Td Altosonicv12 en 130226

Embed Size (px)

Citation preview

  • 7/28/2019 Td Altosonicv12 en 130226

    1/12

    ALTOSONIC V12 Technical Datasheet

    12-chord ultrasonic gas flowmeter for custody transfer

    10-reflection chords for the highest possible accuracy; 2-reflection chords for

    extra diagnosis options Built-in redundancy through dynamic chord substitution

    Performance monitoring and fouling detection

  • 7/28/2019 Td Altosonicv12 en 130226

    2/12

    ALTOSONIC V12

    2 www.krohne-oilandgas.com

    Ultrasonic gas owmeter for custody transfer

    As times change, so do the requirements for ultrasonic meters. Today it is assumed that an ultrasonic device

    measures accurately and precisely, but what about long-term reliability? After all, this depends on morethan just the ultrasonic meter itself. The transferred effect of the high pressure calibration on the installationconditions in the measuring station and dirt, which may collect on the meter over time, can also have anegative effect.

    The unique chord arrangement of the ALTOSONIC V12 enables it to generate diagnostic data for placeswhere traditional ultrasonic meters gathered too little information or none at all: rstly at the pipe wall itself,scanning with reection. Secondly, in close proximity to the pipe wall, using the geometrical arrangement ofthe outer chords. Thirdly, at the bottom of the pipe. This data is gathered using a separate diagnostic chord.

    This extremely extensive diagnostic data allows the ALTOSONIC V12 to carry out self-monitoring, which setsthe standard for other devices in terms of performance monitoring.

    Highlights

    12-chord design

    High reliability with built-in redundancy

    Swirl compensation in each measuring plane

    Transducer replacement under pressure

    Bi-directional ow measurement

    Fully encapsulated cabling

    Field display for main functions

    Industries

    Oil & Gas

    Petrochemical

    Applications

    Offshore FPSO and platforms

    Onshore exploration

    Transmission

    Underground gas storage (UGS)

    Distribution

    Large gas intakes, for example for

    power stations, petrochemical industry,

    aluminium smelters, etc.

  • 7/28/2019 Td Altosonicv12 en 130226

    3/12

    3www.krohne-oilandgas.com

    ALTOSONIC V12

    Where traditional ultrasonic owmeters typically require 10D straight inlet piping with a ow conditioner or20D without a ow conditioner, ALTOSONIC V12 only requires 5D with ow conditioner or 10D without owconditioner. This not only minimizes the weight and footprint of the installation, but also saves on installationcosts and shipping costs, both during new installation as well as during re-calibration.

    This much shorter installation length permits planning of more compact new metering runs and slot-inreplacement of conventional meters such as turbines during revamps.

    Without Flow Conditioner

    With KROHNE Flow Conditioner

    Under specic conditions ALTOSONIC V12 can be installed with just 5Dand no ow conditioner, please consult KROHNE if this option is required.

    Inlet / outlet run requirements

  • 7/28/2019 Td Altosonicv12 en 130226

    4/12

    ALTOSONIC V12

    4 www.krohne-oilandgas.com

    FunctionsDevice Ultrasonic gas owmeter

    Description ALTOSONIC V12 consists of a meter body with ultrasonic transducersand a converter box for signal processing and counter display mountedon top of the meter body .

    Measurement functionality Actual volume ow rate and totalized volume; uni- and bi-directional

    Applications Natural gas with a minimum of 75% methane; other applications onrequest

    Nominal diameter[mm] 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 750, 900, 1000,1200,

    1400, 1600, other diameters on request[inches] 4", 6", 8", 10", 12", 14", 16", 18", 20", 24", 30", 36", 40", 42", 48", 56",

    64", other diameters on request

    Measurement accuracyAccuracy (relative to calibrationfacility)

    0.2% of measured value, high-pressure ow calibrated 0.1% of measured value, high-pressure ow calibrated andlinearized

    Repeatability 0.1%

    Operating conditionsFlow range See ow table

    Pressure range 1...450 bar / 0.1...45 MPa / 15...6525 psi (ASME 150 2500)

    Ambient temperature -40...+60C / -40+140F

    Process temperature -20...+70C / -4+158F(-40+100C / -40+212F optional)

    Wet gas content Typically 1% LVF,contact KROHNE for detailed sizing

    CO2

    content Depending on diameter and pressure,contact KROHNE for detailed sizing

    Minimum pressure requirement Depending on diameter and CO2

    concentration,contact KROHNE for detailed sizing

    MaterialsFlanges Low temperature carbon steel A350 LF2,

    (stainless steel and duplex optional)

