79
TEC TEC TEC TEC TEC Electronic Computing Scale SL-5900 (US. Version) Document No. EM1-31015 TOKYO ELECTRIC CO., LTD.

TEC Electronic Computing Scale SL-5900 (US. Version)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TEC Electronic Computing Scale SL-5900 (US. Version)

TECTECTECTEC

TEC Electronic Computing Scale

SL-5900 (US. Version)

Document No. EM1-31015

TOKYO ELECTRIC CO., LTD.

Page 2: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

TABLE OF CONTENTS

Page l INTRODUCTION ................................................... 1

1. SPECIFICATIONS .................................................. 5

2. OVERVIEW ....................................................... 7

3. REMOTE DISPLAY ................................................. 7

4. KEYLAYOUT ..................................................... 8

5. KEY FUNCTIONS .................................................. 10

6. LAMPFUNCTIONS ................................................. 13

7. CONTROLLOCK ................................................... 14

8. LEVEL ADJUSTMENT ............................................... 15

9. CLEANING THE PRINT HEAD ......................................... 15

10. REMOVAL AND REPLACEMENT OF LABEL ROLL .......................... 16

11. REPORTPAPERTHREADING ......................................... 17

12. BEFORESTARTINGOPERATION ...................................... 17

13. OPERATING PROCEDURES .......................................... 18

13.1 Weighed Commodity Registration ................................... 18

13.2 Fix Price Registration ............................................ 21

13.3 By Count Registration (standard function) .............................. 22

13.4 By Count Registration (optional function by initial setting) ................... 24

13.5 Tare Function Procedures ......................................... 27

13.6 SAVE Key Operation Sample ....................................... 28

13.7 VOID Key Operation Sample ....................................... 29

13.8 Date Change .................................................. 29

13.9 Calling And Printing A Grade Line ................................... 30

13.10 Entry ByClerk ................................................ 31

13.11 Add Entry By Clerk ............................................. 32

13.12 Multiple Weight ............................................... 33

Page 3: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

Page 14. TOTAL OPERATION PROCEDURES ..................................... 34

14.1 HourlyTotalRepot-t ............................................. 34

14.2 Grand Total Report .............................................. 35

14.3 PLUTotalReport ............................................... 36

14.4 Clerk Total Report .............................................. 40

15. LISTUPOFPLUDATA .............................................. 42

16. PROGRAMMING PROCEDURES ....................................... 45

l Selection of Programming Menu ...................................... 45

Menu No. 0 : Changing Unit Price or Price ............................... 46

Menu No. 1 : Setting or Changing PLU Data .............................. 47

Menu No. 2 : Setting Store Address or Commercial Message .................. 52

Menu No. 3 : Adjusting Print Position for Label ............................ 53

Menu No. 4 : Setting Date, Time, Machine Number, and Store Number ........... 54

Menu No. 5 : CMT Operations ........................................ 55

Menu No. 7 : Changing Bar Code Format ................................ 57

Menu No. 8 : Assigning Speed Keys .................................... 60

Menu No. 11 : Setting Ingredient (for SL-5900-36 only) ....................... 61

Menu No. 12 : Issuing Confirmation Label (for SL-5900-35/36 only) ............... 63

Menu No. 13 : Switching On-Line/Local (for SL-5900-35136 only) ................ 64

Menu No. 17 : Setting Grade Line (for SL-5900-36 only) ...................... 65

Menu No. 18 : Memory Card (for SL-5900-36 only) .......................... 66

Menu No. 20 : Transmitting PLU File or Unit Price (FUN System) ................ 69

Menu No. 21 : Setting Clerk Name (for SL-5900-36 only) ...................... 70

Menu No. 40 : Setting Print Item #l ON/OFF ............................... 72

Menu No. 41 : Setting Print Item #2 ON/OFF ............................... 73

17. ERROR MESSAGE TABLE ........................................... 74

18. BEFORE YOU CALL FOR SERVICE ..................................... 75

CAUTION: 1. This manual may not be copied in whole or in part without prior written permission. 2. The contents of this manual may be changed without prior notice.

3. Please refer to your local Authorized Service representative with regard to any queries you may have in this manual.

Copyright 0 1996 by TEC CORPORATION All Rights Reserved l-14-10 Uchikanda. Chlvoda-ku. Tokvo. JAPAN

Page 4: TEC Electronic Computing Scale SL-5900 (US. Version)

EMI-31015D

. INTRODUCTION We thank you very much for purchasing the TEC Electronic Computing Scale SL-5900 Series. This scale has been designed with TEC reliability and offers a cost efficient system for a modest investment. The SL-5900 (with thermal printer) takes advantage of the latest technology in microprocessors and because of this, the decreased cabinet size permits the system to be placed virtually anywhere in your store. Your deli, and specialty departments can enjoy these high quality reliable TEC products. Improve your operating effectiveness and watch the enhanced utilization of your front end scanning investment. This electronic Load Cell scale eliminates all moving parts and furnishes an accurate digital display of all information. We believe that your needs will now be fully satisfied, and you will have total reliability in price calculation. Should you have any questions concerning the scale, please refer to this manual. Be sure to keep this manual for future reference.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. (for USA only)

I Changes or modifications not expressly approved by manufacturer for compliance could void the user’s authority to operate the equipment. I

“This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.”

“Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.”

(for CANADA only)

Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment. Do not attempt to effect repairs to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, unplug the machine, then contact your authorised TEC representative for assistance.

-l-

Page 5: TEC Electronic Computing Scale SL-5900 (US. Version)

Safety Precautions

This Owner’s Manual and the products (machines) which you have purchased contain indications which should be observed in order to use the machines safely and prevent harm to yourself and others and damage to property. The meanings of these indications and symbols are given below. Read these indications and become familiar with their contents before reading this Owner’s Manual.

The following safety precaution will help to ensure proper use of the scale. . Unplug the printer whenever you are working inside the scale. . Keep your work environment static free.

Meanings of Each Symbol

A I

This symbol indicates warning items (including cautions). Specific warning contents are drawn inside the Asymbol.

l (The symbol on the left indicates a general caution.)

c!D

This symbol indicates prohibited actions (prohibited items). Specific prohibited contents are drawn inside or near the 8 symbol. (The symbol on the left indicates “no disassembling”.)

,e

This symbol indicates actions which must be performed. Specific instructions are drawn inside or near theOsymbol. (The symbol on the left indicates “disconnect the power cord plug from the outlet”.)

WA!VJlNG ;:~I:: .l I me

This indicates that there is the risk of death or serious injury if the machines are-i-~p~~perly handled contrary to this indication.

. _~~-;-. -~A”uda-=~‘= I

voltage (AC) specified on the rating cause electric shock. plate, as this may cause fire or

electric shock.

appliances operate. Be sure lo provide an exclusive outlet for the machine as this may cause the machines to malfunction.

top of the machines. If metal objects or spilled liquid enter the machines, this may cause fire or electric

Page 6: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

an abnormal condition such as when the machines are producing smoke c strange smells may cause fire or

cause fire or electrical shock. electric shock. In these cases, immediately turn off the power switches and disconnect the power cord plugs from the outlet. Then, contact your sales agent (or mainte-

n If foreign objects (metal fragments,

turn off the power switches and

agent). Continued use of the machine in that condition may cause fire or electric shock.

n If the machines are dropped or thei cabinets damaged, first turn off the power switches and disconnect the power cord plugs from the outlet, ant

,, the contact your sales agent (or maintenance and service agent). Continued use of the machine in that condition may cause flre or electric

m Ensure that the equipment is properly grounded. Extension cables should also be grounded. Fire or electric shock can occur on improp- erly grounded equipment.

age to objects if the

W Do not install the machines where they might be exposed to direct sunlight, high humidity, or dust. Otherwfse fire or electric shock

[Precautions Durlng installation]

n Do not place the machines on unstable or slanted surfaces, as they may drop or fall and cause injury.

n Do not place heavy the machines, as thes become unbalanced a

-3-

Page 7: TEC Electronic Computing Scale SL-5900 (US. Version)

[Precautions When Moving the

n When moving the machines, be sure to first unplug the power cords. Moving the machines with the power cords plugged in may damage the cords and cause fire or electric

Disconnect the plug.

.,__ n When unpluggmg the power cords, be sure to hold and pull on the plug portion. Pulling on the cord portion may cut or expose the internal wires and cause fire or electric shock.

w Do not lean against the machine. It may fall and be damaged.

n When opening the cash drawer, be careful not to let the drawer hit

n Be sure to move large scale machines with two or more people. In addition, machines should be mobed after first confirming that connecting wires between machines and externally connected wires, etc. have been removed. Failure to observe these precautions may result in injury.

Precaution

The following precautions will help to ensure that this machine will continue to function correctly.

@ Try to avoid locations that have the following adverse conditions: l Temperatures below 0°C and above 40°C l Direct sunlight * Shared power socket * Excessive vibration

0 Do not subject the weighing platter to sudden shocks. @ Do not press the keys too hard. Keys will operate correctly if they are touched lightly. @ Clean the cover and weighing platter by wiping with a dry cloth or a cloth soaked with detergent

and wrung out thoroughly. Never use thinner or other volatile solvent for cleaning. 0 To ensure that the scale is operating correctly, place a known weight on the platter and check it

for correct weight measurement. This should be done every morning before starting normal operations.

@ @

At the end of the day, turn the power OFF, then clean and inspect the exterior of the scale. Try to avoid using this equipment on the same power supply as high voltage equipment or equipment likely to cause mains interference (freezer cabinets etc.).

@ USE ONLY TEC SPECIFIED media. @I DO NOT STORE the media where they might be exposed to direct sunlight, high temperatures,

high humidity, dust, or gas. @ When moving the scale, take hold of the case and lift the scale. Never hold the remote unit.

