Upload
trantu
View
223
Download
2
Embed Size (px)
Citation preview
Start
Below is a flowchart describing 40 CFR Part 60, Subpart IIII. It will likely not be accessible using a screen reader. For the text of the statute/rule, please go to
40 CFR Part 60, Subpart IIII (1 of 103)
§60.4200(a)(2),§60.4200(a)(3)
§60.4200(b)
No
Can you request an exemption for national security
purposes?
§60.4200(d)
Are you an owner/operator of a
stationary compression ignition (CI) internal combustion engine (ICE) that
commenced construction ormodified/reconstruction
after 07/11/2005?
40 CFR Part 60 Subpart IIII does not
apply
Is the CI ICE being tested at an engine
test cell/stand?
Yes
No
Is the CI ICE acting as a temporary replacement
and located at a stationary source for < 1 year and properly certified to standards
applicable to such engines under appropriate nonroad
provisions?
No
§60.4200(e)
Yes
Yes
Yes
No
1
End
Are you commencing construction?
No
§60.4200(a)(3)
Yes 2
3
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(2 of 103)
2
Is the emergency CI
ICE a fire pump engine?
Was the emergency fire pump CI ICE manufactured after
07/01/2006?
End
§60.4217
NoComply with the following:
Standard§60.4217
Yes
§60.4200(a)(2)(i)
§60.4200(a)(2)(i)
§60.4200(a)(2)(ii)
§60.4200(a)(2)(ii)
3
For purposes of 40 CFR 60 Subpart IIII: Fire pump engine is defined as an
emergency engine certified to National Fire Protection
Association (NFPA) requirements that is used to
provide power to pump water for fire suppression or
protection.
Is the CI ICE a non-emergency
engine?
No
Was the CI ICE manufactured after
04/01/2006?
Yes
Yes
No
No
No
Yes
Is the CI ICE using diesel
fuel?
Yes
1
4
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
4
Is the CI ICE a non-emergency
engine?
No
Is the displacement
of the CI ICE < 10 liters per cylinder?
Is the displacement
of the CI ICE > 10 and< 15 liters per cylinder?
The displacement of the non-emergency CI ICE must be > 30 liters per cylinder.
Yes
No
No
Yes
YesNo
Yes Yes
Yes
No
Is the displacement
of the CI ICE > 15 and< 20 liters per
cylinder?
Is the displacement
of the CI ICE > 20 and< 25 liters per
cylinder?
Is the displacement
of the CI ICE > 25 and< 30 liters per
cylinder?
No
40 CFR Part 60, Subpart IIII(3 of 103)
§60.4204 §60.4204§60.4201
§60.4204§60.4201
§60.4204§60.4201
§60.4204§60.4201
§60.4204§60.4201
92
5
24
27
29
31
22
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
5
Is the CI ICE < 8 KW?
Is the CI ICE > 8 KW and
< 37 KW?
No
Is the CI ICE a pre-2007 model year?
Yes
Is the CI ICE < 8 KW?
Is the CI ICE a 2007 model
year?
No
Yes
No
Yes
NOxEmission limit =
9.2 g/KW-hr
HC
Comply with the following:Standard
§60.4204(a)-Table 1|4
Emission limit = 1.3 g/KW-hr
CO
Comply with the following:Standard
§60.4204(a)-Table 1|8
Emission limit = 11.4 g/KW-hr
PM
Comply with the following:Standard
§60.4204(a)-Table 1|11
Emission limit = 0.54 g/KW-hr
Comply with the following:Standard
§60.4204(a)-Table 1|3
Is the CIICE > 37 KW and
< 130 KW?
Yes
Yes
No
No
No
Yes
§60.4204(a)
§60.4204(a)
§60.4204(a)
§60.4201(a)
§60.4201(a)
§60.4204(a)
40 CFR Part 60, Subpart IIII(4 of 103)
14
6
11
10
7
8
8
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
Comply with the following:Standard
§60.4204(a)-Table 1
NMHC+NOx
Emission limit = 9.5 g/KW-hr
CO
Emission limit = 6.6 g/KW-hr
Comply with the following:Standard
§60.4204(a)-Table 1
Is the CI ICE
< 19 KW?CO
Comply with the following:Standard
§60.4204(a)-Table 1
Emission limit = 5.5 g/KW-hr
No
Comply with the following:Standard
§60.4204(a)-Table 1
NMHC+NOx
Emission limit = 10.5 g/KW-hr
CO
Emission limit = 8.0 g/KW-hr
Comply with the following:Standard
§60.4204(a)-Table 1
PM
Emission limit = 1.0 g/KW-hr
Comply with the following:Standard
§60.4204(a)-Table 1
6 7
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4204(a)-Table 1
Yes
§60.4204(a)
40 CFR Part 60, Subpart IIII(5 of 103)
8
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
8Comply with the following:
Standard§60.4206
§60.4207(b)§60.4218
§60.4209(b)
§60.4204(e)
Is the CI ICE being modified/
reconstructed?
Comply with the following:Standard
§60.4204(e)§60.4211(e)
All of the following questions/requirements
will apply to each individual pollutant that
has been picked up.
§60.4214
Is the CIICE equipped with a diesel particulate
filter?
Comply with the following:Monitoring/Testing
§60.4209(b)Recordkeeping§60.4214(c)
Yes
No
Yes
No
§60.4214
Yes
NoNo
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
Is theCI ICE > 10 liters per
cylinder?
Comply with the following:Standard
§60.4211(e)(1)
End
Comply with the following:Standard
§60.4204(d)Monitoring/Testing
§60.4211(e)(2)[G]§60.4212
Comply with the following:Recordkeeping
[G]§60.4214(a)(2)Reporting
[G]§60.4214(a)(1)
Is the CI ICE > 130 KW?
Yes
Yes
No
40 CFR Part 60, Subpart IIII(6 of 103)
9
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
§60.4211(b)(1)
You must demonstrate compliance according to oneof the following methods:
9
Comply with the following:Standard
§60.4211(b)
§60.4214(a)
Is the CI ICE > 10 liters per
cylinder?
Is the CI ICE > 10 liters per
cylinder?
By purchasing a certified engine?
Is the CI ICE > 2237
KW?
Comply with the following:Recordkeeping
[G]§60.4214(a)(2)Reporting
[G]§60.4214(a)(1)
Is the CI ICE > 130
KW?
