwater. Imme-diatelycallaqualifiedservicetech-niciantoinspecttheapplianceandto replace any part of the controlsystemandanygascontrolwhichhasbeenunderwater.
Forusewithnaturalgasandpropane.A conversion kit, as supplied by themanufacturer,shallbeusedtoconvertthisappliancetothealternatefuel.Also Certified for Installation in a Bedroom or a Bedsitting Room.For assistance or additional informa-tion, consultaqualified installer, ser-viceagencyorthegassupplier.
Final inspection by
Keepburnerandcontrolcompartmentclean.See installationandoperatinginstructionsaccompanyingappliance.
WARNING: This product and thefuelsused tooperate thisproduct(liquid propane or natural gas),andtheproductsofcombustionof
such fuels, canexposeyou to chemicalsincludingbenzene,which isknowntotheState of California to cause cancer andreproductiveharm. Formore informationgoto:www.P65Warnings.ca.gov.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2112
1. Turnoffallelectricpowertotheapplianceifserviceistobeperformed.
2. Opencontrolaccesspanel.
3. Moveswitchto“OFF”position.
4. Pushingascontrolknobslightlyandturnclock-wise toOFF”.Donotforce.
5. Closecontrolaccesspanel.
5. Turnknobongascontrolcounterclockwise to“PILOT”.
6. Push in control knoball thewayandhold in. Im-mediatelydepressredorblackpiezobutton.Itmayrequire several depressions of the red or blackpiezobuttonuntilPILOTlights.IfPILOTlightdoesnotlightafter10seconds,returntostep3.Continuetoholdthecontrolknobinforaboutoneminuteafterthepilot is lit.Releaseknoband itwillpopbackout.Pilotshouldremainlit.Ifitgoesout,repeatsteps3through6.
• Ifknobdoesnotpopupwhenreleased,stopandim-mediatelycallyourservicetechnicianorgassupplier.
• Ifthepilotwillnotstaylitafterseveraltries,turnthegascontrolknobto“OFF”andcallyourservicetechnicianorgassupplier.
7. Turngascontrolknobcounterclockwise to “ON”.
8. TolightBurner,fliptheon/offswitchtothe“ON”position,andcloseaccessgrille.
9. Turnonallelectricpowertotheappliance.
1. Turnoffallelectricpowertotheappliance.
2. Pushingascontrolknobslightlyandturnclockwise
to“OFF”.
NOTE: Knobcannotbeturnedfrom“PILOT”to“OFF”unlessknobispushedinslightly.Donotforce.
3. Waitfive(5)minutestoclearoutanygas.Thensmellforgas,includingnearthefloor.Ifyousmellgas,STOP!Follow“B”intheSafetyInformationlocatedontheleftsideofthislabel.Ifyoudon’tsmellgas,gotonextstep.
4. Findthepilot.Thepilotisinsidecombustionchambernexttothemainburner.
LIGHTINGINSTRUCTIONS
TO TURN OFFGAS TO APPLIANCE
FOR YOUR SAFETYREAD BEFORE LIGHTING
DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.Improper installation, adjustment, al-teration, service ormaintenance cancauseinjuryorpropertydamage.Re-fertotheowner’sinformationmanualprovidedwiththisappliance.This appliance needs fresh air forsafe operation andmust be installedso there are provisions for adequatecombustionandventilationair.
CAUTION:Hotwhile inoperation.Donottouch.Keepchildren,clothing,furniture,gaso-lineandotherliquidshavingflammablevaporsaway.
NOT FOR USE WITH SOLID FUEL
Forusewithnaturalgasandpropane.A conversion kit, as supplied by themanufacturer,shallbeusedtoconvertthisappliancetothealternatefuel.Also Certified for Installation in a Bedroom or a Bedsitting Room.For assistance or additional informa-tion, consult a qualified installer, ser-viceagencyorthegassupplier.
WARNING:
A.This appliance has a pilot whichmust be lighted by hand. Whenlighting the pilot, follow these in-structionsexactly.
