20 Minute C-11, 10 Minute N-13 and 2 Minute O-15 Gas Emissions from BLIP Collider-Accelerator Department 4-13-2010. Take 5 for Safety. Textbook Cone-Shaped Plume. Short Stack and Lower Nearby Buildings – Wind Tunnel Simulation. Wake Effect from Building or Cone-shaped Hill. Cavity Zone. - PowerPoint PPT Presentation
Citation preview
20 Minute C-11, 10 Minute N-13 and 2 Minute O-15 Gas Emissions from BLIP
Collider-Accelerator Department4-13-2010
Take 5 for Safety
Textbook Cone-Shaped Plume
2
Short Stack and Lower Nearby Buildings – Wind Tunnel Simulation
Wake Effect from Building or Cone-shaped Hill
Cavity Zone Heat from ground
produces recirculation inside the cavity zone
3
BLIP Building Looking North
4
Inside BLIP
5
Looking West From BLIP
6
Looking South From BLIP
7
North Side of BLIP Building
8
North Side of BLIP Building Looking from “NSRL Valley”
9
MicroR/h on April 6, 6 PM, 20 mm Water Path for Beam, 485 CFM, Routine Medical Production Targets, 117 MeV Beam
Radiation survey was performed at various outdoor locations around the following buildings/facilities:· NSRL, EBIS, HITL, REF, and LINAC· No readings above background were found in these
areas Outside wall of BLIP was 2000 microR/h near
cooling water pipe
10
MicroR/h on April 7, 11 am, BLIP Off
11
MicroR/h on April 8, 5 AM, South Wind, 65 mm Water Path, 485 CFM, 181 MeV Beam, Simos Targets Plus Normal BLIP Targets
12
MicroR/h on April 8, 2 PM, South Wind, Reduced Water Path to 50 mm (25%) and Reduced Ventilation to 300 CFM (38%)
BLIP outside wall reduced from 8000 microR/h to 6000 microR/h (25%)
Area exposure rates dropped to 20 to 30 microR/h along the NSRL beam line, and 8 microR/h inside the NSRL building
Factor of 3 ± 1 reduction in NSRL area exposure rates
This met BNL criteria for less than 50 microR/h in uncontrolled areas, and C-AD HP requirement for less than 13 microR/h background to release NSRL targets
13
MicroR/h on April 10, 2 PM, West Wind, Reduced Water Path to 50 mm and Reduced Ventilation to 300 CFM
14
MicroR/h on April 12, 12:30 AM, North Wind, 50 mm Water Path, 300 CFM, 181 MeV
15
Next Steps
Finish FY10 BLIP program with Simos targets and 50 mm or less water path and 300 CFM
Develop system to independently review modifications to BLIP targets and stack
Options:· Increase stack height· Minimize water path to 20 mm or less