Comply with the following:Standard
§60.4211(b)(1)
Comply with the following:Recordkeeping
[G]§60.4214(a)(2)Reporting
[G]§60.4214(a)(1)
End
Yes
No
Yes
Yes
No
§60.4214(a)
No
No
Yes
Yes
No
§60.4214(a)
§60.4214(a)
40 CFR Part 60, Subpart IIII(7 of 103)
175
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
§60.4211(b)(2)
§60.4211(b)(3)
§60.4211(b)(4)
Comply with the following:Standard
§60.4204(d)Monitoring/Testing
§60.4211(b)(5)[G]§60.4212
175
By keepingrecords of test
results on a similar engine?
Comply with the following:Recordkeeping§60.4211(b)(2)
By keeping records of
manufacturer data?
Comply with the following:Recordkeeping§60.4211(b)(3)
Comply with the following:Recordkeeping§60.4211(b)(4)
By keeping records of control device vendor
data?
Yes
No
No
Yes
Yes
No
End
40 CFR Part 60, Subpart IIII(8 of 103)
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
NMHC+NOx
Emission limit = 7.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
CO
Emission limit = 8.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.80 g/KW-hr
NMHC+NOx
Emission limit = 7.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
COEmission limit =
8.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PM
Emission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
1110
Is the CI ICE a 2014 model year or
earlier?
Comply with the following:Standard§1039.101
Comply with the following:Standard§1039.102
No
Yes
172
The following question will apply to each individual pollutant that has been previously picked up.
§60.4201(a)
40 CFR Part 60, Subpart IIII(9 of 103)
176
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
12
§60.4209(b)
§60.4204(e)
Comply with the following:Standard
§60.4211(e)(1)
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
§60.4211(e)(1)Comply with the following:
Standard§60.4204(d)
Monitoring/Testing§60.4211(e)(2)[G]§60.4212
End
Comply with the following:Standard
§60.4204(e)§60.4211(e)
Comply with the following:Standard§60.4206
§60.4207(b)§60.4218
Opacity
Emission limit = 20% (acceleration)
15% (lugging) 50% (peak acceleration/
lugging)
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Is the CI ICE equipped with a diesel particulate
filter?
Comply with the following:Monitoring/Testing
§60.4209(b)Recordkeeping§60.4214(c)
Is the CI ICE being modified/
reconstructed?
No Yes
All of the following questions/requirements will apply to all individual pollutants that have been
picked up. 15
Is the CI ICE a
2007 model year?
Comply with the following:Standard
§1039.105(b)(1)-(3)
Comply with the following:Standard
§89.113(a)(1)-(3)Yes
No
Yes
No
YesNo
§60.4201(a)
40 CFR Part 60, Subpart IIII(10 of 103)
13
177
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
13Comply with the following:
Standard§60.4211(c)
Is the CI ICEand control device
installed, configured, operated, and maintained according
to manufacturer’s emission-related instructions?
End
Yes
§60.4211(g)
Is the CI ICE < 75
KW?
Is the CI ICE > 75 KW and
< 368 KW?
Comply with the following:Standard
§60.4204(d)§60.4211(g)
Monitoring/Testing[G]§60.4212
No
Comply with the following:Standard
§60.4211(g)(1)Monitoring/Testing
§60.4211(g)(1)Recordkeeping§60.4204(g)(1)
Comply with the following:Standard
§60.4211(g)(2)Monitoring/Testing
§60.4211(g)(2)Recordkeeping§60.4211(g)(2)
Comply with the following:Standard
§60.4211(g)(3)Monitoring/Testing
§60.4211(g)(3)Recordkeeping§60.4211(g)(3)
Yes
No
No
§60.4211(g)(1)
§60.4211(g)(2),(g)(3)
40 CFR Part 60, Subpart IIII(11 of 103)
Comply with the following:Standard
[G]§60.4211(a)
Yes
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
14Is the
CI ICE > 8 KW and < 19 KW?
Is the CI ICE a 2007 model
year?Yes
Is the CI ICE > 19 KW and
< 37 KW?
No
Is the CI ICE a 2007 model
year?
No
Yes Yes
Yes
Is the CI ICE > 37 KW and
< 56 KW?
No
Is the CI ICE a 2007 model
year?Yes Yes
Is the CI ICE a 2008-2012 model
year?
No
Yes
No
No
Is the CI ICE a 2008-2012 model
year?
No
Yes
No
40 CFR Part 60, Subpart IIII(12 of 103)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
33
32
34
35
37
38
39
18
36
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(13 of 103)
Is the CI ICE a 2007 model
year?
18
Is the CI ICE > 56 KW and
< 75 KW?
Is the CI ICE a 2008-2011 model
year?
No
Is the CI ICE a 2012-2013 model
year?
Yes Yes
No
Yes
Yes
Is the CI ICE > 75 KW and
< 130 KW?
No
Is the CI ICE a 2007-2011 model
year?Yes Yes
Is the CIICE a 2012-2013 model
year?
No
Yes
No
No
No
§60.4201(a) §60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
42
43
45
46
37
44
19
41
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(14 of 103)
19
Is the CI ICE > 130 KW and
< 560 KW?
Is the CI ICE a
2007-2010 model year?
No
Is the CI ICE a
2011-2013 model year?
Yes Yes
Yes
No
Is the CI ICE > 560 KW and
< 900 KW?
No
Is the CIICE a 2007-2010 model
year?Yes Yes
Is the CI ICE a 2011-2014 model
year?
No
Yes
Isthe CI ICE a generator-set
engine?
For purposes of 40 CFR 60 Subpart IIII: Generator-set engine is defined
as an engine used primarily to operate an electrical generator/
alternator to produce electric power for other applications.
No
Yes
No
No
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)§60.4201(a)
49
51
47
50
48
20
53
52
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(15 of 103)
20
Is the CI ICE > 900 KW and <
2237 KW?
Is the CI ICE a 2007-2010 model
year?
Is the CI ICE a 2011-2014 model
year?
Yes
No
Yes
Is the CI ICE a generator-set
engine?
For purposes of 40 CFR 60 Subpart IIII: Generator-set engine is defined as an engine used primarily to operate an
electrical generator/alternatorto produce electric power for
other applications.
No
Yes
Is the CI ICE a 2011-2014 model
year?
The CI ICE must be > 2237 KW
No
No
No
Yes
Yes
§60.4201(a) §60.4201(a)
§60.4201(a)
§60.4201(a)
§60.4201(a)
54
50
5355
21
52
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(16 of 103)
21
Is the CI ICE a 2011-2014 model
year?
No
Isthe CI ICE a generator-set
engine?
For purposes of 40 CFR 60 Subpart IIII: Generator-set engine is defined
as an engine used primarily to operate an electrical generator/
alternator to produce electric power for other applications.