B. BEFORE LIGHTING, smell allaroundtheapplianceareaforgas.Be sure to smell next to the floorbecausesomegasisheavierthanairandwillsettleonthefloor.
WHAT TO DO IF YOU SMELL GAS•Donottrytolightanyappliance.• Donottouchanyelectricswitch;donotuseanyphoneinyourbuilding.
• Immediately call your gas supplierfromaneighbor’sphone.Followthegassupplier’sinstructions.
•If you cannot reach your gas sup-plier,callthefiredepartment.
C.Use only your hand to push in orturn the gas control knob. Neverusetools.Iftheknobwillnotpushinor turnbyhand,DO NOT try torepair it, call a qualified servicetechnician.Forceorattempted re-pair may result in a fire or explo-sion.
D.Do not use this appliance if anyparthasbeenunderwater. Imme-diatelycallaqualifiedservicetech-niciantoinspecttheapplianceandto replace any part of the controlsystemandanygascontrolwhichhasbeenunderwater.
ForadditionalinformationonoperatingyourHearth&HomeTechnologiesfireplace,pleaserefertowww.fireplaces.com.
WARNING: If you do not follow these instructionsexactly,afireorexplosionmayresultcausingpropertydamage,personalinjuryorlossoflife.
Final inspection by
Figure 8. Standing Pilot Lighting Instructions
Lighting Instructions (Standing Pilot)
WARNING: This product and thefuelsused tooperate thisproduct(liquid propane or natural gas),andtheproductsofcombustionof
such fuels, canexposeyou to chemicalsincludingbenzene,which isknowntotheState of California to cause cancer andreproductiveharm. Formore informationgoto:www.P65Warnings.ca.gov.
Keepburnerandcontrolcompartmentclean. See installation and operatinginstructionsaccompanyingappliance.
13Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
A. Standing Pilot Ignition System
4 4 Troubleshooting
Withproperinstallation,operation,andmaintenanceyourgasappliancewillprovideyearsoftrouble-freeservice.Ifyoudoexperienceaproblem,thistroubleshootingguidewillassistaqualifiedservicetechnicianinthediagnosisofaproblemandthecorrectiveactiontobetaken.Thistroubleshootingguidecanonlybeusedbyaqualifiedservicetechnician.Contactyourdealertoarrangeaservicecallbyaqualifiedservicetechnician.
Symptom Possible Causes Corrective Action1.Afterrepeatedtriggering
oftheredorblackpiezoignitorbutton,thesparkignitorwillnotlightthepilot.
A.Nogasorlowgaspressure. Checktheremoteshut-offvalvesfromtheappliance.Usually,thereisavalvenearthegasmain.Therecanbemorethanonevalvebetweentheapplianceandthemain.
B.Nopropaneintank. Checkthepropanetank.Youmaybeoutoffuel.
C.Ignitor. Checkthesparkattheelectrodeandpilot.Ifnosparkandelectrodewireisproperlyconnected,replacetheignitor.Verifythatthereisnoshortinelectrodewire.
D.Pilotormisalignedelectrode(sparkatelectrode).
Usingmatch,lightthepilot.Ifthepilotlights,turnoffthepilotandtriggerthepiezoignitorbuttonagain.Ifthepilotlights,animpropergas/airmixturecausedthebadlightingandalongerpurgeperiodisrecommended.Ifthepilotwillnotlight,ensurethegapattheelec-trodeandpilotisone-eighthin.tohaveastrongspark.IfthegapisOK,replacethepilot.
2.Thepilotwillnotstaylitaftercarefullyfollowingthelightinginstructions.
A.Thermocouple. Checkthatthepilotflameimpingesonthethermocouple.Adjustthepilotforproperflameimpingement.Ensurethatthethermocoupleconnectionatthegasvalveisfullyinsertedandtight(handtightenplus1/4turn).Verifypropervoltageoutputfromthethermocoupletothevalve.Placeonemillivoltmeterleadwireonthethermocouplecopperlead.Placethesecondleadwireonthesolderbuttononthebackofthevalve(bluewire).Startthepilotandholdthevalveknobin.Themillivoltreadingshouldread8-16millivolts.Ifmillivoltreadingislessthan8millivolts,replacethermocouple.
