Upload
buithuan
View
213
Download
0
Embed Size (px)
Citation preview
TBOOTH WIRELESS TB432
SCARBOROUGH TOWN CENTRE
TITLE SHEET
A0.0
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
JOHN E. GUSTAVSON ARCHITECT
4th Floor - 576 Seymour Street
Vancouver, BC V6B 3K1
Tel: 604-687-2511
Fax: 604-687-4203
Contact: David Cheung
Email: [email protected]
A0.0 TITLE SHEET
A1.0 COVER SHEET
A2.0 DEMOLITION PLAN
A2.1 CONSTRUCTION PLAN
A2.2 FIXTURE PLAN
A2.3 FINISHES PLAN
A2.4 POWER AND DATA PLAN
A3.0 WALL SECTIONS
A4.0 INTERIOR ELEVATIONS
A4.1 INTERIOR ELEVATIONS
A6.0 DEMOLITION REFLECTED CEILING PLAN
A6.1 REFLECTED CEILING PLAN
MW-0.0 MILLWORK COVER SHEET
MW-1.0 MILLWORK DETAILS
MW-2.0 MILLWORK DETAILS
MW-3.0 MILLWORK DETAILS
MW-4.0 MILLWORK DETAILS
MW-5.0 MILLWORK DETAILS
MW-6.0 MILLWORK DETAILS
MW-7.0 MILLWORK DETAILS
MW-8.0 MILLWORK DETAILS
DRAWING LIST
JOHN E. GUSTAVSON ARCHITECT
4TH FLOOR, 576 SEYMOUR STREET
VANCOUVER, BC V6B 3K1
ONTARIO BUILDING CODE 2012 PART 3 [DIV]
TENANT IMPROVEMENT FOR UNIT 758
2 STOREYS ABOVE GRADE
REQUIRED, PROVIDEDSPRINKLERED BUILDING
REQUIREDSTANDPIPE 3.2.9.
REQUIRED (EXITS AND ACCESS TO EXITS)EMERGENCY LIGHTING 3.2.7.3
BY SF OF BUILDINGOCCUPANT LOAD
TABLE 3.1.17.1.
BY DESIGN OF BUILDING
GROUP E, MERCHANTILE
UNIT 758, 300 BOROUGH DRIVE, SCARBOROUGH, ONTARIO, M1P 4P5
CONSTRUCTION TYPE: NON-COMBUSTIIBULE CONSTRUCTION, SPRINKLERED.
FLOOR ASSEMBLIES: FIRE SEPARATION WITH A FIRE-RESISTANCE RATING NOT LESS
THAN 2 HRS.
MEZZANINES: FIRE-RESISTANCE RATING NOT LESS THAN 1 HR.
LOADBEARING WALLS, COLUMNS AND ARCHES: SHALL HAVE FIRE-RESISTANCE
RATING NOT LESS THAN THAT REQURIED FOR THE SUPPORTED ASSEMBLY.
CODE ANALYSIS
ONTARIO BUILDING CODE 2012
30 MINUTES REQUIREDEMERGENCY POWER FOR LIGHTING 3.2.7.4
ARCHITECTURAL
CONSULTANT LIST
FIRM NAME
APPLICABLE CODE
CIVIC ADDRESS
PROJECT DESCRIPTION
MAJOR OCCUPANCY
NUMBER OF STOREYS
3.1.2.1.(1)
PERMITTED CONSTRUCTION
NOT APPLICABLENUMBER OF STREETS (FIRE ROUTES)
GROUP E, ANY HEIGHT, ANY AREA, SPRINKLERED 3.2.2.57.BUILDING CLASSIFICATION
3.2.5.13.
3.2.2.57.
NON-COMBUSTIBLEACTUAL CONSTRUCTION 3.2.2.57.
REQUIRED, PROVIDED 3.2.4.1FIRE ALARM
ADEQUATE 3.2.5.7.FIRE FIGHTING WATER SUPPLY
NO 3.2.6.HIGH BUILDING
REQUIRED
ACCESS PROVIDED TO AREAS TO WHICH THE PUBLIC IS ADMITTED
ARCHITECTURAL
3.8.
BARRIER-FREE DESIGN:
NO
AREA OF PROJECT
RETAIL AREA - 840 SF / 39.8 SF = 21.1
STORAGE AREA - 110 SF / 301.4 SF = 0.36
OCCUPANCY LOAD: 22 PERSONS (AREA OF PROJECT ONLY)
3.3.1.2, 3.3.1.19HAZARDOUS SUBSTANCES
TB432
TBOOTH WIRELESS
SCARBOROUGH
TOWN CENTRE
UNIT 758, 300 BOROUGH DRIVE
SCARBOROUGH, ONTARIO
91.4 SM (984.0 SF) AT UNIT 758
BUILDING AREAEXISTING (NO CHANGE)
MECHANICAL
ELECTRICAL
TBOOTH WIRELESS
UNIT 758
PROJECT
NORTH
TR
UE
NO
RT
H
1.4.1.2. [A] & 3.2.1.1.
OXFORD PROPERTIES GROUP
Royal Bank Plaza, North Tower
200 Bay Street, Suite 900
Toronto, ON M5J 2J2
Tel: 416-868-3710
Cel: 416-906-4283
Contact: Alana de Haan
Email: [email protected]
OWNER
GLENTEL INC.
8501 Commerce Court
Burnaby, BC V5A 4N3
Tel: 604-415-6538
Fax: 604-415-6515
Contact: Adrian Ching
Email: [email protected]
LANDLORD
SNC-LAVALIN INC.
235 Lesmill Road
Toronto, ON M3B 2V1
Tel: 416-445-8255
Fax: 416-445-7885
Contact: Co Tran
Email: [email protected]
MECHANICAL & ELECTRICAL
AFF ABOVE FINISHED FLOOR
AL, ALUM. ALUMINUM
BLDG BUILDING
CG CORNER GUARD
CJ CONTROL JOINT
CLA CLEAR ANODIZED
CLR CLEAR FINISH
CLG CEILING
CMU CONCRETE MASONRY UNIT
CT CERAMIC TILE
C/W COMPLETE WITH
CONC CONCRETE
DWG DRAWING
DIA (Ø) DIAMETER
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EQ EQUAL
EX EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FIN FINISH
FRR FIRE RESISTANCE RATING
GA GAUGE
GR GRADE
GWB GYPSUM WALL BOARD
GC GENERAL CONTRACTOR
H/C HANDICAPPED
HM HOLLOW METAL
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MIN MINIMUM
MTL METAL
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
PS PRESSED STEEL
PNT PAINTED
PLAM PLASTIC LAMINATE
PLY PLYWOOD
PT PRE-TREATED
RB RUBBER BASE
REQ'D REQUIRED
RD ROOF DRAIN
STRUCT STRUCTURAL
SPEC SPECIFICATIONS
SS STAINLESS STEEL
SF, SQ.FT. SQUARE FEET
TYP TYPICAL
T/O TOP OF
U/S UNDER SIDE
VIF VERIFY IN FIELD
WC WATER CLOSET
WD WOOD
WT WEIGHT
LIST OF ABBREVIATIONS
NON-COMBUSTIBLE CONSTRUCTION
FULLY SPRINKLERED BUILDING
1. REFER TO GLENTEL'S INVITATION TO BIDDERS FOR
SUMMARY OF SCOPE OF WORK
2. G.C. MILLWORK PACKAGE INCLUDED WITH TENDER
SET IS FOR INFORMATION AND COORDINATION ONLY.
GC TO REVIEW REQUIRED LOCATIONS FOR ALL
POWER AND DATA CONNECTION POINTS REQUIRED
IN MILLWORK AND COORDINATE OUTLETS
ACCORDINGLY. REFER TO INVITATION TO BID,
AND/OR SCOPE OF WORK SUMMARY TO CONFIRM IF
THE OWNER WOULD LIKE A SEPARATE BID PRICE TO
COMPLETE THE REQUIRED MILLWORK PACKAGE.
3. DURING TENDER PERIOD, QUESTIONS RELATED TO
ARCHITECTURAL, G.C. TO CONTACT TO GWA AND
QUESTIONS RELATED TO MILLWORK, CONTACT
SHIKITANI LECROIX DESIGN.
4. CONSTRUCTION SHALL COMPLY WITH ALL
APPLICABLE STANDARD CONDITIONS AND CODES AS
PER OBC 2012 OR AUTHORITY HAVING JURISDICTION.
5. G.C. TO PROVIDE SIGNED AND SEALED SHOP
DRAWINGS FROM ENGINEER REGISTERED IN THE
PROVINCE OF ONTARIO FOR MODIFIED SPRINKLER
SYSTEM TO SUIT NEW FIXTURE AND EQUIPMENT
PLAN.
6. DURING CONSTRUCTION, ACCESS SHALL BE
PROVIDED TO ALL AREA OF THE SITE COMPLETELY
AROUND STRUCTURES.
7. CONTRACTOR IS RESPONSIBLE FOR OBTAINING
OCCUPANCY PERMIT AT THE TIME OF SUBSTANTIAL
COMPLETION.
8. TEMPORARY CONSTRUCTION HOARDING SHALL BE
MADE SUBJECT TO THE REVIEW AND APPROVAL OF
THE LOCAL BUILDING DEPT. AND LANDLORD DESIGN
GUIDELINES.
9. MEASURE SHALL BE TAKEN TO CONTAIN ALL
CONSTRUCTION DEBRIS, TRASH AND MATERIALS
ON-SITE UNTIL DISPOSAL OFF-SITE CAN BE
ARRANGED.
10.PROVIDE FIRE SAFETY PLAN TO THE SATISFACTION
OF THE LOCAL FIRE AUTHORITY.
8. G.C. TO FACILITATE ALL PERMIT REQUIREMENT FOR
ANY OWNER SUPPLIED ITEMS IF REQUIRED.
9. PRIOR TO OBTAINING OCCUPANCY AND FINAL
INSPECTION FROM THE CITY, COORDINATING
REGISTERED PROFESSIONAL ON RECORD WILL
INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING
ITEMS BEFORE TURNING OVER THEIR FINAL
SCHEDULES:
- DEMONSTRATION OF A LIFE SAFETY SYSTEM,
INCLUDING OBSERVATION OF A FIRE ALARM SYSTEM,
SUCH AS A PULL TEST, TEST OF EMERGENCY
SYSTEMS, EXIT SIGNS AND EMERGENCY LIGHTING
ETC.
- CONTRACTOR TO SUBMIT ALL SUPPORTING
DOCUMENTATION AND SCHEDULES.
- FIRE ALARM VERIFICATION REPORT AND ULC
MONITORING
- FIRE STOPPING LETTER FROM CONTRACTOR
- DRAFT STOP INSTALLATION DRAWING AND LETTER
FROM CONTRACTOR
- INSTALLATION AND NEW FIRE SAFETY PLAN AND
CONFIRMATION/VALIDITY OF ALL FIRE EXTINGUISHER
AND PULL STATION LOCATIONS.
CONSTRUCTION NOTES
Upper
Level
1.4.1.2. [A]
M-1 MECHANICAL LEGEND, SCHEDULES AND SPECS.
M-2 MECHANICAL PLAN
E1 ELECTRICAL SPECIFICATION AND DETAILS
E2 ELECTRICAL LIGHTING LAYOUT
E3 ELECTRICAL POWER LAYOUT
EXP SERVICES INC.
220 Commerce Valley Drive West, Suite 500
Markham, ON L3T 0A8
Tel: 905-695-3217
Fax: 905--695-0167
Contact: Darrell Sakauye
Email: [email protected]
STRUCTURAL
COVER SHEET
A1.0
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
1
LOCATION MAP
N.T.S. SCALE:
2
MALL UNIT PLAN
N.T.S.SCALE:
1
LOCATION MAP
N.T.S. SCALE:
2
MALL UNIT PLAN
N.T.S.
NORTH NORTH
A
FE
12'-4"
8'-0
"4
8'-1
0"
23
'-9
"
1
7
'
-
3
"
15'-0"
2
3
'
-
3
1
/
2
"
1'-6"
7"
6'-4
"1
'-4
"
EXISTING FIRE HOSE CABINET TO REMAIN
EXISTING GRILLE ENCLOSURE AND POCKET DOOR
TO BE REMOVED. PREPARE REMAINING
SURFACES FOR NEW STOREFRONT
CONSTRUCTION AS PER DWG. A2.1
ANY WORK AFFECTING LL BASE BUILDING, SUCH AS
SPRINKLER SYSTEM, HVAC SYSTEM,ROOF WORK, TILE
WORK OUTSIDE OF LEASED AREA OR ELECTRICAL WORK
OUTSIDE OF LEASED AREA WILL BE REQUIRED TO BE
PERFORMED BY A LL DESIGNATED OR LL APPROVED
CONTRACTOR AND BE ENGAGED BY THE TENANT.
LEASE LINE
EXISTING GRILLE DOOR AND TRACK TO BE
REMOVED.
EXISTING DEMISING CAP TO REMAIN AND
PROTECTED TO BE IN LIKE NEW CONDITION.
