7
J Thermocouple Data Temp to Volts 760 1200 C0 0.0000000000E+00 2.9645625681E+05 C1 5.0381187815E+01 -1.4976127786E+03 c2 3.0475836930E-02 3.1787103924E+00 c3 -8.5681065720E-05 -3.1847686701E-03 c4 1.3228195295E-07 1.5720819004E-06 c5 -1.7052958337E-10 -3.0691369056E-10 c6 2.0948090697E-13 0.0000000000E+00 c7 -1.2538395336E-16 0.0000000000E+00 c8 1.5631725697E-20 0.0000000000E+00 Volts to Temp Temp Range Volt Range 0 0.042919 c0 0.0000000000E+00 0.0000000000E+00 c1 1.9528268000E-02 1.9784250000E-02 c2 -1.2286185000E-06 -2.0012040000E-07 c3 -1.0752178000E-09 1.0369690000E-11 c4 -5.9086933000E-13 -2.5496870000E-16 c5 -1.7256713000E-16 3.5851530000E-21 c6 -2.8131513000E-20 -5.3442850000E-26 c7 -2.3963370000E-24 5.0998900000E-31 c8 -8.3823321000E-29 0.0000000000E+00 ADC Vref 5 This parameter is the reference voltage used ADC Resolution (bits) 8 This parameter determines how large of a dat Op-Amp Gain 100 This parameter determines what the thermocou ixed Point Multiplier 1 This parameter specifies what the results ar Data Table Size 256 This parameter is the number of bytes the fi Input Offset Voltage 1 This parameter specifies how much the multip Calculator Temperature (F) Temperature (C Thermocouple Voltage Voltage at the ADC 2000 #VALUE! #VALUE! #VALUE! -210C to 760C 760C to 1200C -210 to 0C 0 to 760 -8095 to 0uV 0 to 42919uV

table calculator.xls

Embed Size (px)

Citation preview

Page 1: table calculator.xls

J Thermocouple DataTemp to Volts

760 1200C0 0.0000000000E+00 2.9645625681E+05C1 5.0381187815E+01 -1.4976127786E+03c2 3.0475836930E-02 3.1787103924E+00c3 -8.5681065720E-05 -3.1847686701E-03c4 1.3228195295E-07 1.5720819004E-06c5 -1.7052958337E-10 -3.0691369056E-10c6 2.0948090697E-13 0.0000000000E+00c7 -1.2538395336E-16 0.0000000000E+00c8 1.5631725697E-20 0.0000000000E+00

Volts to Temp

Temp Range

Volt Range0 0.042919

c0 0.0000000000E+00 0.0000000000E+00c1 1.9528268000E-02 1.9784250000E-02c2 -1.2286185000E-06 -2.0012040000E-07c3 -1.0752178000E-09 1.0369690000E-11c4 -5.9086933000E-13 -2.5496870000E-16c5 -1.7256713000E-16 3.5851530000E-21c6 -2.8131513000E-20 -5.3442850000E-26c7 -2.3963370000E-24 5.0998900000E-31c8 -8.3823321000E-29 0.0000000000E+00

ADC Vref 5 This parameter is the reference voltage used by the ADCADC Resolution (bits) 8 This parameter determines how large of a data table to build

Op-Amp Gain 100 This parameter determines what the thermocouple voltage is for each ADC readingFixed Point Multiplier 1 This parameter specifies what the results are multiplied by before they go into the table

Data Table Size 256 This parameter is the number of bytes the final table will beInput Offset Voltage 1 This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC

CalculatorTemperature (F) Temperature (C) Thermocouple Voltage Voltage at the ADC

2000 #VALUE! #VALUE! #VALUE!

-210Cto

760C

760Cto

1200C

-210to0C

0to

760-8095

to0uV

0to

42919uV

Page 2: table calculator.xls
Page 3: table calculator.xls

0.069553-3.1135818700E+03

3.0054368400E-01-9.9477323000E-061.7027663000E-10

-1.4303346800E-154.7388608400E-210.0000000000E+000.0000000000E+000.0000000000E+00

This parameter is the reference voltage used by the ADCThis parameter determines how large of a data table to buildThis parameter determines what the thermocouple voltage is for each ADC readingThis parameter specifies what the results are multiplied by before they go into the tableThis parameter is the number of bytes the final table will beThis parameter specifies how much the multiplied thermocouple voltage is offset before the ADC

ADC Result#VALUE!

760to

120042919

to69553uV

Make Table

Page 4: table calculator.xls
Page 5: table calculator.xls

K Thermocouple Data0 1372

C0 0.0000000000E+00 -1.7600413686E+01C1 3.9450128025E+01 3.8921204975E+01c2 2.3622373598E-02 1.8558770032E-02c3 -3.2858906784E-04 -9.9457592874E-05c4 -4.9904828777E-06 3.1840945719E-07c5 -6.7509059173E-08 -5.6072844889E-10c6 -5.7410327428E-10 5.6075059059E-13c7 -3.1088872894E-12 -3.2020720003E-16c8 -1.0451609365E-14 9.7151147152E-20c9 -1.9889266878E-17 -1.2104721275E-23c10 -1.6322697486E-20a0 1.1859760000E+02a1 -1.1834320000E-04

Volts to TempTemp Range -200 to 0C 0 to 500CVolt RangeRange Points 0 0.020644c0 0.0000000000E+00 0.0000000000E+00c1 2.5173462000E-02 2.5083550000E-02c2 -1.1662878000E-06 7.8601060000E-08c3 -1.0833638000E-09 -2.5031310000E-10c4 -8.9773540000E-13 8.3152700000E-14c5 -3.7342377000E-16 -1.2280340000E-17c6 -8.6632643000E-20 9.8040360000E-22c7 -1.0450598000E-23 -4.4130300000E-26c8 -5.1920577000E-28 1.0577340000E-30c9 -1.0527550000E-35

ADC Vref 5 This parameter is the reference voltage used by the ADCADC Resolution (bits) 8 This parameter determines how large of a data table to build

Op-Amp Gain 120 This parameter determines what the thermocouple voltage is for each ADC readingFixed Point Multiplier 10 This parameter specifies what the results are multiplied by before they go into the table

Data Table Size 256 This parameter is the number of bytes the final table will beInput Offset Voltage 0 This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC

CalculatorTemperature (F) Temperature (C) Thermocouple Voltage Voltage at the ADC

110 #VALUE! #VALUE! #VALUE!

Temp to mVolts

-5,891 to 0mV 0 to 20,644mV

Make Lookup Table

Page 6: table calculator.xls
Page 7: table calculator.xls

Column C is good for temperatures less than C3 (0 degrees C)Column D is good for temperatures less than D3 (1372 degrees C)

500 to 1372 C

0.054886-1.3185800000E+02

4.8302220000E-02-1.6460310000E-065.4647310000E-11

-9.6507150000E-168.8021930000E-213.1108100000E-26

This parameter determines how large of a data table to buildThis parameter determines what the thermocouple voltage is for each ADC readingThis parameter specifies what the results are multiplied by before they go into the table

This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC

ADC Result#VALUE!

20,644 to 54,886mV

Make Lookup Table