-4-

Page 8: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1. SPECIFICATIONS

Item

Maximum Capacity Minimum Scale Division Display Range Tare Unit Price Presettable Minimum Price Display Remote Diasplay :

Weight Unit Price Total Price

Message Display (option) Display Designations Remote Display Mode Capacity of PLU Memory Print Head Label Issue Method Available Printing Width Label Report Paper Power Requirement Current Consumption Temperature Limits Relative Humidity Dimensions (approx.) Weight (approx.) Memory Card

Interface : CMT Loader l/F FUN System I/F PC Keyboard I/F TMCC I/F Memory Card I/F

n Option Kit and Device

30 Ibs. 0.01 lb. O-30.05 Ibs. Up to 30 lbs. $0.01-99.99 $0.01

4 digits 4 digits 5 digits 16 characters (5x7 dot matrix) NET, PREPACK, INLINE, ERROR, ACCM, ITEMS Dual sides 400 PLUS (standard), 1240 PLUS max. (option) Thermal Print Head On-demand 1.65” RICOH 120LA or equivalent RICOH 115F (black) or equivalent AC 120V + lo%, 60Hz 120VlA, 60Hz O”C- +4O”C (32”F-104°F) 35% w 85% RH (No condensation) 15.7” (W) x 16.2”(D) x 18.7”(H) 29 Ibs. MC-1 28KB

Standard Standard Standard Standard

Standard Standard Standard Standard Standard

Cassette Magnetice Tape Loader : AIWA DR-1 PC Keyboard (for programming) : IBM PC-XT Keyboard, FUJITSU FKB-2831-001, FUJITSU FKB-

2831-101 For use of other keyboards, please conteact your TEC representative.

Programming Keyboard : TEC RK-3 Programming Keyboard Adapter : TEC OP-57-RK-3 Message Display Kit : OP-LCDFIU-US (Except SL-5900-35-C4-US) TMCC Cable Kit : OP-5900-TMCC

Page 9: TEC Electronic Computing Scale SL-5900 (US. Version)

Ehll-31015D

W FUN System The SL-5900 is based on the FUN (File Update Network) system, which is a simplified networking system unique to TEC. This system can accommodate up to 16 terminals as a multi-drop, and allows any terminal in the system to transfer its PLU fife or UNIT PRICE data to other terminals for verification.

n System Configuration

...-I-....’ Max. 16 units/system ‘..

471 CMT Loader L I

PLU File

PLU File

Control Procedure : FUN (File Update Network) ... Multi-drop Transmission Speed : 4800 BPS Number of unit/system : Max. 16 units

-6-

Page 10: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

2. OVERVIEW

,-PC keyboard connector

Platter

I L -

Message display ~~~ ( Oplion: SL-5900-30/35-C2-US \ Standard : SL-5900-35/36-C4-US / I!

Mode switch (1) Level gaugi

Control IO&~ L-Operation keyboard

3. REMOTE DISPLAY CAPACITY 30 x 0.01 Ibs

NET PREPA= lb

INLINE ERROR

TEC

Page 11: TEC Electronic Computing Scale SL-5900 (US. Version)

Ehll-31015D

4. KEY LAYOUT W Operation Keyboard

.:.:,:::.:. .I .\ . ::: :: . . ~ . . . : . . . . . . . .

32 I ..: :. .: : ;.:.:..:i.

s I . . .

..:.:. . . . . :...; 41 42 43 44 45 46 47 48 49 50 ,.,.,.

..:,::.,: : i. .: >: : .;;,.;,:: “““’ ,:,::.::; 51 52 53 54 55 56 57 56 59 60 ,,y:: j::

1 ~ I 1 1 I

, . . . . , . . . .

.“.‘.‘.> . . . : .

‘ . ‘ .~~.: i i : . : . : . : . : . : . ; : . : . : . , . , . , . , . i , . , . , . , f i ; : : : : - : f :‘.‘:‘:‘.‘:‘:‘:-:.: : : : : .‘;;:‘;: : : : . . . . . . . . . . ~ . . . ~ .~ . . . . . . . . . . . . . . . . . : : : : : : : : : : ::~ .iL:,;,. ~,,:,.,~,:,~,.,‘,‘,‘~‘,‘,‘:‘:‘~~,~~~~~. : . :z l... L.. : : : : : : : : : : : : : , : i : : : : : : : : : : : : , : : . : , : . . . . . , . , . , . , . . . . .~ . .~ . . . . . . . . . . . . ._ . . . . . . . l . . ._ . ..i. . . . . . n . . . . . . . . . . . . . . . ._ . , . i_ . , . i , . / , . . . , . j . , . . . . . . . , , , _ , , . , , : : : : : : : : : : : : : : : : : . . :

. . i:i-- . . : . : . : . : . . . i... :.:.,“:.:.::::::: i :::: j~:::~::~~:~~~ . . . . . . . . : . : j : : ; : : : : : : : : : j : ,_ j : : j . : . : : : : : : : : : : : :~ : : : : : : : : : : : : : ’ : ’ : :.:~,~~iS.~.:~;:-l:~~:~~::~~~.:.:~.~~~:~:~:~~:~~~.~:~::~:~~~~~~.~.:~:~~:~~~~~:~:: FE E D TEST ZERO : :: ..:. i...... ..,. :.:.:.: ._.,_,.,L.i__,. .,.,.,l,.,.,.,.C,.,. .,.,.,.,i.,._.,.,.,.,,,...,.,...,.,...,.,...,.,...,.,...,.,.,.,.,.,.,...,.,.,,,.,.,.,...,.,.,., L”‘< . . . . . __i,.,_.,__,.,i_______...,.,.,.,.....,.,.,.,.,.,.,.,.,.,.,., .,..:,.,:: . . ..v. n .i .,. .,.,.,.,.,...,.,.,.,...,.,.,.,.,.,....., ,.,.,...,., :.:.:.:.:.:.:+:.: . . . . . . . . : :. . . . ..,. ““‘.‘.‘.‘..‘.:.“-:.:j:.:‘:‘:~!~~~,.~:~~:~~~:~:~~~.~~ . . . . . . . . . . . . . . . ../.._i :.:.:.:.:::::::::::::.:: . . . . . . ..(. . . . . . . . . . . .

FL; VOID x

0 FOR "xM ,;,

7 8 9

4 5 6 SAVE

1 2 3 l/2

0 Tcr,, C 114

PLU ‘2

NOTE : The characters (l-60) indicated on the speed keys are shown for the convenience of explanation in this manual. The indications on the actual unit are not as shown in this illustration.

W Programming Keyboard

COMMODITY NAME

r NEXT PLU

ALIT0 CODE SEND

J

Page 12: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

H PC Keyboard (for programming)

n RK-3 (with OP-57-RK-KS) Keyboard (for programming) .- : ^

Page 13: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

5. KEY FUNCTIONS n For Operation Keyboard

Lode Switch (1) “AUTO” position: This position is used to issue regular scale labels. When the weight becomes stable, the label will automatically be issued. “MANUAL” position:

ight becomes stable, the label will be issued by depressing

vlode Switch (2)

WEIGH

“WEIGH” position: This position is used in the weighing function of the SL-5900.

BY COUNT

The unit price is entered directly to the total price on calling up PLU, and that total price cannot be changed by any subsequent weighing. “BY COUNT” position: It is available to produce labels which contain information on quantity pricing, instead of weight.

temporary date changes.

This key is used to feed labels or report paper.

In the “X” or “2” control lock position, this key is used to generate the

step to the next step.

-10 -

Page 14: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

of label issue.

commodity from the platter.

commodities.

This key is used to subtract tare weight.

This key is used to adjust the “ZERO” point.

LABEL& REPORT PAPER

q key L/R CLERK keys

This key is used to select label printout or report paper printout.

These keys are used for entry operation by clerk and add entry operation by clerk.

- 11 -

Page 15: TEC Electronic Computing Scale SL-5900 (US. Version)

Et&-31015D

n For Programming Keyboards

8 6 Key Function 9 y ?

ti g s

q This key allows the clearing of numeric entries prior to the depression

CLEAR of another function key. It is also used to release the scale from the 0 0 0 error mode.

This key is used to select the upper or lower character indicated on o x the keytop when setting the commodity name or store address.

o

while this key is pressed down, press a character key to set the small

q 0 letter of alphabet, or upper-case character indicated on the upper area of the keytop. When this key is released, the shifted status is

x 0 x

cancelled.

This key is used to recall the next PLU # (+ 1) of the PLU # currently o o x recalled.

This key is used to change the PLU # currently recalled.

This key is used to print out the data set in the currently recalled 0 0 0

q This key is used to access each programming menu. PROG 0 0 0

v

cl

0 This key is used toselect selectable items.

0 0 0

q ENTER During programming, data is input to the SL-5900 system using this key.

0 0 0

This key is used to set the free zone of the auto code for UPC #, back the digit when setting the bar code format, and return the setting line to the first line while setting the second line and during the setting

0 0 0

of the commodily name or store address.

- 12 *

Page 16: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

Function

This key is used to move the setting line when setting the commodity

key is pressed down, press a character key to set the small letter of alphabet. When this key is released, the shifted status is cancelled.

NOTE : When the power is turned off or control lock is switched, the PC keyboard or RK-3 keyboard will be initialized to select capital letters.

6. LAMP FUNCTIONS

Lamp Function

NET \ ‘/ ,yi Lights when tare is subtracted.

PREPACK \ ‘/ Iyi Lights when the SAVE key is pressed.

\ ‘/ INLINE yi Lights when the PLU or unit price file is updated.

Lights when the scale (for SL-5900-3536) is in the IN-LINE mode.

ERROR

ACCM

\‘/ Iri Lights when the scale is improperly operated or there is a function error.

\ ‘/ /yi This lamp lights when items are being added to the specific CLERK

memory in the add entry by clerk mode (for SL-5900-36).

ITEMS \ ‘f ;yi This lamp lights when items are being added to any CLERK memory in

the sub-total operation in the add entry by clerk mode (for SL-5900-36).

- 13-

Page 17: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-310150

7. CONTROL LOCK The control lock has seven marked positions.

There are two control keys which will operate these locks.

l Manager Key TSE ----I This key (MA) will access the PROGCMT, REG, OFF, M. DOWN, and REWRAP positions.

l SE Key This key (SE) will access all seven positions.

Each of the following positions on the control lock serves a different function.

Position

PROG. CMT.

REG.

OFF

M. DOWN

REWRAP

X (Read)

Z (Reset)

Function

This position is used to set the data of the PLU, store address, printing position, date, time, bar code format, etc. It is also used to transfer the PLU file using a CMT loader.

