21
Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16 Model: General Date: 3-Apr-15 No.: RGene082a RTB Reissue The items in bold italics were corrected or added. This is an instruction manual for NICE for registration Ver.1.1 or later. Table of Contents 1. Introduction.................................................................................................................... 2 1.1 What is ‘NICE for Registration’?................................................................................. 2 1.2 Service parts .............................................................................................................. 2 1.3 Supported models ...................................................................................................... 2 1.4 Front and back registration adjustment ...................................................................... 3 1.5 How to update the ‘NICE for registration’ SD card ..................................................... 3 2. Getting started ............................................................................................................... 4 2.1 How to activate ‘NICE for registration’........................................................................ 4 2.2 NICE menu screen ..................................................................................................... 5 2.3 Front/back registration adjustment procedure ............................................................ 7 Subject: NICE for Registration Ver.1.1 Prepared by: Akihiro Tajima From: 1st PP Tech Service Sec., PP Tech Service Dept., Classification: Troubleshooting Mechanical Paper path Product Safety Part information Electrical Transmit/receive Other ( ) Action required Service manual revision Retrofit information Tier 2

Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 1/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

RTB Reissue The items in bold italics were corrected or added.

This is an instruction manual for NICE for registration Ver.1.1 or later.

Table of Contents 1. Introduction .................................................................................................................... 2

1.1 What is ‘NICE for Registration’? ................................................................................. 2

1.2 Service parts .............................................................................................................. 2

1.3 Supported models ...................................................................................................... 2

1.4 Front and back registration adjustment ...................................................................... 3

1.5 How to update the ‘NICE for registration’ SD card ..................................................... 3

2. Getting started ............................................................................................................... 4

2.1 How to activate ‘NICE for registration’........................................................................ 4

2.2 NICE menu screen ..................................................................................................... 5

2.3 Front/back registration adjustment procedure ............................................................ 7

Subject: NICE for Registration Ver.1.1 Prepared by: Akihiro Tajima

From: 1st PP Tech Service Sec., PP Tech Service Dept.,

Classification: Troubleshooting

Mechanical

Paper path

Product Safety

Part information

Electrical

Transmit/receive

Other ( )

Action required

Service manual revision

Retrofit information

Tier 2

Page 2: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 2/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

1. Introduction

1.1 What is ‘NICE for Registration’?

‘NICE for registration’ is an application extracted from the NICE application, used exclusively for front/back registration adjustment.

‘NICE for registration’ can also be used by operators.

1.2 Service parts

Item P/N Parts description

NICE for registration SD card D0745100 SD-CARD:NICE:REGI:ASS'Y

1.3 Supported models

Pro C651ex/C751EX

Pro C7100S/C7100SX/C7110S/C7110SX

Pro C5100S/C5110S

Pro C901S

NOTE:

This SD card supports all the models listed below.

Version of ‘NICE for Registration’ is dependent on the system/copy firmware version. Make sure to apply the following firmware version combination.

NICE for registration *

Latest version (as of March 2016) version 1.1

*Older versions can be updated to the above versions.

Supported system/copy firmware version

Pro C7100/7110 3.02

Pro C751/651 1.15

Pro C5100S/5110S 1.11

Pro C901/901S 2.0

Page 3: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 3/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

1.4 Front and back registration adjustment

1.4.1 Method Automatically adjust the front/back registration by scanning the front/back sides of test chart 1.4.2 Requirements

Media applied with Custom Paper Settings

Supported media sizes: SRA3, A3, 13” x 19”, 12” x 18”, 11” x 17”, 315mm x 450mm, 318mm x 469mm , custom paper sizes between A4 and 13”x19”

Reference side (front or back) for the adjustment is as follows for each model:

- Pro C901 ................ : Front side - Pro C651/751 ......... : Back side - Pro C5100/5110 ..... : Front side - Pro C7100/7110 ..... : Front side

1.5 How to update the ‘NICE for registration’ SD card

1. Obtain the updater from GKM with the following Answer ID: 213503

2. Insert the NICE for registration SD card to the SD card slot. From Explorer,

delete the ‘image’ folder and ‘module’ folder. DO NOT delete the ‘gwinit.d’ folder.

3. Run the ‘7-zip updater’ to extract files to the root directory of the NICE SD card.

NOTE:

Update must be performed by the technician.

Root folder of SD Card

Page 4: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 4/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

2. Getting started

2.1 How to activate ‘NICE for registration’

1. Turn OFF the machine power.

2. Insert the ‘NICE for registration’ SD card into the service slot on the controller box.

3. Turn ON the machine power.

4. Press the Program key to display the NICE menu screen.

NOTE:

NICE SD card must be inserted to the service slot on the controller box, NOT the slot on the operation panel.

Make sure to turn OFF the machine power before removing the SD card from the card slot.

NICE for Registration does not activate automatically when turning ON the machine power. Press the Program key to activate.

Page 5: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 5/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

2.2 NICE menu screen (Example of Pro C7100/7110)

Main menu screen

Explanation of the menu items

01 Registration adjustment: Fine Fine adjusts the registration of front and back sides by scanning 6 times in total; front and back sides of 3 test charts.