No
Is the CI ICE a 2011-2014 model
year?
Yes
Yes
Is the CI ICE a 2007-2010 model
year?Yes
No
Yes
No
§60.4201(b)
§60.4201(c)
§60.4201(c)
57
59
58
56
60
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
22
40 CFR Part 60, Subpart IIII(17 of 103)
Is the CI ICE a
2007-2012 model year?
Is the CI ICE < 600 KW?
No
Is the CI ICE a 2013 model
year?
Is the CI ICE a pre-2007
model year?No Yes
Yes
Is the CI ICE > 600 KW and
< 1400 KW?
No
Is the CI ICE a
2013-2016 model year?
Yes
Is the CI ICE
> 1400 KW and < 2000 KW?
No
Is the CI ICE a 2013-2015 model
year?Yes
Is the CI ICE
> 2000 KW and < 3700 KW?
No
No
Yes
No
No
Yes
§60.4204(a) §60.4201(d)(1)
§60.4201(e)(1), §60.4201(e)(2)
§60.4201(e)(1), (e)(2) §60.4201(e)(1),
(e)(2)
§60.4201(e)(1), (e)(2)
§60.4201(e)(1), (e)(2)
§60.4201(e)(1), (e)(2)
§60.4201(e)(1), (e)(2)
Yes
Yes
Yes
No
61
63
65
66
64
68
67
23
69
70
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(18 of 103)
The CI ICE must be > 3700 KW
23
Is the CI ICE a 2013 model
year?
Is the CI ICE < 3300 KW?
Is the CI ICE a
2014-2015 model year?
Is the CI ICE
> 600 KW and < 1400 KW?
24
Yes
Yes
No
Is the CI ICE a pre-2007
model year?
Is the CI ICE a
2007-2013 model year?
Yes
No
No
Yes
No
Is the CI ICE
< 600 KW?
No
YesNo
Is the CI ICE a
2014-2016 model year?
Is the CI ICE
> 1400 KW and < 2000 KW?
Yes
No
Yes
No
Yes
No
§60.4201(d)(2)
§60.4201(e)(2)
§60.4204(a)
§60.4204(d)(1), (d)(3) §60.4204
(d)(1), (d)(3)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
Yes
72
71
73
61
7475
76
77 66
25
26
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(19 of 103)
2625
Is the CI ICE a
2014-2015 model year?
Is the CI ICE
> 2000 KW and < 3700 KW?
Yes
No
Yes
No
The CI ICE must be > 3700 KW
Is the CI ICE a
2014-2015 model year?
Yes
No
27Is the
CI ICE a pre-2007 model year?
Yes
Is the CI ICE a
2007-2013 model year?
Yes
Is the CI ICE
< 600 KW?
No
Is the CI ICE
> 600 KW and < 1400 KW?
Is the CI ICE a
2014-2016 model year?
No
No
Yes
No
Yes
No
Yes
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4204(a)
§60.4204(d)(1), (d)(3)
78
68
70
79
73
61
80
81
82
66 28No
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(20 of 103)
28Is the CI ICE
> 1400 KW and < 2000 KW?
Is the CI ICE a
2014-2015 model year?
Yes Yes
Is the CI ICE
> 2000 KW and < 3700 KW?
No
YesThe CI ICE must be > 3700 KW
No
Is the CI ICE a
2014-2015 model year?
No
Yes
29Is the
CI ICE a pre-2007 model year?
Yes
Is the CI ICE a
2007-2013 model year?
No
Is the CI ICE
< 600 KW?
No
Yes
Is the CI ICE a
2014-2016 model year?
Is the CI ICE
> 600 KW and < 1400 KW?
NoYes
Yes
No
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2) §60.4201(e)(2)
§60.4201(e)(2)§60.4201(e)(2)
§60.4204(a) §60.4204(d)(1), (d)(3)
§60.4201(e)(2)
No
68
83
79
73
61
85
84
30
66
86
70
Yes
No
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(21 of 103)
30
Is the CI ICE a
2014-2015 model year?
Yes
No
Yes
Is the CI ICE
> 1400 KW and < 2000 KW?
Is the CI ICE a
2014-2015 model year?
Yes
No
Is the CI ICE
> 2000 KW and < 3700 KW?
No
The CI ICE must be > 3700 KW
No
Yes
31
Was the CI ICE installed prior to
01/01/2012?
Yes
No
Yes
No
Was the CI ICE installed on or after 01/01/2012 and before
01/01/2016?
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4201(e)(2)
§60.4204(c)(1)
§60.4204(c)(2)
79
87
73
70
68
88
89
90
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
NMHC+NOx
40 CFR Part 60, Subpart IIII(22 of 103)
NMHC+NOx
32 33
Emission limit = 7.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
CO
Emission limit = 6.6 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.80 g/KW-hr
Emission limit = 7.5 g/KW-hr
CO
Emission limit = 6.6 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PM
Emission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Comply with the following:Standard
§60.4204(b)§60.4201(a)
172
176
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(23 of 103)
34 35NMHC+NOx
Emission limit = 7.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
CO
Emission limit = 5.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.60 g/KW-hr
NMHC+NOx
Emission limit = 7.5 g/KW-hr
CO
Emission limit = 5.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Emission limit = 0.30 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
176
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(24 of 103)
36NMHC+NOx
Emission limit = 4.7 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
CO
Emission limit = 5.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Emission limit = 0.03 g/KW-hr
NMHC+NOx
37
Emission limit = 7.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.40 g/KW-hr
No
The following question will apply to each individual pollutant that has been previously picked up.
§60.4201(a)
177
Is the CI ICE a 2014 model year or
earlier?
Comply with the following:Standard§1039.102
Comply with the following:Standard§1039.101
Yes
176
178
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(25 of 103)
38NMHC+NOx
Emission limit = 4.7 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Emission limit = 0.30 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
39NMHC+NOx
Emission limit = 4.7 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Emission limit = 0.03 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
176 178
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(26 of 103)
41NMHC+NOx
Emission limit = 4.7 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
42NMHC+NOx
Emission limit = 4.7 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Emission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Opacity
Comply with the following:Standard
§60.4204(b)§60.4201(a)
§89.113(a)(1)-(3)
Emission limit = 20% (acceleration)
15% (lugging) 50% (peak acceleration/
lugging)Comply with the following:
Standard§60.4206
§60.4207(b)§60.4218
All of the following questions/requirements will apply to all individual pollutants that have been
picked up.