PATCH AND REPAIR AS REQUIRED TO MATCH
EXISTING (TYP. BOTH SIDES)
REMOVE EXISTING STOREFRONT PARTITIONS AND
MILLWORK. PREPARE REMAINING SURFACES FOR
RENEW STOREFRONT CONSTRUCTION AS PER
DWG. A2.1
SAW CUT TRENCH IN EXISTING CONCRETE TOPPING.
REFER TO ELECTRICAL AND DWG. 2/A2.4
SAW CUT TRENCH IN EXISTING CONCRETE
TOPPING. REFER TO ELECTRICAL AND DWG. 2/A2.4
SAW CUT TRENCH IN EXISTING CONCRETE
TOPPING. REFER TO ELECTRICAL AND DWG. 2/A2.4
COORDINATE WITH OXFORD'S STRUCTURAL
ENGINEER FOR SCANNING REQUIREMENT. AVOID
ANY REBAR IN CONCRETE.
ALL EXISTING MILLWORK AND FURNITURE TO BE REMOVED
EXCEPT AS NOTED. PATCH AND REPAIR SURROUNDING
AREA AS REQUIRED TO MAKE READY FOR NEW FINISHES &
FIXTURES. ALL NEW & RE-PURPOSED MILLWORK FIXTURES
TO BE FURNISHED BY OWNER, INSTALLED BY GC.
ADDITIONAL DEMO NOTES:
· REFER TO DWG. A6.0 DEMOLITION REFLECTED
CEILING PLAN FOR ADDITIONAL DEMOLITION SCOPE.
· CONTRACTOR TO VERIFY ALL SITE CONDITIONS &
REPORT ANY DISCREPANCIES TO CONSULTANTS
PRIOR TO CONSTRUCTION.
· ALL CONSTRUCTION WASTE MATERIALS &
CARDBOARD MUST BE RECYCLED.
· BASE BUILDING SLAB SHALL BE BROUGHT BACK TO
SMOOTH TROWELED SINGLE PLAIN CONCRETE.
ALL REDUNDANT WIRING TO BE REMOVED BY ELECTRICAL
CONTRACTOR AS REQ'D. (TYP.)
EXISTING TRANSFORMERS AND ELECTRICAL
PANELS TO REMAIN. REFER TO ELECTRICAL
EXISTING FLOOR FINISH AND RUBBER BASE AT
STORAGE ROOM TO BE REMOVED. PATCH, REPAIR
AND PREP FLOOR TO RECEIVE NEW FLOOR FINISH
AS REQUIRED
EXISTING PARTITION TO REMAIN. REMOVE
ALL EQUIPMENT, FIXTURE AND MILLWORK
EXISTING DOOR, FRAME AND DOOR HARDWARE
TO REMAIN
EXISTING FLOOR FINISHES & BASEBOARDS
TO BE REMOVED. G.C. TO MAKE GOOD
SURROUNDING SURFACES & LEVEL FLOOR
TO RECEIVE NEW FLOOR FINISHES AS PER
DWG. A2.4
EXISTING DEMISING WALLS -
G.C. TO ENSURE ALL REQUIRED FIRE RATINGS ARE
MAINTAINED (TYPICAL BOTH SIDES)
EXISTING BULKHEAD CEILING, ALL TRACK,
RECESSED LIGHTING AND PENDANT FIXTURE
TO BE REMOVED UNLESS OTHERWISE NOTED.
REFER TO ELECTRICAL DRAWINGS AND DWG.
A6.0 FOR ADDITIONAL DEMOLITION SCOPE ON
REFLECTED CEILING PLAN.
REMOVE ALL EQUIPMENT, SIGNAGE AND FIXTURES
THROUGHOUT. REMAINING SURFACES TO BE
MADE READY FOR NEW FINISHES AND STORE
FIXTURES AS PER DWG. A2.2
EXISTING ROUND COLUMN CLADDING TO BE
REMOVED
ALL CORING / TRENCHING OF SLAB MUST BE IN
ACCORDANCE TO THE GUILDLINES ISSUED BY
LANDLORD, AND LOCATIONS MUST BE APPROVED BY
STRUCTURAL ENGINEER. SCAN SLAB PRIOR TO CORING
AND TRENCHING. NOTIFY MALL OPERATIONS PRIOR TO
WORK.
EXISTING POWER POLE TO BE REMOVED, TYPICAL.
REFER TO ELECTRICAL
REMOVE ALL SHELVING THROUGHOUT. PATCH
AND REPAIR GWB SURFACES AS REQUIRED FOR
NEW FINISHES AND NEW SHELVING.
EXISTING ELECTRICAL DEVICES IN THE STORAGE
AREA TO REMAIN. UNLESS OTHERWISE NOTES.
EXISTING POWER POLE AND ASSOCIATED CABLES
TO BE REMOVED, TYPICAL. REFER TO ELECTRICAL
CHAT'R FIXTURE TO BE REMOVED AND STORED
FOR REINSTALLATION
FIXTURE TO BE REMOVED AND STORED FOR
REINSTALLATION
APPLE FIXTURE TO BE REMOVED
AND STORED FOR REINSTALLATION
SAMSUNG FIXTURE TO BE REMOVED AND STORED
FOR REINSTALLATION
GOOGLE FIXTURE TO BE REMOVED AND STORED
FOR REINSTALLATION
EXISTING SECURITY CAMERA RELOCATE TO
COORDINATE WITH FIXTURE
REFER TO ELECTRICAL DWGS.
EXISTING FIRE EXTINGUISHER AND ALARM
KEYPAD TO TO REMAIN
6
'
-
1
"
2
'
-
1
"
7'-9 1/2"
2'-6
"
3'-7 1/2"
6
'
-
4
1
/
2
"
72°
4'-8"
3
'-
8
"
7
'-
1
"
6'-9
"
8
1
/
2
"
7'-5
1
/2
"
COORDINATE ENTRY ACCESS WITH LL HOARDING.
PROVIDE SHOE MATS AND WIPES TO PREVENT DUST AND
DIRT FROM ENTERING MALL SPACE.
G.C. TO ENSURE NEW CONCRETE
TOPPING WITHIN TENANT SPACE
LINE WITH MALL FEATHER POINT
6
"
6"
6"
6
1
/
2
"
6"
6
"
2'-0
"
1. CONTRACTOR MUST VISIT THE SITE, EXAMINE ALL EXISTING CONDITIONS, TENDER DOCUMENTS,
DRAWINGS AND SPECIFICATIONS, AND MAKE NECESSARY ALLOWANCES IN THE TENDER PRICE FOR
REMOVAL.
2. REPORT ANY DISCREPANCIES IN WRITING TO THE DESIGNER IMMEDIATELY.
3. ALL WORK SHALL CONFORM TO ALL LOCAL, CITY, PROVINCIAL CODES AND BY-LAWS IN THE
JURISDICTION WHERE THE PROJECT IS LOCATED.
4. AS OUTLINED AND INDICATED ON PLANS, REMOVE ALL LIGHT FIXTURES, PERIMETER WALL
TREATMENTS, HARDWARE, CAP OFF WATER DRAINS AND VENT PIPES AS REQUIRED, DISCONNECT
AND SAFELY CAP ELECTRICAL FIXTURES/EQUIPMENT AND WIRING AS REQUIRED.
5. REMOVE AND SAFELY CAP ALL REDUNDANT EXISTING WIRING AND ELECTRICAL FIXTURES.
6. OUTLETS NOT BEING USED TO BE DISCONNECTED AND CAPPED OFF.
7. ALL PLUMBING, ELECTRICAL, AND MECHANICAL WORK TO FOLLOW UNDER SEPARATE PERMIT;
EXISTING SITE AND SITE CONDITIONS TO BE REVIEWED THOROUGHLY PRIOR TO WORK BEING
STARTED.
8. THESE DRAWINGS HAVE BEEN GENERATED FROM PREVIOUS EXISTING DRAWINGS AND SITE
DIMENSIONS - CONTRACTOR MUST VERIFY ALL DIMENSIONS AND LAYOUTS PER THESE DRAWINGS,
AND NOTIFY THE CONSULTANTS OF ANY DISCREPANCIES.
9. ALL ABOVE WORK NOTED AS WELL AS WORK DOCUMENTED TO BE COMPLETED PER LOCAL CODES
AND BYLAWS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING EXISTING LL DEMISING CAPS IN GOOD
CONDITION ONCE CONSTRUCTION IS COMPLETE. GC TO REPLACE WITH NEW SHOULD CAP BE
DAMAGED.
11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOUR, MATERIALS,
AND SUPERVISION NECESSARY TO COMPLETE THE WORK AS SHOWN OR NOTED ON THE
DRAWINGS. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A
LICENSED CONTRACTOR IN A WORKMANLIKE MANNER. SAID CONTRACTOR SHALL MEET ALL
REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND GOVERNING AUTHORITIES. THE
CONTRACTOR SHALL KEEP ALL AREAS OF WORK CLEAN FROM DEBRIS AT ALL TIMES, AND SAID
AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY. CONTRACTOR SHALL
GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT
LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE
COMPLETED WITHOUT ADDITIONAL CHARGE, AND SHALL INCLUDE REPLACEMENT OR REPAIR OF
ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY.
GENERAL DEMOLITION NOTES
AS PER OXFORD LANDLORD DESIGN GUIDELINES.
HOARDING NOTE
AS PER OXFORD LANDLORD DESIGN GUIDELINES.
HOARDING NOTE
DEMOLITION PLAN
A2.0
DG
AS SHOWN
SCALE:
1
DEMOLITION PLAN
3/8" = 1'-0"
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
NORTH
A
FE
12'-4"
8'-0
"4
8'-1
0"
23
'-9
"
1
7
'
-
3
"
15'-0"
2
3
'
-
3
1
/
2
"
7"
1
'
-
6
"
2
A4.0
2
A4.1
1
A4.1
1
A4.0
3
A
3
.
0
STORAGE
( B.O.H. )
110 SQ.FT.
RETAIL
840 SQ.FT.
EXISTING PARTITION TO REMAIN
ALL DIMENSIONS TO BE CONFIRMED ON SITE
PRIOR TO CONSTRUCTION
REFER TO DWG. A4.0 FOR STOREFRONT
DETAILS AND SECTIONS
ALL DIMENSIONS & SITE CONDITIONS TO BE
VERIFIED BY GC
WHERE APPLICABLE SCAN SLAB PRIOR TO
ANY TRENCHING OR CORING AND NOTIFY
MALL OPERATIONS PRIOR TO WORK
EXISTING DEMISING WALLS -
G.C. TO ENSURE ALL REQUIRED FIRE RATINGS ARE
MAINTAINED (TYPICAL BOTH SIDES)
EXISTING DEMISING CAP TO REMAIN, TYPICAL
BOTH SIDES. PATCH AND REPAIR AS REQUIRED
TO MATCH EXISTING.
G.C. TO PROVIDE STEEL STUD FURRED OUT
PARTITION C/W PLYWOOD SHEATHING ON
EXTERIOR SURFACE. MILLWORK CONTRACTOR TO
PROVIDE MILLWORK FINISH TO BE SECURED TO
PARTITION. REFER TO WALL PARTITION
SCHEDULE AND DWG. A3.0 FOR DETAILS.
LEASE LINE
NEW STOREFRONT 1/2" TEMPERED GLASS C/W
U-CHANNEL AT T/O GLASS TO BE SECURELY
FASTENED TO STRUCTURAL SUPPORT WITHIN
BULKHEAD. APPLY VINYL STICKER AT THE TOP OF
GLASS. OPAQUE PINK TO MATCH PT-2 TO RUN
CLEAR OVER A 2'-0" LENGTH.
NEW GRILLE ENCLOSURE DOOR C/W CONCEALED
HINGE AND TOUCH LATCH HARDWARE FOR
SEAMLESS APPEARANCE IN WALL.
INSTALL NEW LOCK WITH MASTER KEY SETUP BY
HEAD OFFICE. INSTALL LOCK ON POCKET PANEL
DOOR, TO BE KEYED ALIKE WITH CASH COUNTER
DRAWERS IF POSSIBLE.
EXISTING FIRE HOSE CABINET TO REMAIN
1'-6 1/2"
1
'
-
6
"
4
'
-
7
"
NEW INTERIOR PARTITION,
REFER TO WALL PARTITION SCHEDULE
1'-0"
2'-2
"
NEW GRILLE ENCLOSURE PARTITION.
REFER TO WALL PARTITION SCHEDULE
D101
D102
6
'-
1
1
/
2
"
1
'-
6
"
EXISTING DOOR , FRAME AND HARDWARE TO REMAIN.
DOOR AND FRAME TO RECEIVE NEW PAINT.
REFER TO DWG.2.3
2'-0"
2'-0
"
NEW GRILLE DOOR AND TRACK
ABOVE, TYPICAL.
13'-0"
NEW INTERIOR PARTITION.
REFER TO WALL PARTITION SCHEDULE
G.C. TO PROVIDE GWB, PAINTED, FROM 8'-0" A.F.F.
TO 12'-0" A.F.F., TYPICAL
EXISTING COLUMN TO BE RECLADDED WITH METAL
STUDS AND GWB. REFER TO WALL PARTITION
SCHEDULE FOR WALL TYPE.
