— TECHNICAL DATA

Emax 2 RenewableThe new solution for renewable application

Page 2: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

—Emax 2 RenewableThe new solution for renewable applications

Driven by the global trend of carbon dioxide reduction and diversified development of renewable energy, the clean energy resources such as wind power and solar photovoltaic are gradually becoming the backbone of our power supply. As one of the main suppliers of the global new energy industry, ABB has been committed to provide the high performance, high reliability and long service life product and electrical solution.

The Emax 2 Renewable air circuit-breaker is a spe-cial product for the renewable energy. It consists of three frames, respectively E1.2 RN, E2.2 RN and E4.2 RN, rated for the voltage up to 690VAC and current of 800A-4000A, available with fixed and with-

drawal type. Also Switch disconnectors are avail-able in the Emax 2 Renewable product portfolio. The new Emax 2 Renewable family provides full protection of the electrical equipment, thanks to the special high performances electronic trip units.

2 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 3: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

—Technical parameter

Emax 2 E1.2 RN E2.2 RN E4.2 RN

Performance level B N B N H N H V

Rated continuous current Iu (40°C) [A] 800 800 3200 3200 2500

[A] 1000 1000 1250 1250 4000 4000 3200

[A] 1250 1250 1600 1600 1600 4000

[A] 1600 1600 2000 2000 2000

[A] 2500 2500

Current carrying capacity of pole N of 4-pole circuit-breaker

%Iu 100 100 100 100 100 100 100 100

Rated limiting short-circuit break capacity Icu

440V [kA] 42 66 42 66 100 66 100 150

690V [kA] 42 50 42 66 85 66 85 100

Rated operating short-circuit break capacity Ics %Icu 100 100 100 100 100 100 100 100

Rated short-time withstand current Icw

1s[kA] 42 50 42 66 85 66 85 100

Rated short-circuit make capacity Icm (peak) Icm

440V [kA] 88 145 88 145 220 145 220 330

690V [kA] 88 105 88 145 187 145 187 220

Application classification (as per IEC 60947-2)

B B B B B B B B

With Maintenance: Iu[A] ≤ 1000 ≥1250 ≤ 1600 2000 2500 2500 3200 4000

Mechanical life Oper cycles * 1000 20 20 25 25 20 20 20 20

Electrical life 440V Oper cycles * 1000 8 8 15 12 8 10 7 7

690V Oper cycles * 1000 8 6.5 10 8 7 8 7 4

Emax 2/MS E1.2 RN E2.2 RN E4.2 RN

Performance level B/MS N/MS B/MS N/MS H/MS N/MS H/MS V/MS

Rated continuous current Iu (40°C) [A] 800 800 3200 3200 2500

[A] 1000 1000 1250 1250 4000 4000 3200

[A] 1250 1250 1600 1600 1600 4000

[A] 1600 1600 2000 2000 2000

[A] 2500 2500

Current carrying capacity of pole N of 4-pole circuit-breaker

%Iu 100 100 100 100 100 100 100 100

Rated short-circuit make capacity Icm (peak) Icm

440V [kA] 88 105 88 145 187 145 187 220

690V [kA] 88 105 88 145 187 145 187 220

Rated short-time withstand current Icw

1s[kA] 42 50 42 66 85 66 85 100

Application classification (as per IEC 60947-3)

AC23A AC23A AC23A AC23A AC23A AC23A AC23A AC23A

With Maintenance: Iu[A] ≤ 1000 ≥1250 ≤ 1600 2000 2500 2500 3200 4000

Mechanical life Oper cycles * 1000 20 20 25 25 20 20 20 20

Electrical life 440V Oper cycles * 1000 8 8 15 12 8 10 7 7

690V Oper cycles * 1000 8 6.5 10 8 7 8 7 4

1SD

C20

04

25F

00

1

1SD

C20

04

26F

00

1

1SD

C20

04

24F

00

1

Common features

Rated operating voltage Ue [V] 690

Rated insulation voltage Ui [V] 1000

Rated impulse withstand voltage Uimp

[kV] 12

Frequency [Hz] 50 - 60

Number of poles 3 - 4poles

TypeFixed type - withdrawable type

Insulation characteristics IEC 60947-2

3TECH N I C A L PA R A M E TER

Page 4: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

Compliant with the IEC60947 standard.From 800 to 4000 A, Fixed and drawout versions..