173
15
179180
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(27 of 103)
43 NMHCEmission limit = 0.19 g/KW-hr
NOxEmission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
COEmission limit =
5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PMEmission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
178
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(28 of 103)
44NMHC+NOx
Emission limit = 4.0 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.30 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
45NMHC+NOx
Emission limit = 4.0 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Emission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
179 180
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
46
40 CFR Part 60, Subpart IIII(29 of 103)
NMHCEmission limit = 0.19 g/KW-hr
NOxEmission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
COEmission limit =
5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PMEmission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
178
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(30 of 103)
47NMHC+NOx
Emission limit = 4.0 g/KW-hr
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.20 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
48NMHC+NOx
Emission limit = 4.0 g/KW-hr
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Emission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
179 177
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(31 of 103)
49 NMHCEmission limit = 0.19 g/KW-hr
NOxEmission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
Comply with the following:Standard
§60.4204(b)§60.4201(a)
PMEmission limit = 0.02 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)
178
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(32 of 103)
50NMHC+NOx
Emission limit = 6.4 g/KW-hr
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
PM
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
Emission limit = 0.20 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§89.112(a)
51 NMHC
Emission limit = 0.40 g/KW-hr
NOx
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PMEmission limit = 0.10 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
179
176
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(33 of 103)
53
52 NMHCEmission limit = 0.19 g/KW-hr
NOx
Emission limit = 0.67 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
PM
Emission limit = 0.03 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
NMHCEmission limit = 0.19 g/KW-hr
NOxEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
PM
Emission limit = 0.04 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.101
177
177
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(34 of 103)
55
54 NMHCEmission limit = 0.40 g/KW-hr
NOx
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Emission limit = 0.10 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
NMHCEmission limit = 0.40 g/KW-hr
NOxEmission limit = 0.67 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
PM
Emission limit = 0.10 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(a)§1039.102
176
176
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(35 of 103)
56 HCEmission limit =
1.3 g/KW-hr
NOxEmission limit =
9.2 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(b)
COEmission limit = 11.4 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(b)
Comply with the following:Standard
§60.4204(b)§60.4201(b)
PMEmission limit = 0.54 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(b)
174
Opacity
Comply with the following:Standard
§60.4204(b)§1039.105(b)(1)-(3)
Emission limit = 20% (acceleration)
15% (lugging) 50% (peak acceleration/
lugging)
62
15
Is the
CI ICE a constant speed
engine?All of the following
questions/requirements will apply to all individual
pollutants that have been picked up.
No
Comply with the following:Standard
§60.4201(c)§60.4206
§60.4207(b)§60.4218
Recordkeeping[G]§60.4214(a)(2)
Reporting [G]§60.4214(a)(1)
181
Yes
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
§89.113(c)(3)§1039.105(a)(2)
40 CFR Part 60, Subpart IIII(36 of 103)
Comply with the following:Standard§60.4206
§60.4207(b)§60.4218
All of the following questions/requirements
will apply to each individual pollutant that
has been picked up.
Is the CI ICE a 2007-2010
model year?
Is the CI ICE > 2237
KW?
Is the displacement of the CI ICE < 10 liters per
cylinder?
Comply with the following:Recordkeeping
[G]§60.4214(a)(2)Reporting
[G]§60.4214(a)(1)
Yes
62
Yes
No
Comply with the following:Recordkeeping
[G]§60.4214(a)(2)Reporting
[G]§60.4214(a)(1)No
No
Yes
§60.4204(a)
§60.4214
§60.4201(c)
12
15
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(37 of 103)
58
57 NMHCEmission limit = 0.40 g/KW-hr
NOx
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
Comply with the following:Standard
§60.4204(b)§1039.102
PM
Emission limit = 0.10 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
NMHCEmission limit = 0.40 g/KW-hr
NOxEmission limit = 0.67 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
Comply with the following:Standard
§60.4204(b)§1039.102
PM
Emission limit = 0.10 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.102
174
174
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(38 of 103)
60
59 NMHCEmission limit = 0.19 g/KW-hr
NOx
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
Comply with the following:Standard
§60.4204(b)§1039.101
PM
Emission limit = 0.04 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
NMHCEmission limit = 0.19 g/KW-hr
NOxEmission limit = 0.67 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
COEmission limit =
3.5 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
Comply with the following:Standard
§60.4204(b)§1039.101
PM
Emission limit = 0.03 g/KW-hr
Comply with the following:Standard
§60.4204(b)§1039.101
181
181
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(39 of 103)
61
NOx
Emission limit = 17.0 g/KW-hr (test speed < 130 rpm), 45.0 x N-0.20 (test speed > 130 and
< 2000 rpm), 9.8 g/KW-hr (test speed > 2000 rpm)
Comply with the following:Standard
§60.4204(a)§94.8(a)(1)(i)-(iii)
63Emission limit =
7.8 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
PMEmission limit = 0.27 g/KW-hr
THC+NOx
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1)§94.8(a)(2)
62
8
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(40 of 103)
64HC+NOx
Emission limit = 6.2 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
65HC+NOx
Emission limit = 6.2 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
PM
Emission limit = 0.14 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(41 of 103)
HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HC+NOx
Emission limit = 6.2 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
PM
Emission limit = 0.14 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1), (e)(2)
§1042.101
66
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
67
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(42 of 103)
62
HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HC+NOx
Emission limit = 7.8 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1)
§1042.101
PM
Emission limit = 0.14 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(1)
§1042.101
68
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
69
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(43 of 103)
HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
THC+NOx
Emission limit = 7.8 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(2)§94.8(a)(2)
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(2)§94.8(a)(2)
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(2)§94.8(a)(2)
70
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
71
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(44 of 103)
73
72 HCEmission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
COEmission limit =
5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
PM
Emission limit = 0.12 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HCEmission limit = 0.19 g/KW-hr
NOxEmission limit =
1.8 g/KW-hr
COEmission limit =
5.0 g/KW-hr
PM
Emission limit = 0.06 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(45 of 103)
Emission limit = 8.7 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
THC+NOx
Emission limit = 9.8 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
74
CO
Emission limit = 5.0 g/KW-hr
75THC+NOx
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(46 of 103)
Emission limit = 7.0 g/KW-hr
PM
Emission limit = 0.34 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
THC+NOx
Emission limit = 7.0 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
PM
Emission limit = 0.34 g/KW-hr
76
CO
Emission limit = 5.0 g/KW-hr
77HC+NOx
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(47 of 103)
Emission limit = 7.0 g/KW-hr
PM
Emission limit = 0.34 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
78
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HC+NOx
79HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.25 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(48 of 103)
80
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
HC+NOx
Emission limit = 9.8 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
81THC+NOx
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(49 of 103)
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
82
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HC+NOx
83HC+NOx
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(50 of 103)
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
84
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(d)(1), (d)(3)
§94.8(a)(2)
THC+NOx
85HC+NOx
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(51 of 103)
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
86
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
HC+NOx
87HC+NOx
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4204(b)§60.4201(e)(2)
§1042.101
62
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(52 of 103)
88
NOx
Emission limits = 17.0 g/KW-hr (test speed < 130 rpm),
45.0 x N-0.20 (test speed > 130 and < 2000 rpm), 9.8 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
[G]§60.4204(c)(1)Monitoring/Testing
§60.4213(e)
PM
89
NOx
Emission limits = 14.4 g/KW-hr (test speed < 130 rpm),
44.0 x N-0.23 (test speed > 130 and < 2000 rpm), 7.7 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
[G]§60.4204(c)(2)Monitoring/Testing
§60.4213(e)
90
NOx
Emission limits = 3.4 g/KW-hr (test speed < 130 rpm),
9.0 x N-0.20 (test speed > 130 and < 2000 rpm), 2.0 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
[G]§60.4204(c)(3)Monitoring/Testing
§60.4213(e)
Are you choosing
to reduce PM emissions by 60% or more?