2
'-
0
"
2
'
-
5
1
/
2
"
D103
NEW 1'-0" W x 7'-0" H SERVICE DOOR C/W CONCEALED
HINGE AND TOUCH LATCH HARDWARE FLUSHED FOR
SEAMLESS APPEARANCE IN WALL.
WOOD VENEER ON MDF
3
'
-
0
"
3
'
-
0
"
2
'-
0
"
W-1W-1
W-1
W-1
W-1
W-1
W-4
W-5
W-4
W-5
W-5
PROVIDE BLOCKING TO SUPPORT
CABINET HINGES
GC TO SUBMIT ENGINEER SIGNED AND
SEALED SHOP DRAWINGS FOR REVIEW. ALL
RECESSED PINS TO HAVE SPRING CORDED
COVERS.
SLIDING GRILLES - SPEC. BELOW:
INSTALL NEW GRILLE DYNAFLAIR
MODEL: ELEGANCE C/W EGRESS DOOR ON
SEPARATE HINGE EQUIPPED WITH 1"
MORTISE THUMB TURN ACTUATOR ON INSIDE
ONLY.
- DOOR MUST BE ABLE TO LOCK FROM
THE OUTSIDE
- INSTALL TOP & BOTTOM LOCKING PINS
AT BOTH ENDS OF THE GRILLE DOOR
SO THE POCKET DOOR PANEL REMAINS
CLOSED ONCE THE GRILLE DOOR HAS
BEEN PULLED OUT
- INSTALL NEW LOCK WITH MASTER KEY
SET UP BY HEAD OFFICE
- INSTALL LOCK ON POCKET PANEL DOOR
TO BE KEYED ALIKE WITH CASH
COUNTER DRAWERS IF POSSIBLE
GWB BULKHEAD ABOVE
PROVIDE RECESSED CONNECTION BOX
FOR MONITOR ABOVE BANQUETTE
EX-D100
EX-D100
D101
D103
D102
G.C. TO PROVIDE 4'-0" x 8'-0" x 3/4" THK.
FIRE-TREATED PLYWOOD BACKING FOR
I.T. EQUIPMENT AND RACKING
LOCATION OF EXISTING ELECTRICAL PANEL
REFER TO ELECTRICAL FOR DETAILS
5
"
7'-1 1/2"
2'-0
"
1
A3.0
2
A3.0
3
A4.1
SYMBOL WALL TYPE DESCRIPTION
EXISTING DEMISING WALL PARTITION TO REMAIN
· PATCH AND REPAIR AS REQUIRED FOR NEW WALL FINISHES
NEW INTERIOR PARTITION 1 (TO U/S OF NEW CEILING)
· 1/2" TYPE 'X' GYPSUM BOARD BOTH SIDES
· 3 5/8" STEEL STUDS @ 16" O.C.
· TYPE 'S' DRYWALL SCREWS SPACED 7" O.C.
· TAPE, SPACKLE AND SAND, READY TO RECEIVE NEW FINISH.
NEW GRILLE ENCLOSURE / MILLWORK PARTITION
· 3/4" MDF PANEL C/W FINISH WD-1 (BY MILLWORK CONTRACTOR)
· 3/4" PLYWOOD SHEETING
· 3 5/8" STEEL STUDS @16" O.C.
· MDF MILLWORK TO SECURE TO PARTITION AS REQUIRED.
REFER TO DWG. A3.0 FOR MILLWORK DETAILS
NEW FURRED OUT PARTITION (TO 12'-0" A.F.F. / GWB BULKHEAD)
· 1/2" TYPE 'X' GYPSUM BOARD ONE SIDE ONLY
· 3 5/8" STEEL STUDS @ 16" O.C.
· PRE-FINISHED MILLWORK PANELS SUPPLIED BY MILLWORK CONTRACTOR
MOUNTED ON EXTERIOR SIDE ONLY
WALL PARTITION SCHEDULE
1. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE AND EXAMINE ALL ASPECTS
THOROUGHLY PRIOR TO SUBMITTING A BID, AND TO UNDERSTAND ALL ASPECTS OF THE EXISTING
SITE AND THE SCOPE OF WORK REQUIRED TO COMPLETE THE SPACE, READY TO OPEN THE
DOORS FOR BUSINESS. ALSO TO EXAMINE THE EXISTING CONSTRUCTION TO DETERMINE HOW TO
BEST PROCEED WITH DEMOLITION AS WELL AS THE TYPES OF MATERIALS BEING DEMOLISHED.
2. PATCH AND REPAIR AS NECESSARY ALL WALLS, CEILING, FLOORING ETC. TO REMAIN READY TO
RECEIVE FINAL NEW FINISHES. MAINTAIN ALL EXISTING FIRE RATINGS AND SEPARATIONS. PATCH,
REPAIR & MAKE GOOD AS REQUIRED TO ENSURE THAT FIRE RESISTANCE RATINGS ARE NOT
COMPROMISED.
3. CONTRACTOR TO PROVIDE BLOCKING IN WALLS AS NECESSARY TO SUPPORT ALL NEW FINISHES
AND MILLWORK ITEMS. REFER TO ELEVATIONS AND ALL OTHER DRAWINGS TO ESTABLISH ALL
LOCATIONS. SUBSTANTIAL COORDINATION IS REQUIRED TO FOLLOW THE DESIGN INTENT IN
CONTEXT WITH THE EXISTING FEATURES, BASED ALSO ON NOT HAVING EXISTING AS-BUILT
DRAWINGS TO REFER TO WITH RESPECT TO ASPECTS SUCH AS ELECTRICAL AND STRUCTURAL
ASPECTS ABOVE, BELOW, AND WITHIN THE SPACES REQUIRING RENOVATION.
4. FIT TEMPORARY HOARDING TO STOREFRONT, AS PER MALL STANDARDS AND POLICIES FOR
PUBLIC SAFETY AND PRIVACY REGULATIONS
5. NOISY WORK TO BE PERFORMED IN ACCORDANCE WITH THE MALL'S HOURS SET FORTH IN RULES
& REGULATIONS.
6. ALL MATERIALS TO MEET FLAME SPREAD RATINGS REQUIREMENTS OF AUTHORITIES HAVING
JURISDICTION.
7. ALL ROOF-MOUNTED EQUIPMENT TO BE INSTALLED ON PLATFORMS TO LANDLORD'S DETAIL AND
LOCATION AT THE TENANT'S EXPENSE.
8. NEITHER THE TENANT NOR THE TENANT'S CONTRACTOR'S ARE PERMITTED TO CUT ROOF
OPENINGS. SUCH WORK SHALL BE INITIATED & EXECUTED BY THE LANDLORD AT THE TENANT'S
EXPENSE.
9. CONTRACTOR TO ENSURE THAT ALL FIXTURES, PARTITIONS AND INTERIOR ELEMENTS ARE
COMPLIANT WITH CITY'S BUILDING CODE SEISMIC RESTRAINT REQUIREMENTS
10. DURING THE TENDER PERIOD, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL
SUBTRADES TO VERIFY ALL DIMENSIONS AND CONDITIONS AS SHOWN ON THESE DRAWINGS WITH
ACTUAL SITE CONDITIONS. ANY DISCREPANCIES TO BE REPORTED TO THE CONSULTANTS, PRIOR
TO COMMENCEMENT OF CONSTRUCTION AND/OR INSTALLATION. ANY EXTRA WHICH A VISIT ON
SITE WOULD HAVE MADE APPARENT, WILL NOT BE ALLOWED.
11. ALL ELECTRICAL MATERIAL AND HARDWARE AS SPECIFIED ON DRAWINGS ARE TO BE SUPPLIED
AND INSTALLED BY CONTRACTOR.
12. PATCH AND REPAIR CONCRETE SLAB THROUGHOUT AS NECESSARY, READY TO RECEIVE NEW
FINISHES. CONTRACTOR TO ENSURE ALL EXISTING WALLS AND FLOORS ARE PROPERLY PREPARED
FOR INSTALLATION OF SPECIFIED MATERIALS. PATCH & REPAIR AS NECESSARY, READ TO RECEIVE
NEW FINISH (CARPET, PAINT, LAMINATE, RESILIENT FLOORING, ETC.)
GENERAL CONSTRUCTION NOTES
NEW INTERIOR PARTITION 2 (TO U/S OF NEW CEILING)
· 1/2" TYPE 'X' GYPSUM BOARD BOTH SIDES
· 6" STEEL STUDS @ 16" O.C.
· TYPE 'S' DRYWALL SCREWS SPACED 7" O.C.
· TAPE, SPACKLE AND SAND, READY TO RECEIVE NEW FINISH.
W-1
W-2
W-3
W-4
W-5
CONSTRUCTION PLAN
A2.1
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
1
CONSTRUCTION PLAN
3/8" = 1'-0"
NORTH
A
FE
2'-1
1"
4'-0
"
2"
4'-0
"9
"4
'-0
"4
'-0
"4
'-0
"4
'-0
"1
'-8
"2
'-2
"8
"3
'-1
0"
4"
6'-0
"6
"5
'-1
0"
5'-10 1/2"
2'-0
"4
'-1
0"
4'-8" 3'-4" 4'-8"
3'-4"
4'-0
"4
'-0
"
7
"
4
'
-
0
"
4
"
6
'
-
0
"
8
1
/
2
"
4
'
-
7
"
S-6
F-7
F-5
S-6
FUR-1
M-4
M-7
M-3
M-2
F-3
F-1
D-1
2'-0
"
12'-4"
8'-0
"4
8'-1
0"
23
'-9
"
1
7
'
-
3
1
/
2
"
NOTE:
NO VISIBLE WIRE, CONDUIT OR FASTENERS
PERMITTED.
2'-0"
2
A4.0
2
A4.1
1
A4.1
1
A4.0
3
A
3
.
0
WOOD SHELVING C/W WALL-MOUNTED METAL
TWIN SLOT UPRIGHTS AND BRACKETS. 96" HIGH x
14" DEEP WITH 5/8" MDF BULLNOSE SHELVES.
PROVIDE 5 SHELVES PER SHELVING UNIT AND
PLYWOOD BACKING.
S-4
7'-1 1/2"
M-6
4'-0
"
F-6
2"
4'-0
"8
"4
'-0
"
M-8
D-2
1
'
-
1
"
M-8
D-2
3'-4"
FUR-1
FUR-2
FUR-2
FUR-1
FUR-1
FUR-2
FUR-2
S-6
S-6
S-6
4'-1
1"
5'-9
"1
0'-0
"8
'-0
"
4'-0"
S-6
S-6
S-6
F-4
F-2
5'-1" 2'-6"
3
'
-
0
"
3
'
-
0
"
2
'
-
6
"
4
'
-
0
"
2
'-
6
"
S-2
M-1
5
'
-
3
1
/
2
"
5
'-
5
1
/
2
"
3
'
-
3
"
3
'
-
3
"
S-3
11
"
D-3
S-4
S-3
1
A3.0
2
A3.0
3
A4.1
NEW MILLWORK SCHEDULE
NO. DESCRIPTION:
CARRIER WALL DETAILM-1
QUANTITY:
1
SM PHONE DISPLAYM-22
LG PHONE DISPLAYM-31
POS CASH FIXTUREM-41
ACCESSORIES DISPLAYM-55
BANQUETTEM-61
OTTOMANM-71
TV FIXTUREM-8
2
NEW FURNITURE SCHEDULE
NO. DESCRIPTION:
COUNTER HEIGHT STOOL
TBD
FUR-1
QUANTITY:
4
TABLE HEIGHT STOOL
TBD
4
SCREEN AT ENTRY
PORTRAIT BY CLIENT
D-11
SCREEN ON
LANDSCAPE BY CLIENT
D-22
M-8
NEW DIGITAL SCHEDULE
NO. DESCRIPTION:
CARRIER LOGOS COLLAGE
[REFER TO FA FOR MORE INFO]
S-1
QUANTITY:
1 GROUPING
VINYL ON GLASS
S-2
1
VINYL DECALS ON GLASS
[REFER TO FA FOR MORE INFO]
S-3
1 GROUPING
ACCESSORIES SIGNAGE BACKLIT GRAPHIC
S-4
5
BACK WALL BACKLIT GRAPHIC
S-5
1
FUR-2
EXISTING FIXTURES SCHEDULE
NO. DESCRIPTION:
SAMSUNGF-1
QUANTITY:
1
APPLEF-2
LGF-3
1
GOOGLEF-4
1
CHATRF-5
ROGERSF-6
1
BELLF-7
1
1
1
S-6
STOREFRONT SIGN 1
REFER TO SEPARATE MILLWORK PACKAGE FOR MORE INFORMATION.
1. REFER TO MILLWORK DRAWING PACKAGE, UNDER SEPARATE COVER, IN CONJUNCTION WITH THIS PACKAGE.
2. ALL FIXTURES ARE TO BE PROVIDED AND INSTALLED BY THE MILLWORK CONTRACTOR UNLESS OTHERWISE
NOTED.