B.Impropergasinletpressure. Naturalgasshouldbe5-10in.w.c.Propaneshouldbe11-13in.w.c.Verifypressurewithmanometer.
C.Valve. Ifthethermocoupleisproducing8-16millivolts,replacecontrolvalve.
3.Thepilotisburning,thereisnoburnerflame,thevalveknobisintheONposition,andtheON/OFFswitchisintheONposition.
A.On/offswitchorwires. ChecktheON/OFFswitchandwiresforproperconnections.Placethejumperwiresacrosstheterminalsattheswitch.Iftheburnercomeson,replacetheswitch.IftheswitchisOK,placethejumperwiresacrosstheswitchwiresatthegasvalve.Iftheburnercomeson,thewiresarefaultyorconnectionsarebad.
B.Thermopilemaynotbegen-eratingsufficientmillivoltage.
Checkthatthepilotflameimpingesthermopileproperly.Besurethewireconnectionsfromthethermopileatthegasvalveterminalsaretightandthatthethermopileisfullyinsertedintothepilotbracket.Checkthethermopilewithamillivoltmeter.TakethereadingatTH-TP&TPterminalsofthegasvalve.Themetershouldread350millivoltsminimum,whileholdingthevalveknobdepressedinthepilotposition,withthepilotlit,andtheON/OFFswitchintheOFFposition.Replacethethermopileifthereadingisbelowthespecifiedminimum.WiththepilotintheONposition,disconnectthethermopileleadsfromthevalve.Takeareadingatthethermopileleads.Theread-ingshouldbe350millivoltsminimum.Replacethethermopileifthereadingisbelowtheminimum.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2114
Troubleshooting (continued)
Symptom Possible Cause Corrective Action
3.(Continued) c.Valve. TurnthevalveknobtotheONposition.PlacetheON/OFFswitchintheONposition.Checkthemillivoltmeterathethermopileterminals.Themillivoltmetershouldreadgreaterthan125mV.Ifthereadingisac-ceptable,andiftheburnerdoesnotcomeon,replacethegasvalve.
d.Pluggedburnerorifice. Checktheburnerorificeforstoppage.Removestop-page.
e.Wallswitchorwires. FollowthecorrectiveactioninSymptomandPossibleCause1.aabove.Checktheswitchandwiring.
4.Frequentpilotoutageproblem.
a.Pilotflamemaybetoohighortoolow,orblow-ingout(highpressure),causingpilotsafetytodropout.
Cleanthermocoupleandadjustthepilotflameforproperflameimpingement.Followlightinginstructionscarefully.
5.Thepilotandmainburnerextinguishwhileinoperation.
a.Nopropaneintank. Checkthepropanetank.Refillthefueltank.
b.Impropergasinletpressure. Verifywithmanometer.NGshouldread5-14in.w.c.Propaneshouldread10-14in.w.c.
c.Innerventpipeleakingexhaustgasesbackintothesystem.
Checkventingsystemfordamage.Replace/repairimproperlyassembledpipesections.
d.Glassinstalledimproperly. Checktoensureglassisinstalledproperly.Replaceglasspanelassembly.
e.Thermopileorthermocouple. Replacepilotifnecessary.
f.Improperventcapinstallation. Checkforproperinstallationandfreedomfromdebrisorblockage.
15Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
B. IntelliFire® Ignition System
Symptom Possible Cause Corrective Action
1.Pilotwon’tlight.Theignitor/modulemakesnoise,butnospark.
a.Incorrectwiring. Verify“S”wire(white)forsensorand“I”wire(orange)forignitorareconnectedtocorrectterminalsonmoduleandpilotassembly.
b.Looseconnectionsorelectricalshortsinthewiring.