PMEmission limit = 0.15 g/KW-hr
No
Comply with the following:Standard
§60.4204(c)(4)Monitoring/Testing
[G]§60.4213(d)
Comply with the following:Standard
§60.4204(c)(4)Monitoring/Testing
§60.4213(f)
§60.4204(c)(4)
Yes
91
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(53 of 103)
91
§60.4209(b)
§60.4204(e)
Comply with the following:Standard
§60.4211(e)(1)
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
Comply with the following:Monitoring/Testing
§60.4211(e)(2)
Comply with the following:Standard
§60.4204(e)§60.4211(e)
Is the CI ICE equipped with a diesel particulate
filter?
Comply with the following:Monitoring/Testing
§60.4209(b)Recordkeeping§60.4214(c)
Is the CI ICE being modified/
reconstructed?
All of the following questions/requirements will
apply to each individual pollutant that has been picked
up.
Comply with the following:Standard
§60.4211(d)Monitoring/Testing§60.4211(d)(1), (d)(3)
Recordkeeping[G]§60.4211(d)(2)
Reporting[G]§60.4211(d)(2)
Comply with the following:Standard§60.4206
§60.4207(d)§60.4218
Monitoring/Testing§60.4213(a), (b), (c)
Recordkeeping[G]§60.4214(a)(2)
Reporting[G]§60.4214(a)(1)
No
Yes
No
YesEnd
Yes
No
§60.4211(e)(1)
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(54 of 103)
92 Is the displacement
of the emergency CI ICE > 30 liters per
cylinder?
94
NOx
Emission limits = 17.0 g/KW-hr (test speed < 130 rpm),
45.0 x N-0.20 (test speed > 130 and < 2000 rpm), 9.8 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
[G]§60.4205(d)(1)Monitoring/Testing
§60.4213(e)
PM
NOx
Emission limits = 14.4 g/KW-hr (test speed < 130 rpm),
44.0 x N-0.23 (test speed > 130 and < 2000 rpm), 7.7 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
[G]§60.4205(d)(2)Monitoring/Testing
§60.4213(e)
93
Comply with the following:Standard
§60.4205(d)(3)Monitoring/Testing
§60.4213(f)
§60.4205(d)
Was the CI ICE installed prior to
01/01/2012?
No
Yes
No
Yes
§60.4205(d)(1) §60.4205(d)2)
Emission limit = 0.40 g/KW-hr
All of the following questions/requirements
will apply to each individual pollutant that
has been picked up.
Comply with the following:Standard§60.4206
§60.4207(d)[G]§60.4211(f)
§60.4218Monitoring/Testing§60.4213(a), (b), (c)
Reporting[G]§60.4214(d)
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(55 of 103)
93
§60.4204(e)
Comply with the following:Standard
§60.4211(e)(1)
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
Comply with the following:Monitoring/Testing
§60.4211(e)(2)
Comply with the following:Standard
§60.4205(f)§60.4211(e)
Comply with the following:Monitoring/Testing
§60.4209(a)Recordkeeping§60.4214(b)
Is the CI ICE being modified/
reconstructed?
Comply with the following:Standard
§60.4211(d)Monitoring/Testing
§60.4211(d)(1)Recordkeeping
[G]§60.4211(d)(2)Reporting
[G]§60.4211(d)(2)
End
Does the emergency CI ICE
meet standards applicable to non-emergency
engines?
No
§60.4209(a)
Yes
Yes
Yes
No
No
§60.4211(e)(1)
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(56 of 103)
94
For purposes of 40 CFR 60 Subpart IIII: Fire pump engine is defined as an
emergency engine certified to National Fire Protection Association (NFPA) requirements that is used to provide
power to pump water for fire suppression or protection.
Is the emergency CI ICE a fire pump
engine?Yes
No
Is the CI ICE > 8 KW and
< 19 KW?
Is the CI ICE
< 8 KW?
Is the CI ICE a 2010 model year or
earlier?
Yes
Yes
No
No
Is the CI ICE a 2010 model year or
earlier?
Yes
Yes
No
Is the CI ICE > 19 KW and
< 37 KW?
No
Is the CI ICE a 2010 model year or
earlier?
Yes Yes
NoNo
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
97
111
110
109
112
11395
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(57 of 103)
95
YesIs the CI
ICE > 37 KW and < 75 KW?
Is the CI ICE a 2010 model year or
earlier?
Yes
Is the CI ICE a 2011-2013
model year and has a rated speed of > 2650
rpm?
Are you choosingto alternatively comply with the emission limits for a 2010
model year?
Yes
No
Yes
Is the CI ICE > 75 KW and
< 130 KW?
No
Is the CI ICE a 2009 model year or
earlier?
Yes
Is the CI ICE a 2010-2012
model year and has a rated speed of > 2650
rpm?
Are youchoosing to alternatively
comply with the emission limits for a 2009 model
year?
No
No
No
Yes
No
Yes
No No
Yes
§60.4205(c)
§60.4205(c)§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c) §60.4205(c)
114
115
116
96
117
118 119
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(58 of 103)
96
Is the CI ICE > 130 KW and
< 450 KW?
Is the CI ICE a 2008 model year or
earlier?
Yes Yes
Is the CI ICE a 2009-2011
model year and has a rated speed of > 2650
rpm?