3. ALL FURNITURE ITEMS ARE TO BE SUPPLIED BY CLIENT UNLESS OTHERWISE NOTED.
4. ALL FURNITURE ITEMS ARE TO BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR.
5. ALL EQUIPMENT AND TV TO BE SUPPLIED BY OWNER AND INSTALLED BY GC.
GENERAL NOTES
NOTES:
NOTES:
NOTES:
NOTES:
SUPPLIED BY OTHERS
C/W POWER AND DATA
SUPPLIED BY OTHERS
C/W POWER AND DATA
SUPPLIED BY OTHERS
C/W POWER AND DATA
SUPPLIED BY OTHERS
C/W POWER AND DATA
SUPPLIED BY OTHERS
SUPPLIED BY OTHERS
SUPPLIED BY OTHERS
MILLWORK CONTRACTOR
MILLWORK CONTRACTOR
MILLWORK CONTRACTOR
MILLWORK CONTRACTOR
MILLWORK CONTRACTOR. NO PAC POLE,
POWER TO FED FROM BASE OF MILLWORK
MILLWORK CONTRACTOR. NO PAC POLE,
POWER TO FED FROM BASE OF MILLWORK
MILLWORK CONTRACTOR. NO PAC POLE,
POWER TO FED FROM BASE OF MILLWORK
MILLWORK CONTRACTOR
SUPPLIED BY OTHERS
SUPPLIED BY OTHERS
SAMSUNG SCREEN AT ENTRY
PORTRAIT BY CLIENT
D-31
SUPPLIED BY OTHERS
C/W POWER AND DATA
FIXTURE PLAN
A2.2
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
1
FIXTURE PLAN
3/8" = 1'-0"
NORTH
7'-6"
7'-5
1
/2
"
2'-0
"3
'-6
"3
'-6
"
4'-6
1
/2
"4
'-4
"3
'-1
1 1
/2
"2
'-7
"
ALL EXISTING WALL OUTLETS
TO REMAIN WHERE POSSIBLE.
RELOCATE AS NEEDED TO
SUIT NEW LAYOUT.
SCAN SLAB PRIOR TRENCHING
OR CORING. NOTIFY MALL
OPERATIONS PRIOR TO WORK.
POWER & DATA RECEPTACLES
FOR EXPERIENCE TABLE F1A.
MOUNT TO UNDERSIDE OF TABLE.
SUPPLY POWER & DATA FOR
EXPERIENCE TABLE THROUGH
CONDUIT, TRENCH AND FLOOR BOX.
CONDUITS TO CEILING SPACE, TYP.
REFER TO ELECTRICAL
EXISTING ELECTRICAL PANELS TO
REMAIN. REFER TO ELECTRICAL
EXISTING TRANSFORMER AT ABOVE
1
'
-
6
"
1'-6 1/2"
1
'
-
6
"
4
'
-
7
"
1'-0"
2'-2
"
3'-6
"4
'-2
"4
'-2
"5
'-6
"3
'-8
"4
'-9
"
POWER, PHONE & DATA
RECEPTACLES FOR CASH TABLE F1.
MOUNT TO UNDERSIDE OF TABLE.
17
'-0
"
POWER, PHONE & DATA
RECEPTACLES FOR PHONE TABLE
F1N. MOUNT TO UNDERSIDE OF
TABLE.
6'-9
"
1
6
'
-
7
"
SUPPLY POWER & DATA
FOR CASH TABLE
THROUGH CONDUIT,
TRENCH AND FLOOR BOX.
7'-6"
2'-5
"1
6'-7
"1
0'-1
"
6'-0"
POWER CONNECTION TO TIME
CLOCK FOR SIGNAGE ABOVE
6
'-
1
1
/
2
"
1
'-
6
"
2'-0"
2'-0
"
13'-0"
2
'-
0
"
2
'
-
5
1
/
2
"
3
'
-
0
"
3
'
-
0
"
2
'-
0
"
4'-2
"
5'-8
"
4
'
-
9
1
/
2
"
4
'
-
2
1
/
2
"
6
'
-
8
1
/
2
"
6
'
-
6
1
/
2
"
6
'-
7
"
EXISTINGTEL/COMMUNICATION PANEL
TO REMAIN
2'-8
1
/2
"
SUPPLY POWER & DATA FOR CASH
TABLE THROUGH CONDUIT, TRENCH
AND FLOOR BOX.
EXISITNG ELECTRICAL
DEVICES IN STORE ROOM TO
REMAIN, UNLESS NOTED
OTHERWISE.
4'-0
1
/2
"
1'-9"
5
"
1. ALL CONSTRUCTION AND ELECTRICAL OUTLET WIRING TO COMPLY WITH
LOCAL BUILDING CODES AND OTHER APPLICABLE REGULATIONS TO
REDUCE RISK OF FIRE AND ELECTRICAL HAZARDS.
2. FOR FINAL ELECTRICAL CONNECTIONS REFER TO ELECTRICAL DRAWINGS
AND SPECIFICATIONS.
3. ALL ELECTRICAL MATERIAL AND HARDWARE AS SPECIFIED ON DRAWINGS
ARE TO BE SUPPLIED AND INSTALLED BY CONTRACTOR.
4. FOR DIMENSIONAL PURPOSES ONLY, COORDINATE WITH ELECTRICAL
ENGINEERING DRAWINGS.
5. ALL OUTLETS TO BE BLACK WITH STAINLESS STEEL COVER PLATES UNLESS
LOCATED WITHIN MILLWORK.
6. CONTRACTOR TO VERIFY EXISTING ELECTRICAL OUTLETS WITHIN SPACE
AND RELOCATE/ ADD NEW OUTLETS AS SPECIFIED ON DRAWING. REWIRE
EXISTING ELECTRICAL OUTLETS TO NEW POWER SOURCE AS REQUIRED.
7. ALL EXISTING AND NEW SWITCH PLATES TO BE REPLACED WITH STAINLESS
STEEL PLATES IN RETAIL SPACE. CONTRACTOR TO VERIFY QUANTITY ON
SITE.
8. STOREFRONT SIGNAGE TO BE ELECTRIFIED/ HARD-WIRED TO BE
CONTROLLED BY 24 HOUR TIMER AND OPERATED DURING THE HOURS
SPECIFIED BY LANDLORD
9. REFER TO ENGINEERS DRAWINGS FOR EMERGENCY LIGHTS, EXIT SIGNS
AND REQUIRED FIRE EXTINGUISHER CABINETS.
10. GENERAL CONTRACTOR SHALL COORDINATE GANG BOX AND JUNCTION
BOX LOCATIONS AND REQUIREMENTS WITH FIXTURE/MILLWORK VENDOR
PRIOR TO INSTALLATION.
11. GENERAL CONTRACTOR TO COORDINATE ALL HOLES AND GROMMET
LOCATIONS IN FIXTURES/MILLWORK WITH CLIENT APPOINTED
REPRESENTATIVE/PROJECT MANAGER.
12. PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH.
13. IN EXISTING SPACES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT
THE SITE AND VERIFY ALL EXISTING ELECTRICAL AND DATA LINES.
14. ALL REDUNDANT EXISTING WIRING TO BE REMOVED AND DISCONNECTED
AT SOURCE (I.E. ELECTRICAL PANEL OR JUNCTION BOX).
15. EXISTING OUTLETS TO BE REUSED IF FALL IN CLOSE PROXIMITY TO NEW
OUTLETS SHOWN ON PLAN - REWIRE TO NEW POWER SOURCE AS
REQUIRED.
16. ALL OUTLETS ON COLUMNS MUST BE FLUSH WITH FINAL FINISH - COLUMNS
MUST BE FURRED OUT TO HOUSE J-BOXES/CONDUIT AS REQUIRED.
17. PROVIDE SEISMIC RESTRAINT TO ALL EQUIPMENT AND ALL FIXTURES AS
REQUIRED.
18. G.C. TO CONFIRM THAT LANDLORD WILL SUPPLY INCOMING ELECTRICAL
SERVICE -600V, 3 PHASE, 3 WIRE ALTERNATING CURRENT, FUSED
DISCONNECT SWITCH, AND PANEL. CONTRACTOR TO PROVIDE SPLITTER
FOR HVAC EMERGENCY LOCAL REGULATIONS.
19. ALL ELECTRICAL P/V/D MOUNTED AT 12" A.F.F. UNLESS OTHERWISE NOTED.
MECHANICAL NOTESELECTRICAL LEGEND
SYMBOL DESCRIPTION
FOURPLEX ELECTRICAL RECEPTACLE
· WALL-MOUNTED OUTLET
ELECTRICAL OUTLET MOUNTED IN MILLWORK
· MOUNTING HEIGHT TO BE DETERMINED BY MILLWORK CONTRACTOR
VOICE/DATA OUTLET FOR FAX/PRINTER
GENERAL NOTES
EXISTING ELECTRICAL RECEPTACLE TO REMAIN
· CONTRACTOR TO ENSURE IN GOOD WORKING ORDER.
1/2" CONDUIT FOR COMMUNICATION WIRING
· CONDUIT IN WALL
· TO CONTAIN PULL STRING TO BACK ROOM
DUPLEX ELECTRICAL RECEPTACLE
· WALL-MOUNTED OUTLET
· REFER TO ELECTRICAL ENGINEER'S DRAWINGS AND SPECIFICATIONS.
· ALL OUTLETS TO BE BLACK WITH STAINLESS STEEL COVER PLATES
UNLESS LOCATED WITHIN MILLWORK
· ALL OTHER EXISTING OUTLETS TO BE REPLACED OR REMOVED AS
REQUIRED
CEILING MTD. POWER DATA AND COMMUNICATION OUTLETS
DATA OUTLET
TELEPHONE OUTLET
SINGLE ELECTRICAL WALL OUTLET
NETWORK PRINTER CABLE
· TO BE RUN BACK TO BACK R00M
PANEL NOTES
CAT 5E GRADE DATA CABLING ONLY FOR BOTH DATA AND VOICE. AS FOLLOWS:
· ONE (1) CABLE PER POS TERMINAL STATION
· TWO (2) CABLES FOR THE FACIMILIE/PRINTER
· ONE (1) CABLE FOR EACH TRANSELECT MACHINE
· ONE (1) CABLE FOR EACH PHYSICAL TELEPHONE.
· COMFIRM (2) TELEPHONES PER STORE, AND THEIR LOCATION WITH
TENANT
· ALL CABLES ARE TO BE PULLED BACK TO THE COMMUNICATIONS PANEL
LOCATION
PANEL, CIRCUIT BREAKER INFORMATION:
· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR TENANT'S
COMMUNICATION PANEL
· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR EACH POS TERMINAL,
CONSISTING OF 1 COMPUTER, MONITER, AND THERMAL RECEIPT PRINTER
· TELEPHONES AND TRANSELECT MACHINE CAN SHARE THE CIRCUIT WITH
THE POS.
· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR THE FACSIMILE/
PRINTER TERMINAL STATION.
PANEL NOTE:
· COMMUNICATION PANEL TO BE INSTALLED IN CLOSE PROXIMITY TO
ELECTRICAL PANEL, TERMINAL STATION.
CAT-5 DATA DROP
TRENCH, REFER TO DETAIL 2/A2.4
FLOOR BOX, REFER TO ELECTRICAL
* G.C. TO COORDINATE ALL MECHANICAL AND ELECTRICAL REQUIREMENTS
WITH SNC LAVALIN.
* G.C. TO COORDINATE ALL MECHANICAL AND ELECTRICAL REQUIREMENTS
WITH SNC LAVALIN.
EXISTING
TOPPING SLAB
EXISTING
STRUCTURAL SLAB
1" DIAMETER CONDUIT. REFER TO
POWER & DATA PLAN FOR NUMBER
OF CONDUIT REQUIRED.
2" 2" 2"
8"
1"1"
POWER & DATA
PLAN
A2.4
DG
AS SHOWN
SCALE:
1
POWER & DATA PLAN
3/8" = 1'-0"
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
2
TRENCH DETAIL
3" = 1'-0"
NORTH
4" S.S. GLAZING CHANNEL
1/2" TEMPERED GLASS, PROVIDE
ENGINEER SIGNED AND SEALED SHOP
DRAWINGS
6" S.S. GLAZING CHANNEL
GWB BULKHEAD AT 11'-0" AFF,
PAINTED PT-2
4" HIGH MDF LIP,
PAINTED TO MATCH PT-2
1/2" ALUMINUM REVEAL
NEW STOREFRONT MDF
BULKHEAD TO RECEIVE NEW
FINISH WD-1
MAKE GOOD CONNECTION WITH
LANDLORD BULKHEAD, SIGNED
AND SEALED ENGINEER SHOP
DRAWING FOR GLAZING AND
SUPPORT
1/2" ALUMINUM REVEAL
3'-2"
4"
3'-6"
10'-6" A
FF
FINISHED FLOOR
G.C. TO VERIFY DIMENSIONS OF LCD
MONITORS PRIOR TO CONSTRUCTING
OPENING; ADJUST OPENING TO
ENSURE 1/2" GAP AROUND LCD
MONITORS - ALL SIDES
G.C. TO COORDINATE FINAL
EQUIPMENT & RECESS SIZE W/
CLIENT
LC
D N
IC
HE
, D
IM
T
BD
LCD MONITOR TO BE RECESSED INTO
PARTITION. CONTRACTOR TO PROVIDE
MOUNTING HARDWARE AS REQUIRED.