This position is the normal control lock position which allow the issuance of printed labels.

This position is used to lock the scale power.

This position is used to designate an item for discount pricing.

This position is used to designate an item for rewrapping products.

This position is used to read all the accumulated sales totals stored in the total memory.

This position is used to reset all item file totals.

- 14 -

Page 18: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

8. LEVEL ADJUSTMENT Set the scale on a stable and level surface. Level the scale by turning the adjustable legs so that the air bubble is inside the center circle.

@eve1 Gauge@

Correct Incorrect

When the air bubble moves toward the left side, When the air bubble moves toward rear, turn the turn the right adjustable legs clockwise. front adjustable legs clockwise.

9. CLEANING THE PRINT HEAD If the print head is dirty, clear printing will not be produced. It is recommended to clean the head with thermal head cleaner everyday before starting operation using the following procedure:

1. Remove the printer cover and label cassette. Then push the head-up lever in the direction indicated by the allow.

the figure to the right with the thermal head cleaner. Then set the label cassette, and push down the print head.

NOTE: Be careful not to damage the print head when cleaning.

hermal Head Cleaner

- 15 -

Page 19: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

IO. REMOVAL AND REPLACEMENT OF LABEL ROLL

I. Remove the printer cover and right side cover. Then push the head-up lever in the direction indicated by the allow.

!. Pull out the label cassette. Then remove the Label cassette core of the label roll and the label backing paper. I NOTE: To remove the label backing paper,

loosen the paper by turning the paper winding shaft counterclockwise and remove the paper stopper.

.~ ~~~~ 3. Referring to the figure on the right, set the label Roll stopper

roll on the label cassette.

Backing paper stopper

5. Push down the print head, and close the covers. NOTE: When the label roll is replaced, press the

feed key to confirm that the label is issued correctly.

- 16 -

Page 20: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

. REPORT PAPER THREADING

Roll stopper

I

Report paper

12. BEFORE STARTING OPERATION (1) (2)

(3)

(4)

(5)

(6)

(7)

Be sure to plug the power plug into an AC outlet.

When the control lock is turned from OFF to REG position, the scale goes through the test scanning sequence, such as 0000, 0000, 00000, then 1111, 1111, 11111 ... ... and zeros appear on the weight and total price displays. When the control lock is turned from OFF to PEG over 16 seconds after the power plug is plugged into an AC outlet, all “8”s appear on all displays for a moment, then zeros appear on the displays and the scale is ready for use.

While the scale is in the test sequence, do not put anything on the platter.

Do not move the scale while it is in operation. Should it become necessary to move it at any time, turn the power OFF and be sure to readjust the level indicator after relocating the scale.

Should a power failure occur during operation, remove the commodity from the platter and plug the power plug into an AC outlet again when power is restored.

If the scale is used with an unrated power source, inaccurate scaling or other errors may occur.

If the Zero Point has shifted during scaling, and no tare is displayed, adjust the Zero Point by depressing the ZERO key.

- 17-

Page 21: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13. OPERATING PROCEDURES 13.1 WEIGHED COMMODITY REGISTRATION

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH

[Example A] In the event that an unit price of $3.00 is set for PLU#lOO.

zmy- :.::.:.:,:.:.:.. . . ._....._i . . : .A.. . ..i .

;;@jti: YJgj”’ :.:., :.,.::.:., :::~:;.i’L:i::: : : :.y.: !...A. ., ;

1

2

3

4

5

Enter the PLU# .

Depress the PLU key.

Place a commodity on the platter. (ex. 2 Ibs.)

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

Remove the commodity from the platter. PLU data is returned to the PLU file.

2 00 3.00 $6.00 METW: G!F! PRICE/IS@ w ~ * - 5’ 19250 VAN NESS AVE.

~ TEL 213(320)8900 I

0.00 P J-----l 000000

__-_-- - -

NOTE : Recalling a PLU# that has not been set in the PLU file will result in an error. In this case, depress the CLEAR key, then enter a correct PLU#.

- t8-

Page 22: TEC Electronic Computing Scale SL-5900 (US. Version)

EMI-31015D

[Example B] In the event that PLU#lOO and an unit price of $3.00 are set in the speed key #I.

: : . - : - : : y : : : : . . : ;g&

: :&h’,,-.

“.>:<.‘.:‘, ‘. : : , : j : : ; : ; : : : : - . , , \ . , ./.i_.. . .

1

2

3

4

Depress the speed key #l .

Place a commodity on the platter. (ex. 2 lbs.)

SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

Remove the commodity from the platter. PLU data is returned to the speed key and PLU file.

T-BONE STEAK PACKED ON

!Ll C

DE: 6'

2.00 3.00 $6.00 NET\h’T. iG8 Anabel &f&q

19250 VAN NESS AVE. TEL 213(320)8900

NOTE : Depressing a speed key to which no PLU data has been assigned will result in an error. In this case, depress the CLEAR key, then depress a speed key to which PLU data has been assigned.

[Example C] In the event that an open unit price is set for PLU#103.

Enter the PLU# . 1 1 10 13 1 1 000103 1 0.00 1 P 1

Depress the PLU key. 0.00 0.00 0.00

Enter the unit price. (ex. $1.25) 0.00 1.25 0.00

Place a commodity on the platter. (ex. 2 Ibs.)

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

2.50.1 2.00 1 1.25 /

GROUND BEEF PACKED ON

!I! iF c

OEC 5

2.00 1.25 $2.50 NFrwr. = PRICE/lbB Cm

19250 VAN NESS AVE. TEL 213(320)8900

Page 23: TEC Electronic Computing Scale SL-5900 (US. Version)

EMI-31015D

[Example D] In the event that an unit price is $1.50 _ _ _ _ _ . Random Item PLU (optional function by initial setting)

- :.: .,.,,: .,., . . . . :g:;:j::;.::i :. : yJ&F,, .., . . ., ,., .‘:INo,- i: :.:.:,:.: : .,.. ,.......:,

1

2

3

4

NOTES

Depress the PLU key.

Enter the unit price. (ex. $1.50)

Place a commodity on the platter. (ex. 3 Ibs.)

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

0.00 0.00 0.00

0.00 1.50 0.00

3.00 1.50 4.50

3 00 1.50 $4.50 PRKUbB &ma NET ‘(IT: Kf3 a.*- s

19250 VAN NESS AVE. TEL 213(320)8900

1. This operation is available only when the Random Item PLU is set to “Available” in initial setting.

2. Although the Random Item PLU is handled as PLUTO in the REG mode, it is handled as PLU# 999999 in the PLU file.

- 20 -

Page 24: TEC Electronic Computing Scale SL-5900 (US. Version)

Ehi1-31015D

13.2 FIX PRICE REGISTRATION

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : FIX

[Example A] In the event that an unit price of $1.25 is set for PLU#33.

- . . . . . . . . . ~:‘;:y,::‘: ‘, : :gi& : Jj$ i:’ :.:.:./j:.\:. .::.:.::.:.:. . . .

1

2

3

4

Enter the PLU#.

Depress the PLU key.

Place a commodity on the platter. (ex. 1 lb.) I

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

[Example B] In the event that an open unit price is set for PLU#32.

yyEy7-Y , . . . . . . . . . . . . . . . . . . . : . , . , . ?$g,~

:‘ti;,

i . : : . : . : . : . + :&:~, : . :> : .:.i : . . . : . : , . ;

1

2

3

4

5

Enter the PLU#. k-L4

Depress the PLU key.

Enter the price. (ex. $2.00)

Place a commodity on the platter. (ex. 1 lb.)

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

0.00 P I I

000032

0.00 0.00

0.00 2.00

1 .oo 2.00 I 1

CHOCOLATE MERINGUE PIE

PACKEDON

!!iF JY

OEC 5

19250 VAN NESS AVE. TEL 213(320)8900 II

- 21-

Page 25: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.3 BY COUNT REGISTRATION (standard function)

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : BY COUNT

[Example A] In the event that PLU#302 and a price of $3.00 per 6 pieces are set in the speed key

: . : . . : . ) . . . . , . , L . . . , . .

: , $&P

::$$ : : : . : . : , . . . 1:.

. , . . , . , . a

1

2

3

NOTE When Mode SW (1) is in the “AUTO” position, the desired number of identical labels can be obtained by just depressing the PRINT key to issue the first label, then a next label will be issued once after peeling it-until depressing the CLEAR key.

#21.

Enter the speed key #21. ---.--I P 61 3.001

Depress the PRINT key.

Mode SW (1) : AUTO Labels are issued in succession after they are peeled.

Mode SW (1) : MANUAL Single label is issued.

I I I

19250 VAN NESS AVE. TEL 213(320)8900 II

[Example B] In the event that a price of $2.50 per 12 pieces is set for PLU#303.

Enter the PLUH.

Depress the PLU key. ---.--

Depress the PRINT key.

Mode SW (1) : AUTO Labels are issued in succession after they are peeled.

Mode SW (1) : MANUAL Single label is issued.

19250 VAN NESS AVE. TEL 213(320)8900

- 22 -

Page 26: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

[Example C] In case of purchasing 10 pieces of commodity at a price of $1 .OO per 6 pieces *----* SPLIT PRICE

(In the event that a price of $1 .OO per 6 pieces is set for PLU#39.)

Enter the PLU #.

2 Depress the PLU key.

3 Enter the quantity of purchase. (ex. 10 pieces) ... max. 2 digits

4 Depress the PRINT key.

5 Mode SW (1) : AUTO Labels are issued in succession after they are peeled.

Mode SW (1) : MANUAL Single label is issued.

---.-- P

---.-- P 6

---.-- 10

---.-- P 10

1 DONUTS

., : :.:::j:j :,ii:::i:::::r::i:i, .A:.,:: :) ;::$nj$&, : I .N: -..P..Rf.G~.i,. .-$;: . L... . . . .:...\... . . . ..i. . . . . . . . . . . ._...... .:::::::::j.:.:.: ;:.:.>:‘-: . . .;j,:..j,

000039

1.00

1.00

1.68

PACKED ON

DEC 4

10 tws $1,68 PRiCE/?b@ m WiVT. = * ..I s

19250 VAN NESS AVE. TEL 213(320)8900

1 1

Page 27: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.4. BY COUNT REGISTRATION (optional function by initial setting)

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : BY COUNT

[Example A] In the event that an unit price of $1.75 is set for PLU#31.

