Upload
others
View
36
Download
0
Embed Size (px)
Citation preview
Dorset Log CabinTechnical Details
For Queries and Helpplease access our Support Centre:
www.gardenbuildingsdirect.co.uk/help
PROPRIETARY AND CONFIDENTIALITYAll the information contained within this document including all technical data, dimensions, shape/form and branding (inc. Trademarks, logos, etc.) Is the sole property of Kybotech Limited. The reproduction and/or disclosure to any third party of any information contained within this document is strictly prohibited. Breaches of the copyright will be dealt with on the highest level of severity with immediate legal proceedings.
© July 2014 - BillyOh.com
©
gardenbuildingsdirect .co.uk
In association with
Dorset Log CabinTechnical Details
©
Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding
Side elevation: depth 2.5m - Plain Side
Overall Building Depth: Includes Overhangall thicknesses = 2.820m/9’ 3”
Building Wall Depth 28mm = 2.576m/8’ 5” 35mm = 2.590m/8’ 6” 44mm = 2.608m/8’ 7”
Internal Depth all thicknesses = 2.334m/7’ 8”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
Inte
rnal
Eav
es H
eigh
t19
mm
Flo
or =
2.0
33m
/6’ 8
”11
mm
Flo
or =
2.0
41m
/6’ 8
”
Inte
rnal
Rid
ge H
eigh
t19
mm
Flo
or =
2.3
94m
/7’ 1
0”11
mm
Flo
or =
2.4
02m
/7’1
1”
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 5.334m/17’ 6”
Overall Building Widthall thicknesses = 5.652m/18’ 7”
Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’ 5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.5m x D2.5m / W18’1” x D8’2”Dorset: Front elevation
Total Bearer Length = 5.422m/17’ 9”
Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8’ 11”
Minimum Base Width = 5.502m/18’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
2.5
02m
/8’ 3
”O
uter
Bea
rer D
ista
nce
28m
m =
2.3
90m
/7’ 1
0”35
mm
= 2
.404
m/7
’ 11”
44m
m =
2.4
22m
/7’ 1
1”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er =
0.3
33m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.734m/15’ 6”
Overall Building Widthall thicknesses = 5.052m/16’ 7”
Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’ 5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.0m x D2.5m / W16’5” x D11’6”Dorset: Front elevation
Total Bearer Length = 4.822m/15’ 10”
Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”
Minimum Base Width = 4.880m/16’ 0”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
2.5
02m
/8’ 3
”
Out
er B
eare
r Dis
tanc
e28
mm
= 2
.390
m/7
’ 10”
35m
m =
2.4
04m
/7’ 1
1”44
mm
= 2
.422
m/7
’ 11”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er =
0.3
33m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.134m/13’ 7”
Overall Building Widthall thicknesses = 4.452m/14’ 7”
Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’ 6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.5m x D2.5m / W14’9” x D11’6”Dorset: Front elevation
Total Bearer Length = 4.222m/13’ 10”
Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”
Minimum Base Width = 4.280m/14’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
2.5
02m
/8’ 3
”
Out
er B
eare
r Dis
tanc
e28
mm
= 2
.390
m/7
’ 10”
35m
m =
2.4
04m
/7’ 1
1”44
mm
= 2
.422
m/7
’ 11”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er=
0.3
33m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 3.834m/12’ 7”
Overall Building Widthall thicknesses = 4.152m/13’ 7”
Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’ 6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.0m x D2.5m / W13’1” x D11’6”Dorset: Front elevation
Total Bearer Length = 3.922m/12’ 10”
Bearer Length = 1.961m/6’ 5”Bearer Length = 1.961m/6’ 5”
Minimum Base Width = 3.980m/13’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
2.5
02m
/8’ 3
”O
uter
Bea
rer D
ista
nce
28m
m =
2.3
90m
/7’ 1
0”35
mm
= 2
.404
m/7
’ 11”
44m
m =
2.4
22m
/7’ 1
1”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er=
0.3
33m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
© Dorset Log Cabin
Technical Details
Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding types
Side elevation: depth 3.5m - Side WindowOverall Building Depth: Includes Overhang
all thicknesses = 4.042m/13’ 3”
Building Wall Depth 28mm = 3.476m/11’ 5” 35mm = 3.490m/11’ 5” 44mm = 3.508m/11’ 6”
Internal Depth all thicknesses = 3.234m/10’ 7”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
Inte
rnal
Eav
es H
eigh
t19
mm
Flo
or =
2.0
33m
/6’ 8
”11
mm
Flo
or =
2.0
41m
/6’ 8
”
Inte
rnal
Rid
ge H
eigh
t19
mm
Flo
or =
2.3
94m
/7’ 1
0”11
mm
Flo
or =
2.4
02m
/7’1
1”
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 5.334m/17’ 6”
Overall Building Widthall thicknesses = 5.652m/18’ 7”
Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.5m x D3.5m / W18’1” x D11’6”Dorset: Front elevation
Total Bearer Length = 5.422m/17’ 9”
Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8 11”
Minimum Base Width = 5.502m/18’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
3.4
02m
/11’
2”
Out
er B
eare
r Dis
tanc
e28
mm
= 3
.290
m/1
0’ 1
0”35
mm
= 3
.304
m/1
0’ 1
0”44
mm
= 3
.322
m/1
0’11
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er0.