CUT HOLES IN BACK FOR WIRE ACCESS
AND VENTIN
CONTRACTOR TO PROVIDE 1/2" PLYWOOD
BLOCKING BEHIND DRYWALL TO SECURE
LCD. DRYWALL TO BE PAINTED BLACK
ALL SIDES OF RECESS TO BE PAINTED
BLACK
BLACK PAINT SPEC: BENJAMIN MOORE
'UNIVERSAL BLACK' 2118-10
DIM
EN
SIO
N T
BD
RETAIL AREA SIDE
PROVIDE SLOTS FOR AIR CIRCULATION
BEHIND LCD, TOP & BOTTOM TYP.
9 3/4"
PROVIDE WOOD BLOCKING
FINISHED FLOOR
NEW 6" H BREAK METAL BASEBOARD
WITH BRUSHED STAINLESS STEEL
LOOK
5"
MDF MILLWORK FINISH WD-1
MDF MILLWORK FINISH WD-1
3 1/2"
BULKHEAD
SUPPORT
BY CONTRACTOR
SUSPENDED BULKHEAD,
5/8" GWB OVER METAL
STUD FRAMING @ 16" O.C.
BY GENERAL CONTRACTOR
C/W FINISH ON
ALL EXTERIOR SIDES
U/S OF EXISTING CEILING
10
'-6
" A
FF
T
O U
/S
OF
N
EW
C
EN
TE
R B
UL
KH
EA
D
3 1/2"
VA
RIE
S
TOP OF FINISHED
FLOOR
12" MIN.
PT-1
G.C. TO PROVIDE
ENGINEER SIGNED AND
SEALED SHOP DRAWINGS
C/W SCHEDULES FOR ALL
STRUCTRUAL SUPPORTS
OF BULKHEAD
6'-0"
12" MIN.
2'-8" 8" 3'-10"
G.C. TO COORDINATE
LOCATION OF HVAC SYSTEM
WITHIN BULKHEAD
9'-6
" A
FF
(N
.T
.S
.) T
O U
/S
OF
N
EW
P
EN
DA
NT
F
IX
TU
RE
1
2'-0
" A
FF
T
O T
/O
E
XIS
TIN
G G
WB
W
AL
L
1'-1
"
1
0'-6
" A
FF
T
O U
/S
O
F B
UL
KH
EA
D8
"
5/8
"
6"
8"
5/8" THK. GWB LIGHT COVE
VALANCE C/W CORNER
BEAD, PAINTED
FINISH
ON ALL EXTERIOR SIDES.
U/S OF VALANCE TO ALIGN
WITH U/S OF CENTER
BULKHEAD @ 10'-6" AFF.
PT-1
ALL CEILING METAL
STUD FRAMING
SECURED TO CEILING
STRUCTURE ABOVE,
PAINTED FLAT BLACK
U/S OF EXISTING
CEILING
2'-0"
SUSPENDED BULKHEAD,
5/8" GWB OVER METAL STUD
FRAMING @ 16" O.C.
BY GENERAL CONTRACTOR
C/W FINISH ON ALL
EXTERIOR SIDES
PT-1
6"
TOP OF FINISHED
FLOOR
BULKHEAD
SUPPORT
BY CONTRACTOR
EXISTING GWB, PAINTED
VA
RIE
S
3/4" THK. CONTINUOUS
PLYWOOD BACKING
BEHIND GWB
12" MIN.
3"
RE
CE
SS
LINE OF FINISHED
CEILING
EQ.EQ.
8"
PROVIDE WOOD
BLOCKING WITHIN
DRYWALL CEILING
FOR TRACK
MOUNTING
G.C. TO VERIFY DIMENSIONS OF
SAMSUNG SCREEN PRIOR TO
CONSTRUCTING OPENING; ADJUST
OPENING TO ENSURE 1/2" GAP
AROUND SCREEN - ALL SIDES
G.C. TO COORDINATE FINAL
EQUIPMENT & RECESS SIZE W/
CLIENT
3'-1" LC
D N
IC
HE
LCD MONITOR TO BE RECESSED INTO
PARTITION AND FLUSHED WITH MILLWORK
FINISH. CONTRACTOR TO PROVIDE
MOUNTING HARDWARE AS REQUIRED.
CUT HOLES IN BACK FOR WIRE ACCESS
AND VENTIN
CONTRACTOR TO PROVIDE 1/2" PLYWOOD
BLOCKING BEHIND DRYWALL TO SECURE
LCD. DRYWALL TO BE PAINTED BLACK
ALL SIDES OF RECESS TO BE PAINTED
BLACK
BLACK PAINT SPEC: BENJAMIN MOORE
'UNIVERSAL BLACK' 2118-10
4'-0"
MALL AREA SIDE
PROVIDE SLOTS FOR AIR CIRCULATION
BEHIND LCD, TOP & BOTTOM TYP.
7 7/8"
PROVIDE WOOD BLOCKING
FINISHED FLOOR
NEW 6" H BREAK METAL BASEBOARD
WITH BRUSHED STAINLESS STEEL
LOOK
3 1/8"
1/2"
SAMSUNG SCREEN TO BE SECURELY
FASTENED TO PLYWOOD BACKING WITH
Z-CLIPS AND CARRIAGE BOLTS FOR THIEF
PREVENTION
3'-0"
1/2"
ALIGN
ALIGN
MDF MILLWORK FINISH WD-1
MDF MILLWORK FINISH WD-1
WALL SECTIONS
A3.0
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
2
STOREFRONT GLAZING SECTION
3" = 1'-0" SCALE:
3
GRILLE ENCLOSURE SECTION
3" = 1'-0"
SCALE:
4
CENTRE BULKHEAD SECTION
1" = 1'-0"
SCALE:
6
COVE LIGHT/BULKHEAD SECTION
1" = 1'-0"
SCALE:
5
RETAIL CEILING TROUGH DETAIL
3" = 1'-0"
SCALE:
1
STOREFRONT COLUMN SECTION
3" = 1'-0"
10
'-6
" T
O U
/S
O
F
PR
OP
OS
ED
C
EIL
IN
G
14
'-0
" T
O U
/S
O
F
MA
LL
B
UL
KH
EA
D
3'-2
"
16
'-0
"
TO
U
/S
O
F M
AL
L C
EIL
IN
G
wireless
GRILLE
ENCLOSURE
6'-3" STOREFRONT OPENING
5'-11
1
2
" STOREFRONT OPENING
EXIST. STAINLESS STEEL FINISH /FHC
NEW STOREFRONT BULKHEAD TO
RECEIVE NEW FINISH WD-1
EXISTING ILLUMINATED HALO-LIT
SIGNAGE TO REPLACE WITH NEW
EXISTING STAINLESS STEEL FINISH
TO REMAIN
EXISTING FIRE HOSE CABINET TO
REMAIN
EXISTING STAINLESS STEEL BASE
TO REMAIN
EXISTING DEMISING WALL TO BE RECLADDED,
PL-1
1/2" U-CHANNEL ALUMINUM REVEAL BETWEEN
NEW STOREFRONT FINISH AND EXISTING
BULKHEAD
NEW GRILLE ENCLOSURE C/W
FINISH WD-1
1'-6
"
6'-4
1
2
"
NIC
2'-0"
EXISTING COLUMN TO BE RECLADDED
W/ METAL STUDS & MDF PANELS, WD-1
REFER TO MILLWORK DRAWINGS
FOR FINISHES OF ALL FIXTURE (TYPICAL)
4'-5
1
2
"
WD-1
NEW STOREFRONT GLAZING WITH VINYL STICKER
APPLIED AT THE TOP. OPAGUE PINK TO MATCH PT-2
TO RUN CLEAR OVER A 2'-0" LENGTH
G.C. TO SUPPLY AND INSTALL NEW
6" HIGH BREAKFORM S.S. BASE, MT-1
TO GRILLE ENCLOSURE. (TYP)
GRILLE
ENCLOSURE
G.C. TO SUPPLY AND INSTALL NEW 6" HIGH
BREAKFORM S.S. BASE, MT-1 TO GRILLE
ENCLOSURE AND DEMISING WALL. (TYP)
WD-1
NEW GRILLE ENCLOSURE AND CONCEALED
POCKET DOOR, FINISH WD-1. DOOR TO BE C/W
WITH NO VISIBLE HARDWARE AND TOUCH
LATCH
DEMISING
WALL
G.C. TO PROVIDE 1/8" REVEAL WHERE
INDICATED, TYP., PAINTED BLACK
SEAM BETWEEN POCKET DOOR AND FINISH TO
BE MINIMAL, MAX. 1/4" WIDTH
WHITE FROSTED VINYL DECALS APPLIED TO
THE LEGTH OF GLASS, REFER TO FA FOR MROE
INFORMATION.
4'-0
"
G.C. TO PROVIDE 1/8" REVEAL WHERE
INDICATED, TYP., PAINTED BLACKWD-1
NEW GWB STOREFRONT BULKHEAD
SOFFIT TO RECEIVE NEW PAINT PT-2
SEAM BETWEN POCKET DOOR AND
FINISH TO BE MINIMAL, MAX. 1/4"
WIDTH
IMPROVEMENTS & SIGN NOT TO BE
SUPPORTED FROM LANDLORD BULKHEAD
/ CEILING. PROVIDE ADDITIONAL AND / OR
SEPARATE FRAMING TO U/S OF
STRUCTURE.
4"
4" LIP, PAINTED MDF TO MATCH PT-2
WD-1
RECESSED SAMSUNG SCREEN ON COLUMN
3'-0
"
11"
3'-0
"
de
ca
l zo
ne
3'-0"
GLAZING 2'-0"
3'-0"
GLAZING
6" HIGH STAINLESS
STEEL U-CHANNEL
6" HIGH S.S. BASE,
MT-1
3'-6
"
1/8" REVEAL, PAINTED BLACK
1/2" ALUMINUM REVEAL
1/2" ALUMINUM REVEAL
1/8" REVEAL, PAINTED BLACK, LOCATION TO BE
CONFIRMED
G.C. TO PROVIDE SLIM
PROFILE WALL ANCHOR FOR
FLUSH FINISH BASED ON
VERTICAL MOUNT
1/2" ALUMINUM REVEAL
NEW
BANQUETTE
BULKHEAD
SOFFIT, PL-2
RETAIL FACE OF
STOREROOM
PARTITION
BACKLIT LED
GRAPHIC PANEL,
REFER TO
MILLWORK
DRAWINGS
NEW BANQUETTE
AREA, REFER TO
MILLWORK
DRAWINGS
EXISTING LETTER SIGNAGE TO
BE REMOVED AND REPLACED
WITH NEW, REFER TO
ELECTRICAL FOR POWER
CONNECTION FOR SIGNAGE
EXISTING STAINLESS STEEL
FINISH TO REMAIN
NEW GRILLE ENCLOSURE AND
CONCEALED POCKET DOOR,
FINISH WD-1. DOOR TO BE C/W
WITH NO VISIBLE HARDWARE
AND TOUCH LATCH
SEAM BETWEN POCKET DOOR
AND FINISH TO BE MINIMAL,
MAX. 1/4" WIDTH
NEW GRILLE ENCLOSURE
WITH CARRIER LOGO DESIGN
G.C. TO SUPPLY AND INSTALL
NEW 6" HIGH BREAKFORM S.S.
BASE, MT-1 TO GRILLE
ENCLOSURE. (TYP)
LINE OF DEMISING CAP/ FIRE
HOSE SURROUND
1
4
" THICK ACRYLIC LETTER
PAINTED PT-1 ADHERED TO SHOP
FINISH MDF TO MATCH CARRIER
COLOURS BELOW. REFER TO FA
FOR MORE INFORMATION.
3'-6
"1
0'-6
" T
O U
/S
O
F
PR
OP
OS
ED
B
UL
KH
EA
D
14
'-0
" T
O U
/S
O
F
MA
LL
C
EIL
IN
G
NEW 4" RUBBER BASE
THROUGHOUT @ RETAIL SIDE,
RB-1
GOOGLE FIXTURE BELL FIXTURETV FIXTURE
CHATR
DISPLAY
NEW 4" RUBBER BASE THROUGHOUT
AT RETAIL SIDE, RB-1
4"
6" 6" 1'-8"
2"
ACCESSORY
DISPLAY 5"
12
'-0
" T
O T
/O
E
XIS
TIN
G G
WB
W
AL
L
8
'-0
" T
O T
/O
E
XIS
TIN
G G
WB
NEW VERTICAL SIDE OF
BULKHEAD TO RECEIVE
FINISH WD-1
4'-0
" G
WB
E
XT
EN
SIO
N
TO
1
2'-0
" A
FF
.
