Operating / Installation Instructions: VDSN,P Vacuum Switch Series © 2014 Vaccon Company 9 Industrial Park Road, Medway, MA 02053 Phone: (508) 359-7200 Visit Us Online at www.vaccon.com or email us at [email protected] 1. Do not use corrosive or flammable gas or liquid with this product. 2. Please use within the operang pressure range. Do not apply pressure beyond the recommended maximum pressure, permanent damage to the pressure sensor may occur. 3. Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be damaged and switch may malfuncon. 4. Turn power off before connecng wiring. Improper wiring or a short circuit will damage and/or cause malfuncon. 5. Do not use in environment containing steam or oil vapor. 6. This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases. 7. Wiring for pressure sensor should avoid power source line and high voltage line. If used in the same circuit, noise may cause malfuncon. 1000 units in mm

Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps Work

Operating / Installation Instructions: VDSN,P Vacuum Switch Series

© 2014 Vaccon Company

9 Industrial Park Road, Medway, MA 02053 Phone: (508) 359-7200

Visit Us Online at www.vaccon.com or email us at [email protected]

1. Do not use corrosive or flammable gas or liquid with this product.2. Please use within the opera�ng pressure range. Do not apply pressure beyond the recommended maximum pressure, permanent damage to the pressure sensor may occur.3. Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be damaged and switch may malfunc�on.

4. Turn power off before connec�ng wiring. Improper wiring or a short circuit will damage and/or cause malfunc�on.5. Do not use in environment containing steam or oil vapor.6. This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.7. Wiring for pressure sensor should avoid power source line and high voltage line. If used in the same circuit, noise may cause malfunc�on.

1000

units in mm

Page 2: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps WorkOperating / Installation Instructions: VDSN,P Vacuum Switch Series

Operating / Installation Instructions: VDSN,P Vacuum Switch – 2

Specifica�on Data / Values

Page 3: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps WorkOperating / Installation Instructions: VDSN,P Vacuum Switch Series

Operating / Installation Instructions: VDSN,P Vacuum Switch – 3

Page 4: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps WorkOperating / Installation Instructions: VDSN,P Vacuum Switch Series

Operating / Installation Instructions: VDSN,P Vacuum Switch – 4

Page 5: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps WorkOperating / Installation Instructions: VDSN,P Vacuum Switch Series

Operating / Installation Instructions: VDSN,P Vacuum Switch – 5

Page 6: Technical Brief: Vacuum System Design: Technical … › documents › operatinginstallation...Technical Brief: Vacuum System Design: Choosing The Correct Sized Tubing Operating

Technical Brief: Vacuum System Design:Choosing The Correct Sized Tubing

Technical Brief: How Vacuum Pumps WorkOperating / Installation Instructions: VDSN,P Vacuum Switch Series

Operating / Installation Instructions: VDSN,P Vacuum Switch – 6