325m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.734m/15’ 6”
Overall Building Widthall thicknesses = 5.052m/16’ 7”
Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.0m x D3.5m / W16’5” x D11’6”Dorset: Front elevation
Total Bearer Length = 4.822m/15’ 10”
Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”
Minimum Base Width = 4.880m/16’ 0”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
3.4
02m
/11’
2”O
uter
Bea
rer D
ista
nce
28m
m =
3.2
90m
/10’
10”
35m
m =
3.3
04m
/10’
10”
44m
m =
3.3
22m
/10’
11”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er=
0.3
25m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.134m/13’ 7”
Overall Building Widthall thicknesses = 4.452m/14’ 7”
Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.5m x D3.5m / W14’9” x D11’6”Dorset: Front elevation
Total Bearer Length = 4.222m/13’ 10”
Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”
Minimum Base Width = 4.302m/14’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
3.4
02m
/11’
2”
Out
er B
eare
r Dis
tanc
e28
mm
= 3
.290
m/1
0’ 1
0”35
mm
= 3
.304
m/1
0’ 1
0”44
mm
= 3
.322
m/1
0’11
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er=
0.3
25m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 3.834m/12’ 7”
Overall Building Widthall thicknesses = 4.152m/13’ 7”
Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.0m x D3.5m / W13’1” x D11’6”Dorset: Front elevation
Total Bearer Length = 3.922m/12’ 10”
Bearer Length = 1.961m/6’ 5” Bearer Length = 1.961m/6’ 5”
Minimum Base Width = 3.980m/13’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
3.4
02m
/11’
2”
Out
er B
eare
r Dis
tanc
e28
mm
= 3
.290
m/1
0’ 1
0”35
mm
= 3
.304
m/1
0’ 1
0”44
mm
= 3
.322
m/1
0’ 1
1”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er=
0.3
25m
/1’ 1
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT38PT
38PT38PT
38PT
38PT
38PT
38PT
75PT75PT
75PT75PT
75PT75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
© Dorset Log Cabin
Technical Details
Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding types
Side elevation: depth 4.5m - Side WindowOverall Building Depth: Includes Overhang
all thicknesses = 4.659m/15’ 3”
Building Wall Depth 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’ 6”
Internal Depth all thicknesses = 4.134m/13’ 7”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
Inte
rnal
Eav
es H
eigh
t19
mm
Flo
or =
2.0
33m
/6’ 8
”11
mm
Flo
or =
2.0
41m
/6’ 8
”
Inte
rnal
Rid
ge H
eigh
t19
mm
Flo
or =
2.3
94m
/7’ 1
0”11
mm
Flo
or =
2.4
02m
/7’1
1”
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 5.334m/17’ 6”
Overall Building Widthall thicknesses = 5.652m/18’ 7”
Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.5m x D4.5m / W18’1” x D14’9”Dorset: Front elevation
Total Bearer Length = 5.422m/17’ 9”
Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8 11”
Minimum Base Width = 5.502m/18’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
4.3
02m
/14’
1”
Out
er B
eare
r Dis
tanc
e28
mm
= 4
.190
m/1
3’ 9
”35
mm
= 4
.204
m/1
3’ 1
0”44
mm
= 4
.222
m/1
3’10
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er0.
296m
/1’ 0
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.734m/15’ 6”
Overall Building Widthall thicknesses = 5.052m/16’ 7”
Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’5”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W5.0m x D4.5m / W18’1” x D14’9”Dorset: Front elevation
Total Bearer Length = 4.822m/15’ 10”
Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”
Minimum Base Width = 4.902m/16’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
4.3
02m
/14’
1”
Out
er B
eare
r Dis
tanc
e28
mm
= 4
.190
m/1
3’ 9
”35
mm
= 4
.204
m/1
3’ 1
0”44
mm
= 4
.222
m/1
3’10
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er0.
296m
/1’ 0
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 4.134m/13’ 7”
Overall Building Widthall thicknesses = 4.452m/14’ 7”
Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.5m x D4.5m / W14’9” x D14’9”Dorset: Front elevation
Total Bearer Length = 4.222m/13’ 10”
Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”
Minimum Base Width = 4.302m/14’ 1”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
4.3
02m
/14’
1”
Out
er B
eare
r Dis
tanc
e28
mm
= 4
.190
m/1
3’ 9
”35
mm
= 4
.204
m/1
3’ 1
0”44
mm
= 4
.222
m/1
3’10
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er0.
296m
/1’ 0
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)
Doo
r Hei
ght
all t
hick
ness
es =
1.8
76m
/6’ 2
”
Internal Width all thicknesses = 3.834m/12’ 7”
Overall Building Widthall thicknesses = 4.152m/13’ 7”
Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’6”
Exte
rnal
Rid
ge H
eigh
tal
l thi
ckne
sses
= 2
.470
m/8
’ 1”
Win
dow
Op
enin
g H
eigh
tal
l thi
ckne
sses
= 1
.217
m/4
’ 0”
Exte
rnal
Eav
es H
eigh
tal
l thi
ckne
sses
= 2
.090
m/6
’ 10”
W4.0m x D4.5m / W13’1” x D14’9”Dorset: Front elevation
Total Bearer Length = 3.922m/12’ 10”
Bearer Length = 1.961m/6’ 5” Bearer Length = 1.961m/6’ 5”
Minimum Base Width = 4.002m/13’ 2”
Min
imum
Bas
e D
epth
all t
hick
ness
es =
4.3
02m
/14’
1”
Out
er B
eare
r Dis
tanc
e28
mm
= 4
.190
m/1
3’ 9
”35
mm
= 4
.204
m/1
3’ 1
0”44
mm
= 4
.222
m/1
3’10
”
Bear
er S
pac
ing
from
cen
tre
of e
ach
bear
er0.
296m
/1’ 0
”
Front of Building
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
38PT
75PT
75PT
75PT
Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.
Base Size and Bearers Layout (Pressure Treated)