Two types of electronic release: Optional between Ekip DIP and Ekip LCD, realizing the quick break, overcurrent and earth protection functions etc., satisfying the special needs of clean energy industry.

Available with many function extension modules, such as communication, measurement and signal, to easily achieve system monitoring. Connectable to the ABB Ability™ Electrical Distribution Control System for data collection and remote monitoring.

Adopting new type of electronic components and high performance grease and mechanical parts of reliable performance and applicable to severe environment of extreme low temperature, including turbine cabinet.

Achieving the coordination with overcurrent protection in combination with contactor.

With compact size to meet the special space requirements of customer.

—Product Features

Emax E1.21600 A

300...400 400...600 600...800

Emax E2.22500 A

Emax E4.24000 A

4 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 5: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

—Electronic release

Ekip Dip dial type electronic release Ekip LCD type electronic release

The following protection functions are provided:

- Overload protection (L)

- Delayed overcurrent protection (S)

- Thermal memory

- Instantaneous overcurrent protection (I)

- Earth fault protection (G)

- Neutral line protection

Protection: LI - LSI - LSIG Protection: LI - LSI - LSIG

The following protection functions are provided:

- Overload protection (L)

- Delayed overcurrent protection (S)

- Thermal memory

- Instantaneous overcurrent protection (I)

- Short-circuit-proof closing protection (MCR)

- Earth fault protection (G)

- Neutral line protection

- Current unbalance protection

- Zone selectivity of S and G protection functions

- More suitable for the special severe environments, such as

low temperature, humidity and chemical pollution

Optional new modules:

Measurement Optional

Communications Optional

Signalling Optional

Bluetooth (wireless connection) Optional

Advanced protection Optional

5EL EC TR O N I C R EL E A SE

Page 6: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

E1.2 RN E2.2 RN - E4.2 RN

Signal indication

Standard auxiliary contact for opening/closing - AUX 4Q / /

Auxiliary contact for opening/closing - AUX 6Q - /

Auxiliary contact for opening/closing - AUX 15Q (mounting plate is required by E1.2) / /

Auxiliary contact for position indication - AUP

Closing ready signal contact - RTC / /

Mechanical signal indication for trip of protective release - TU reset / /

Electrical signal contact for trip of Ekip protective release - S51 / /

Spring charging signal contact - S33 M/2 (with electrical operation mechanism) / /

Control

Opening/closing coil - YO/YC / /

Second opening/closing coil - YO2/YC2 / /

Undervoltage release - YU / /

Electronic delay relay for undervoltage release - UVD / /

Motor - M / /

Remote reset - YR / /

Test unit of opening/closing coil - YO/YC test unit / /

Protective device

Protective device of opening/closing button - PBC / /

IP30 protection rating / /

IP54 protection rating / /

Terminal cover - HTC/LTC / -

Phase partition - PB / /

Connection

Adjustable back wiring terminal - HR/VR

Front wiring terminal - F

Other configurations / /

Standard accessories of fixed circuit-breaker Accessories of fixed circuit-breaker to be provided as demanded Standard accessories for withdrawable part Accessories for withdrawable part to be provided as demanded

Standard accessories for fixed part Accessories for fixed part to be provided as demanded

—Main accessories

6 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 7: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

Type Abbreviation E1.2 RN E2.2 RN E4.2 RN

Adjustable back wiring terminal (1) HR VR

F, W F, W F, W

Extended horizontal back wiring terminal SHR W F, W

Extended vertical back wiring terminal SVR F, W

Front wiring terminal F F F, W F, W

Lengthened front wiring terminal EF F, W

Extended front wiring terminal ES F, W

Wiring terminal for copper-aluminum cables 4x240mm2 Fc CuAl F, W

Horizontal wiring terminal (end face wiring) FL W W

(1) The standard configuration of adjustable back wiring terminal is HR-HR configuration.