Enter the PLU #. 13111 ---.-- P 000031

Depress the PLU key. ---.-- 1.75 0.00

Enter the quantity of purchase. ---.-- 2 1.75 (ex. 2 pieces)

Depress the FOR key. ---.-- P 2 1.75

Depress the PRINT key.

Mode SW (1) : AUTO Labels are issued in succession after they are peeled.

Mode SW (1) : MANUAL Single label is issued

11 BLUEBERRY PIE 11 PACKED ON

!;F 1

DEC “5

$1.75 F’RiCE~b~ Lrsn 8 1 8’ -” s

19250 V&N NESS AVE. TEi 213[320)8900

- 24 -

Page 28: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

[Example B J In case of purchasing 6 pieces of commodity at a price of $2.75 per 3 pieces ... ... SPLIT PRICE

(In the event that PLU#826 and a price of $2.75 are set in the speed key #40.)

Depress the speed key #40.

Enter the quantity of purchase. (ex. 6 pieces)

Depress the FOR key.

Enter the quantity for that price.

Depress the FOR key.

Depress the PRINT key.

Mode SW (1) : AUTO Labels are issued in succession after they are peeled.

Mode SW (1) : MANUAL Single label is issued.

2.75

6 2.7

P 6 2.7

3 2.7

P 3 2.7:

P 6 5.54

LARGE SHR IMPS PACKED ON

ilk! E/Y

DEC 5

$5.50 PRICE/lb@ w , . .I- E

19250 VAN NESS AVE. TEL 21X320)8900

- 25 -

Page 29: TEC Electronic Computing Scale SL-5900 (US. Version)

Ml-31015D

13.5 TARE FUNCTION PROCEDURES

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH or FIX

There are two kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare”.

1) Direct tare subtraction

j::xj::,:::::, :’ : _i L.. . . . i.........

3i%i;,

I:.:&$ .’ : : ::,::::. :. .A.. .A.... /..

1

2

3

4

NOTE

Place the tare on the platter.

(ex. 0.20 Ibs.)

3epress the TARE key.

rNeighing operation. ex.) Enter the PLU#. p-jqq

Depress the PLU key. Place a commodity on. Depress the PRINT key.

qemove the commodity together with he tare. rare weight is cleared automatically, hen PLU data is returned to the PLU ile.

0.20 P

0.00 P I 0.00 P 0.00 1.50 1.00 1.50

-_-

‘:~~~~~

;,,pfg.$

,.. . . . . . ..i. . ../I .A... .A.,

..). .: . . .A> . . . . .

00000

00000~

00010 0.01 1.51

BEEF LIVER PACKEDON

DEC 1 SELL BY

DEC 4

1 .oo 1.50 $1.50 e KETW. = ,..- 4

19250 VAN NESS AVE. TEL 213(320)8900

0.00 P I 00000~

J

--II 3 I 1

-;;I

;;i;:

p :. c : :.

K..

Tare weight subtraction is available up to 30 Ibs. When tare weight ‘subtraction is in operation, however, the scalable range for net weight is decreased by the amount of the tare. (Net weight = Gross weight - tare weight)

- 26 -

Page 30: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

2) Preset tare subtraction

: : ; - : : ; * : : : : . , . . . . . , . , . , . ‘. g&

: ; ; i& j .’ . . . . . . . . . . . .

. : . : . : : . . . : . : . . a

1

2

3

4

5

Enter the tare weight. (ex. 0.20 Ibs.)

Depress the TARE key.

Place the tare on the platter.

Weighing operation.

Remove the commodity together with the tare. Tare weight is cleared automatically, then PLU data is returned to the PLU file.

-- ., .-.:.::: . . . . ,. ., ..i -.. ..-.-. .., ,.. ,.. . . . .

P

P

P

P

3) Preset tare subtraction when tare weight is included in PLU data (optional function by initial setting)

[Example] In the event that tare weight of 0.20 pounds is set for PL J#825.

s j ;::g;;:i’i:,: ii&#p g?$+*

. . . . . . . . . :.::::::::: :.:y: : ,,::~:~:$.:.::.: : __(

1

2

3

r , I 1

Enter the PLU #. 18[2151

Depress the PLU key.

If you want to change the tare weight temporarily ;

Depress the TARE Key. Enter the new tare weight. Depress the TARE key.

Place the tare on the platter.

Weighing operation.

Remove the commodity together with the tare. PLU data is returned to the PLU file.

*--r+*r- .:i:~.~3:L::::~iiSi:~;:: .‘gzc+&~~‘ii’i

i. .-. . ..i i., \. ,.i

g.&$.$.:: ., .,.,., .,.,. ,. ,.,.,.. ..:.:.::.:,:.::::::::: y,:,:,:.:

P

1.25

1.25

1.25

P

T : : : , : : : : : : : : : . : . : : : . : r . : . : . . .C’. . : . : : : . : , : , : r , . : : . ,

yaTg.,i

: &g@,

: . . . . . - . . . . . . . , , . . . . . . , . . . . . . . . . . . . . . . : . : . . . : 3 : . : ‘. ‘ : : . : : . : : . i . . . : :y . .

..-L;rrbAir.L

000825

0.00

000000

- 27 -

Page 31: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.6 SAVE KEY OPERATION SAMPLE

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH, BY COUNT, or FIX

The SAVE key is used to save tare weigh, unit price, and PLU data after taking a commodity off the platter.

6

7

8

9

10

11

12

Place the tare on the platter. (ex. 0.20 Ibs.)

Depress the TARE key.

Enter the PLU#. (ex. PLU#lOl)

Depress the PLU key.

Depress the SAVE key. The tare weight and PLU data are saved.

Place a commodity on. (ex. 1 lb.)

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

Remove the commodity together with the tare.

Depress the CLEAR key. Save mode is cleared.

Enter the 0. 0 0

Depress the TARE key. The tare weight is cleared.

Depress the PLU key. The sacle is returned to the initial mode.

1.50

1.50

1.50

P

- 28 -

Page 32: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.7 VOID KEY OPERATlON SAMPLE

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH, BY COUNT, or FIX

On depressing the VOID key, the data of the last registration is subtracted from the memory.

- ..i_. .A....... ,. ,. : . ..z.::y .,

;;&i

:..Nw . . . . . . . . . . . . . :;;‘i:i;,f:,;,;i i,’

1

2

3

4

5

13.8 DATE CHANGE

Enter the PLU#lOO.

Depress the PLU key.

Place a commodity on the platter.

Mode SW (1) : AUTO The label is issued automatically.

Mode SW (1) : MANUAL The label is issued after depressing the PRINT key.

Depress the VOID key. The data is subtracted from the memory.

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH, BY COUNT, or FIX

The date can be changed temporarily.

NOTE

Depress the DATE & TIME key.

Enter the new date. ex.) Dec. 5, 1989

120589

T-CL Year (00 lo 99)

Day (01 to 31)

- Monlh (01 to 12)

Depress the PRINT key.

.:.:.: :.:.:.: :.:.:.;.:.:.:.:.:. .: .,...,... >> . . . . . . . . . . .,., ,.

.f :: Q& !.X;1. I $$.fc.,. .,.:,:.:...:.; :: i .:,< .: :