Are youchoosing to alternatively
comply with the emission limits for a 2008 model
year?
Yes
No
Yes
No
No
Is the CI ICE > 450 KW and
< 560 KW?
Is the CI ICE a 2008 model year or
earlier?
No
Yes
Yes
No
The CI ICE must be > 560 KW
No
Is the CI ICE a 2007 model year
or earlier?Yes
No
§60.4205(c)§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
§60.4205(c)
120
120
123
121
124
121
122
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(59 of 103)
97
Is the displacement of the CI
ICE < 10 liters per cylinder?
Is the displacement
of the CI ICE > 10 and< 15 liters per cylinder?
The displacement of the emergency CI ICE must be > 30 liters per cylinder.
No
Is the displacement
of the CI ICE > 15 and< 20 liters per
cylinder?
Is the displacement
of the CI ICE > 20 and< 25 liters per
cylinder?
Is the displacement
of the CI ICE > 25 and< 30 liters per
cylinder?
No
Is the CI ICE a pre-2007
model year?
Yes
Yes
No
No
Is the CI ICE < 8 KW?
Is the CI ICE > 8 KW and
< 37 KW?
Yes
Yes
No
Yes
No
YesYes
No
No
§60.4205(a), (b)
§60.4205(a) §60.4205(a)
§60.4205(a), (b)
§60.4205(a) §60.4205(b)
§60.4205(a), (b)
§60.4205(a) §60.4205(b)
§60.4205(a) §60.4205(b)
107
108
106
92
105
9899
100
103
Yes
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(60 of 103)
98
Comply with the following:Standard
§60.4205(a)-Table 1
NMHC+NOx
Emission limit = 10.5 g/KW-hr
CO
Emission limit = 8.0 g/KW-hr
Comply with the following:Standard
§60.4205(a)-Table 1
PM
Emission limit = 1.0 g/KW-hr
Comply with the following:Standard
§60.4205(a)-Table 1
Comply with the following:Standard
§60.4205(a)-Table 1
NMHC+NOx
Emission limit = 9.5 g/KW-hr
CO
Emission limit = 6.6 g/KW-hr
Comply with the following:Standard
§60.4205(a)-Table 1
Is the CI ICE
< 19 KW?CO
Comply with the following:Standard
§60.4205(a)-Table 1
Emission limit = 5.5 g/KW-hr
No
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(a)-Table 1
Yes
99
101
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(61 of 103)
100 NOxEmission limit =
9.2 g/KW-hr
HC
Comply with the following:Standard
§60.4205(a)-Table 1
Emission limit = 1.3 g/KW-hr
CO
Comply with the following:Standard
§60.4205(a)-Table 1
Emission limit = 11.4 g/KW-hr
PMComply with the following:
Standard§60.4205(a)-Table 1
Emission limit = 0.54 g/KW-hr
Comply with the following:Standard
§60.4205(a)-Table 1
Is the CI ICE > 37 KW and
< 130 KW?
Yes
No
NOx
Emission limit = 17.0 g/KW-hr (test speed < 130 rpm),
45.0 x N-0.20 (test speed > 130 and < 2000 rpm), 9.8 g/KW-hr
(test speed > 2000 rpm)
Comply with the following:Standard
§60.4205(a)§94.8(a)(1)(i)-(iii)
140
§60.4205(a)
101
101
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(62 of 103)
Comply with the following:Standard§60.4206
§60.4207(b)[G]§60.4211(f)
§60.4218Reporting
[G]§60.4214(d)
§60.4204(e)
§60.4211(e)(1)
All of the following questions/requirements
will apply to each individual pollutant that
has been picked up.
101
Comply with the following:Monitoring/Testing
§60.4209(a)Recordkeeping§60.4214(b)
Does the emergency CI ICE
meet standards applicable to non-emergency
engines?
No
§60.4209(a)
Is the CI ICE being modified/
reconstructed?
Yes
Comply with the following:Standard
§60.4205(f)§60.4211(e)
Comply with the following:Standard
§60.4211(e)(1)
No
Yes
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
No
YesEnd
Comply with the following:Standard
§60.4205(e)Monitoring/Testing
§60.4211(e)(2)[G]§60.4212
102
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(63 of 103)
§60.4211(b)(1)
§60.4211(b)(2)
§60.4211(b)(3)
§60.4211(b)(4)
102Comply with the following:
Standard§60.4211(b)
You must demonstrate compliance according to oneof the following methods:
By purchasing a certified
engine?
End
Comply with the following:Standard
§60.4211(b)(1)
By keepingrecords of test
results on a similar engine?
Yes
No
Comply with the following:Recordkeeping§60.4211(b)(2)
Yes
By keeping records of manufacturer
data?
No
Comply with the following:Recordkeeping§60.4211(b)(3)
Yes
By keeping records of control device vendor
data?
No
Comply with the following:Recordkeeping§60.4211(b)(4)
Yes
Comply with the following:Standard
§60.4205(e)Monitoring/Testing
§60.4211(b)(5)[G]§60.4212
No
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(64 of 103)
Is the CI ICE < 8 KW?
103
Is the CI ICE a 2007 model
year?Yes Yes
No
Is the CI ICE > 8 KW and
< 19 KW?
No
Is the CI ICE a 2007 model
year?Yes Yes
No
Is the CI ICE > 19 KW and
< 37 KW?
No
Is the CI ICE a
2007 modelyear?
Yes Yes
No
Is the CI ICE > 37 KW and
< 75 KW?
No
Is the CI ICE a
2007 modelyear?
Yes Yes
No
No
§60.4202(a) §60.4202(a)
§60.4202(a) §60.4202(a)
§60.4202(a)§60.4202(a)
§60.4202(a) §60.4202(a)
132
133
134
104
128
127
130
131
129
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(65 of 103)
Is the CI ICE > 75 KW and
< 130 KW?
Is the CI ICE a 2007-2010 model
year?
No
Yes
Is the CI ICE > 130 KW and
< 560 KW?Yes
Is the CI ICE > 560 KW and
< 2237 KW?
No
Yes
The emergency CI ICE that is < 10 liters per cylinder
must be > 2237 KW
No
Yes
No
104
§60.4202(a)
§60.4202(a)
§60.4202(a)
§60.4202(b)
136
135
139
137
138
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(66 of 103)
105
Is the CI ICE a pre-2007 model year?
Is the CI ICE a 2007-2012
model year?No
Is the CI ICE < 600
KW?
Is the CI ICE
> 600 KW and < 1400 KW?
Is the CIICE a 2013-2016
model year?