—Connecting terminal

The wiring terminals of the circuit-breaker are complete and flexible. Therefore, it's very simple to install the circuit-breaker to the electrical system. It adopts the silver-plated copper terminal. It can connect to the distribution busbar according to the rated current carrying capacity of the circuit-breaker. Each wiring terminal is designed according to the width of the standard busbar. One, two or three years of wiring terminals can be configured for the circuit-breaker, so as to connect with the distribution system operating multiple busbars to meet the application need. For the special installation demand, the circuit-breaker can also be of different upper/lower terminal combinations.

7CO N N EC TI N G TER M I N A L

Page 8: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

—Model and Specification

E2.2 N 1250 RN-L FHR NST4 3

Optional installation method:

Accessory specificationNST: standard configuration

RN-D: Dip dial typeRN-L: LCD type

Note: L: Overload long delay S: short-circuit short delay I: Instantaneous short-circuit G: earth fault protection

Note:The default wiring method is horizontal back wiring (HR).

Optional frame current:

Optional release:

2: LI two-stage protection3: LSI three-stage protection4: LSIG four-stage protection

WMP: Withdrawable typeFHR: fixed type (E2.2 RN,E4.2 RN)F F: Fixed type front wiring (E1.2 RN)

Optional protection functions:

E1.2:Iu = 800~1600AE2.2:Iu = 1250~2500AE4.2:Iu = 2500~4000A

Optional frame code:

Break capacity @ 690VB: 42kA    N: 50-65kAH: 85kA   V: 100kA

E1.2B:800,1000,1250,1600E1.2N:800,1000,1250,1600

E2.2B:1600,2000E2.2N:1250,1600,2000,2500E2.2H:1250,1600,2000,2500

E4.2N:3200,4000E4.2H:3200,4000E4.2V:2500,3200,4000

3:3P    4:4P

Optional number of poles:

8 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 9: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

E1.2 RN E2.2 RN - E4.2 RN

A B C

[mm] 4 poles 3 poles 3 poles 4 poles

E1.2 RN 284 214 107 107

E2.2 RN 366 276 138 138

E4.2 RN 510 384 192 192

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

—Overall dimensionFixed type circuit-breaker

9OV ER A L L D I M ENSI O N

Page 10: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

E1.2 RN Standard Ronis lock / Profalux lock

Kirk lock

Castell lock

A MIN [mm] 49.5 63.5 63.5 83.5

A MAX [mm] 83.5 97.5 97.5 117.5

E2.2 RNE4.2 RN

Standard Ronis lock /Profalux lock

Kirk lock

Castell lock

A MIN [mm] 29.5 41.5 46.5 65

A MAX [mm] 69.5 81.5 86.5 105

E1.2 RN E2.2 RN - E4.2 RN

Compartment opening

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

15837

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

E1.2 RN E2.2 RN - E4.2 RN

Ø4 n°6 hole Ø5 n°8 hole

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

15837

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

24422

4

112

100

100

254XX

Y

Y12212

1

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

C

B

A

168.5

331

40

612

XX

Y

Y

B

A

Y

Y

x x

C

268 291

134

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

130 MIN

164 MAX

2

3 A MIN

A MAX A MAXA MIN

(88)

(48)

12.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

15319

2

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

1SD

C20

0580

F001

1SD

C20

0581

F001

1SD

C20

0582

F001

1SD

C20

0583

F001

—Overall dimensionFixed type circuit-breaker

10 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 11: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

A B C D

[mm] 3 poles 4 poles

E1.2 RN 250 322 382.5 * 130

E2.2 RN 400 490 500 221

E4.2 RN 500 600 500 221

* 332.5, applicable to the voltage ≤440V AC

Compartment dimension

AB

C

D

AB

C

D

1SD

C20

0571

F001

1SD

C20

0584

F001

—Overall dimensionFixed type circuit-breaker

11OV ER A L L D I M ENSI O N

Page 12: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

Ø 10 MAX

1SD

C20

058

7F0

01

[mm] 3 poles 4 poles

A 192.5 262.5

B 70 140

Wall mounted (only applicable to RN1)

1) Mounted using back wiring terminal

Grounding units E2.2 RN- E4.2 RN

Provide M5x8 screwTightening torque 3Nm

Floor mounted

A B C D

[mm] 3 poles 4 poles 3 poles 4 poles

E1.2 RN 117 187 117 117 80 5.5

E2.2 RN 154 244 154 154 150 10.5

E4.2 RN 208 334 208 208 150 10.5

Y

YBA (III)

A (IV)

C

=

=

XX

D

1SD

C20

0585

F001

XX

Y

Y

8

35

61.25

122.

