Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Technical Fact Sheet
Updated: January 2018
page 2
Contents Page
Main House Production Lighting Information 3
Brail Floor and Lighting Bridges Circuit Plan 4
Stage and Tier Fronts Lighting Circuits 5
Brail Floor & Bridges DMX & House light Control Points 6
Stage & Tier Fronts DMX & House Light Control Points 7
Main Stage Dimensions 8
RSJ Grid Measurements 9
Counter - weight distance from Setting Line 10
Lantern Information 11
Lighting Accessories 13
Other available equipment to hire 13
Orchestra Pit Equipment 13
Main House Production Sound 14
Sound Boards 15
Available Sound Equipment 16
Stage Power Distribution 18
Rigging and Staging Equipment 19
Main Auditorium Seating 20
Dressing room & performance space capacities 20
Auditorium Measurements 21
Cellar Production Lighting Information 22
Cellar Production Sound Information 22
Cellar Theatre 23
Courtyard 24
Attic Theatre 25
page 3
Main House Production Lighting Information
Lighting Desk: ETC Ion Memory Lighting Control Desk
2x LCD Touchscreen
ETC Universal Fader Wing
Riggers: ETC focus HAND 3 remote
Dimmers: ETC Sensor 3 - 162 x 3kw 10A circuits
ETC Sensor 3 - 16 x 5kw 25A circuits
ETC Sensor 3 - 2x 2.3kw spare hard power packs
Other Dimmers: 1 x 6 channel Zero 88 BETAPACK 3 dimmer (32A 3phase)
3 x 6 channel Anytronics dimmer pack (32A 3phase)
3kw Circuits 5kw Circuits
Control Room: 1 - 4 (4 circuits) Main House: 109 - 124 (16 circuits)
Stage D/S/L and R: 5 - 20 (16 circuits)
Brail Floor: 21 - 50 (30 circuits)
Tier 2 & Front tiers: 51 - 64 (14 circuits)
Bridge: 65 - 108 (44 circuits)
Stage U/S/L and R: 125 - 140 (16 Circuits)
Brail Floor: 141 - 155 (15 Circuits)
Brail Floor: 156 - 170 (15 Circuits)
Tier 1: 171 - 178 (8 Circuits)
DMX Ports House Lights Circuits (DMX)
Total DMX outs: 21 500 = Donut
Total DMX Ins: 4 501 = Stalls S/L – underside
502 = Stalls S/R and back - underside
503 = Tier 2 S/L - underside
504 = Tier 2 S/R and back - underside
505 = Tier 2 S/R - chandeliers
Dimmer Room DMX Patch Bay: 506 = Tier 2 S/L – chandeliers
2x Chauvet - Data Stream 4 507 = Tier 1 S/R and back – underside
1x +Swisson Pro DMX-512 & RDM hub 508 = Tier 1 S/L - underside
509 = Tier 1 S/L – chandeliers
Total number of DMX splitters: 18 510 = Tier 1 S/R - chandeliers
511 = Flood circuit A - Auditorium workers
512 = Flood circuit B - Stage workers
Control room in rear of tier 2
page 4
page 5
page 6
Brail Floor & Bridges DMX & House light Control Points
Total DMX Outs = 4
Total DMX Outs = 7
7
5
6
8
17
19
15
16
18
20
21
DMX Out
DMX In
House light Control
page 7
page 8
page 9
page 10
Counter - weight distance from Setting Line
CWT No Setting Line Bar Length Information
1 0.42m 13.60m House TABs
2 0.82m 13.60m
3 1.22m 13.60m
4 1.62m 13.60m
5 2.02m 13.60m Black TAB
6 2.42m 13.60m
7 2.82m 13.60m Projector Screen
8 3.22m 13.60m
9 3.62m 13.60m
10 4.02m 13.60m
11 4.42m 13.60m
12 4.82m 13.60m
13 5.22m 13.60m
14 5.62m 13.60m
15 6.02m 13.60m
16 6.42m 13.60m
17 6.82m 13.60m
18 7.22m 13.60m
19 7.62m 10.50m
20 8.02m 10.50m
21 8.42m 9.00m
22 8.82m 6.50m
Distance between bars = 0.40m