P

3.00

3.00

---.-- 3.00

i : . . . . , . . . : : . ; : : ‘ , . . : .

~~~~~~.

t.FSRlCE . . . , . . . . . ..i . , : . . . . , . _.. . . :.’ :~:.3’...-.: : ~ . : , : : , _/ ‘_.> . . . . : . . . . . . ._. . ._..

000100

0.00

3.00

---.-- 3.00

i 20589

000000

!zzz :.:.:.:.:. ,:.::::y: PI:.. E:

:y; ., ,. ., u _

-

The SL-5900 will check details of date input, and any wrong date will result in an error mode. The correct date should be re-entered after depressing the CLEAR key.

- 29 -

Page 33: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.9 CALLING AND PRINTING A GRADE LINE

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH, BY COUNT, or FIX

A required Grade Line of those programmed (maximum 49 Grade Lines) can be call and printed on the label to be issued, for the purpose of adding a short message to the commodity name.

. . . . . . . . . i.. ..i. . . , ; . : . : . . . : . : . : . : . : . : : : , : . / / > : I : : , :

f$&? I

‘:‘:j@; : :

>;:+::: :- i::zi:i:;:::i:

m

1

2

3

4

5

Enter the PLU#lO9.

Depress the PLU key.

Depress the G.Line key.

Enter the required Grade Line #3 (Max.49)

Depress the PRINT key.

NOTES : 1.

2.

3.

4.

---.--

------ P 3 1 .oo

The Grade Line # to be called in this operation must be one of those programmed beforehand. If a Grade Line # of no programmed data is entered, a “DATA ENTRY ERROR” will result on the following [PRT/*] key depression.

When a Grade Line Entry is operated after a PLU Entry as in the example above, the Grade Line content is not displayed in the Messasge Window but is printed on the label. On the contrary, when a Grade Line Entry is operated before a PLU Entry, the Grade Line content is displayed in the Message Window but is not printed.

The Grade Line print position (above or below the Commodity Name line) is determined by Initial Setting.

The maximum number of grade line characters is 26.

- 30 -

Page 34: TEC Electronic Computing Scale SL-5900 (US. Version)

EM-31015D

13.10 ENTRY BY CLERK

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH, BY COUNT, or FIX

The entry by clerk mode is used to print out clerk sales data on labels.

g& 9’,fj&J::., .::.:+..:..:. >.

1

2

3

4

Enter the PLU#33.

Depress the PLU key.

Place a commodity on the platter.

Depress the CLERK key. Depressing the CLERK key allows a receipt to be printed out.

NOTES : 1. PLUS can also be called by using the Speed key.

2.50 0.00

2.50 2.50

2.50 2.50

2. In the entry by clerk mode, a label is manually issued and its data is recorded in the CLERK TOTAL memory, regardless of the position of switch (1).

- 3t-

Page 35: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.11 ADD ENTRY BY CLERK

Control lock : REG Mode SW (2) : WEIGH, BY COUNT, or FIX

The add entry by clerk mode is used to print out receipts.

Enter the UR key.

Enter the PLU#l50.

Depress the PLU key.

Place a commodity on the platter. ex.) Depress the CLERK key.

Depress the 0 key. Enter the PLU#20. Enter the VOID key.

Enter the PRINT key. -

NOTES : 1. The Speed key can be used for calling the first PLU but cannot be used after pressing the 0 key.

2. Depressing the CLERK key causes the item total to be displayed as “SUB-TOTAL”.

3. There are three kinds of void operations:

1) Item Correct . _ . . . Depress the CLERK key, followed by the VOID key. 2) Void . . . . . . . . . . Deletes an item which was previously added. 3) All void . . . . . . . . Depress the 0 key, followed by the VOID key.

4. Up to 48 items can be added in the add entry mode.

- 32 =

Page 36: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

13.12 MULTIPLE WEIGHT

Control lock : REG, M.DOWN, or REWRAP Mode SW (2) : WEIGH

This mode can be used when the option for multiple weight has been selected, and the entry unit price can be changed or the unit price is open.

- ;$~;g,::~:;: : .’ . .I. . . . . ,...,.,.,. ,.

$g@P.

;;::.:+.. :::.:.:.:.::.:. .,,\,

1

2

3

4

5

Enter the PLU#60.

Enter the Purchased Quantity. (Numeric entry = l-9)

Depress the FOR key.

Enter the unit price. (ex. $5.5)

Place a commodity on the platter.

yz?Tzyxr . . ‘.. . . . . . . . . . .

j .:.:.:y fli,, : ..~@&~:: .:...:.>..: .(..,. :.:.:.,.:...: ,.,

1 3.00

1 0.03

3 0.00

3 5.50

3 5.50

0.00

0.00

0.00

3.68

:I.: W:

.Xl I .J. :: rJ :

.L

-

ex) The amount for buying 21b of a product which costs $5.50 per 31b is automatically calculated.

- 33 -

Page 37: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

14. TOTAL OPERATION PROCEDURES When the control lock is set to the “X” or “Z” position, it is available to issue READ or RESET reports. When the control lock is set to the “X (READ)” position, the totals will not be cleared as they are printed on labels (for except the hourly report) or report paper. When the control lock is set to the “Z (RESET)” position, the totals will be cleared as they printed on labels (for except the hourly report) or report paper.

NOTE: Before printing out totals on the report paper, change the initial setting.

14.1 HOURLY TOTAL REPORT

The hourly total report is printed on report paper only.

Enter the report #l.

HOURLY REPORT bEIN MnIKEI 16 EC/ l/89

STOREI 7 1942

IKUR CtulT wuil wwds 15-16 69 36.93 107.65

f % 17.7 16.17 65 51.75 1266.11

I % 2lJ.B 17.18 ia aha ill.60’

s 4 18.3 18-19 12 50.83 121.56

s % 20.0 19-m 93 61.88 161.67

s % 23.3

TOM 267 2h1.87 600.29

Page 38: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

14.2 GRAND TOTAL REPORT ::$;:g;:;:;:::. ; .: ,....: . . . . . . . . :~f.g

p$[::

. . ::::$i:$$:,:’ . . . . .-........... 2.. . . .

1

2

3

4

Enter the report #2.

Depress the PRINT key.

2

2-

Enter the total memory #. #1 : Day total (Normal) #2 : Mark Down total #3 : Rewrap total

21 22 23

Depress the PRINT key. nn

Day total : GRAND TOTAL PACKED ON

DEC I NO SELL BY

NETw2g34 390 680.20 . l PRKVlbB &g&e&& l . -.

19250 VAN NESS AVE. TEL 213(320)8900

, Mark Down total : GRAND TOTAL

HO

PACKED ON

DEC 1 SELL BY

7.98 30 27.42 PRICE/lb@ w NETWT. m , 4 --,

Rewrap total

I 19250 VAN NESS AVE. TEL 213(320)8900

GRAND TOTAL PACKED ON

RQ DEC 1 SELL BY

7.54 999856 27.54 NETVIT. UBi4 PFlfX/?b~ u ( > .-

19250 VAN NESS AVE. TEL 213(320)8900

P : W: $ :. 2 .: :’ k::: -

GRAND TOTAL l&m REm fwltrS 16 Kc/ l/89

smll 19:Y

CaJlil Rluil rJuRQ3 TOllI 39l 236.3 680.20

GRAND TOTAL iN%wllwJ ftxnIH1 16 DEc/ 149 mREl7 19:#I

m lmr rm.M TOTi% 30 7.98 2I.U

GRAND TOTAL

- 35 =

Page 39: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

14.3 PLU TOTAL REPORT

1) Individual total

[Example] Individual PLU total (PLU#lOO) in the day total memory.

1 Enter the report #3.

2 Depress the PRINT key.

3 Enter the total memory #l.

4 Depress the PRINT key.

5 Enter the search code 1. Code 1 : PLW Code 2: UPC#

Depress the PRINT key.

Enter the PLU#lOO.

Depress the PRINT key.

-I-Y-yY .::..::.:... ‘:~‘l.::.:,‘:’

‘~~~~i:i

,:,$@iE:g..‘:

,. .._ .,. : /\:... :.:. . ,: -‘::~:.:‘.:i::ll.:::,::~:?:~.~,

3

3-

31

31 -

311

311 q

311 q

311

PLU TOTAL PACKEDON

DEC 1 PLU# NO SELL BY PLU REPORT

000100 Ftu I ODolDl NolwlRFAD

2h 95.99 287.97 im.0 5 OF GfW IDOIUYISI 42.3

- 36 -

Page 40: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

2) Block total

[Example] UPC block total (UPC#250820-250829) in the mark down total memory.

1 Enter the report #3. 3

2 Depress the PRINT key. 3-

3 Enter the total memory #2. 32

4 Depress the PRINT key. 32 -

5 Enter the search code 2. 322

6 Depress the PRINT key. 322 q

7 Enter the UPC#25082. 322 0

8 Depress the 0 key. III 322 IJ

9 Depress the PRINT key. 322

25082

25082 -

3

NOTE : The m kev reoresents 0 throuoh 9. . . Most significant digit in starting number followed by approzte number of the 0 keys.

III

PLU TOTAL i PAWEDON ~

UPC HO DEC 1 ~ SELL BY

25082-

2.66 2 6.12 e NFfWL = ‘ , .-

19250 V&N NESS AVE. TEL 213(320)8900

PLU REPORT LREm- MaoMREfa IfICIIIH# 16 MU 1189

srma 7 Whl

Ft coull RIGHr WllM s x 2sam 2 2.66 6.12 1M.O

KM 2 2.66 6.12 1M.O 5 OF c&id [WUIIRSI 22.3

- 37 -

Page 41: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

3) Zone total

[Example] PLU zone total (PLU#lOO-303) in the rewrap total memory.

7 :p$.; : f$f: ! . : . : .> : . . . : . , .~ ‘[$$+-.&

jJ&j;’ . , . , , . . . , . . . . v . . . . . .

_i..._i i . . . . . : . . . : . : . : : . : . . -

1 Enter the report #3.

2 Depress the PRINT key.

3 Enter the total memory #3.

4 Depress the PRINT key.

5 Enter the search code 1.

6 Depress the PRINT key.

7 Enter the start PLLMOO.

8 Depress the FOR key.

9 Enter the end PLW303.

10 Depress the PRINT key.

PLU TOTAL P A C K E D ON

DEC I PLU# RO SELL B Y

000100-000303

5.32 52 21.98 NETW. IlB PRlCE/lb~ m ( , - -

19250 VAN NESS AVE. TEL 213(320)8900

PLU REPORT ~ufrm1m-mn#13 itfw ffm

tWtIH1 16 Kc/ 149 STaif# 7 1942

TOM 52 5.32 21.98 tm.0 5 OF GRIW WIwRsl 79.8

Page 42: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

4) Entire total

[Example] Entire PLU total in the day total memory.

Enter the report #3.

Depress the PRINT key.

Enter the total memory #l.

Depress the PRINT key.

Enter the search code 1.

Depress the PRINT key twice.

PLU TOTAL PACKED ON

PLU% NO ALL

680.20 PRlCE/lb~ bm

19250 VAN NESS AVE. TEL 21X320)8900

PLU REPORT RU t flu HoRI#REAo rYICHlRt 16 DEW 149

STW 1 19:13

Rut #WIT WM WURRS S% Wl BLUEBERRY PIE

tlmJ32 UtLln 3.54 9.m 1.b

tERlKX PIE PA2 18.84 2.0

Km33 tdbhm#I I 1.33 S.bl 0.8

m39 rsmi 62 0.m 10.36 1.5

MIxi CHlcKEH UIKi 181 0.M bfJ.Ul 5.9

liiYJ83 ao5TEM 2.66 6.12 0.9

ml821 4 FltErS 2 6.63 lb.s! 2.1

au825 5wfs

Liil Siii 13.33 2.0

woBz6 11.M 1.6

tm9 &Ew)I(s 3 15.93 3s.as 5.3

999999 5 7.59 10.98 1.6

TOM 39u 2363 680.20 lM.O % of Ijwyo ttlu%sl loo.0

- 39 -

Page 43: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

14.4 CLERK TOTAL REPORT (for SL-5900-36 only)

1) Clerk total

This is valid only when intial set 1 l-l is 1.

.:,:j:: ::..::: : ,. ::;g&

,;,Nij;. .,............ ::.. .:.: :.:.:.:..: . .,. ., ,.,. :,;.:.:. >)>;

1

2

3

4

5

6

Enter the report #4.

Depress the PRINT key.

Enter the clerk memory #l .

Depress the PRINT key.

Enter the total memory #. #l: Day total (Normal)

#2: Mark Down total #3: Rewrap total

Depress the PRINT key.

4

4-

41

41 -

411

412

413

41n

NOTE: When the option for label has been selected by initial set 9-2, the data for clerks 1 to 6 is printed on labels in on-demand dispensing mode (a clerk is skipped if its data is 0), and finally the gross total is printed. For report paper, the data for clerks 1 to 6 and the gross total are printed.

I

CLERK TOTAL CLERK TOTAL PLCWON FxclmoN

CLERK ll I aEv~y2g I.KAWAHATA

CLERK I 5 OCT 29 aE!L BY

A.SUZUKI

2 3.57 *flom - "baa I... ux

4401-A BANKERS CIRCLE AT. TEL 123(233)8900

r

CLERK TOTAL PAcxEt ON CLERK il 2 NT 29

ant ay JIW USHIJIHA

2 15.12 PXE,?I k.],&&,z& YIWT. m

4401-A BANKERS CIRCLE AT. TEL 123(233)8900

CLERK t ALL

_-- -‘-= CLERK TOTAL tloRt!a REAO ttxHINE10 ocrm9o

STOW 0 13:M 0fPT.W 0

CLERK ti CLERK NM ITEh5 OOLLMS 1 I.KIWAIYITA 35 2 JJH.USHIJlii : 3.57 3

: fiSU2W I f f 2 15:12

6 0 0.w

TOTIll 6 22.26

-4o-

Page 44: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

2) Clerk name

With the SL-5900, the setting PLU data can be listed on report paper when the control lock is set to the “X” position.

. . : . : . : . : . : : : : : . - ; . j

. . . A . . . . \ . .

ycxp’

;;;g@ ; : “ , z::>y+

m

1

2

3

4

Enter the report 374. 4

Depress the PRINT key. 4-

Enter the clerk memory #2. 42

Depress the PRINT key. 42 -

w : .: ..,.......,... . . ..,. .,. .,

;: ,:giy$ ..::;

: ..;gRG;s: .._ . . . . . . .-...:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ,.::.: : . . . . . . . . . . . . . . . . .

:

. .

I

.._ . .

.g ;r- . . . .A.. ..:...:.:.: iiii

-

CLERK NAME

UEftKl URK NRIE .I I.WIMIR 2 JiH.usIlJl~

-i H.nlKITsu S.suNKI

5 R.YJ2MI 6 T.AspxA

- 4t-

Page 45: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

15. LIST UP OF PLU DATA With the SL-5900, the setting PLU data can be listed on report paper when the control lock is set to the “X” position (optional function by initial setting). Before listing, set the report paper on the label cassette and install it correctly in the scale.

4

Enter the report #51.

Depress the PRINT key.

Enter the PLU #. ex.1) List up the individual PLU

report. (PLU #lOO) Enter the PLU #lOO.

sx.2) List up the block PLU report. (PLU #820 - 829) Enter the PL #82. Depress the 0 key. PI

3x.3) List up the zone PLU report. (PLU moo -303) Enter the start PLU #loo. Depress the FOR key. Enter the end PLU #303.

ex.4) List up the entire PLU report.

Depress the PRINT key.

100

82 82-

Page 46: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

W Sample Reports

Ex.1) Individual PLU report

PLU PROGRAMED DATA PLU PROGRAMED DATA l-u I al1w Ptu I BAYJlM-w3u3

tKliIRI 16 lw 149 ma 7 1945

Ptu I #)noolTy llEscvTlOH mm T-M S&w

&t lZ!NO SfU / lb 3.ti Tlyll 0.m SXLF LIFE 5

Ex.2) Block PLU report

PLU PROGRAMED DATA RU I l.lw-

tWlIHI 16 ow 149 STcEl7 1948

Ex.3) Zone PLU report

MIIIM 16 EC/ 1m STaa 7 1949

Iv4 t comITy llEslxIPTIW aum T-~~~STW

m 1idtM Siffi / lb 3.M ME 0.M YUF LIFE 5