5

245

42.7

5

59.7

5

17.55.5Ø - M5

10R

A

B

1)

1SD

C20

0586

F001

—Overall dimensionFixed type circuit-breaker

12 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 13: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

—Overall dimensionWithdrawable type circuit-breaker

E1.2 RN E2.2 RN - E4.2 RN

A B C

[mm] 4 poles 3 poles 3 poles 4 poles

E1.2 RN 348 278 155.5 155.5

E2.2 RN 407 317 158.5 158.5

E4.2 RN 551 425 212.5 212.5

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Compartment opening

E1.2 RN E2.2 RN - E4.2 RN

Ø4 n°8 hole Ø5 n°8 hole

13OV ER A L L D I M ENSI O N

Page 14: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

Distance from connecting point to isolation position

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

XX

Y

Y

306

348

100 100

158

37

100

153

179

226

244

224

112

100

100

254XX

Y

Y122

121

XX

Y

Y

306

374

100 100

158

50

100

153

192

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

Y

Y

xx363.5343

159.5

B

A

CC

B

A

Y

Y

X X

181.5

425

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

251 2

305

C

275.5B

40

3

3

C

47

B75

12.5

1SD

C20

0582

F001

1SD

C20

0588

F001

1SD

C20

0589

F001

1SD

C20

0590

F001

143,5143,5

23

138,

513

8,5

X X

Y

Y

161

262

150

274

19

E1.2 RN E2.2 RN - E4.2 RN

E1.2 RN Standard Ronis lock /Profalux lock

Kirk lock

Castell lock

B [mm] 44.5 55 55 83.5

C [mm] 36 46.5 46.5 117.5

E2.2 RNE4.2 RN

Standard Ronis lock /Profalux lock

Kirk lock

Castell lock

C [mm] 22 34 39 57.5

B [mm] 23 35 40 58.5

B indicates C; C indicates KLP.

—Overall dimensionWithdrawable type circuit-breaker

7

Y

Y

Y

F (III)

A (III) B (III)

B (IV)A (IV)

75

50

E (III)D (III)

E (IV)

D (IV)

=

= CXX

1

G

AB

C

D

AB

C

D

Y

Y

80 (III)

150 (IV)

100

80

44= =

25

33 3912.5

11Ø

15

44= =

N L1 L2 L3

Y

Y

707070

Y

Y

N L1 L2 L3

70707015

X X

100

236.5

57.5

15

49

203

251

271 15

2

1542

X 213

15

29

X

60.5

198

29

Y

2025020

30115

230

99.5

6.5Ø

193.5

44= = 2512.5

25

12.5

12.511Ø

200

73

15

XX

Y

Y155.5

278 (III)

348 (IV)

159.5

343363.5

239.5

132

7 2

73

1

5

6

8

4

10

4

2

7

3

4

8

8

III - 206IV - 276

III - 342IV - 456

100

271

251

7

271

251

1SD

C20

0570

F001

1SD

C20

0591

F001

1SD

C20

0592

F001

1SD

C20

0593

F001

Compartment dimension

A B C D

[mm] 3 poles 4 poles

E1.2 RN 280 350 440* 252

E2.2 RN 400 490 500 355

E4.2 RN 500 600 500 355

* 390, applicable to the voltage ≤440V AC

14 E M A X 2 R E N E WA B LE TH E N E W SO LU TI O N FO R R EN E WA B L E A PPL I C ATI O N

Page 15: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

7

Y

Y

Y

F (III)

A (III) B (III)

B (IV)A (IV)

75

50

E (III)D (III)

E (IV)

D (IV)

=

= CXX

1

G

AB

C

D

AB

C

D

Y

Y

80 (III)

150 (IV)