Flying 22 single - purchase c/wts SWL = 500kg
page 11
Lantern Information
Profile
Lanterns Wattage Beam Angle Gobo Size Number Comments
ETC Source Four Junior 575w 25 - 50 M 30
ETC Source Four Zoom 575w 15 - 30 B 13
ETC Source Four Fixed 575w - B 12
Fixed - 26 deg tube - 26 - 14
Fixed - 36 deg tube - 36 - 9
Fixed - 50 deg tube - 50 - 8
ADB Medium (DS 105) 1kw 15 - 31 A 8 Fixed FOH Rig
ADB A Range (A 59 Z) 650w 16 - 35 M 11 Cellar
Prelude Zoom 650w 28 - 40 B Attic
Prelude Zoom 650w 16 - 30 B 5 Attic
Fresnel
Lanterns Wattage Beam Angle Filter Size Number Comments
Cantata F 1.2kw 8 - 50 185 x 185 42
ADB Europe (F201) 2kw 12 - 61 245 x 245 8
ADB A Range (A57F) 650w 14 - 59 155 x 155 Cellar
ARRI Junior 5k 15 - 54 2
CCT Frebble F 500w 4
Prelude PC 650w 7 Attic
Barn doors for all Fresnel's
page 12
Other
Lanterns Wattage Beam Angle Filter Size Number Comments
Domino Floods (DOM1000) 1kw 8 - 50 15
Thomas Floods 1 cell 1kw 12 - 61 5
Parcan 64 (Black) 1kw 14 - 59 51
Parcan 56 (Black) 300w 15 - 54 13
Parcan 56 (Chome) 300w 20 Fixed Cellar Rig
Chauvet ColorRado 1-Tri Tour LED 8 Cellar
Showtech LED Par 56 2 Cellar
Pin-spots 30w 6
Par 16 Birdies 50w 6
UV cannons 400w 3
page 13
Lighting Accessories
6x Iris S4 Jr (575w profiles)
14x Iris S4 Fix / Zoom (575kw profiles) 24x Gobo holders – M-size (S4 Jr profiles) 16x Gobo holders – B-size (S4 Fixed / Zoom profiles) 10x Wooden Bench stands 8x BULLDOG Floor stands (BRAC10)
5x Tall stands (4ft 6”) Telescopic 4x Manfrotto wind-up stands 7x Metal boom bases (Tank Trap) 2x Chauvet Data Stream 4 DMX splitter
21x IWBs
Various lengths of 6 way muiltcore cable with Harting Connectors
Other available equipment to hire
1x Showtec Starsky II RGB Starcloth (12m x 6m) 2x Strand solo CID follow spots operated from either box on tier
1x Martin – Jem ZR 33 smoke machine 1x Martin – Jem ZR12 smoke machine 1x Martin – Jem compact Hazer Pro 1x Martin – Jem Atomic strobe 3000
1x Martin – Jem DMX Fan
2x Animation disk motor units (1 & 2 rpm) Various Le Maitre Pyro units & pods
Harlequin black / grey reversible dance-floor to cover the stage
Orchestra Pit Equipment
14x RAT Music Stands 1x RAT Double Music Stand 2x Long 13A extension cable for RAT stands
page 14
Main House Production Sound
Main Proscenium Arch Speakers: 4x d&b E9 (tier 1 and 2) 2x d&b E18 sub-bass (stage) 2x d&b E3 (tier 2)
Additional delays side/front-fill: 4x d&b E3 4x Tier 1 Balcony: EV S40B (pairs) 4x Tier 2 Balcony: EV S40B (pairs)
Crossover: 2x DSP based audio processing unit: XTA DP200 EQ & Delay
Amps: 2x d&b DP1200A amps 2x Ashly FTX 1500m (300 watts rms, 4 ohm load)
(For Thrust productions, All 6 d&b E3 speakers rigged around thrust @ stage level
& d&b E9 speakers flown from FOH lighting bridge.)
Mixing: Allen & Heath ZED-16FX
Playback: Denon Twin CD/MP3 Player (DN-D4500)
Main House Communication
Full facilities on SM desk including: 2-channel intercom
15-station cue light system
Show relay & paging system
Video show relay
11x Canford Tech-pro BP111
11x Canford Tech-pro SMH210
Tour Guide System
We have a Sennheiser tour guide system with option of Stethoset receivers or neck induction loop.