2
MW0.5
RELOCATE EXISTING SECURITY CAMERA
TO COORDINATE WITH FIXTURE
4'-0
"
ADJUSTABLE LED LIGHT, REFER TO ELECTRICAL
6"
REFER TO MILLWORK DRAWINGS
FOR FINISHES OF ALL FIXTURE (TYPICAL)
WD-1
PT-1 PT-1
PL-2
9"
ACCESSORY
DISPLAY
ACCESSORY
DISPLAY
ACCESSORY
DISPLAY
APPLE FIXTURE
WD-1
1/2" U-CHANNEL BETWEEN NEW
STOREFRONT FINISH AND
EXISTING BULKHEAD
NEW STOREFRONT BULKHEAD
SOFFIT TO RECEIVE NEW
PAINT PT-2
PT-1
1'-6"
2'-0" 2'-0"
4'-0
"
10
'-6
" T
O U
/S
O
F
GW
B B
UL
KH
EA
D
GWB LIGHT COVE PAINTED PT-1,
REFER TO DWG. A3.0 FOR DETAIL
8'-0
" T
O U
/S
O
F
BA
NQ
UE
TT
E B
UL
KH
EA
D
PT-1
BACKWALL GWB BULKHEAD, PT-1
SUSPENDED GWB BULKHEAD BEYOND
GWB BULKHEAD, PT-1
2'-0"
IMPROVEMENTS & SIGN NOT TO BE
SUPPORTED FROM LANDLORD BULKHEAD
/ CEILING. PROVIDE ADDITIONAL AND / OR
SEPARATE FRAMING TO U/S OF
STRUCTURE.
RE
FE
R T
O D
WG
. 3
/A
4.0
1/2" ALUMINUM REVEAL
NEW RUBBER BASE PER FINISH SCHEDULE
ON A2.3
EXIST'G MALL
DEMISING WAL
TBOOTH
ADJACENT
RETAIL
SPACE
FINISHED FLOOR, REFER TO FINISHES
SCHEDULE FOR SPECIFICATION.
EXISTING BASE BUILDING
CEILING
GC TO INSTALL NEW
1
2
" THICK GYPSUM WALL
BOARD OVER EXISTING WALL FROM 8'-0"
A.F.F FINISHED TO 12''-0" A.F.F. WITH 'J' MOLD
CAP - TAPED, SPACKLED, SANDED, READY TO
RECEIVE NEW PAINT FINISH
U/S OF COVE CEILING @ 11'-1 3/4" AFF.
1
2
"
8'-0
" E
XIS
TIN
G G
WB
4'-0" N
EW
G
WB
INTERIOR ELEVATION
A4.0
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
2
INTERIOR ELEVATION
1/2" = 1'-0"
SCALE:
1
INTERIOR ELEVATION
1/2" = 1'-0" SCALE:
3
SECTION DETAIL
3" = 1'-0"
BACKLIT LED GRAPHIC PANEL,S-6
EXISTING DOOR AND FRAME TO
RECEIVE NEW FINISH PT-1
NEW SEAT AND SEAT BACK, M-6
EXISTING ALARM KEYPAD
EXISTING FIRE EXTINGUISHER
6'-3" OVERALL WIDTH
BUILT-IN BANQUETTE / GRAPHIC PANEL
PT-1
5"
MDF WITH FINISH PL-2
BACK WALL TO RECEIVE NEW FINISH
PT-1
4'-0
"4
'-0
"
8'-0
"
ADJUSTABLE LED LIGHT, TYP.
REFER TO ELECTRICAL
6"1'-6"
2'-0"
GWB LIGHT COVE PAINTED PT-1, TYP.
REFER TO DWG. A3.0 FOR DETAIL
PT-1
10
'-6
"1
'-6
"
SUSPENDED GWB BULKHEAD BEYOND
NEW BANQUETTE BULKHEAD SOFFIT
AND TWO SIDES FINISH WD-1
NEW BULKHEAD TO RECEIVE NEW
FINISH PT-1, TYP.
12
'-0
" T
O T
/O
E
XIS
TIN
G G
WB
W
AL
L
2
MW0.5
2'-6
"
REFER TO MILLWORK DRAWINGS
FOR FINISHES OF ALL FIXTURE (TYPICAL)
IMPROVEMENTS & SIGN NOT TO BE
SUPPORTED FROM LANDLORD BULKHEAD
/ CEILING. PROVIDE ADDITIONAL AND / OR
SEPARATE FRAMING TO U/S OF
STRUCTURE.
NEW GWB BULKHEAD TO RECEIVE NEW
FINISH PT-1
WD-1
1/2" ALUMINUM REVEAL BETWEEN FINISHES
WD-1 WD-1
4" RUBBER BASE, RB-14" RUBBER BASE, RB-1
1
1
2
"
5"
2'-0"
ENTRANCE TO
STORAGE ROOM
2'-11"
11
'-1
3
/4
"
7'-1
1
2
"
5'-9"
RETAIL FACE OF
STOREROOM PARTITION
BACKLIT LED GRAPHIC PANEL,
REFER TO MILLWORK
DRAWINGS
NEW BANQUETTE AREA, REFER
TO MILLWORK DRAWINGS
NEW VERTICAL SIDE OF BULKHEAD TO
RECEIVE NEW FINISH WD-1
NEW STOREFRONT BULKHEAD SOFFIT TO
RECEIVE NEW PAINT PT-2
BASE BUILDING DEMISING CAP BEYOND
RECESSED LCD SCREEN D-1, COMMERCIAL
QUALITY, PROVIDE BY OWNER
3'-6
"1
0'-6
" T
O U
/S
O
F
PR
OP
OS
ED
B
UL
KH
EA
D
NEW GRILLE ENCLOSURE, FINISH WD-1.
REFER TO MILLWORK DRAWINGS
FOR FINISHES OF ALL FIXTURE (TYPICAL)
IMPROVEMENTS & SIGN NOT TO BE
SUPPORTED FROM LANDLORD BULKHEAD
/ CEILING. PROVIDE ADDITIONAL AND / OR
SEPARATE FRAMING TO U/S OF
STRUCTURE.
PT-1 PT-1
PL-1
ACCESSORY
DISPLAY
ACCESSORY
DISPLAY
ACCESSORY
DISPLAY
ROGERS FIXTURE TV FIXTURE
2"
8"
4"APPLE FIXTURELG FIXTURE
7"
WD-1
G.C. TO SUPPLY AND INSTALL
NEW 6" HIGH BREAKFORM S.S.
BASE, MT-1 TO GRILLE
ENCLOSURE AND DEMISING
WALL. (TYP)
NEW 4" RUBBER BASE THROUGHOUT
AT RETAIL SIDE, RB-1
4'-0
" G
WB
E
XT
EN
SIO
N
TO
1
2'-0
" A
FF
.
4'-0
"
6"
PL-2
1'-6"
2'-0"2'-0"
BACKWALL BULKHEAD, PT-1
2'-0"
8
'-0
" T
O T
/O
E
XIS
TIN
G G
WB
4'-0
"
8'-0
" T
O U
/S
O
F
BA
NQ
UE
TT
E B
UL
KH
EA
D
ADJUSTABLE LED LIGHT, TYP.
REFER TO ELECTRICAL
GWB LIGHT COVE PAINTED PT-1, TYP.
REFER TO DWG. A3.0 FOR DETAIL
NEW 4" RUBBER BASE THROUGHOUT
@ RETAIL SIDE, RB-1
8
1
2
"
2
A3.0
1/2" U-CHANNEL BETWEEN NEW
STOREFRONT FINISH AND EXISTING
BULKHEAD
EXISTING DEMISING WALL TO RECLADDED, PL-1
14
'-0
" T
O U
/S
O
F
MA
LL
C
EIL
IN
G
SUSPENDED GWB BULKHEAD BEYOND
GRILLE ENCLOSURE
5"
DEMISING
WALL
NEW BANQUETTE BULKHEAD
SOFFIT, PL-2
12
'-0
" T
O T
/O
E
XIS
TIN
G G
WB
W
AL
L
RE
FE
R T
O D
WG
. 3
/A
4.0
1/2" ALUMINUM REVEAL
NEW STOREFRONT BULKHEAD
SOFFIT TO RECEIVE NEW PAINT
PT-2
1/2" ALUMINUM REVEAL
S.S. BASE, MT-1 ALL AROUND COLUMN
4'-0"
3'-0"
WD-1
1/8" REVEAL, PAINTED BLACK,
LOCATION TO BE CONFIRMED
10'-6" T
O U
/S
O
F
PR
OP
OS
ED
B
ULK
HE
AD
14'-0" T
O U
/S
O
F
MA
LL C
EILIN
G
3'-6"
3'-6"
NEW VERTICAL SIDE OF
BULKHEAD TO RECEIVE
FINISH WD-1
1/2" U-CHANNEL BETWEEN NEW
STOREFRONT FINISH AND
EXISTING BULKHEAD
SEAM BETWEEN POCKET DOOR
AND FINISH TO BE MAX. 1/4"
WIDTH
NEW CONCEALED DOOR FOR
SCREEN SERVICING, FINISH WD-1.
DOOR TO BE C/W TOUCH / LATCH
MAGNETIC HARDWARE
WD-1
WD-1
WD-1
NEW SEAT AND SEAT
BACK, M-6
BANQUETTE TO BE
FLUSHED WITH
ADJACENT GWB
B
A
N
Q
U
E
T
T
E
M
I
L
L
W
O
R
K
PT-1
HE
IG
HT
O
F B
AN
QU
ET
TE
TO
M
EE
T W
IT
H B
ULK
HE
AD
BANQUETTE TO BE FLUSHED
WITH ADJACENT GWB BULKHEAD
BACKLIT LED
GRAPHIC PANEL,S-6
PT-1
INTERIOR ELEVATION
A4.1
DG
AS SHOWN
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
SCALE:
2
INTERIOR ELEVATION
1/2" = 1'-0"
SCALE:
1
INTERIOR ELEVATION
1/2" = 1'-0" SCALE:
3
INTERIOR ELEVATION
1/2" = 1'-0" SCALE:
4
[M-6] BANQUETTE - ISOMETRIC DIAGRAM
NTS
QR
A
FE
11'-5"
EXISTING PENDANT FIXTURE TO
BE REMOVED, TYPICAL.
REFER TO ELECTRICAL
EXISTING FLUORESCENT LIGHT
FIXTURES TO BE REMOVED,
TYPICAL. REFER TO ELECTRICAL
EXISTING GWB BULKHEAD TO BE
REMOVED
EXISTING LOWER BULKHEAD TO BE
REMOVED
EXISTING EMERGENCY LIGHT
TO REMAIN
EXISTING TRANSFORMER
TO REMAIN
EXISTING PENDANT FIXTURE TO
BE REMOVED, TYPICAL
EXISTING TRACK AND RECESSED
LIGHTING TO BE REMOVED,
TYPICAL.
REFER TO ELECTRICAL
EXISTING SPRINKLERS ON BULKHEAD TO BE
RELOCATED AS REQUIRED, TYPICAL.
REFER TO MECHANICAL
EXISTING ILLUMINATED HALO-LIT
SIGNAGE TO BE REMOVED AND
REPLACED WITH NEW
EXISTING GWB BULKHEAD TO BE
REMOVED
EXISTING GRILLE DOOR AND
TRACK TO BE REMOVED, TYP.
EXISTING FLUORESCENT
FIXTURE TO BE REMOVED
EXISTING LAMINATED BULKHEAD
TO BE REMOVED
EXISTING T-BAR CEILING
TO REMAIN
11'-0" AFF
OPEN
OPEN
EXISTING DOWNLIGHT TO BE
REMOVED, TYP.
REFER TO MECHANICAL DRAWINGS FOR
RELOCATION OF ALL HVAC EQUIPMENT AND
SPRINKLERS
REFLECTED CEILING PLAN
DEMOLITION
A6.0
DG
AS SHOWN
SCALE:
1
DEMOLITION REFLECTED CEILING PLAN
3/8" = 1'-0"
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
NORTH
QR
A
FE
4 1/2"
4'-10"
2'-0
"
10'-6" AFF
10'-6" AFF
NEW LIGHT FIXTURE MOUNT IN
EXISTING T-BAR CEILING AT
WORKROOM
ALL NEW TRACK LIGHT FIXTURES TO
BE SUSPENED @ 10'-6" A.F.F. ENSURE
NO INTERFERENCE WITH CEILING
DIFFUSERS
EXISTING CEILING OPEN TO STRUCTURE.
CLEAN AND PAINT FLAT BLACK FROM 12'-0" A.F.F.
NEW SLIDING GRILLE TRACK TO
REPLACE EXISTING. RECESS TRACK TO
FULLY FLUSH WITH UNDERSIDE OF
BULKHEAD. ENSURE MINIMUM 4"
CLEARANCE ON EITHER SIDE OF TRACK
ALONG ENTIRE TRACK LENGTH.
NEW LED DOWNLIGHT TO BE RECESSED
WITHIN NEW GWB BULKHEAD.
REFER TO ELECTRICAL
REFER TO MECHANICAL DRAWINGS FOR
HVAC LAYOUT AND NEW / RELOCATED
SPRINKLER LOCATIONS.
LED FIXTURE WITHIN COVE.
REFER TO ELECTRICAL
T
Y
P
.
T
Y
P
.
PT-2
PT-1
7
'
-
1
1
"
NEW ILLUMINATED HALO-LIT SIGNAGE
MOUNTED TO STOREFRONT BULKHEAD. REFER
TO ELEVATIONS AND SIGN CONTRACTORS
SHOP DRAWINGS FOR DETAILS
GWB BULKHEAD TO BE SUSPENDED
FROM STRUCTURE ABOVE WITH H/D
AIRCRAFT CABLE @ 10'-6" A.F.F. REFER
TO DWG. A3.0 FOR CONSTRUCTION AND
FINISH DETAILS. G.C. TO ENSURE ALL
WIRINGS TO FULLY CONCEALED FROM
ALL VIEW.