100

80

44= =

25

33 3912.5

11Ø

15

44= =

N L1 L2 L3

Y

Y

707070

Y

Y

N L1 L2 L3

70707015

X X

100

236.5

57.5

15

49

203

251

271 15

2

1542

X 213

15

29

X

60.5

198

29

Y

2025020

30115

230

99.5

6.5Ø

193.5

44= = 2512.5

25

12.5

12.511Ø

200

73

15

XX

Y

Y155.5

278 (III)

348 (IV)

159.5

343363.5

239.5

132

7 2

73

1

5

6

8

4

10

4

2

7

3

4

8

8

III - 206IV - 276

III - 342IV - 456

100

271

251

7

271

251

1SD

C20

0570

F001

1SD

C20

0591

F001

1SD

C20

0592

F001

1SD

C20

0593

F001

7

Y

Y

Y

F (III)

A (III) B (III)

B (IV)A (IV)

75

50

E (III)D (III)

E (IV)

D (IV)

=

= CXX

1

G

AB

C

D

AB

C

D

Y

Y

80 (III)

150 (IV)

100

80

44= =

25

33 3912.5

11Ø

15

44= =

N L1 L2 L3

Y

Y

707070

Y

Y

N L1 L2 L3

70707015

X X

100

236.5

57.5

15

49

203

251

271 15

2

1542

X 213

15

29

X

60.5

198

29

Y

2025020

30115

230

99.5

6.5Ø

193.5

44= = 2512.5

25

12.5

12.511Ø

200

73

15

XX

Y

Y155.5

278 (III)

348 (IV)

159.5

343363.5

239.5

132

7 2

73

1

5

6

8

4

10

4

2

7

3

4

8

8

III - 206IV - 276

III - 342IV - 456

100

271

251

7

271

251

1SD

C20

0570

F001

1SD

C20

0591

F001

1SD

C20

0592

F001

1SD

C20

0593

F001

A B C D E F G

[mm] 3 poles 4 poles 3 poles 4 poles 3 poles 4 poles 3 poles 4 poles

E1.2 RN 80 150 80 80 100 - - - - - 9

E2.2 RN 75 175 75 75 150 270 360 135 135 - 10

E4.2 RN 100 225 100 100 150 378 504 189 189 - 10

Floor mounted

Grounding devices E2.2 RN-E4.2 RN Fixed on supporting steel plate (only applicable to E1.2 RN)

Provide M5x8 screwTightening torque 3Nm

7

Y

Y

Y

F (III)

A (III) B (III)

B (IV)A (IV)

75

50

E (III)D (III)

E (IV)

D (IV)

=

= CXX

1

G

AB

C

D

AB

C

D

Y

Y

80 (III)

150 (IV)

100

80

44= =

25

33 3912.5

11Ø

15

44= =

N L1 L2 L3

Y

Y

707070

Y

Y

N L1 L2 L3

70707015

X X

100

236.5

57.5

15

49

203

251

271 15

2

1542

X 213

15

29

X

60.5

198

29

Y

2025020

30115

230

99.5

6.5Ø

193.5

44= = 2512.5

25

12.5

12.511Ø

200

73

15

XX

Y

Y155.5

278 (III)

348 (IV)

159.5

343363.5

239.5

132

7 2

73

1

5

6

8

4

10

4

2

7

3

4

8

8

III - 206IV - 276

III - 342IV - 456

100

271

251

7

271

251

1SD

C20

0570

F001

1SD

C20

0591

F001

1SD

C20

0592

F001

1SD

C20

0593

F001

Legend:

1 Ventilation hole of switch cabinet

—Overall dimensionWithdrawable type circuit-breaker

15OV ER A L L D I M ENSI O N

Page 16: TECHNICAL DATA Emax 2 Renewable The new …...2 EMA 2 RENEWABLE THE NEW SOLUTION FOR RENEWABLE APPLICATION — Technical parameter Emax 2 E1.2 RN E2.2 RN E4.2 RN Performance …

1 S

XF

200

025

L020

1 R

ev A

06

20

17S

H-J

S

—Contact us:http://www.abb.com.cnABB China Cusotmer Service Hotline Tel. 800-820-9696 / 400-820-9696 E-mail [email protected]

The product information contained in the sample is subject to the physical product and my change without prior notice. ABB (China) Co., Ltd. reserves the final explanation right.

ABB中国客户服务中心