ilm101 BEEF LIVER w: lit+llOl s#R / lb 1.9

TARE 0.20 3El.F LIFE 3 MO102 W SlRtOlN

s12aER STEM M tal[P 8w / lb 3.50

TfE 0.M SELF LIFE i 03103 oKlIla EEF

w: 1Mlm #ii / lb tlPEi/ TARE 0.m 3a.F LIFE 1

ml1 Mu CHIcm w: 1m1 m / lb 0.75

Tfa 0.m !!JaF LIFE 6 lIlm2 WlacN LEG5

w: 1m 8w 1 lb 3.M Tfdif 0.M SELF LIFE I

cm03 MICKM Ullbi w: 11303 Sffi 1 lb 2.50

TfE 0.M SELF LIFE s

Page 47: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

Ex.4) Entire PLU report

PLU PROGRAMED DATA

DARE 0.00 ~ENIFE 4 omll wI.F CmIHs

w: lmt fiR / lb 0.75 TYIE 0.00 3ELF LIFE 6

m302 #IicKEHm ~ 120302 S’fii / lb 3.M TrylE 0-m WLIR 6

an03 UmDl UlE w: 1M303 m / lb 2.9 ME 0.m SELF LIFE 5

m CaSTEMs bt2508M ml lb 2.30

ME 0.M QELF LIFE 3 m#ul COD FltETS

m250821 m/lb 2.50 TINE 0.M 9El.F LIFE 3

LIB!25 YlfItPs m = ml/2lb 1.25

TM 0.20 3aF LIFE 3 wo826 lHESMItf’S

w:250826 #!I lb 2.75 Mf 0.00 SW LIFE 1

MO829 fiiuaDs#wDwwN(s w:250829 #fk!/ lb 2.25 TM 0.m w LIFE 7

999999 Rm m/lb @f/i rta 0-m WLIR 0

-&I-

Page 48: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

16. PROGRAMMING PROCEDURES l Selection of Programming Menu

Turn the control lock to “PROGICMT” position.

Select the menu #. (Refer to table 1.)

Depress the PROG key.

Start the programming.

Depress the PROG key. (Finish)

Return the step #2 or select another mode.

Menu No. item

0 Changing Unit Price or Price

1 Setting or Changing PLU Data

2 Setting Store Address or Commercial Message

3 Adjusting Print Position for Label 4 Setting Date, Time, Machine Number, and Store Number

5 CMT Operations

7 Changing Bar Code Format

8 Assigning Speed Keys

11 Setting Ingredient

12 Issuing Confirmation Label (for 311-5900-35136 only)

13 Switching On-Line/Local (for SL-5900-35136 only)

17 Setting Grade Line (for SL-5900-36 only)

18 Memory Card (for SL-5900-36 only) 20 Transmitting PLU File or Unit Price (FUN System)

21 Setting Clerk Name (for SL-5900-36 only)

40 Setting Print Item #l ON/OFF

41 Setting Print Item #2 ON/OFF

P

Pn

P

n

t

n

Menu #.

1

W Table 1 : Programming Menu Numbers and Their Functions

Page 49: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-310150

o Changing Unit Price or Price The unit price or price in the PLU that is previously stored can be changed with this menu.

Menu #.

PLW.

New unit price

or price.

ENTER

I

1 2 5

0 TEST

The setling

label is issued.

’ i i PROG.

(Select another menu or mode.)

w ,j.:::.:.:;+: ;,: :y:...:.: ..: ,y.J$i . . . . . . . . . . . .A.... ~~~~ . . . . . . . . ,......... .\ ._.,. __ ./,.

..:::,:...;.:. :‘::::. p&&&&

P

PO

PO

PO

PO

PO

0

31

101

1.50

1.25

101

0

NOTES: I. Recalling a PLU# that has not been stored in the FLU file will result in an error.

The smallest PLU# in the memory is displayed.

- L

2. It is not available to change the unit price of a PLU if it has been set to “open price”.

- 46 *

Page 50: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1 Menu No. 1 1

l Setting or Changing PLU Data Setting or changing the contents of PLU (PLU#, UPCX, Commodity Name, etc.).

Menu #.

AUTO CODE

for the UPW.

PLU#. I 1

UPCH.

(continued on next page)

P

Pl

Pl

Pl

Pl

Pl

Pl

Pl

‘1

1

10

10

1

1

2

2

3

NOTE: UPCX is set after overwriting with the data of AUTO CODE. ex. 1) Input 101 ex.2) Input 1234

AUTO CODE : 120--- AUTO CODE : 120--- UPC# : 120101 UPC# : 120234

The smallest PLU# in the memory is displayed.

- 47 -

Page 51: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

Commodity

2nd line setting.

Quantity.

Unit price or price.

r-l ENTER

‘T Opentprice.

w

Unit price flag

I ENTER

ENTER ~-__ ‘6’ w

2

(continued on next page)

Pl

Pl

P

'1

'1

'1

'1

21

Pl

'1

'1

'1

4

5

0

10

0

3

0.00

1.50

L-l

-

:,, .e g:’

E‘i )y

j:: j &

Page 52: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

Shelf life.

Tare weight. rh

2 0

i,_l ENTER

+ a

WEIGH mode -0

BY COUNT mode - 1 ---b

FIX PRICE mode - 2 -----b

I

PROG.

(Selecl anottler menu or mode.)

NOTES:

?l

‘1

‘1

‘1

‘I

‘1

‘1

J

0.20

0

0

1

2

101

1

1. The commodity name can be set in two lines. Each line can contain up to 26 characters including spaces. Before setting the second line, depress the RETURN key.

2. When the quantity is 1 or more (PLU in BY COUNT mode), the unit price flag is skipped automatically.

3. When the quantity is 1 or more (PLU in BY COUNT mode), the tare weight setting is skipped automatically even if the tare weight setting has been enabled.

- 49 -

Page 53: TEC Electronic Computing Scale SL-5900 (US. Version)

Ehll-31015D

n Changing PLU Number

Menu #.

Current PLU#.

New PLW.

1

PROG.

CHANGE PLU

ENTER

3 5

ENTER

tl PROG.

(Select another menu or mode.)

P

Pl

Pl

Pl

Pl

Pl

Pl

P

?x?? :..::::.::. . . . . :.:.:. g.:i E.X. jr.;., ,:::: ..:, j..&

-

- .

i-:. L :: :I”:” q:::’ E:. .bY”

NOTE: It is not available to change to a PLU# which has already been used in the PLU file.

- 50 -

Page 54: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

n Deleting PLU Data

Menu #.

PLW.

cl PROG.

(Select another menu or mode.)

P

Pl

Pl

Pl

Pl

NOTE: All the data programmed for PLU#103 in the PLU file is deleted. If the scale goes into error during a PLU deletion, it has not been reset or PLU# designated in the above procedure had not been preset in the PLU file.

-51 -

Page 55: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1 Menu No. 2 1

l Setting Store Address or Commercial Message With the SL-5900 scale, the store address or a commercial message can be set in the memory.

Menu #.

Enter the address or commercial

(Select another menu or mode.)

. . : ji.:.j:~:::::~:‘:~~:l;~: : :qg;g,;

..i ‘ . . : . : : . : . . : ‘,, ; . pB tCE :

: . : : . : . : . . . . . . . . . . . . . / / , . , : . , . . : . : . . . : .p> : . : >:.

2

1 0

2

NOTE: The store address or a commercial message can be set in two lines. Each line can contain up to 26 characters including spaces. Before setting the second line, depress the RETURN key.

- 52 -

Page 56: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Adjusting Print Position for Label When a printed data position deviates from the normal position in the forward or backward direction along the label feed direction, adjust the print position using the following procedure.

m _,_,. . . A.

Fj, ..i..

g;; ..:...:.:,.: -

-

,: : ‘li

P3 Ll 100

t

il .:I :‘! Y

1 P3 Ll

- Standard

110

Menu %.

Feed value.

(O-199)

ENTER

%

1 gradatic

P3

P3

1 dot = 0.154mm

L2 5

t

L2 6

St: far va

va

- -

t

5

Standa

Commodity name position. (0- 9)

1 gradation = 3 dots = 0.462mm

P3 L3

P3 L3

rd

Address position.

(O-9) 4

ENTER

%

1 gradation = 3 dots = 0.462mm 1

P3 Ll

P

110

3

1 (Selecl another menu or mode.) -L- -

NOTE: When the print position for a commodity name is lowered or raised, the print position for the address is also lowered or raised. After adjusting the print position for the commodity name, make sure to confirm the print position of the address.

- 53 -

Page 57: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Setting Date, Time, Machine Number, and Store Number ..K _,..., . . . . . . :... ?; t.. F:.:, ..,.7.:. iLi

c

I-

1 -

;’ .: ‘:& .‘.-.I g.:.,;. 8”: s:.:’ ‘:k :. A:: :c.,, $‘i ;: :: 1.1. ‘o 1. (+’

:,11

t,:‘;... g ..:. A:.;. &::

4

i 13089

12

1201

120189

800

15

1530

16

7

la

120189

4

Month (01 - 12)

3

‘4

‘4

‘4

‘4

‘4

‘4

‘4

‘4

‘4

3

Menu #.

Current setting date

Dale.

(cx. Dec. 1, 1989)

0 1 liEI a 9

Day (01-31)

Year (00- 99)

El ENTER Current setting time.

1 5 l!!l!J 3 0

Time. (ex. 15 : 30) Hour (00- 23)

Minule (00-59)

czl ENTER

Machine #.

Slore #.

DEPT# MAX. 5 digits

(for C4-36 only)

(Select another menu or mode.) 1- - -_ L

NOTES: 1. Express all time in a 24 hour military format. 2. The SL-5900 will check details of date (time) input, and any wrong date (time) will result in an

error mode. The correct date (time) should be re-entered after depressing the CLEAR key.

-54-

Page 58: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1 Menu No. 5 1

l CMT Operations The SL-5900 is designed to interface with a Cassette Magnetic Tape loader. The CMT loader allows the transfer of the entire PLU file from the SL-5900 to magnetic tape. This can be accomplished in a number of operation steps. In turn, information from the magnetic tape can also be transferred to another SL-59bO.

Menu #.

SAVE

(59004XlT)

VERIFY

(5900 = CMT)

LOAD

(5900tCMT)

VERIFY

5

I

PROG.

Load the tape into the CMT loader.

(5900 = CMT = SL66)

LOAD

(5900cCMTtSL66)

Rewind the

Tape.

n iI-- I 3

m (for SL-5900-35)

----Em+ (for SL-5900-35)

(Se&l another menu or mode.)

. . . . . . ..~... ./.. . . . . . . . . . . . . ,. ,.... . . . . . . . . . . . . . . ..\... . . . . .jij,.,.,.,,,.i,.,.,. ., .;.:.:.: .,.j,.j,,.,.,,,.,.,.,.,.. :“~~~~: i

:_i ~~~~~EI’ i

:::~~j’:ii:I-!p:‘:::~:.: .:

P

P5

P5

P5

P5

P5

P5

P5

P

P

5

1

2

3

12

13

n

5

L - -

7 I: ‘. r3.. / ‘:. 5.” , j.:.

!g

;;1.

1:

-

or 13)

- ! - 55 -

Page 59: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-310150

NOTES: 1. The error mode can be released by depressing the CLEAR key, and operated again through

the above steps.

2. Use the metal cassette tape which is commercially available and has a capacity of 45 or 60 minutes recording.

3. For operations of the CMT loader, refer to the instruction manual provided with the CMT loader.

n Error Code during CMT Operations

TOTAL PRICE

pRq

A

Error Code Phenomena

l-7 Hardware error

8 Verify error - 1 Character over error

2 BCC error 4 Data error

8 Time out error

- 56 -

Page 60: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Changing Bar Code Format With the SL-5900 scale, three kinds of bar code formats are available : Weighing format, By Count format, and the FIX PRICE format. These formats can be changed freely.

Menu #.

Switch over_the

setting item

Skip Ihe digit.

Set Cl.

Sol CZ-C6.

Sel Pl -P4.

Menu #.

WEIGH mode.

BY COUNT mode.

FIX PRICE mode.

RECEIPT mode. (lor C4-36 only)

I I

-l-

-2-

-3-

- 6

IENTE;;lz= 0 0 B NEXT

PLU

I I

(Select anolher menu or mode.)

P

P7

P7

P7

P7

P7

P7

P7

P7

p7

‘7

‘7

‘7

‘7

‘7

,

.c,. 3 ...,....:,..i:.:,~

::f&&$

,;g!$$g .,:: >..::-::::.:::::.:.:.:.;:.- :.,“:::::‘:‘.~:::::::::i:j: .. .--

I

.

c

E

1 1-o

3 1-o

3 l-2

3 3-2

I 3-3

I 5-1

i 5-l

I 1-o

7

:.:.:, ::.. . . . . ::,.,.

9:

ii : .:. : ..:. iu:

Pm- g- H:: x: .L

-

- 57 -

Page 61: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

NOTES: 1. In this scale, the previously set bar code format is cleared by RAM clear, and can be

switched to the following formats. Therefore, it is necessary to set the bar code format again after RAM clear.

Bar Code Format by Initialization: 0 Weighing format

C2 C3 C4 C5 C6 PC/D Pl P2 P3 P4 C/D

8 By Count Format

C2 C3 C4 C5 0 0 0 0 C6 C/D

8 Fix Price Format

C2 C3 C4 C5 C6 PC/D Pl P2 P3 P4

@ RECEIPT Format (for C4-36 only)

0 2 D2 D3 D4 D5 D6 PC/D Pl P2 P3 P4 C/D

2. When the ENTER key is depressed, format check is executed, resulting in an error in the following cases. 0 Price check digit (PC/D) cannot be calculated. 8 Price is not set serially beginning from Pl. 0 The format does not comply with the bar code format.

3. Check digit (C/D) is set automatically to the digit-13.

4. The usable keys to set the column are as follows:

5. Digits and display of PLU#.

FLAG

PLU#

UPC# PC/D

El -I i-i-l -I

P&E 1 1 ; ;

DEPT# (for C4-36 only)

PLU#

Display

2 3 4 5 6

2-l 2-2 2-3 2-4 2-5 2-6

- 58 -

Page 62: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

6. Digits and display of UPC#.

UPC#

Display

7. Digits and display of price.

Price

Display 5-1 5-2 5-3 5-4

8. Digits and display of DEPT#. (for C4-36 only)

DEPT#

Display

9. Setting items.

1

2 3 4 5 6

3-l 3-2 3-3 3-4 3-5 3-6

6-l 6-2 6-3 6-4 6-5

2 3 c Flag d PLU# -----b UPC#

DEPT# b Price - PC/D

6 5 4

- 59 -

Page 63: TEC Electronic Computing Scale SL-5900 (US. Version)

EM1 -3101 SD

1 Menu No. 8 1

a Assigning Speed Keys The SL-5900 has 60 PLU speed keys which are very convenient to call a PLU quickly.

Menu #.

Speed key #. (1 - 60)

PLW.

/ ENTER

11 PROG.

(Select another menu or mode.)

P

P8

P8

P8

P8

P8

P

10

10

-ccrw ‘,‘.:.:.:::~:i::::.:.i:::;:::: :~~~~~I:

>,.>> ,.,._. >: .,/ ..: . . . . . . -FRfc.,:;; f

‘* .i:.. ..,.... i........ . .

.::::::::::::::::il:i::3:::i: : ,. ..>:...> . . . . > . . . . . . . . . . . . . ..( . . mAd

8

10

829

8

::..:I.:::

v:‘: I .: *t . . p ; .:. : ,:... &&

NOTE: When “0” is set on the speed key, if this speed key is pressed in the REG, MARK DOWN, or REWRAP mode, the scale enters an error mode.

- 60 -

Page 64: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Setting Ingredient Ingredient message can be printed on a label in maximum 45 characters per line, up to 6 lines with small signed letter.

Menu #

Enter the PLW

Call the next PLW.

;;tl,“e previous

el ENTER

Call the Stored Ingredient Message.

Set the data on the second line and subsequent.

(Select another menu or mode.)

.?:x:::::::::z$:x:::~:+j.~: ::::::.:.:::::::r:s.:,:r.:.. ,.,.,., :;