NEW BULKHEAD @ 10'-6" A.F.F. TO BE
PAINTED TO MATCH PT-2
TRACK LIGHT FIXTURES IN SUSPENDED
BULKHEADS TO BE CONNECTED TO ONE
SWITCH SUCH THAT THEY FUNCTION
INDEPENDENTLY OF GENERAL RETAIL
LIGHTING - REFER TO ELECTRICAL
ENGINEER'S DRAWINGS FOR DETAILS.
SUITABLE ACCESS MUST BE PROVIDED BY
TENANT TO ALL EQUIPMENT CONCEALED BY
HIS WORK WHICH REQUIRES ROUTINE
MAINTENANCE OF CONTROL ADJUSTMENT.
REFER TO ENGINEER DRAWINGS FOR
LOCATIONS OF ACCESS PANELS IN NEW
CEILING
STOCK ROOM LIGHTING TO BE CONTROLLED
ON A OCCUPANCY SENSOR.
NEW LAMINATED BULKHEAD TO BE
PAINTED TO MATCH PT-2
5
A3.0
REFER TO ELECTRICAL DRAWINGS FOR
ALL LIGHTING REQUIREMENTS.
REFER TO STRUCTURAL DRAWINGS
FOR STRUCTURAL SUPPORT OF NEW
DOOR TRACK
G.C. TO INSTALL 8" W x 8" H (INTERIOR)
GWB LIGHT COVE TO 11'-1 3/4" A.F.F. AT
RETAIL SIDE OF PERIMETER WALL, TYP.
REFER TO DWG. A3.0
G.C. TO INSTALL 8" W x 8" H
(INTERIOR) GWB LIGHT COVE TO
11'-1 3/4" A.F.F. AT RETAIL SIDE OF
PERIMETER WALL.
REFER TO DWG. A3.0
G.C. TO INSTALL 8" W x 8" H (INTERIOR) GWB
LIGHT COVE TO 11'-1 3/4" A.F.F. AT RETAIL
SIDE OF PERIMETER WALL.
REFER TO DWG. A3.0
8'-0" AFF
15'-0"
2'-0"
1'-1
0"
2'-0
"
2'-0
"
1'-10"
TYP.
4'-0
"2
'-0
"4
'-0
"4
'-0
"4
'-0
"4
'-0
"4
'-0
1
/2
"4
'-0
"4
'-0
"1
'-1
"
39
'-4
1
/2
"
4'-0"1'-8" 1'-8" 1'-10"
TYP.
4'-0
"2
'-0
"4
'-0
"4
'-0
"4
'-0
"
4
'
-
0
"
PT-1
2
'-
3
"
4
'-
0
"
1
'
-
3
1
/
2
"
2
'
-
8
"
3
'
-
1
1
/
2
"
1
'
-
5
"
3
'
-
5
"
2
'
-
9
1
/
2
"
2'-0" 2'-0"
11 '-1 3/4" AFF
PT-1
10'-6" AFFPT-1
8'-0" AFF
WD-1
OPEN
TYP. TYP.
10'-6" AFF
PT-1
NEW TRACK LIGHT FIXTURES SECURED
WITHIN SUSPENDED BULKHEAD ABOVE.
REFER TO MILLWORK DETAILS FOR
ADDITIONAL INFORMATION
GWB BULKHEAD TO BE SUSPENDED
FROM STRUCTURE ABOVE WITH H/D
AIRCRAFT CABLE @ 10'-6" A.F.F.
BULKHEAD TO BE SUSPENDED
DIRECTLY ABOVE MILLWORK
FIXTURES. REFER TO DWG. A3.0 FOR
CONSTRUCTION AND FINISH DETAILS.
G.C. TO ENSURE ALL WIRINGS TO
FULLY CONCEALED FROM ALL VIEW.
10'-6" AFF
PT-1
11 '-1 3/4" AFF
PT-1
LED FIXTURE WITHIN COVE, TYP.
REFER TO DWG. A3.0 & ELECTRICAL
LED FIXTURE WITHIN COVE, TYP.
REFER TO DWG. A3.0 & ELECTRICAL
LED FIXTURE WITHIN COVE, TYP.
REFER TO DWG. A3.0 & ELECTRICAL
DATA POWER INTERGRATION BOX IN
CEILING. REFER TO ELECTRICAL
7'-4 1/2"
ALL NEW OR RELOCATED SPRINKLERS,
REFER TO MECHANICAL. TYP.
NEW DUAL-VIEW FOOT COUINTER SENSOR
IN BULKHEAD, REFER TO ELECTRICAL
5'-3
"5
'-3
"
1'-6
"
5'-3
"5
'-3
"
10
'-6
"1
0'-6
"
6'-0
"6
'-0
"6
'-0
"
4
'
-
0
"
4
'
-
0
"
2'-3
"2
'-3
"2
'-3
"2
'-3
"2
'-3
"
6
'
-
0
"
2'-6" 6'-0" 2'-6"
2'-6
"
2
'
-
6
1
/
2
"
3
'
-
3
"
4
'-
8
"
4 1/2"
8"
1/2" ALUMINUM REVEAL
1/2" ALUMINUM REVEAL
4
A3.0
1
A3.0
2
A3.0
REFER TO MILLWORK PACKAGE FOR
CEILING DETAIL IN BANQUETTE SEATING
NEW GWB CEILING, PAINTED
1. REFER TO SPRINKLER DRAWINGS FOR ALL SPRINKLER HEAD
LOCATIONS.
2. RUN ALL SPRINKLER LINES IN JOIST SPACE - AS REQUIRED.
3. SPRINKLER CONTRACTOR TO BE RESPONSIBLE FOR RELOCATING
ALL EXISTING SPRINKLER HEADS INTERFERING WITH NEW LIGHT,
MECHANICAL DUCT AND BULKHEAD LOCATIONS - COORDINATE
WITH ALL TRADES PRIOR TO INSTALLATION.
4. CONTRACTOR TO CHECK THE DRAWING AGAINST EXISTING SITE
CONDITIONS BEFORE ISSUING TENDER PRICE.
5. SPRINKLER CONTRACTOR TO PROVIDE SPRINKLERS IN NEW T-BAR
OR GWB AS REQUIRED TO MEET ALL CODE REQUIREMENTS.
SPRINKLER CONTRACTOR TO ENSURE ALL BACK AREAS (STOCK
ROOMS, OFFICES, WASHROOMS) ARE SPRINKLERED AND PROVIDE
SPRINKLERS TO U/S OF ALL MEZZANINES.
6. CONTRACTOR TO REVIEW ELECTRICAL ENGINEER'S DRAWINGS IN
CONJUNCTION WITH THIS LIGHTING PLAN AND DETAILS.
7. CONTRACTOR TO REPORT ANY/ALL DISCREPANCIES OR
CONFLICTS TO THE CONSULTANTS IMMEDIATELY FOR
RESOLUTION.
8. CONTRACTOR TO CONFIRM THAT ANY EXISTING LIGHTING
FIXTURES BEING REUSED ARE IN GOOD WORKING ORDER.
9. CONTRACTOR TO CLEAN RE-LENS AND RE-LAMP ALL EXISTING
FIXTURES BEING REUSED.
10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR QUANTITY
TAKEOFFS AND FOR ORDERING ALL NECESSARY ACCESSORY
PARTS REQUIRED FOR PROPER INSTALLATION OF THE SPECIFIED
SYSTEM (NEW OR REPLACEMENT) FOR COMPLETION WITHIN THE
CONTRACTED TIME FRAME.
11. CONTRACTOR SHALL VERIFY ON SITE, LIGHTING FIXTURE HEIGHTS
ON ELEVATIONS AND LIGHTING PLAN WITH CLIENT
REPRESENTATIVE/PROJECT MANAGER PRIOR TO INSTALLATION ON
SITE.
12. ALL LIGHT FIXTURES AND EQUIPMENT USED SHALL MEET ANY AND
ALL APPLICABLE CODES OF GOVERNING BODIES HAVING
JURISDICTION, INCLUDING BUT NOT LIMITED TO LOCAL, CITY AND
PROVINCIAL CODES/BY-LAWS AS WELL AS HEALTH DEPARTMENT
REGULATIONS.
13. CONTRACTOR RESPONSIBLE FOR ORDERING ALL ELECT.
EQUIPMENT SHALL, UPON AWARD OF CONTRACT, DETERMINE
DELIVERY TIMES ETC WITH MANUFACTURERS. CONTRACTOR
SHALL BE SOLELY RESPONSIBLE FOR ENSURING DELIVERY OF
LIGHTS ETC. AT REQ'D TIME. NO SUBSTITUTIONS WILL BE
APPROVED ARISING FROM THE CONTRACTOR NOT ORDERING
EQUIPMENT AND/OR SUPPLIES IN TIME.
14. ALL FIXTURES INSTALLED MUST BE PER JOB SPECIFICATIONS. ANY
SUBSTITUTIONS WHICH MAY BE REQUIRED DUE TO EXTENDED
DELIVER DATES ETC., MUST BE SUBMITTED TO CLIENT FOR
WRITTEN APPROVAL PRIOR TO ORDER OR INSTALLING THE
SUBSTITUTE FIXTURES.
15. THE SUPPORTS REQUIRED FOR MOUNTING AND INSTALLATION OF
RECESSED LIGHT FIXTURES SHALL BE SUPPLIED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR. THE SUPPORT SHALL BE
ATTACHED TO THE STRUCTURE. THE CEILING SYSTEM SHALL NOT
BE A MEANS OF SUPPORT.
REFLECTED CEILING PLAN NOTES
16. SURFACE MOUNTED FIXTURES EXCEEDING 20lbs SHALL BE
INDEPENDENTLY SUPPORTED FROM THE STRUCTURE.
17. PROVIDE ADDITIONAL SUPPORTS, HANGERS, ETC., AS
REQUIRED TO SUPPORT FIXTURES MOUNTED UNDER
DUCTWORK. THE FIXTURE SUPPORT SHALL NOT BE
ATTACHED TO EITHER THE DUCTWORK OR THE DUCTWORK
SUPPORTS.
18. CONTRACTOR TO PAINT OUT ALL SUPPLY/RETURN AIR
GRILLES/DIFFUSERS TO MATCH ADJACENT CEILING/WALL
FINISH.
19. REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR
EMERGENCY LIGHTING, EXIT SIGNS AND FIRE PULL STATION
LOCATIONS AND DETAILED ELECTRICAL SPECIFICATIONS.
20. TILES TO BE PAINTED BEFORE BEING INSTALLED IN GRID. G.C.
TO ENSURE 100% COVERAGE OF ALL CEILING TILES WITH
PAINT FINISH.
21. ALL EQUIPMENT TO BE VERIFIED BY CLIENT PRIOR TO
INSTALLATION.
22. FIT SUPPLY AND RETURN AIR TO SUIT NEW
LAYOUT/OCCUPANCY EQUIPMENT LOAD BALANCE SYSTEM.
SEE MECHANICAL CONTRACTORS DRAWINGS FOR DETAILS.
23. CEILING HEIGHTS ARE NOTED FOR EACH AREA, WHERE
THOSE CANNOT BE ACHIEVED, GENERAL CONTRACTOR TO
NOTIFY ARCHITECT IMMEDIATELY.
24. REFLECTED CEILING PLAN MUST BE USED IN CONJUNCTION
WITH ALL SECTIONS, ELEVATIONS, AND DETAILS FOR A FULL
UNDERSTANDING OF CEILING HEIGHTS REQUIRED.
25. GENERAL CONTRACTOR TO INSTALL ELECTRICAL
CONNECTIONS FOR SIGNAGE (WHERE APPLICABLE).
26. GENERAL CONTRACTOR TO SUPPLY FIRE STOPPING AS
REQUIRED BY CODE.
27. REFER TO MECHANICAL ENGINEER'S DRAWINGS FOR ALL
LOCATIONS OF DUCTWORK, SUPPLY/RETURN AIR GRILLES
AND DIFFUSERS, FIRE DAMPERS AND ANY OTHER HVAC
EQUIPMENT.
28. ALL HEADS IN HARD CEILING (I.E.: GYPSUM BOARD) TO BE
FULLY RECESSED WITH COVERS PAINTED TO MATCH.
29. MECHANICAL CONTRACTOR TO PROVIDE DUCT/HVAC LAYOUT
TO SUIT REFLECTED CEILING PLAN LAYOUT & REFLECTED
CEILING PLAN BALANCE SYSTEM.
30. DO NOT SCALE DRAWINGS.
31. G.W.B. CONTRACTOR TO WORK IN CONJUNCTION WITH
FLOORING CONTRACTOR TO ENSURE CRITICAL ALIGNMENT
OF BULKHEAD WHERE APPLICABLE.
