technical data type PLX diffuser in PMMA : < 0.22 Nm Reflector : white metal gear tray Base : Glass reinforced polyester, compression moulded (GRP) - Optional : Double cable entry (same side). : Stainless steel suspension bracket. - Optional - Optional : PWG60 : quick installation grommet. IP65 Diffuser : lined diffuser available in PMMA, or PC. Impact strength data of the diffuser : diffuser in PC : > 6 Nm Clips : 3-part polycarbonate clips or 2-part stainless steel clips - Optional : Bright anodised aluminium mirror - compact fluorescent lamp versions on request - ferromagnetic ballast and switch or electronic starters - optional: - parallel compensation - throughwiring in polyester housing: - emergency modules in option: Lamps : - T5 in 28w - 35w - 49w - 54w - 80w available - low loss ballast Electrical specifications : - HF or HFD ballast - fluorescent T8 lamps in 18w - 36w - 58w - 70w 1 or 3 fase (3 x 2.5 mm²) (5 x 2.5 mm²) (optional) Metal clip LUX V Vandal proof clip (optional) Stainless steel susp. bracket (optional) Alum. reflector (optional) Stainless steel susp. bracket (optional) (Option) CLASS II IP65 F Double cable-entry (optional) V 11.04.2019

technical data type PLX - Vlux · 2019-04-11 · technical data type PLX VLUX Industrieweg Roosveld Tel + 32 11 88 09 00 website 3400 LANDEN BELGIUM Fax + 32 11 83 22 22 ISO 9001

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: technical data type PLX - Vlux · 2019-04-11 · technical data type PLX VLUX Industrieweg Roosveld Tel + 32 11 88 09 00 website 3400 LANDEN BELGIUM Fax + 32 11 83 22 22 ISO 9001

technical data type PLX

diffuser in PMMA : < 0.22 Nm

Reflector : white metal gear tray

Base : Glass reinforced polyester, compression moulded (GRP)

- Optional : Double cable entry (same side). : Stainless steel suspension bracket.- Optional

- Optional : PWG60 : quick installation grommet. IP65

Diffuser : lined diffuser available in PMMA, or PC.

Impact strength data of the diffuser :

diffuser in PC : > 6 Nm

Clips : 3-part polycarbonate clips or 2-part stainless steel clips

- Optional : Bright anodised aluminium mirror

- compact fluorescent lamp versions on request

- ferromagnetic ballast and switch or electronic starters - optional: - parallel compensation

- throughwiring in polyester housing:

- emergency modules in option:

Lamps :

- T5 in 28w - 35w - 49w - 54w - 80w available

- low loss ballast

Electrical specifications :

- HF or HFD ballast

- fluorescent T8 lamps in 18w - 36w - 58w - 70w

1 or 3 fase (3 x 2.5 mm²) (5 x 2.5 mm²)

(optional)Metal clip

LUXV

Vandal proof clip(optional)

Stainless steel susp. bracket (optional)

Alum. reflector(optional)

Stainless steel susp. bracket (optional)

(Option)CLASS IIIP65F

Double cable-entry(optional)

V 11.04.2019

Page 2: technical data type PLX - Vlux · 2019-04-11 · technical data type PLX VLUX Industrieweg Roosveld Tel + 32 11 88 09 00 website 3400 LANDEN BELGIUM Fax + 32 11 83 22 22 ISO 9001

technical data type PLX

VLUX Industrieweg Roosveld Tel + 32 11 88 09 00 website www.vlux.com3400 LANDEN BELGIUM Fax + 32 11 83 22 22 ISO 9001 certified company

WL

Lf

H

LUXV

1x 36W 1x28W 1312 102 105 800 8

*Dimensions without clips

1x 58W 1x35/49W 1612 102 105 1100 10

1x 18W 1x14/24W 702 102 105 500 6Model T8 Model T5 L W* H Lf Clips

2x 18W 2x14/24W 702 172 105 500 6

2x 58W 1x80W / 2x35/49W 1612 172 105 1100 102x 36W 1x54W / 2x28W 1312 172 105 800 8

2x70W 1874 172 105 1100 14

K

Ceilings

C.I.E.: 34 62 83 90

Correction factors : 18W: 0.93 36W: 1.00 58W: 0.95

Utilisation Factors

PLX mono

Lum.Eff.: 77.0 % ( )e/h : 1.64

50/DIV

4.00

3.00

2.50

5.00

1.00

0.80

1.25

2.00

1.50

Floor

Walls

0.60

Polair Diagram Glare Evaluation

.3

.5

.8

.1

.5

.7

.3

.3

.7

.3

.5

.5

55

45

.3

.3

.5

.1

.3

.5

65

75

Qualityclass

85

C

E

D

B

(1x2850 lm)

1000

Service illuminance (Lux)

2 3 4

1.15

1.85

2.55

G

1.5 1000

1000

1000

500

500

300

cd/m

6 8 102

h

4

300 500

300

300

500

8

2

64

3.51 .45 .42 .46 .39 .38

.56 .49 .46 .50 .44 .41

.31 .29 .24 .29 .23 .22

.39 .35 .30 .35 .29 .28

.45 .40 .36 .40 .34 .33

.63 .55 .54 .56 .50 .47

.77 .65 .69 .68 .64 .59

.81 .68 .73 .71 .67 .62

.68 .59 .59 .60 .55 .52

.72 .62 .63 .64 .59 .55

BZ6 UTE : .69G+.08T

Room ind.

K

Ceilings

C.I.E.: 38 67 88 93

Correction factors : 18W: 0.95 36W: 1.00 58W: 0.94

Utilisation Factors

PLX DUO

Lum.Eff.: 72.0 % ( )e/h : 1.64

50/DIV

4.00

3.00

2.50

5.00

1.00

0.80

1.25

2.00

1.50

Floor

Walls

0.60

Polair Diagram Glare Evaluation

.3

.5

.8

.1

.5

.7

.3

.3

.7

.3

.5

.5

55

45

.3

.3

.5

.1

.3

.5

65

75

Qualityclass

85

C

E

D

B

(2x2850 lm)

1000

Service illuminance (Lux)

2 3 4

1.15

1.85

2.55

G

1.5 1000

1000

1000

500

500

300

cd/m

6 8 102

h

4

300 500

300

300

500

8

2

64

3

.38 .35 .30 .35 .29 .28

.44 .40 .36 .40 .34 .33

.50 .45 .41 .45 .40 .38

.31 .29 .24 .29 .23 .22

.78 .66 .71 .69 .66 .61

.55 .48 .46 .49 .44 .42

.67 .58 .58 .60 .55 .52

.62 .54 .53 .56 .50 .48

.75 .64 .68 .67 .63 .58

.70 .60 .62 .63 .59 .54

BZ6 UTE : .67G+.005T

Room ind.