TI-BA Enterprises
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Toshiba Flat Panel DR Systems
What makes Toshiba DR the best choice for digital imaging conversion?
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
14x17 Tethered
17x17 Fixed
Why is Toshiba the Best for Retrofit?
• Because it offers the best image quality• Because it is the most reliable• Because it offers consistent performance• Because it requires the least amount of dose per exam• Because it is the most flexible• Because it is intuitive• Because it offers the longest warranty – 3 Years• Because it is the most affordable
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
The Best Image Quality
Factors Affecting Flat Panel Detector (FPD) Image Quality
• FPD Performance• Input Dose• Enhancement Algorithm • System Calibration
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Toshiba Performance Comparison vs. Thales Panel Used by Siemens & Philips
Pixel Pitch 143
microns
A/D 16 bit
MTF 2lp/mm 36 %
DQE 70%
Max Dose 50 u/gy
Max Linear Dose 36 u/gy
Pixel Pitch 148 microns
A/D 16 bit
MTF 2lp/mm 35%
DQE 66%
Max Dose 48u/gy
Max Linear Dose 40u/gy
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Toshiba FPD Thales FPD
Panel Performance• Toshiba panels use advanced and proven fine structured CsI:Tl and direct vapor deposition
technology deliver higher sensitivity and better resolution.
• Reflection coating on CsI:Tl screen enables excellent Detective Quantum Efficiency (DQE) and low noise.
• A high Modulation Transfer Function (MTF) FPD is the result of these outstanding technologies diagnostic images, while delivering the benefits of lower radiation dose to the patient.
• The FDX3543RP and FDX4343R achieves a new level of functionality and reliability in developing functional FPD’s for system manufacturers.
Image of Cesium Iodide Crystalline Structure
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Flat Panel Detector Input Dose Requirement• Since digital Flat Panel Detectors can produce acceptable
images over a wide range of input doses, it is imperative that the entrance dose to the panel for every view is kept at the minimum usable level.
• The Association of Physicist’s in Medicine (AAPM) has established a procedure and mythology for insuring that the correct dose is given to the patient for each view of various patient sizes.
• This exposure index number is the result of measuring the average radiation to the FPD for a given view. A target exposure index is given for each view and the Udicon Software measures and calculates the actual radiation dose to the panel vs the target and a deviation Index is displayed. The Toshiba DR retrofit adds this information to the DICOM header and display.
• The Udicon Software for Toshiba DR Panels also supports Dose Area Products devices that measures the actual radiation at a point before entering the patient
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
PATIENT DOSE MEASUREMENT
• Dose Area Product• Exposure Index
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
EXPOSURE INDEX• Target Index• Deviation Index
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Toshiba Dose Features
• Techniques displayed on DICOM header• Exposure Index displayed on DICOM header
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Results!
• Customer’s have been able to cut dose in half with Toshiba DR from their existing CR techniques.
• There has been no compromise in image quality.
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
IMAGE ENHANCEMENT• What is it• Building a Data Base• Making Adjustments
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
The Best Image Quality
Image Enhancement also known as Image Post Processing is a critical component in the development of the digital Image.
Toshiba DR Retrofits use enhancement software developed by Context Vision, a world leader and Gold Standard for Medical Digital Image Processing.
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Image Enhancement by Context Vision
GOP® methodology is unique in detecting structures by examining the significance of each pixel in an image in relation to the wider context in which they appear. In this way, once the structure is identified and analyzed, noise can be suppressed and the true structure, however weak, can be emphasized and seen more clearly.
Image Enhancement
• Reduces noise and artifacts in the digital image • Enhances edges and lines to display more clearly defined structures • Enhances image contrast, making vague structures strong • Provides latitude compression so that structures in both dense and translucent areas are visible simultaneously
Clinical Value
• Better visibility and contrast of small and/or weak structure• Better depiction of overlapping structures in digital radiology • Better delineation of bone structures in digital radiology • Simultaneous viewing of bone and soft tissue in digital radiology
Consistent PerformanceEach image is enhance based on a predetermined set of tables that ensures that if you take 10 shots of a given anatomy all images will be the same. You will not have a drift in window and level like many other systems.
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Enhancement Selection• Soft• Medium• Sharp
Available for each view
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Results
Radiologists who have view our images have commented that the Toshiba FPD images taken are the best they have ever seen.
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Intuitive Workstation• All workstation functions at the touch of a button • Patient setup & exam completion is easy to follow • Users become very productive immediately
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
RIS & PACS
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
UDI 1717
RIS
RIS BrokerPACS Archive
Server
HL-7
DicomWorklist
Dicom Send
DicomMedia
Storage
Dicom Print
DVD Robot
LaserCam
Remote Review
Diagnostic review
Clinical review
UDI 1717 has all built-in Dicom Features for full workflow automation
Because it is very Flexible
Wireless, Tethered, Fixed with many combinations
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Featuring “Med Share” Any Panel ANYWHERE
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
It Is Reliable
Each component of the Toshiba Upgrade has passed stringent FDA,UL, FCC, ISO and CE certification. The components that make up the Toshiba DR Retrofit have been thoroughly tested to ensure long lasting to life.
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Retrofits with Generator Interface
Smart Systems• GE Proteus• Philips Optimus• Sedecal Generators• CPI Generators
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Toshiba Portable Retrofit Solutions
Toshiba Panels can be used to Retrofit Many Portables:
• GE AMX• GE AMX4• Siemens Mobilet
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com
Thank You!
Please call us to schedule an online software demonstration or to learn more
about Toshiba FPD installation at your site.
Tel (585) 247-1212www.ti-ba.com
For sales information please contact TI-BA Enterprises - Tel (585) 247-1212 - email: [email protected] - www.ti-ba.com