Verifynolooseconnectionsorelectricalshortsinwiringfrommoduletopilotassembly.Verifyconnectionsunderneathpilotas-semblyaretight;alsoverifyconnectionsarenotgroundingouttometalchassis,pilotburner,pilotenclosure,meshscreenifpresent,oranyothermetalobject.
c.Ignitorgapistoolarge. Verifygapofignitertorightsideofpilothood.Thegapshouldbeapproximately.17in.or1/8in.(3mm).
d.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.Removeignitorwire“I”frommodule.Placeagroundedwireabout3/16in.(5mm)awayfrom“I”terminalonmodule.PlaceON/OFFrockerswitchorwallswitchinONposition.Ifthereisnosparkat“I”terminalmodulemustbereplaced.Ifthereisasparkat“I”terminal,moduleisfine.Inspectpilotassemblyforshortedsparkerwireorcrackedinsulatoraroundelectrode.Replacepilotifnecessary.
2.Pilotwon’tlight,there is no noise or spark.
a.Nopower. Checkbatteries.
b.Ashortedorlooseconnectioninwiringconfigurationorwiringhar-ness.
Removeandreinstallthewiringharnessthatplugsintomodule.Verifythereisatightfit.Verifypilotassemblywiringtomodule.Re-moveandverifycontinuityofeachwireinwiringharness.Replaceanydamagedcomponents.
c.Improperwallswitchwiring. Checkwiringconnections.
d.Modulenotgrounded. Verifyblackgroundwirefrommodulewireharnessisgroundedtometalchassisofappliance.
e.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.Re-moveignitorwire“I”frommodule.PlaceON/OFFrockerswitchorwallswitchinONposition.Ifthereisnosparkat“I”terminalmodulemustbereplaced.Ifthereisasparkat“I”terminal,moduleisfine.Inspectpilotassemblyforshortedsparkerwireorcrackedinsulatoraroundelectrode.
3.Pilotsparks,butPilotwillnotlight.
a.Gassupply. Verifythatincominggaslineballvalveis“open”.Verifythatinletpressurereadingiswithinacceptablelimits,inletpressuremustnotexceed14in.W.C.
b.Ignitorgapisincorrect. Verifythatsparkgapfromignitortopilothoodis.17in.or1/8in(3mm).
c.Moduleisnotgrounded. Verifymoduleissecurelygroundedtometalchassisofappliance.
d.Modulevoltageoutput/Valve/Pilotsolenoidohmsreadings.
Verifybatteryvoltageisatleast2.7volts.Replacebatteriesifvolt-ageisbelow2.7.
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2116
IntelliFire Ignition System - (continued)
Symptom Possible Cause Corrective Action
4.Pilotlightsbutcontin-uestospark,andmainburnerwillnotignite.(Ifthepilotcontinuestosparkafterthepilotflamehasbeenlit,flamerectificationhasnotoccurred.)
a.Ashortedorlooseconnectioninflamesensingrod.
Verifyallconnectionstowiringdiagraminmanual.Verifyconnectionsunderneathpilotassemblyaretight.Verifyconnectionsarenotgroundingouttometalchassis,pilotburner,pilotenclosureorscreenifpresent,oranyothermetalobject.
b.Poorflamerectificationorcontaminatedflamesensingrod.
Withfixedglassassemblyinplace,verifythatflameisen-gulfingflamesensingrodonleftsideofpilothood.Flamesensingrod shouldglowshortlyafterignition.Verifycor-rectpilotorificeisinstalledandgasinletissettopressurespecifications.Polishflamesensingrodwithfinesteelwooltoremoveanycontaminantsthatmayhaveaccumulatedonflamesensingrod.
c.Moduleisnotgrounded. Verifymoduleissecurelygroundedtometalchassisofappliance.Verifythatwireharnessisfirmlyconnectedtothemodule.
d.Damagedpilotassemblyorcontami-natedflamesensingrod.
Verifythatceramicinsulatoraroundtheflamesensingrodisnotcracked,damaged,orloose.Verifyconnectionfromflamesensingrodtowhitesensorwire.Polishflamesens-ingrodwithfinesteelwooltoremoveanycontaminantsthatmayhaveaccumulatedonflamesensingrod.Verifycontinuitywithamultimeterwithohmssetatlowestrange.Replacepilotifanydamageisdetected.
e.Module. TurnON/OFFrockerswitchorwallswitchtoOFFposition.Removeignitorwire“I”frommodule.PlaceON/OFFrockerswitchorwallswitchinONposition.Ifthereisnosparkat“I”terminalmodulemustbereplaced.Ifthereisasparkat“I”terminal,moduleisfine.
17Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
5 5 Reference Materials Service Parts
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERLog Assembly LOGS-CFL18
1 Log 1
Pre 5/15/16, Must order complete
assembly
SRV481-7662 Log 2 3 Log 3
SRV481-7554 Log 4 5 Log 5 SRV481-7016 Log 6 SRV481-7057 Log 7 SRV446-7028 Log 8 SRV481-7039 Log 9 SRV402-70110 Log 10 SRV446-70611 Burner Assembly 526-010A Y12 Flexible Gas Connector 477-301A Y13 Grate Assembly 526-360
14Valve NG 418-500 YValve LP 418-501 Y
15 ON/Off Switch 060-521A Y16 Flex Ball Valve Assembly SRV302-320 Y
17Pilot Assembly NG 2103-010 YPilot Assembly LP 2103-011 Y
Additional service parts on following page 2/21
Log Set Assembly
5
24
986
13
10
7
Campfire 18” Gas Log Set
CFL-18NG-C, CFL-18LP-CBeginning Manufacturing Date: Nov 2007
Ending Manufacturing Date: Active
11
12
13
14
1516
17
A. Service Parts
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2118
Service Parts
Beginning Manufacturing Date: Nov 2007 Ending Manufacturing Date: Active
CFL-24NG-C, CFL-24LP-C
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERLog Assembly LOGS-CFL24
1 Log 1
Pre 5/15/16, Must order complete
assembly
SRV481-7662 Log 2 3 Log 3
SRV481-7554 Log 4 5 Log 5 SRV526-7016 Log 6 SRV481-7057 Log 7 SRV446-7028 Log 8 SRV481-7039 Log 9 SRV402-701
10 Log 10 SRV446-70611 Burner Assembly 526-010A Y12 Flexible Gas Connector 477-301A Y13 Grate Assembly 526-360
14Valve NG 418-500 YValve LP 418-501 Y
15 ON/Off Switch 060-521A Y16 Flex Ball Valve Assembly SRV302-320 Y
17Pilot Assembly NG 2103-010 YPilot Assembly LP 2103-011 Y
Additional service parts on following page 2/21
11
12
13
14
1516
17
5
10
6
13 4
2
798
Log Set Assembly
19Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
Service Parts CFL-24NG-IPI, CFL-24LP-IPIBeginning Manufacturing Date: Aug 2009
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERLog Assembly LOGS-CFL24
1 Log 1
Pre 5/15/16, Must order complete
assembly
SRV481-7662 Log 2 3 Log 3
SRV481-7554 Log 4 5 Log 5 SRV526-7016 Log 6 SRV481-7057 Log 7 SRV446-7028 Log 8 SRV481-7039 Log 9 SRV402-70110 Log 10 SRV446-70611 Burner Assembly 526-010A Y12 Flexible Gas Connector 477-301A Y13 Grate Assembly 526-360
14Valve NG SRV593-500 YValve LP SRV593-501 Y
15 Control Module SRV593-595 Y16 ON/Off Switch 060-521A Y17 Flex Ball Valve Assembly SRV302-320 Y
18Pilot Assembly NG SRV2090-012 YPilot Assembly LP 2090-013 Y
Additional service parts on following page 2/21
11
12
13
14
1617
18
15
5
10
6
13 4
2
798
Log Set Assembly
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2120
Service Parts
Beginning Manufacturing Date: Nov 2007 Ending Manufacturing Date: Active
CFL-30NG-C, CFL-30LP-C
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERLog Assembly LOGS-CFL30
1 Log 1
Pre 5/15/16, Must order complete
assembly
SRV526-7662 Log 2 3 Log 3
SRV526-7554 Log 4 5 Log 5 SRV526-7016 Log 6 SRV481-7057 Log 7 SRV446-7028 Log 8 SRV481-7049 Log 9 SRV446-70510 Log 10 SRV446-70611 Log 11 SRV530-70312 Burner Assembly 526-010A Y13 Flexible Gas Connector 477-301A Y14 Grate Assembly 526-360
15Valve NG 418-500 YValve LP 418-501 Y
16 ON/Off Switch 060-521A Y17 Flex Ball Valve Assembly SRV302-320 Y
18Pilot Assembly NG 2103-010 YPilot Assembly LP 2103-011 Y
Additonal service parts on following page 2/21
18
12
13
14
15
1617
10 8 9
5
117
13
24
6
Log Set Assembly
21Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
Service Parts
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERMineral Wool 050-721Orifice NG (1.55) 526-801 YOrifice LP (2.30 mm) 526-800 YRemote Heat Shield 526-199Vermiculite 060-720
Standing Pilot only
Piezo Ignitor 291-513 YPilot Orifice NG SRV2103-116 YPilot Orifice LP 2103-117 YThermocouple 2103-511 YThermopile 2103-512 YWire Assembly 24 in 089-550A Y