~~~~

~~~~~~ ,‘.,.,.... . . ,,,(,,, ::::::::.:::::j:::::::::;:$ :.::::q ‘.‘. .V’. . . . . :.:.....: ._.,.,. . . . . ::::::::~:::::~:i::~:~:::.:::.+~:~, :.:.:...:il.. .-.. i..

P

PI1

Pll

Pll

Pll

Pll

Pll

Pll

Pll

Pll

PI1

P

11

1234

1235

1233

0

12

12

4

1234

- 63 -

Page 65: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

NOTES: 1. ingredient data cannot be saved into CMT, PL-3 and RAM card for the TEC SL66.

2. This setting function can be used only after designating the PLU# by initial set g-6, 7 and 8, and selecting RAM capacity by initial set 14-4 and 5 fo secure a memory space. Data may be damaged if the initial set is changed during ingredient setting.

Initial Set 9 Initial Set 14

3. When no data is programmed for the PLU, ingredient cannot be set.

4. “PLU NOT FOUND” error occurs when PLU# not registered is entered.

5. The ingredient to be used for SEND or RECEIVE is cleared when entering this mode.

6. “MEMORY FULL” error occurs when there is no memory space to register ingredient data.

7. Plural PLUS cannot use same ingredient data. (PLU and ingredient data are in pairs.)

8. Any terminal in FUN System can transfer PLU and its ingredient data in pairs to other terminals.

- 62 -

Page 66: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Issuing Confirmation Label (for SL-5900-35136 only) Test Iabels used to confirm that a PLU previously present to this scale is present in the master file of the POS system, can be issued.

Menu b.

Sel the individual PLU #.

Set the block PLU #. (Ex. 820- 829)

Set the zone PLU #. (Ex. 100-303)

Set the entire PLU #

f-q-q-q-2 ENTER

/

L

To interrupl label issue.

To resumi label issue which has been inlerrupted.

To cancel label issue which has been inlernrpted.

- ENTER

- CLEAR ---+ 2

4

1 PROG. 1

(Selccl another menu or mode.)

. . . . . . . . r +,.::j ;: L: .:: 2

- 63 -

Page 67: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1 Menu No. 13 1

l Switching On-Line/Local (for SL-5900-35/36 only) When the SL-5900-35 is used as a satellite in an on-line system, the “ID No.” and *Transmission Delay Time” must be set by the following procedure.

Menu #.

Switch the using mode of the scale.

Enter the ID #. (O- 255)

Select the transmission delay time (1 - 9). (Refer to table 2)

Local * On-Line FMCC-3)

Local

(Select anolher menu or mode.)

P13OF

p13t3

p13t3

p13t3

p13t3

p13t3

3

NOTE: The TMCC-3 baud rate can only be 4800 BPS.

n Table 2 : Transmission Delay Time Table

60

80 5 100

Id

Id

tr

tr

Id

13

50

3

50

13

TR-Time (ms)

120

140

160

180

- 64 - - 64 -

-

Page 68: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-3lOl5D

l Setting Grade Line (for SL-5900-36 only) You can set the maximum 49 kinds of grade line (26 character per line), and call one of them to print it to on the label.

Menu #.

Q ENTER

Enler the grade line #. (l-49) Enter the characters.

(max. 26 chara.Iline) I I

ti

ENTER

CII PROG.

. . . . . . . . . . . ..i.l........... y ‘:::::,:.:.:.~:,~~;,~~~,~:. :

I’$~~~: ; ;

,j3g@g.: ,.’ ~:.:.;.~:.r . . . . . :.i.,:.‘.: .::::i~.~i:~:i:i:j::::::::

\...s-L~~. --.-

P

PI7

P17

P17

P17

P17

P17

:. $.: r:,: __-.

- 66 -

Page 69: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

1 Menu No. 1% 1

l Memory Card (for SL-5900-36 only) PLUS are saved, compared, and loaded by using the memory card (128KB).

Menu #.

Save

Compare

Load

Data display

Format clear

PLU clear

-2

NEXT _ PLU

CLEAR

I A 1

-8 O-

‘-9 8-

ENTER

I I 1

P

P18

P18

P18

P18

P18

PI8

=‘18

u

‘18

=18

?18

P18

P18

u

P18

1

2

80

98

SurE

n (n = 80 or 98)

- 66 -

Page 70: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

NOTES: 1. If the PLU file cannot be saved into one memory card, the program will display the message “INS NAOTHER CARD”. Then, replace the memory card and press the ENTER key so that the following data will be saved. For cancellation, press the CLEAR key.

2. Comparision of the PLUS stored in the memory card and those in the scale terminates normally even if other PLUS are left in the scale memory. Evern if the PLU data of the scale ends, a data error results if other data is left in the memory card.

3. Of the PLUS stored in the memory card in loading the PLU file, the data found in the scale memory is overwritten and the data not found in it is added.

- 67 -

Page 71: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Error Information

The memory card is full (nothing has been saved). 0 F;yLORY CARD

-_-. ---~.. .- Format error (no PLU file is found in the memory card.)

o o FORMAT ERROR

irror -__-.--- ~--

Information Data Error 0 DATA ERROR

) No. of logos mismatched DIFF. # OF DATA

- 66 -

Page 72: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Transmitting PLU File or Unit Price (FUN System) Any terminal in the FUN system can transfer the data of its PLU file or unit price to other terminals for verification. In this case, the destination terminal (s) must be set in the REG mode.

Menu #.

Transmit PLU file.

Transmit unit price.

Verify PLU file.

Verity unit price.

(Select another menu or mode.)

., ./ . ::.‘.j:~~:::‘::.:.::.:~:.,.:.:. y...... . ..>>..:.:::::.::: ,. .:.:::;,:,:.:.:.:.:.:.:.:.%:,:., : . . . . . ..~.N!g.;.

f.:&$jg:;. :i.: :.::::.:.:.:.:.:...:.~:.: . . . . ..I. .I.... . . . . . . . . . . ..\.

P

P20

P20

P20

P20

P20

P20

P20

P

- . -::::::.:i::.::..:~~~.~: :.:.:.:.:... .:.:.:.::.~.:.:.

j ~~~~~

j F%tict

., .,. : ...:,:::l:.:i:~.j:‘si:~~

2

1

1

pon

2

1

2

1

2

n

0

-

NOTES: 1. When the PLU data has been changed using menu #l and the data is to be transferred to

other terminals through the operating procedure described above, the PLU file transfer is performed.

2. When the unit price has been changed using menu #Cl and the unit price is to be transferred to other terminals through the operating procedure described above, the unit price transfer is performed.

3. While receiving data, the terminals stop all operations.

- 69 .

Page 73: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Setting Clerk Name (for SL-5900-36 only)

Menu #.

No. of Clerks Max. 6

No. 01 Characters Max. 12

-1

-2 I

-3 I

-4 I

-5 I

ENTER v

- : ‘ : : : : : : , I : ‘ : ; : : : : : : : : : : : :

, , . 2:. . . \ : : . . : . c .._ . . . . . . .._

:y$@

, ; : , : . . , . . . . . . . A . . . . : . .

.@3~.@ . , ~. , . , , . : : , . . . . . .

_.. ii 1. . . . . . . . . . A . . . .

P

P21

P21

P21

P21

P21

P21

P21

P21

P21

- 70 -

Page 74: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

n Error Code during Transmitting

TOTAL PRICE

Error Code Phenomena

1-7 Hardware error 8 Verify error

1 Character over error 2 BCC error

4 Data error 8 Time out error

All errors occur in the receiving terminal. The error mode can be released by depressing the CLEAR key, then attempt to transmit again.

- ?l-

Page 75: TEC Electronic Computing Scale SL-5900 (US. Version)

EMl-31015D

l Setting Print Item #I ON/OFF The setting specifies whether each print item on the registered labels is to be printed or not.

Menu #.

Packed on date.

Sell by dale.

Commodity name.

Address.

Bar Code.

PROG.

4 P-+ 43 5

(Select another menu or mode.) I

P

P40

P40

P40

P40

P40

P40

P

-

[Position of Print item]

Commodity Name area

40

00000

00001

00010

00100

01000

10000

40

I Packed on dale Bar Code

Unit Price or Quanlity

Weight or Quanlily

Address area

‘Sell by date

. $ symbol

Total Price

- 72 -

Page 76: TEC Electronic Computing Scale SL-5900 (US. Version)

EMI -31015D

l Setting Print Item #2 ON/OFF The setting specifies whether each print item on the registered labels is to be printed or not.

Menu #.

Unit price.

Weight.

Total price.

$ symbol.

Quantity.

2 P-+ 3

-=:

4

(Select anolher menu or mode.)

P

P41

P41

P41

P4

P4

P41

P

41

00000

00001

00010

00100

01000

10000

41

- 73 -

Page 77: TEC Electronic Computing Scale SL-5900 (US. Version)

EM1 -310150

17. ERROR MESSAGE TABLE Take the following action if an error message has appeared on the total price display and/or message display (option) with the buzzer sounding.

he CLEAR key, and set the

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LABEL END

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRT FAILURE

MEMORY FULL = .~. .----___

e CLEAR key, and set after

CHARACT. OVERRUN pt is made to set more

__~__- TOTALS OVERFLOW Total memory has overflowed Depress the CLEAR key, and turn the

at the time of issuing a label.

I

control lock at “Z” position. Then sum up the overflowing memory.