No
Yes
Is the CI ICE
> 1400 KW and < 2000 KW?
Is the CI ICE a 2013-2015
model year?
Yes
No
No
No
Yes
Yes
Yes
NoIs the CI ICE
> 2000 KW and < 3700 KW?
No
Is the CI ICE a 2013 model year?
Yes
The CI ICE must be > 3700 KW
No
Yes
§60.4205(a)§60.4202(e)(1)
§60.4202(f)(1)
§60.4202(f)(1)
§60.4202(f)(1)
§60.4202(f)(1)
§60.4202(f)(1)
§60.4202(f)(1)
§60.4202(f)(1)
Yes Yes
No
141140
147
146145
143
142
149
144
148
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(67 of 103)
106
Yes
Yes
Is the CI ICE a pre-2007
model year?
Is the CI ICE a 2007-2012
model year?No
Is the CI ICE a 2013 model year?
Is the CI ICE < 3300 KW?
No
Yes
No
Is the CI ICE < 600 KW?
No
Is the CI ICE
> 600 KW and < 1400 KW?
Is the CI ICE a 2014-2016
model year?
No
Yes
No
Is the CI ICE
> 1400 KW and < 2000 KW?
Is the CI ICE a 2014-2015
model year?
Is the CI ICE
> 2000 KW and < 3300 KW?
No
Yes
Yes
No
The CI ICE must be
> 3300 KW
Yes
No
Yes
Yes
No
§60.4205(a) §60.4202(e)(1)
§60.4202(e)(3)§60.4202(e)(3)
§60.4202(f)(2)§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(e)(4)
Yes
151
155
158
152156
144
150
140
146
153
154
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(68 of 103)
107
No YesIs the
CI ICE a pre-2007 model year?
Yes
Is the CIICE a 2007-2013
model year?
Is the CI ICE < 600
KW?
Is the CI ICE > 600 KW and
< 1400 KW?
Is the CI ICE a 2014-2016
model year?
Yes
No
Yes
Yes
No
Is the CI ICE > 1400 KW and
< 2000 KW?
No
Is the CI ICE a 2014-2015
model year?
Yes
Yes
No
The CI ICE must be > 2000 KW
No
No
§60.4202(e)(1), (e)(3)
§60.4202(f)(2)
§60.4205(a)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
162
161
144
164
163
146
159
140
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(69 of 103)
108
No
Yes
Is the CI ICE a pre-2007
model year?
Yes
Is the CI ICE a 2007-2013
model year?
Is the CI ICE < 600 KW?
Is the CI ICE > 600 KW and
< 1400 KW?
Is the CI ICE a 2014-2016
model year?
Yes
No
Yes
Yes
No
Is the CI ICE > 1400 KW and
< 2000 KW?
No
Is the CI ICE a 2014-2015
model year?
Yes
Yes
NoThe CI ICE must be > 2000 KW
No
No§60.4202(e)(1), (e)(3)
§60.4205(a)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
§60.4202(f)(2)
166
167
144
169
168
146
165140
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(70 of 103)
109
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 1.0 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
CO
Emission limit = 8.0 g/KW-hr
110NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(71 of 103)
111
Emission limit = 9.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 9.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
CO
Emission limit = 6.6 g/KW-hr
112NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
CO
Emission limit = 5.5 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
101
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(72 of 103)
113
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.30 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
114NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(73 of 103)
115
Emission limit = 4.7 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
116NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4-fn1
Comply with the following:Standard
§60.4205(c)-Table 4-fn1
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4-fn1
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(74 of 103)
117
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 4.0 g/KW-hr
PM
Emission limit = 0.30 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
118NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(75 of 103)
119
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4-fn2
NMHC+NOx
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.54 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
120NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4-fn2
Comply with the following:Standard
§60.4205(c)-Table 4-fn2
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
101125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(76 of 103)
121
Emission limit = 4.0 g/KW-hr
PM
Emission limit = 0.20 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.54 g/KW-hr
122NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4-fn3
Comply with the following:Standard
§60.4205(c)-Table 4-fn3
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4-fn3
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(77 of 103)
123
Emission limit = 10.5 g/KW-hr
PM
Emission limit = 0.54 g/KW-hr
Comply with the following:Standard
§60.4205(c)-Table 4
NMHC+NOx
Emission limit = 6.4 g/KW-hr
PM
Emission limit = 0.20 g/KW-hr
CO
Emission limit = 3.5 g/KW-hr
124NMHC+NOx
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
Comply with the following:Standard
§60.4205(c)-Table 4
125
101
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(78 of 103)
125
§60.4204(e)
§60.4211(e)(1)
All of the following questions/requirements
will apply to each individual pollutant that
has been picked up.
Comply with the following:Monitoring/Testing
§60.4209(a)Recordkeeping§60.4214(b)
Does the emergency CI ICE
meet standards applicable to non-emergency
engines?
No
§60.4209(a)
Is the CI ICE being modified/
reconstructed?
Yes
Comply with the following:Standard
§60.4205(f)§60.4211(e)
Comply with the following:Standard
§60.4211(e)(1)
No
Yes
Are you demonstrating
compliance by purchasing, or otherwise owning/operating
a certified engine?
126 No
YesEnd
Comply with the following:Standard
§60.4205(e)Monitoring/Testing
§60.4211(e)(2)[G]§60.4212
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
Comply with the following:Standard§60.4206
§60.4207(b)[G]§60.4211(f)
§60.4218Reporting
[G]§60.4214(d)
126Comply with the following:
Standard§60.4211(c)
Is the CI ICE and control device installed, configured,
operated, and maintained according to manufacturer’s emission-
related instructions?
End
Yes
§60.4211(g)
Is the CI ICE < 75 KW?
Is the CI ICE > 75 KW and
< 368 KW?