02 Registration adjustment: Course Adjusts the registration of front and back sides by scanning twice in total; front and back sides of 1 test chart. While this adjustment is rather easy, if you require more precise

adjustment, do the above ‘Registration adjustment: Fine.‘

03 Registration adjustment: Reset

Returns to the status immediately before the last adjustment.

Language button switches between English and Japanese.

Page 6: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 6/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

Sub menu Opens the Debug log capture screen. Sub menu is accessed only by technicians.

NOTE: Menu of NICE for Registration is different depending on the version. Make sure to always maintain NICE for Registration to the latest version.

Sub menu screen

To display the sub menu screen, press the ‘Sub Menu’ button at the lower right of the main menu screen.

Pressing the ‘Debug log:Start’ button will immediately start the log capture until the machine power is turned off. Logs will be saved in the log directory in the SD card.

Page 7: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 7/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

2.3 Front/back registration adjustment procedure

1. Press ‘Registration adjustment: Fine’ or ‘Registration adjustment: Course’ on

the main menu screen.

2. Select the tray for the registration adjustment, and then press Select. Note that the adjustment is done for each tray.

Page 8: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 8/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

Page 9: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 9/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

NOTE: Adjustment is available only for trays associated with custom paper settings. Trays used under manual settings are greyed out and cannot be adjusted of the registration.

3. Press [Start OK] on the following screen.

4. Wait for the test chart to print out.

NOTE:

Page 10: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 10/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

The illustration above shows and example of the sequence when performing ‘Registration adjustment: Fine.’

Page 11: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 11/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

5. Confirm the following printouts:

Number of test charts printed differs depending on the adjustment (fine or course) performed.

- Registration adjustment: Fine: Test chart (x3), Blank sheet (3 copies printed respectively before and after the test chart)

- Registration adjustment: Course: Test chart (x1), Blank sheet (3 copies printed respectively before and after the test chart)

NOTE: Blank sheets will not be used for the adjustment.

Page 12: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 12/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

6. Press [Start OK] on the following screen.

Page 13: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 13/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

<Scanning the First (front) side>

7. Place the test chart so that the side described ‘FIRST’ faces up. Fold the 4 corners along the dotted lines (printed on the back side). For ‘Registration adjustment: Fine’, do the same for the remaining 2 charts.

For good results, fold along the line neatly and accurately.

8. Place the chart on the contact glass so that the side described ‘SECOND’ faces up

(because you will be scanning the FIRST side). Make sure the top and left edges of the chart are set flush against the edges of the contact glass.

‘FIRST’ faces up

‘SECOND’ faces up

Page 14: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 14/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

9. Press [Start OK] to start the scan.

Page 15: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 15/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

10. After the scan completes, remove the chart from the contact glass and press

[Start OK] on the following screen. For ‘Registration adjustment: Fine’, do the same for the 2 other charts.

NOTE: From the scanned data the software application in the NICE SD card reads the distance between the dotted lines along the folded edges and the paper edge on all 4 corners.

Page 16: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 16/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

NOTE: Error message will appear, if the chart was scanned incorrectly as in below.

The same chart was scanned. The wrong side of the chart was scanned. The chart was not placed correctly on the contact glass.

Press [Start Retry] and scan again to recover from the error.

Page 17: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 17/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

<Scanning the Second (back) side>

11. Flip the chart and fold the 4 corners along the dotted lines as done in step 7, but this time with the side described ‘SECOND’ facing up. For ‘Registration adjustment: Fine’, do the same for the 2 other charts.

12. Place the chart on the contact glass so that the side described ‘FIRST’ faces up (because you will be scanning the SECOND side). Make sure the top and left edges of the chart are set flush against the edges of the contact glass.

‘Second’ faces up

‘FIRST’ faces up

Page 18: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 18/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

13. Press [Start OK] to start the scan.

14. After the scan completes, remove the chart from the contact glass and press [Start OK] on the following screen. For ‘Registration adjustment: Fine’, do the same for the 2 other charts.

Page 19: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 19/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

The following screen will appear while the system makes the adjustments.

15. Press [Start OK] to print out the test charts and blank sheets, and check the results.

Page 20: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 20/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

NOTE:

Number of test charts printed differs depending on the adjustment (fine or course).

- Registration adjustment: Fine: Test chart (x3) and blank sheets (3 copies respectively before and after the test charts).

- Registration adjustment: Course: Test chart (x1) and blank sheets (3 copies respectively before and after the test charts).

15. Press [Start OK] to finish.

Page 21: Technical Bulletin PAGE: 1/21 Reissued: 23-Mar-16195.50.207.134/Tehdoc/0117/Disk4/copier/general/nice_reg.pdf · Technical Bulletin PAGE: 5/21 Reissued: 23-Mar-16 Model: General Date:

Technical Bulletin PAGE: 21/21

Reissued: 23-Mar-16

Model: General Date: 3-Apr-15 No.: RGene082a

16. Press the Program key and exit the NICE menu.