These can be booked though Box Office
page 15
Sound Boards
Area Sound Board Location
Stage: SB 101 D / S / L
SB 107 D / S / R
SB 104 U / S / L
SB 105 U / S / C
SB 106 U / S / R
Orchestra Pit SB 001 S / L
SB 002 S / R
Donut SB 402 Front of Donut
Control Room SB 308
Stalls SB 111 FOH Sound Position (L Row)
Cellar SB 010 Control Room
page 16
Available Sound Equipment
Mixing desks: Play Back:
Yamaha LS9 32
Denon twin DN2300 mini-disc recorder Yamaha SB168-ES 16/8 stage box
Tascam MD-350 Mini Disk player Spirit Powerstation 600
TEAC CD player Behringer Xenyx 802 Mixer
Behringer DJ Mixer VMX 100
Other Speakers: Out Board:
EV S80B 7 Digi Tech studio Reverb TSR – 12
EV S2002 Behringer Multicon pro – XL MDX 4600
EV SX300 4 Behringer Multicon pro – MDX 4400 Dynamics Processor
Bose-101 4 2 x Ashley GQX 3102 Graphic Equalizer
Martin WMO.5 wedges (monitors) 4 Yamaha Graphic Equalizer Q2031A Yamaha Graphic Equalizer Q2031B
BSS FDS – 360 with Compressor / Limiter
Other Amps: DI Boxes:
4x Ashley FTX 1500m (300 watts rms, 4 ohm load) 2x BSS Audio 116 D.I. boxes
(Fixed Main house control room) 2x Behringer Ultra – DI D100
2x Ashley FTX 1500m (300 watts rms, 4 ohm load) (cellar) 1x Behringer Ultra – DI D120 (2 channels) 1x Behringer Ultra – DI D800 (8 Channels)
3x Artcessories DTI Box3
Microphones: Stands:
8x Shure Sm58 11x Tall Microphone stands Black 6x Shure Sm57 3x Short Microphone stands
5x AKG SE300 with CK91 heads 5x Tall Microphone Stands Silver 5x Speaker stands
4x Beyer Dynamic MCE 86N 1x Beyer Dynamic M260
2x Beyer Dynamic M700 Other: 2x Sennheiser MD504D
1x 16 way sound multi-core(Gray) 12m 1x Sennheiser MKH 416
page 17
1x Ethernet100m Ether sound on drum 2x Sennheiser MD 421 Various XLR cable
4x Sanken CU 31-BK Various Speakon Cable
4x Crown PCC160 PZM Various patch cables / accessories
1x Crown PZM
2x Audio-technica ES933C Condenser Cardioid hanging Mic Black 2x Shure Microflex Cardioid Cartridge R185B (black) mic 2x Shure Microflex Gooseneck MX412/N
Radio Mics - with fixed site licence: Pianos:
4x Sennheiser – EM 300 G3 True Diversity Receiver Steinway D3 Concert Grand 9ft
4x Sennheiser – SK 300 G3 Bodypack Transmitter Knight K5 Upright
4x Sennheiser - ME4 Clip-on Microphone, condenser, cardioids 4x Sennheiser – SKM 300-835 G3-C-X Handheld Transmitter
page 18
Stage Power Distribution
Main stage supply: Locate Down Stage Left Supply Fed to an MEM Switch Fuse, Main isolator, HRC BS88 100A This is tailed into a container switched interlocked safety socket 63A 3P + N + E, 100A, 400V, 100A MCB type D 30mA RCD
Sound Supply: Located Down Stage Right
Container switched interlocked safety socket 32A 2P + E, 230V (Fed from control room distribution board)
Other Supplies: Located Down Stage Right
Feed is from a 50A triple pole MCB below stage Supply is split into 2x Container switched interlocked safety socket 32A 3P + N + E, 20A 30mA RCD protected
Motor Supply: Located on the Fly Floor (Feed from DB111)
Supply Fed to an MEM Switch Fuse, Isolator, socket 16A 3P + E
Sound Power: On stage clean supply - 32A ring-main, 13A socket outlets around the main house
page 19
Rigging and Staging Equipment
Masking:
1x Shark Tooth Black Gauze 18ft by 40ft
1x Shark Tooth White Gauze 6m by 12m
1x Full Blacks 11m by 7m
1x Full Blacks 12m by 5.5m
2x Half Blacks 6m by 7m
5x Borders 13m by 3m
2x Short Borders 13m by 0.6m
3x Legs 2m by 7m (pairs)
2x Legs 3m by 7m (pairs)
1x Cyclorama White
Rigging:
6x 1m Steel wire rope slings black (0.5T)
6x 2m Steel wire rope slings black (0.5T)
5x 2m Steel wire rope slings silver (0.5T)
6x 3m Steel wire rope slings black (0.5T)
12x 4m Steel wire rope slings black (0.5T)
4x 4m Steel wire rope slings silver (0.5T)
17x 1m Polyester endless slings
8x 2m Polyester endless slings
11x 3m Polyester endless slings
12x Single leg chain sling, hook to hook with Clutch 1500kg
Selection of Bow shackles, hanging irons and other rigging equipment available.