    Measuring tube Low temperature carbon steel A350 LF2 ( 14") or A333 GR6 ( 16"),(stainless steel and duplex optional)

    Electronics housing Stainless steel 316

    Finish Outside: 3-layer epoxy coating RAL 9006 (silver)Inside: corrosion preservative oil lmOther outside nishes available on request

  • 7/28/2019 Td Altosonicv12 en 130226

    5/12

    5www.krohne-oilandgas.com

    ALTOSONIC V12

    Electrical connectionPower supply 24 VDC / 10 W (without integrated diagnostics board)

    24 VDC / 17 W (with integrated diagnostics board)

    Inputs / OutputsWithout integrated diagnostics board With integrated diagnostics board

    Digital outputSerial

    EthernetAnalog OutputInput

    4x output2x modbus over RS 485 (individuallycongurable)

    5x output3x modbus over RS 485 (individuallycongurable) 2x Ethernet1x 4-20 mA1x multidrop (dual) HART

    ApprovalsCustody transfer OIML R137 class 0.5 by NMi

    MID (Measurement Instrument Directive 2004/22/EC) by NMiFully complaint with AGA 9 and ISO 17089

    Hazardous Area ATEX:IECEx:CSA:

    FM:

    FM:

    II 2G Ex de ma IIB T5Ex de ma IIB T5 GbClass I, Div 1 and 2, Groups B,C,D T6 T4and Class II, Div 1 and 2, Groups E,F,GClass 1, Div 2, Groups C, D T5and Class II, Div 1, Groups E, F, G (Type 4x)Class 1, Zone 1, Aex de ma IIB T5, IP66

    Protection IP 66NEMA 4x

    VerificationsHigh pressure hydrostatic pressure teston meter body

    Standard

    Factory Acceptance Test (FAT) Standard

    Low pressure leakage test on nitrogenon complete meter

    Standard

    High pressure leakage test on nitrogenon complete meter

    Optional

    High-pressure ow calibration Optional

  • 7/28/2019 Td Altosonicv12 en 130226

    6/12

    ALTOSONIC V12

    6 www.krohne-oilandgas.com

    [mm] c min. c max. i H2 L W Weight[kg]

    ASME150

    100 102 107 96 520 400* 330 151

    150 154 160 144 570 450 380 238

    200 202 207 191 620 600 430 351

    250 254 261 239 660 750 470 498

    300 303 312 284 740 900 540 719

    350 333 340 312 780 1050 570 911

    400 381 391 358 840 1200 620 420

    450 428 442 405 890 1350 670 529

    500 477 489 448 940 1500 720 709600 574 591 540 1050 1800 820 1113

    Dimensions and weights (metric)

    [mm] c min. c max. i H2 L WWeight

    [kg]

    ASME600

    100 97 105 96 520 400 330 168

    150 146 158 144 575 450 375 271

    200 193 205 191 630 600 425 411

    250 242 258 239 710 750 510 618

    300 289 308 284 780 900 560 850

    350 317 337 312 815 1050 610 1070

    400 363 388 358 880 1200 690 640

    450 409 435 405 930 1350 740 805

    500 455 483 448 1000 1500 820 1055

    600 547 581 540 1100 1800 940 1621

    [mm] c min. c max. i H2 L WWeight

    [kg]

    ASM

    E300

    100 102 107 96 520 400* 330 158

    150 154 160 144 570 450 380 248

    200 202 207 191 620 600 430 371

    250 254 261 239 680 750 470 533

    300 303 312 284 760 900 540 755

    350 333 340 312 810 1050 590 1008

    400 381 391 358 870 1200 650 520

    450 428 442 405 920 1350 720 659

    500 477 489 448 980 1500 780 862

    600 574 591 540 1100 1800 920 1354

    *300 mm (11,81 inch) available on requestMeters 6 and 900# are standard equipped with transducers that are retractable under pressureValues are provided as indication and might vary slightly with different schedule sizes.Values for larger diameters are available on request.