32. G.W.B. CONTRACTOR TO CUT NEW OPENINGS IN GWB CEILING
WITH FRAMING AS REQUIRED TO SUPPORT NEW AND
RELOCATED RECESSED LIGHT FIXTURES. REFER TO
REFLECTED CEILING PLAN FOR LOCATIONS.
33. G.W.B. CONTRACTOR TO PATCH AND REPAIR EXISTING
CEILING WHERE DEMOLITION HAS OCCURRED.
34. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES IN
THE JURISDICTION WHERE THE WORK IS LOCATED.
MECHANICAL NOTES
1. ALL WORK SHALL CONFORM TO C.S.A., NATIONAL BUILDING CODE AND
LOCAL MUNICIPAL AND PROVINCIAL LAWS AND REGULATIONS.
2. MECHANICAL CONTRACTOR TO BE RESPONSIBLE FOR ENSURING ALL
ENCLOSED ROOMS AND BACK AREAS (FITTING ROOMS, STOCK ROOMS,
OFFICES) HAVE ADEQUATE AIR SUPPLY AND RETURN VENTILATION.
3. BALANCING OF DIFFUSERS AND GRILLES MUST BE PERFORMED ONLY BY
A PERSON WHO IS THOROUGHLY EXPERIENCED IN THE OPERATION OF A
SYSTEM OF THIS NATURE AND HAS DEMONSTRATED QUALIFICATIONS BY
HAVING SUCCESSFULLY DONE SO PRIOR TO THIS INSTALLATION. THE
COSTING OF ALL BALANCING SHALL BE INCLUDED IN THE TENDER PRICE.
REFLECTED CEILING PLAN LEGEND
SYMBOL CEILING TYPE DESCRIPTION
LIGHT FIXTURE LEGEND
SYMB.
NEW RECESSED LED DOWNLIGHT FIXTURE
· REFER TO ELECTRICAL
QTY. SUPPLIER:DESCRIPTION
NEW TRACK LIGHT FIXTURES
· REFER TO ELECTRICAL
GENERAL NOTES
1. REFER TO ELELCTRICAL FOR ALL LIGHTING REQUIREMENTS.
2. CONTRACTOR TO SUPPLY 10 EXTRA LIGHT OF EACH TYPE OF LED LAMPS FOR FUTURE USE.
3. LIGHTING INSTALLER TO DIRECT HEADS TOWARD DISPLAY, AS PER MANAGER'S INSTRUCTION.
GWB BULKHEAD
· 5/8" GYPSUM WALL BOARD CONSTRUCTION
NEW LED LIGHT FIXTURE
· REFER TO ELECTRICAL
NEW T-BAR CEILING AND TILES
· ARMSTRONG DUNE FINE TEXTURED #1773 2'x4'x5/8" TILE - WHITE
CEILING / WALL MOUNTED SELF POWER LED EXIT SIGN
· REFER TO ELECTRICAL
NEW LED RGB COVE LIGHT
· REFER TO ELECTRICAL
1. ALL WORK AFFECTING LL BASE BUILDING SUCH AS SPRINKLER SYSTEM,
HVAC SYSTEM, ROOF WORK, TILE WORK OUTSIDE OF LEASED AREA OR
ELECTRICAL WORK OUTSIDE OF LEASED AREA WILL BE REQUIRED TO BE
PERFORMED BY A LL DESIGNATED OR LL APPROVED CONTRACTOR AND
BE ENGAGED BY THE TENANT.
2. ALL DESIGN COMPONENTS TO MEET CURRENT SEISMIC RESTRAINT
CODES.
3. ALL OPEN AREAS AND STRUCTURAL SUPPORTS ABOVE OPEN CEILING TO
BE REPAINTED FLAT BLACK.
GENERAL NOTES
EMERGENCY BATTERY UNIT
· REFER TO ELECTRICAL
EMERGENCY SINGLE REMOTE RECESSED LIGHT
· REFER TO ELECTRICAL
PER ELECT.
PER ELECT.
PER ELECT.
PER ELECT.
PER ELECT.
PER ELECT.
PER ELECT.
UPRIGHT / CONCEALED SPRINKLER HEAD
· REFER TO MECHANICAL
PER MECH.
NEW PENDANT LIGHT @ 9'-6" AFF.
· REFER TO ELECTRICAL
PER ELECT.
REFLECTED CEILING PLAN
A6.1
DG
AS SHOWN
SCALE:
1
REFLECTED CEILING PLAN
3/8" = 1'-0"
UN
IT
7
58
, 3
00
B
oro
ug
h D
rive
SC
AR
BO
RO
UG
H
TO
WN
C
EN
TR
E
Sca
rb
oro
ug
h, O
nta
rio
DESCRIPTION
DRAWING TITLE
PROJECT
SHEET NO.
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
PROJECT NO.:
BY
JOHN E. GUSTAVSON ARCHITECT INC.
USE OR REPRODUCTION PROHIBITED
WITHOUT PRIOR WRITTEN PERMISSION.
THE GENERAL CONTRACTOR SHALL
REVIEW THE DOCUMENTS FOR
CONFORMANCE OF CODES AND
BYLAWS AND SHALL ADVISE THE
ARCHITECT OF ANY DISCREPANCIES HE
MAY NOTE. THE GENERAL CONTRACTOR
SHALL CHECK AND VERIFY ALL
DIMENSIONS AND REPORT ALL ERRORS
AND OMISSIONS TO THE DESIGNER, DO
REVISIONNO DATE
NOT SCALE THE DRAWINGS.
ALL RIGHTS RESERVED. PROPERTY OF
BYISSUED FORNO DATE
16224
DC
Unit 758, 300 Borough Drive, Scarborough, Ontario
SCARBOROUGH
TOWN CENTRE
ISSUED FOR TENDER
DGISSUED FOR COORDINATION101/16/17
January 27, 2017
JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,
VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203
www.gwa.ca
BWISSUED FOR LANDLORD REVIEW201/20/17
BWISSUED FOR BUILDING PERMIT301/27/17
BWISSUED FOR TENDER 404/03/17
NORTH
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
COVER PAGE
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-00
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
MILLWORK DETAILS
MW-0.0 COVER SHEET
MW-1.0 M-1 CARRIER LOGO WALL
MW-2.0 M-2 SMALL DISPLAY TABLE
MW-3.0 M-3 LARGE DISPLAY TABLE
MW-4.0 M-4 CASH TABLE
MW-5.0 M-5 ACCESSORIES DISPLAY
MW-6.0 M-6 BANQUETTE W/ BACKLIT GRAPHICS PANEL
MW-7.0 M-7 CUSTOM OTTOMAN
MW-8.0 M-8 CARRIER DISPLAY
B
C
A3
A4
A2
A1
B
B
B
C
C
C
A5
CARRIER DESCRIPTION#
ROGERS ROGERS REDA1
BELL PANTONE PMS301CA2
FIDO 100% BLACK, PANTONE 012CA3
VIRGIN 100% BLACK, VSPOT REDA4
CHATR PURPLE PMS2597C, ORANGE PMS144SA5
SCALE:
1
MW-1.0
[M-1] ELEVATION OF CARRIER LOGO WALL
1" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-1]
CARRIER LOGO WALL
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-1.0
SCALE:
2
MW-1.0
[M-1] CARRIER LOGO WALL - DETAILED ELEVATION
1" = 1'-0" SCALE:
3
MW-1.0
[M-1] CARRIER LOGO WALL - DIMENSION ELEVATION
1" = 1'-0"
SCALE:
4
MW-1.0
[M-1] CARRIER LOGO WALL - SECTION PLAN
1 1/2" = 1'-0" SCALE:
5
MW-1.0
[M-1] CARRIER LOGO WALL - DETAIL OF ACRYLIC BOXES
1 1/2" = 1'-0"
SCALE:
1
MW-2.0
[M-2] SMALL DISPLAY TABLE - PLAN
1 1/2" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-2]
SMALL DISPLAY TABLE
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-2.0
SCALE:
2
MW-2.0
[M-2] SMALL DISPLAY TABLE - FRONT ELEVATION
1 1/2" = 1'-0" SCALE:
3
MW-2.0
[M-2] SMALL DISPLAY TABLE - SIDE ELEVATION
1 1/2" = 1'-0"
SCALE:
4
MW-2.0
[M-2] SMALL DISPLAY TABLE - SECTION ELEVATION
1 1/2" = 1'-0" SCALE:
5
MW-2.0
[M-2] SMALL DISPLAY TABLE - PLAN SECTION
1 1/2" = 1'-0"
SCALE:
3
MW-3.0
[M-3] LARGE DISPLAY TABLE - FRONT ELEVATION
1 1/2" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-3]
LARGE DISPLAY TABLE
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-3.0
SCALE:
2
MW-3.0
[M-3] LARGE DISPLAY TABLE - SIDE ELEVATION
1 1/2" = 1'-0"
SCALE:
1
MW-3.0
[M-3] LARGE DISPLAY TABLE - PLAN
1 1/2" = 1'-0"
SCALE:
5
MW-3.0
[M-3] LARGE DISPLAY TABLE - SECTION PLAN
1 1/2" = 1'-0" SCALE:
4
MW-3.0
[M-3] LARGE DISPLAY TABLE - SECTION ELEVATION
1 1/2" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-4]
CASH TABLE
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-4.0SCALE:
1
MW-4.0
[M-4] CASH TABLE - PLAN
1 1/2" = 1'-0"
SCALE:
2
MW-4.0
[M-4] CASH TABLE - FRONT ELEVATION
1 1/2" = 1'-0"
SCALE:
3
MW-4.0
[M-4] CASH TABLE - SIDE ELEVATION
1 1/2" = 1'-0"
SCALE:
4
MW-4.0
[M-4] CASH TABLE - SIDE ELEVATION
1 1/2" = 1'-0"
SCALE:
5
MW-4.0
[M-4] CASH TABLE - SECTION ELEVATION
1 1/2" = 1'-0"
SCALE:
6
MW-4.0
[M-4] CASH TABLE - TABLE LEG DETAIL
1 1/2" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-5]
ACCESSORIES DISPLAY
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-5.0SCALE:
2
MW-5.0
[M-5] ACCESSORIES DISPLAY - FRONT ELEVATION
1 1/2" = 1'-0" SCALE:
3
MW-5.0
[M-5] ACCESSORIES DISPLAY - SIDE ELEVATION
1 1/2" = 1'-0"
SCALE:
1
MW-5.0
[M-5] ACCESSORIES DISPLAY - PLAN
1 1/2" = 1'-0"
SCALE:
4
MW-5.0
[M-5] ACCESSORIES DISPLAY - SECTION ELEVATION
1 1/2" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-6]
BANQUETTE C/W
BACKLIT GRAPHICS
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-6.0SCALE:
1
MW-6.0
[M-6] BANQUETTE C/W BACKLIT GRAPHIC - FRONT ELEVATION
1" = 1'-0" SCALE:
2
MW-6.0
[M-6] BANQUETTE C/W BACKLIT GRAPHIC - SECTION ELEVATION
1" = 1'-0"
B
A
C
E
A
B
C
D
E
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-7]
CUSTOM OTTOMAN
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-7.0
SCALE:
1
MW-7.0
[M-7] CUSTOM OTTOMAN - PLAN
1 1/2" = 1'-0" SCALE:
2
MW-7.0
[M-7] CUSTOM OTTOMAN - ELEVATION
1 1/2" = 1'-0"
SCALE:
3
MW-7.0
[M-7] CUSTOM OTTOMAN - SECTION ELEVATION
3" = 1'-0"
KB03APR2017ISSUED FOR TENDER-R102
AW28FEB2017ISSUED FOR TENDER01
387 Richmond Street East
Toronto Canada M5A 1P6
www.sld.com
t 416.367.1999
f 416.367.5451
DRAWING NUMBER:
DOCKET:
SHEET SIZE:
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
SL16790
ARCH D
DRAWING NAME:
PROJECT:
CLIENT:
CONSULTANT
GLENTEL
TBOOTH WIRELESS
SCARBOROUGH TOWN CENTRE
UNIT #758
300 BOROUGH DR
SCARBOROUGH,ON
M1P 4P5
ISSUES AND REVISIONS ( ): BY:DATE:
1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS
ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX
DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN
WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI
LACROIX.
2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT
ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING
WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE
CONTRACTOR'S EXPENSE.
3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S
DRAINGS IN THE CONTRACT.
4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.
5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE
DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.
6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN
CONFORMITY WITH THE BUILDING CODES IN FORCE.
7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE
CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE
TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL
EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.
GENERAL NOTES:
28-02-2017
as noted bw
aw
MILLWORK DETAILS
[M-8]
CARRIERS DISPLAY
ISSUED FOR
TENDER
DRAWINGS NOT FOR
CONSTRUCTION
MW-8.0SCALE:
2
MW-8.0
[M-8] CARRIERS DISPLAY - ELEVATION
1 1/2" = 1'-0" SCALE:
4
MW-8.0
[M-8] CARRIERS DISPLAY - SECTION ELEVATION
1 1/2" = 1'-0"SCALE:
3
MW-8.0
[M-8] CARRIERS DISPLAY - SECTION ELEVATION
1 1/2" = 1'-0"
SCALE:
1
MW-8.0
[M-8] CARRIERS DISPLAY - PLAN
1 1/2" = 1'-0"