    TIME DELAY RELAYProduct TDE-U200 series

    2-pole delay-off timer relay Country of Origin: The Netherlands

    Dimensions Company

    P.O. Box 70233502 KA Utrecht

    The Netherlands

    T +31 (0)30-288 13 11

    F +31 (0)30-289 88 16

    E [email protected]

    I www.nieaf-smitt.nl/railway

    Connection Diagram

    DescriptionElectronic plug-in delay-off railway timer-relay with one change-over contact and one NO contact.

    Equiped with one LED that indicates energization .

    The delay-off time is adjustable with a lockable knob. Fixed times are possible. (No knob)

    The TDE-U200 does not need auxill iary supply .

    The TDE-U200 relays are pluggable in to standard D-U relay bases.

    Coil Data (DC) Timing diagram

    Type Unom (V) Umin (V) Umax (V)TDE-U201 24 16.8 30

    TDE-U202 48 33.6 60 supply

    TDE-U203 72 50.4 90

    TDE-U204 110 77.0 138 contacts

    TDE-U205 96 67.2 120 t offTDE-U207 36 25.2 45

    Nom. powerconsumption < 1.5 W at Unom

    Release time depending on set value of the drop-out time

    Standard time ranges, 0.1 - 1 s 0.3 - 3s 1 - 10 s 3 - 30 s 10 - 100 s

    adjustable

    Adjustment accuracy < 10%

    Repeat accuracy 2 %

    Time var iat ion vs vol tage var iat ion 0.1 %/ % Unom

    vs temperature variation 0.2 % / K

    Recovery time < 0.3 s

    Pull-in time < 40 ms

    Max permissible ripple 24 % Unom

    Min permissible residual voltage 5 % Unom

    11

    12

    76

    40

    5

    6

    1

    2

    3

    4

    7

    8

    9

    10

    13

    13

    14

    NIEAF-SMITT 617650000.TSP-01 18-02-2005

  • 7/27/2019 tde-u200

    2/3

    Contact dataMax. Make Current 15 A Material Ag + 0.2 m Au

    Nom. Current 6 A (AC1 ; IEC 60947) Contactgap 0.3 mm

    Max. Breaking Capacity Insulation between 1 kV,

    DC 300 V,300 mA open contacts 50 Hz, 1 min

    AC 250 V, 2.6 A Contactforce > 20 cN

    Min. Contact continuity 4V/2mA/0.1W-VA Note: contacts cannot have a different

    Max. Contact Resistance 15 m (ini tial) posit ion. (Forced contacts, Weld no transfer)Maximum Switching Capacity and Contact life

    General DataDielectric strength

    Pole-Pole EN 50155 2 kV, 50 Hz, 1 min

    Cont-Coil IEC 60077 2 kV, 50 Hz, 1 min

    Pulse Withstanding IEC 60255-5 5 kV ( 1.2/50 s )

    Vibration IEC 60077 5 g at 50 Hz

    IEC 60571 2 g at 10 - 150 Hz

    EN 50155

    Shock IEC 60077 5 g at 50 Hz

    Mechanical life 30*106

    ops

    Max. Switching Frequency 1200 ops/h

    Weight 140 g

    Temperature Tamb,max +70 C

    Tamb,min -25 C

    Humidity 80%, condensation not permitted

    Protection IP 40

    Materials Makrolon

    Melamine Polyester

    OptionsB Magnetic arc blowout

    E Gold plated contacts

    K Special dust protection (only for fixed time setting)U Double make contact

    Max Switch ing Capacity

    10

    100

    1000

    10 100 1000

    Volt

    Watt

    DC

    1 contact

    DC

    2 contacts

    in serie

    Contact Life

    1

    10

    100

    0,10 1,00 10,00 100,00

    No of ops (x10

    6

    )

    %ofmaxswitchingcap.

    DC resistive

    DC inductive

    NIEAF-SMITT 617650000.TSP-02 18-02-2005

  • 7/27/2019 tde-u200

    3/3

    Aust ral ian Dist ri bu to r

    Relay Monitoring Systems Pty Ltd6 Anzed CourtMulgrave, Victoria, 3170, Australia

    Phone: +61 3 8544 1200Fax: +61 3 8544 1201Email: [email protected]: www.rmspl.com.au

    mailto:[email protected]://www.rmspl.com.au/http://www.rmspl.com.au/mailto:[email protected]