IPI Only
Battery Pack SRV593-594 YModule Heat Shield 526-198Pilot Orifice NG SRV593-528 YPilot Orifice LP SRV593-527 YWire Assembly SRV593-590 YSingle Wire Assembly, 24 in 049-555A Y
CFL-18/24/30-CBeginning Manufacturing Date: Nov 2007
Ending Manufacturing Date: Active
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2122
B. Limited Lifetime WarrantyHearth & Home Technologies LLC
LIMITED LIFETIME WARRANTYHearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT gas, wood, pellet and electric hearth appliances (each a “Product” and collectively, the “Product(s)”) and certain component parts set forth in the table below (“Component Part(s)”) that are purchased from a HHT authorized dealer or distributor.WARRANTY COVERAGE:HHT warrants that the Products and their Component Parts will be free from defects in materials and workmanship for the applicable period of Warranty coverage set forth in the table below (“Warranty Period”). If a Product or Component Parts are found to be defective in materials or workmanship during the applicable Warranty Period, HHT will, at its option, repair the applicable Component Part(s), replace the applicable Component Part(s), or refund the purchase price of the applicable Product(s). The maximum amount recoverable under this Warranty is limited to the purchase price of the Product. This Warranty is transferable from the original purchaser to subsequent owners, but the Warranty Period will not be extended in duration or expanded in coverage for any such transfer. This Warranty is subject to conditions, exclusions, and limitations as described below. WARRANTY PERIOD:Warranty coverage begins at the date of installation. In the case of new home constructions, Warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product(s) by an independent, authorized HHT dealer or distributor, whichever occurs earlier. However, the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT, regardless of the installation or occupancy date.
The term “Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood and pellet appliances. These time periods reflect the minimum expected useful lives of the designated Component Parts under normal operating conditions.
Page 1 of 24021-645L 10/20
Component Parts Labor Gas Pellet Wood Electric Venting Component Parts Covered by this Warranty
X All parts except as covered by Warranty Conditions, Warranty Exclusions, and Warranty Limitations listed
X X Igniters, Auger Motors, Electronic Components, and Glass
XElectrical components limited to modules, remotes/wall switches, valves, pilots, blowers, junction boxes, wire
harnesses, transformers and lights (excluding light bulbs)
X X Molded Refractory Panels, Glass Liners
X Vent Free Burners, Vent Free Logs
X X Castings, Medallions and Baffles
6 years 3 years X Catalysts
7 years 3 years X X Manifold tubes, HHT Chimney and Terminations
10 years 1 year X Burners, logs and refractory
Limited Lifetime 3 years X X X Firebox and heat exchanger, FlexBurn® System
(engine, inner cover, access cover and fireback)
1 Year None X X X X X All purchased replacement parts
Warranty Period HHT Manufactured Appliances and Venting
All parts including handles, external enameled components and other material except as covered by
Warranty Conditions, Warranty Exclusions, and Warranty Limitations listed
2 years
X1 Year X X X
2 Years
5 years 1 year
Firepots, burnpots, mechanical feeders/auger assemblies3 years X
23Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, • 526-910 Rev. V • 2/21
B. Limited Lifetime Warranty (continued)WARRANTY CONDITIONS:
• Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers is available on the HHT branded websites.