Comply with the following:Standard
§60.4211(g)Monitoring/Testing
[G]§60.4212
No
Comply with the following:Standard
§60.4211(g)(1)Monitoring/Testing
§60.4211(g)(1)Recordkeeping§60.4211(g)(1)
Comply with the following:Standard
§60.4211(g)(2)Monitoring/Testing
§60.4211(g)(2)Recordkeeping§60.4211(g)(2)
Comply with the following:Standard
§60.4211(g)(3)Monitoring/Testing
§60.4211(g)(3)Recordkeeping§60.4211(g)(3)
Yes
No
No
§60.4211(g)(1)
§60.4211(g)(2),(g)(3)
40 CFR Part 60, Subpart IIII(79 of 103)
Comply with the following:Standard
[G]§60.4211(a)
Yes
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(80 of 103)
127
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
NMHC+NOx
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
CO
Emission limit = 8.0 g/KW-hr
128NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
CO
Emission limit = 8.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
170 125
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(81 of 103)
129
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.80 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
NMHC+NOx
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
CO
Emission limit = 6.6 g/KW-hr
130NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
CO
Emission limit = 6.6 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
170
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(82 of 103)
131
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.60 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
NMHC+NOx
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.30 g/KW-hr
CO
Emission limit = 5.5 g/KW-hr
132NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(i)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
CO
Emission limit = 5.5 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
Comply with the following:Standard
§60.4205(b)§60.4202(a)(1)(ii)
§60.4202(a)(1)(ii)-Table 2
170 125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(83 of 103)
133
Emission limit = 7.5 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
NMHC+NOx
Emission limit = 4.7 g/KW-hr
PM
Emission limit = 0.40 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
134NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
170
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(84 of 103)
135
Emission limit = 4.0 g/KW-hr
PM
Emission limit = 0.30 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
NMHC+NOx
Emission limit = 4.0 g/KW-hr
PM
Emission limit = 0.20 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
136NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
CO
Emission limit = 3.5 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
170
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(85 of 103)
Emission limit = 6.4 g/KW-hr
PM
Emission limit = 0.20 g/KW-hr
137
CO
Emission limit = 3.5 g/KW-hr
NMHC+NOx
138HC
Emission limit = 1.3 g/KW-hr
NOx
Emission limit = 9.2 g/KW-hr
PM
Emission limit = 0.54 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(b)(1)-Table 1
CO
Emission limit = 11.4 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(a)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(b)(1)-Table 1
Comply with the following:Standard
§60.4205(b)§60.4202(b)(1)-Table 1
Comply with the following:Standard
§60.4205(b)§60.4202(b)(1)-Table 1
170125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
139
Emission limit = 6.4 g/KW-hr
PM
Emission limit = 0.20 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(b)(2)
§89.112(a)
CO
Emission limit = 3.5 g/KW-hr
NMHC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(b)(2)
§89.112(a)
Comply with the following:Standard
§60.4205(b)§60.4202(b)(2)
§89.112(a)
40 CFR Part 60, Subpart IIII(86 of 103)
157
Comply with the following:Standard
§60.4202(f)(1)
Comply with the following:Standard
§60.4202(f)(2)
Is the displacement
of the CI ICE > 10 and< 15 liters per cylinder?
Yes
No
160
Comply with the following:Standard
§60.4202(e)(3)
Comply with the following:Standard
§60.4202(e)(1)
Is the CI ICE a 2013 model
year?Yes
No
§60.4202(f)(1)§60.4202(f)(2)
§60.4202(e)(1)§60.4202(e)(3)
125
125
170
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(87 of 103)
141
Emission limit = 7.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
HC+NOx
Emission limit = 6.2 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
142THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(88 of 103)
Emission limit = 6.2 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
143
CO
Emission limit = 5.0 g/KW-hr
HC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
144 HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
157125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(89 of 103)
Emission limit = 6.2 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
145
CO
Emission limit = 5.0 g/KW-hr
HC+NOx
146 HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
Comply with the following:Standard
§60.4205(b)§1042.101
157125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(90 of 103)
Emission limit = 7.8 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
147
CO
Emission limit = 5.0 g/KW-hr
HC+NOx
148 HC
Emission limit = 0.19 g/KW-hr
NOx
Emission limit = 1.8 g/KW-hr
PM
Emission limit = 0.04 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(1)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
149Emission limit =
7.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(2)§94.8(a)(2)
CO
Emission limit = 5.0 g/KW-hr
THC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(e)(2)§94.8(a)(2)
40 CFR Part 60, Subpart IIII(91 of 103)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(2)§94.8(a)(2)
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(92 of 103)
150
Emission limit = 8.7 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
THC+NOx
Emission limit = 8.7 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
151THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(1)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(93 of 103)
152
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
THC+NOx
Emission limit = 8.7 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
153THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(3)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(94 of 103)
154
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
HC+NOx
Emission limit = 6.2 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
155THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(95 of 103)
156
Emission limit = 6.2 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
HC+NOx
Emission limit = 7.8 g/KW-hr
PM
Emission limit = 0.14 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
158HC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(96 of 103)
159
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
HC+NOx
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
161THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101160
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(97 of 103)
162
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
HC+NOx
Emission limit = 9.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
163THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(98 of 103)
164Emission limit =
9.8 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
HC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(99 of 103)
165
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
THC+NOx
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.50 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
166THC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
Comply with the following:Standard
§60.4205(b)§60.4202(e)(4)§94.8(a)(2)
160 125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(100 of 103)
167
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
HC+NOx
Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
CO
Emission limit = 5.0 g/KW-hr
168HC+NOx
CO
Emission limit = 5.0 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(101 of 103)
169Emission limit = 11.0 g/KW-hr
PM
Emission limit = 0.27 g/KW-hr
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
CO
Emission limit = 5.0 g/KW-hr
HC+NOx
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
Comply with the following:Standard
§60.4205(b)§60.4202(f)(2)
§1042.101
125
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(102 of 103)
170
Opacity
Emission limit = 20% (acceleration) 15% (lugging) 50% (peak acceleration/lugging)
Comply with the following:Standard
§60.4205(b)
Is the CI ICE a 2007 model
year?
Comply with the following:Standard
§60.4202(a)(1)(i)§89.113(a)(1)-(3)
Comply with the following:Standard
§60.4202(a)(1)(ii)§1039.105(b)(1)-(3)
Is the CI ICE
< 37 KW?
Comply with the following:Standard
§60.4202(a)(2)
§60.4202(a)(1)
§60.4202(a)(1)(i)
125
Is the CI ICE a constant speed
engine?
Yes
§89.113(c)(3)§1039.105(a)(2)
Is the CI ICE > 2237 KW?
§60.4202(b)
Comply with the following:Standard
§60.4202(b)(2)
No
Yes
Comply with the following:Standard
§89.113(a)(1)-(3)No
Yes
No
No
Yes
06/20/2016 From 40 CFR Part 60, Subpart IIII, Amended 02/27/2014These flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***
40 CFR Part 60, Subpart IIII(103 of 103)
Is the
CI ICE a constant speed
engine?
176
177
12
Yes
No
Is the
CI ICE a constant speed
engine?
179
180
173
Yes
No
§89.113(c)(3)§1039.105(a)(2)
§89.113(c)(3)§1039.105(a)(2)