Upload
juliogiorgi
View
216
Download
3
Embed Size (px)
Citation preview
J Thermocouple DataTemp to Volts
760 1200C0 0.0000000000E+00 2.9645625681E+05C1 5.0381187815E+01 -1.4976127786E+03c2 3.0475836930E-02 3.1787103924E+00c3 -8.5681065720E-05 -3.1847686701E-03c4 1.3228195295E-07 1.5720819004E-06c5 -1.7052958337E-10 -3.0691369056E-10c6 2.0948090697E-13 0.0000000000E+00c7 -1.2538395336E-16 0.0000000000E+00c8 1.5631725697E-20 0.0000000000E+00
Volts to Temp
Temp Range
Volt Range0 0.042919
c0 0.0000000000E+00 0.0000000000E+00c1 1.9528268000E-02 1.9784250000E-02c2 -1.2286185000E-06 -2.0012040000E-07c3 -1.0752178000E-09 1.0369690000E-11c4 -5.9086933000E-13 -2.5496870000E-16c5 -1.7256713000E-16 3.5851530000E-21c6 -2.8131513000E-20 -5.3442850000E-26c7 -2.3963370000E-24 5.0998900000E-31c8 -8.3823321000E-29 0.0000000000E+00
ADC Vref 5 This parameter is the reference voltage used by the ADCADC Resolution (bits) 8 This parameter determines how large of a data table to build
Op-Amp Gain 100 This parameter determines what the thermocouple voltage is for each ADC readingFixed Point Multiplier 1 This parameter specifies what the results are multiplied by before they go into the table
Data Table Size 256 This parameter is the number of bytes the final table will beInput Offset Voltage 1 This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC
CalculatorTemperature (F) Temperature (C) Thermocouple Voltage Voltage at the ADC
2000 #VALUE! #VALUE! #VALUE!
-210Cto
760C
760Cto
1200C
-210to0C
0to
760-8095
to0uV
0to
42919uV
0.069553-3.1135818700E+03
3.0054368400E-01-9.9477323000E-061.7027663000E-10
-1.4303346800E-154.7388608400E-210.0000000000E+000.0000000000E+000.0000000000E+00
This parameter is the reference voltage used by the ADCThis parameter determines how large of a data table to buildThis parameter determines what the thermocouple voltage is for each ADC readingThis parameter specifies what the results are multiplied by before they go into the tableThis parameter is the number of bytes the final table will beThis parameter specifies how much the multiplied thermocouple voltage is offset before the ADC
ADC Result#VALUE!
760to
120042919
to69553uV
Make Table
K Thermocouple Data0 1372
C0 0.0000000000E+00 -1.7600413686E+01C1 3.9450128025E+01 3.8921204975E+01c2 2.3622373598E-02 1.8558770032E-02c3 -3.2858906784E-04 -9.9457592874E-05c4 -4.9904828777E-06 3.1840945719E-07c5 -6.7509059173E-08 -5.6072844889E-10c6 -5.7410327428E-10 5.6075059059E-13c7 -3.1088872894E-12 -3.2020720003E-16c8 -1.0451609365E-14 9.7151147152E-20c9 -1.9889266878E-17 -1.2104721275E-23c10 -1.6322697486E-20a0 1.1859760000E+02a1 -1.1834320000E-04
Volts to TempTemp Range -200 to 0C 0 to 500CVolt RangeRange Points 0 0.020644c0 0.0000000000E+00 0.0000000000E+00c1 2.5173462000E-02 2.5083550000E-02c2 -1.1662878000E-06 7.8601060000E-08c3 -1.0833638000E-09 -2.5031310000E-10c4 -8.9773540000E-13 8.3152700000E-14c5 -3.7342377000E-16 -1.2280340000E-17c6 -8.6632643000E-20 9.8040360000E-22c7 -1.0450598000E-23 -4.4130300000E-26c8 -5.1920577000E-28 1.0577340000E-30c9 -1.0527550000E-35
ADC Vref 5 This parameter is the reference voltage used by the ADCADC Resolution (bits) 8 This parameter determines how large of a data table to build
Op-Amp Gain 120 This parameter determines what the thermocouple voltage is for each ADC readingFixed Point Multiplier 10 This parameter specifies what the results are multiplied by before they go into the table
Data Table Size 256 This parameter is the number of bytes the final table will beInput Offset Voltage 0 This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC
CalculatorTemperature (F) Temperature (C) Thermocouple Voltage Voltage at the ADC
110 #VALUE! #VALUE! #VALUE!
Temp to mVolts
-5,891 to 0mV 0 to 20,644mV
Make Lookup Table
Column C is good for temperatures less than C3 (0 degrees C)Column D is good for temperatures less than D3 (1372 degrees C)
500 to 1372 C
0.054886-1.3185800000E+02
4.8302220000E-02-1.6460310000E-065.4647310000E-11
-9.6507150000E-168.8021930000E-213.1108100000E-26
This parameter determines how large of a data table to buildThis parameter determines what the thermocouple voltage is for each ADC readingThis parameter specifies what the results are multiplied by before they go into the table
This parameter specifies how much the multiplied thermocouple voltage is offset before the ADC
ADC Result#VALUE!
20,644 to 54,886mV
Make Lookup Table