  • 7/28/2019 Td Altosonicv12 en 130226

    7/12

    7www.krohne-oilandgas.com

    ALTOSONIC V12

    [inch] c min. c max. i H2 L WWeight

    [lbs]

    ASM

    E300

    4 4.02 4.21 3.78 20.47 15,75* 12.99 348

    6 6.06 6.30 5.67 22.44 17.72 14.96 547

    8 7.95 8.15 7.52 24.41 23.62 16.93 818

    10 10.00 10.28 9.41 26.77 29.53 18.50 1175

    12 11.93 12.28 11.18 29.92 35.43 21.26 1665

    14 13.11 13.39 12.28 31.89 41.34 23.23 2223

    16 15.00 15.39 14.09 34.25 47.24 25.59 1147

    18 16.85 17.40 15.94 36.22 53.15 28.35 1453

    20 18.78 19.25 17.64 38.58 59.06 30.71 1901

    24 22.60 23.27 21.26 43.31 70.87 36.22 2986

    [inch] c min. c max. i H2 L WWeight

    [lbs]

    ASME600

    4 3.82 4.13 3.78 20.47 15.75 12.99 370

    6 5.75 6.22 5.67 22.64 17.72 14.76 598

    8 7.60 8.07 7.52 24.8 23.62 16.73 906

    10 9.53 10.16 9.41 27.95 29.53 20.08 1363

    12 11.38 12.13 11.18 30.71 35.43 22.05 1874

    14 12.48 13.27 12.28 32.09 41.34 24.02 2359

    16 14.29 15.28 14.09 34.65 47.24 27.17 1411

    18 16.10 17.13 15.94 36.61 53.15 29.13 1775

    20 17.91 19.02 17.64 39.37 59.06 32.28 2326

    24 21.54 22.87 21.26 43.31 70.87 37.01 3574

    [inch] c min. c max. i H2 L W Weight[lbs]

    ASME150

    4 4.02 4.21 3.78 20.47 15,75* 12.99 333

    6 6.06 6.30 5.67 22.44 17.72 14.96 525

    8 7.95 8.15 7.52 24.41 23.62 16.93 774

    10 10.00 10.28 9.41 25.98 29.53 18.50 1098

    12 11.93 12.28 11.18 29.13 35.43 21.26 1585

    14 13.11 13.39 12.28 30.71 41.34 22.44 2009

    16 15.00 15.39 14.09 33.07 47.24 24.41 926

    18 16.85 17.40 15.94 35.04 53.15 26.38 1166

    20 18.78 19.25 17.64 37.01 59.06 28.35 156324 22.60 23.27 21.26 41.34 70.87 32.28 2454

    Dimensions and weights (imperial)

    *300 mm (11,81 inch) available on requestMeters 6 and 900# are standard equipped with transducers that are retractable under pressureValues are provided as indication and might vary slightly with different schedule sizes.Values for larger diameters are available on request.

  • 7/28/2019 Td Altosonicv12 en 130226

    8/12

    ALTOSONIC V12

    8 www.krohne-oilandgas.com

    Dimensions and weights (metric)

    [mm] c min. c max. i H2 L WWeight

    [kg]

    ASME1500

    100 97 103 96 530 500 340 221

    150 146 155 144 600 600 400 434

    200 193 203 191 660 800 480 652

    250 242 255 239 760 750 580 1030

    300 289 304 284 860 900 660 1507

    Meters

    6 and

    900# are standard equipped with transducers that are retractable under pressureValues are provided as indication and might vary slightly with different schedule sizes.Values for larger diameters are available on request.

    [mm] c min. c max. i H2 L W Weight[kg]

    ASME900

    100 97 103 96 520 400 330 176

    150 146 155 144 590 600 390 324

    200 193 203 191 660 600 470 464

    250 242 255 239 730 750 550 684

    300 289 304 284 810 900 610 957

    350 317 334 312 840 1050 650 1190

    400 363 381 358 890 1200 710 720

    450 409 429 405 960 1350 790 964

    500 455 478 448 1020 1500 860 1254600 547 575 540 1160 1800 1050 2200

    [mm] c min. c max. i H2 L WWeight

    [kg]

    ASME2500

    100 97 103 96 574 500 390 298

    150 146 155 144 681 750 490 658

    200 193 203 191 729 800 550 946

    250 242 255 239 844 1000 670 1664

    300 289 304 284 947 1200 750 2359

  • 7/28/2019 Td Altosonicv12 en 130226

    9/12

    9www.krohne-oilandgas.com

    ALTOSONIC V12

    [inch] c min. c max. i H2 L WWeight

    [lbs]

    ASME2500

    4 3.82 4.06 3.78 22.60 19.69 15.35 657

    6 5.75 6.10 5.67 26.81 29.53 19.29 1451

    8 7.60 7.99 7.52 28.70 31.50 21.65 2086

    10 9.53 10.04 9.41 33.23 39.37 26.38 3669

    12 11.38 11.97 11.18 37.28 47.24 29.53 5202

    Dimensions and weights (imperial)