Steel Deck: Other Stage Accessories:
17 x Steel Deck 8 by 4 14 x Steel Deck 6 by 4 35x Stage weight 12kg
1x Steel Deck 5 by 4 8x Stage Brace Long
4x Steel Deck 8 by 2 12x Stage Brace Medium
2x Steel Deck 6 by 2 11x Stage Brace Small
3x Steel Deck 4 by 4 21x 20mm Metal Conduit 3m
6x Lite Deck Triangular staging 3x Pro site 110V flood lights 1x 110V transformer
Steel Deck Hand Rails 3x Dollies including 1 piano dolly
Various sizes of scaffold legs Various scaffold clamps and wheels
Access Equipment:
Genie awp 36 access platform Large A-Frame ladder
Zarges - 3-part 12 rung ladder
Zarges - 8 step A-frame
Zarges - 5 step A-frame
Tallescope 50518 standard: Max H 5.9m and Min H 3.9m
page 20
Main Auditorium Seating
Stage Format Capacities
End stage: 477
End stage with orchestra pit / forestage: 441
Mega - thrust: 367
Thrust: 423
Thrust with forestage: 393
Catwalk: 441
Theatre in the round: 451
Stalls: Tier 1: Tier 2:
Total: 288 Total: 110 Total: 79
Stalls: 184 Forward facing: 60 Forward facing: 31
Back of Stalls: 60 Side seats: 46 Side seats: 44
Side seats: 44 Box A and B: 4 Box C and D: 4
Rows A and B: 36
Row L 8
Wheel chair spaces: 4
Dressing room & performance space capacities
Dressing Rooms: Main Stage: Cellar: Attic:
1: = 6 persons Standing: 100 Standing: 150 Standing: 60
2: = 4 persons Seated: 120
3: = 1 persons
4: = 15 persons
5: = 14 persons
6: = 4 persons
Stage Floor
The stage is sprung maple with 6mm MDF covering painted black.
page 21
Auditorium Measurements
Auditorium (all line-of-sight distances on centre line)
Fixed stage edge to centre stalls tier front rail 11.47m
Fixed stage edge to middle tier front rail 12.00m
Fixed stage edge to top tier front rail 13.00m
Width between balconies 11.30m
Height front row of stalls to underside of central bridge 7.90m
Height front row stalls to stage floor 1.07m
Front lx bar on bridge to stage floor 7.03m
Nominal volume of auditorium 2,830m2
Nominal volume of auditorium and stage 5,055m2
Elevators
Four elevators allow alternative stage formats.
Orchestra pit / forestage, thrust and mega-thrust.
Orchestra pit, total area 39.75m2 (gross)
Area in open 20.70m2 (gross)
Area beneath stage overhangs 19.04m2 (gross)
Orchestra rail to stage edge 1.82m
Stage edge to rear wall of orchestra pit 1.69m
Max depth of elevator below stage 3.30m
Max depth of rear pit fixed floor 2.55m
Thrust stage (central elevator plus bridge):
Front of thrust to fixed stage edge 5.60m
Width of thrust 5.60m
Get-in
Tailboard height above road in private car park into scene store: Width 2.83m
Height 1.23m
Scene store off stage-left rectangular area: 35.0m2 (gross)
Access width 3.20m
Height 4.30m
page 22
Cellar Production Lighting Information
Lighting Desk: ChamSys and PC wing
Llyama ProLite touch screen manitor
Dimmers: 4 x 6 channel Anytronics dimmer pack (32A 3phase)
(The first 5 channels are used for House Lights)
House Lights: 20 x Parcan 56 (Chome)
Control Area: Control area is by the main entrance into the space
Cellar Production Sound Information
Cellar PA: 2 x EAW Linear Activation LA325 Speaker
2 x EAW Linear Activation LA400 Speaker
1 x Dbx Driver Rack PA
2 x Yamaha P3200 amps
2 x C Audio 600 Power amp
Mixing: Yamaha Mg166 Cx16
Playback: Tascam MD-350 Mini Disk Player
Sony Compact Disk CDP-D11
Outboard: Behringer Multicon pro – XL MDX 4600 Compressor
/ Limiter
Yamaha SPX1000 Reverb Unit
page 23
page 24
page 25