• This Warranty is only valid while the applicable Product remains at the site of original installation. • This Warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applicable Product is
authorized to sell applicable Product. • Contact your installing distributor or dealer for Warranty service. If the installing dealer or distributor is unable to provide
necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking Warranty service from a dealer other than the dealer from whom you originally purchased the applicable Product.
• No HHT consumer should bear cost of warranty service or costs incurred while servicing warranty claims (i.e., travel, gas, or mileage) when the service is performed within the terms of this Warranty. Check with your dealer or distributor in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this Warranty.
WARRANTY EXCLUSIONS:This Warranty does not cover the following:• Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface
finishes may occur. This is not a flaw and is not covered under the Warranty. • Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items or other
external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes. • Repair or replacement of parts that are subject to normal wear and tear during the Warranty Period are not covered. These parts
include: paint, wood and pellet gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass. • Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to
this noise are not covered by this Warranty.• Damages resulting from: (1) failure to install, operate, or maintain the applicable Product in accordance with the installation
instructions, operating instructions, and listing agent identification label furnished with the applicable Product; (2) failure to install the applicable Product in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operation instructions; (7) installation or use of components not supplied with the applicable Product or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the applicable Product.
• Non-HHT venting components, hearth connections or other accessories used in conjunction with the applicable Product. • Any part of a pre-existing fireplace system in which an insert or a decorative gas applicable Product is installed. • HHT’s obligation under this Warranty does not extend to the Product’s capability to heat the desired space. Information is provided
to assist the consumer and the dealer in selecting the proper Product for the application. Consideration must be given to the Product location and configuration, environmental conditions, insulation and air tightness of the structure.
This warranty is void if:• The applicable Product has been over-fired, operated in atmospheres contaminated by chlorine, fluorine, or other damaging
chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, deformation/warping of interior cast iron structure or components, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.
• The applicable Product is subjected to prolonged periods of dampness or condensation. • There is any damage to the applicable Product due to water or weather damage which is the result of, but not limited to, improper
chimney or venting installation.
LIMITATIONS OF REMEDIES AND LIABILITY:• EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED
HEREIN. The owner’s exclusive remedy and HHT’s sole obligation under this Warranty or in contract, tort or otherwise, shall be limited to replacement of the Component Part(s), repair of the Component Part(s), or refund of the original purchase price of the applicable Product(s), as specified above; provided, however, that (i) if HHT is unable to provide replacement of the Component Part(s) and repair of the Component Part(s) is not commercially practicable or cannot be timely made, or (ii) the customer is willing to accept a refund of the purchase price of the applicable Product(s), HHT may discharge all such obligations by refunding the purchase price of the applicable Product. In no event will HHT be liable for any incidental or consequential damages caused by defects in the applicable Product. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Page 2 of 24021-645L 10/20
Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI • 526-910 Rev. V • 2/2124
Hearth&HomeTechnologies 7571215thStreetWest,Lakeville,MN55044
www.hearthnhome.com
- NOTES -
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
DO NOT DISCARD THIS MANUALCAUTION
• Leave thismanualwithpartyresponsibleforuseandoperation.
• Important operatingand maintenanceinstructionsincluded.
• Read,understandandfollowtheseinstructionsforsafeinstallationandoperation.
C. Contact Information
Printed in U.S.A. - Copyright 2021
PleasecontactyourHearth&HomeTechnologiesdealerwithanyquestionsorconcerns.ForthelocationofyournearestHearth&HomeTechnologiesdealer,
pleasevisitwww.hearthnhome.com.
This product may be covered by one or more of the following patents: (United States) 6601579, 6769426, 6863064, 7077122, 7074035, 7098269, 7234932, 7258116, 7322819, 7422011, 7470729, 7726300, 8147240, 9625149 or other U.S. and foreign patents pending.
2000-945E