    [inch] c min. c max. i H2 L WWeight

    [lbs]

    ASME1500

    4 3.82 4.06 3.78 20.87 19.69 13.39 487

    6 5.75 6.10 5.67 23.62 23.62 15.75 957

    8 7.60 7.99 7.52 25.98 31.5 18.90 1438

    10 9.53 10.04 9.41 29.92 29.53 22.83 2271

    12 11.38 11.97 11.18 33.86 35.43 25.98 3323

    [inch] c min. c max. i H2 L W Weight[lbs]

    ASME900

    4 3.82 4.06 3.78 20.47 15.75 12.99 388

    6 5.75 6.10 5.67 23.23 23.62 15.35 714

    8 7.60 7.99 7.52 25.98 23.62 18.50 1023

    10 9.53 10.04 9.41 28.74 29.53 21.65 1508

    12 11.38 11.97 11.18 31.89 35.43 24.02 2110

    14 12.48 13.15 12.28 33.07 41.34 25.59 2624

    16 14.29 15.00 14.09 35.04 47.24 27.95 1588

    18 16.10 16.89 15.94 37.8 53.15 31.10 2126

    20 17.91 18.82 17.64 40.16 59.06 33.86 276524 21.54 22.64 21.26 45.67 70.87 41.34 4851

    Meters

    6 and

    900# are standard equipped with transducers that are retractable under pressureValues are provided as indication and might vary slightly with different schedule sizes.Values for larger diameters are available on request.

  • 7/28/2019 Td Altosonicv12 en 130226

    10/12

    ALTOSONIC V12

    10 www.krohne-oilandgas.com

    Flow Table

    Size [mm]nom.

    Size [inch]nom.

    Qmin Qmax Qmin Qmax[m3/h] [cf/h]

    100 4 25 1,000 900 35,300

    150 6 45 2,300 1,600 81,200

    200 8 75 4,100 2,600 145,000

    250 10 110 6,200 3,900 219,000

    300 12 140 8,200 4,900 290,000

    350 14 170 9,700 6,000 343,000

    400 16 210 11,700 7,400 413,000

    450 18 240 13,900 8,500 491,000

    500 20 260 15,700 9,200 554,000600 24 285 21,400 10,100 756,000

    750 30 450 30,900 15,900 1,091,000

    900 36 650 44,500 23,000 1,572,000

    1000 40 800 54,900 28,300 1,939,000

    1050 42 880 58,000 31,100 2,048,000

    1200 48 1,200 75,800 42,400 2,677,000

    1400 56 1,600 94,200 56,500 3,327,000

    1600 64 2,100 117,000 74,200 4,132,000

    Qt as per ISO 17089 (Vt=3 m/s Sch 80 values might vary slightlyCalculations are provided as indication, please ask KROHNE for detailed sizing.

  • 7/28/2019 Td Altosonicv12 en 130226

    11/12

    11www.krohne-oilandgas.com

    ALTOSONIC V12

  • 7/28/2019 Td Altosonicv12 en 130226

    12/12

    Contact

    Head ofce KROHNE Oil & GasKROHNE Oil & Gas B.V.Minervum 74414817 ZG LH BredaThe NetherlandsTel.: +31 76 711 200 0Fax: +31 76 711 200 [email protected]

    Global companies and representativesThe current list of allKROHNE contacts andaddresses can be found at:www krohne-oilandgas com

    KROHNE Oil & Gas

    Overview

    Systems

    Flowmeters for custody transfer

    Liquid owmetering systems

    Gas owmetering systems

    Wet gas metering systems

    Provers & master meters

    Flow computing, supervisory software &

    analyzer management

    Calibration systems

    Tank inventory & management systems

    Analyzer houses and shelters

    Loading & off-loading systems

    Leak detection and localisation systems

    Revamps & upgrades

    Testing, installation, commissioning,

    service training

    Products

    Gas ultrasonic owmeters for custody transfer

    Liquid ultrasonic owmeters for custody transfer

    Mass owmeters for custody transfer

    Venturis for wet gas metering

    Prover sphere detectors

    Flow computers

    Supervisory systems

    Meter validation software packages

    Electromagnetic owmeters

    Level measuring instruments

    Variable area owmeters

    Temperature measuring instruments

    Pressure measuring instruments

    Analyzers

    Vortex owmeters

    Flow controllers

    K

    ROHNE03/2013-Allrightsreserved

    Subjecttochangewithoutn

    otice-Errorsandomissionsexcepted