~~~~-~~ - ..~..... PLU DATA ERROR Error of PLU data. Depress the CLEAR key, and check the

PLU data.

LABEL OVERRUN Label overrun. Depress the CLEAR key and the FEED key. Then remove the label.

OP The RAM quantity initial set Call for service. ,I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., data is different from the

OPTION RAM ERROR actual number of RAMS.

.

- 74 ”

Page 78: TEC Electronic Computing Scale SL-5900 (US. Version)

EM1 -31015D

H CMT/FUN

Time out error. Depress the CLEAR key.

BAD TAPE OR CMT Bad tape or CMT loader. Depress the CLEAR key, and change the

(Hardware error) tape or CMT loader. I

18. BEFORE YOU CALL FOR SERVICE It is our primary concern to give you full satisfaction and better service. If, however, any problem arises in connection with the operation of this scale, please check the following points before calling for service:

A) Is the power plug fully plugged into an AC outlet? B) Is the power turned ON? C) Is AC power being properly supplied to the outlet? (Check it using another electric appliance.) D) Check the circuit breaker. E) Has there been a power failure of any sort? F) Has the operation been carried out in the correct order?

This scale has been manufactured under strict quality control. If you have any trouble, however, DO NOT ATTEMPT TO FIX IT BY YOURSELF. Pull the power plug out of the outlet, and contact your TEC representative.

NOTE: The specifications are subject to change without notice.

- 75 -

Page 79: TEC Electronic Computing Scale SL-5900 (US. Version)

PRINTED IN JAPANE