Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
MLL022_05
TECHNICAL SPECIFICATION:
Pollution Degree
Frequency
Function
Cat. No.:
Power Consumption
Asymmetry
On Delay
Setting Accuracy
Trip Levels
Setting Accuracy±10% of Full scale Off Delay
Reference Supply Voltage ( )
MD71BF
Phase and Voltage Control
MG73B9
Type II
4 VA (Max.)
5 s fixed 0 - 15 min
MG73BH
5 s fixed
10% 20% ± 4%,
Hyst. 4%±2%)
Contact Arrangement
Phase Asymmetry
Phase Reverse
UV (RED)
OV (RED)
ON (Green)
Indications or Status of LED
Degree of Protection
36 x 60 x 90
95% (Rh)
-25 C to +70 C
-15 C to +55 C
5 1 x 10 Operations
6 3 x 10 Operations
Ag Alloy
5 A (Res.) @ 250 VAC / 28 VDC
Mechanical Life Expectancy
Relay Output
Electrical Life Expectancy
Operating Temperature
Storage Temperature
Housing Flame Retardant UL 94-V0
Humidity (Non-Condensing)
Contact Material
Contact Rating
Certifications
Max. Operating Altitude
Weight (Unpacked)
Dimensions in mm (W x Hx D)
CE, RoHS
2000 m
120 g Approx.
IP-20 for Terminals ; IP-30 for Housing
1 C/O
240 VAC
47 to 63 Hz
0 - 15 min 0.5 - 15 s
5 s fixed 5 s fixed 5 s fixed0 - 15 s 0.5 - 15 s
0 - 15 s 0.5-10 s ±1s
0 -
MD71B9 MD71BH
N.A.
N.A. Blinking
Continuous ON
Over Voltage
Power ON
Under Voltage
MG73BF MG73BR
173 V ± 10 V
288 V ± 10 V
5 s fixed
N.A.
105% to 125% of
55% to 95% of
+/- 5% of full scale (Voltage setting are with respect to neutral)
Under Voltage
Over Voltage
º º
º º
Mounting Base / Din-Rail (35 mm Symmetrical)
MGH3BH MGI3BF
105% to 125% of
55% to 95% of
220 VAC 230 VAC
5 s fixed 0 - 15 s
0.5 - 15 s 5 s fixed
10%
RoHS
Cat. No.:
MD71B9
MD71BH
MD71BF
MG73B9
MG73BH
MG73BF
MGH3BF
MG73BR
MGH3BH
MGI3BF
MG73BQ
MGH3BY
1-Phase or 3-Phase 4-Wire
Power ON Delay < 500 msec
Phase Reverse trip time is < 100 ms. For Non-Inductive loads Phase Fail trip time is < 100 ms.
.5
.5 - 5s
120/240V 3.0/1.5A
24/125/250V 2.0/0.22/0.1A
Utilization Category Ue Rated Voltage V AC-15 Ie Rated Current I
Utilization Category Ue Rated Voltage V DC-13 Ie Rated Current I
*All LEDs should off incase of Single Phase Loss, 2 Phase Loss & 3 Phase Loss conditions.
2 C/O (Minimum load of 5mA is recommended)
MG73BQ
120 to 240settable
80% of
10 %
Hyst. 2.7 %
of
N.A. Blinking
LED Condition / Faults
ASY / REV (RED)
High Cut OFF
Continuous ON
Continuous ON
Continuous ON
Blinking N.A.
SUPPLY MONITORING DEVICE, SERIES: SM500, 3-PHASE 4-WIRE AND 1-PHASE
MGH3BF
220 VAC 240 VAC
MGH3BY
~500 ms
SUPPLY MONITORING DEVICE
SERIES SM500
1-Phase and 3-Phase 4-Wire
l
l
MG73B9, MG73BH, MG73BF, MG73BR
FUNCTION DESCRIPTION:
MD71B9, MD71BH, MD71BF
MAIN FEATURES:
16 18 26 28
FOR SINGLE PHASE APPLICATION
L1 P L3 N
SM 500
NR
15 25
L2
16 18 26 28
FOR THREE PHASE APPLICATION
L1 P L3 N
SM 500
NR
15 25
L2
Y B
16 18
FOR SINGLE PHASE APPLICATION
L1 P L3 N
SM 500
NR
15
L2
16 18
FOR THREE PHASE APPLICATION
L1 P L3 N
SM 500
NR
15
L2
Y B
90.0
68.0
45.0
60.0
DIN
RA
IL
(35 M
M -
SY
MM
ET
RIC
AL)
36.0
Ø4.2
100.0
C / C
36.0
Ø4.2
100.0
C / C
l Adjustable Reference voltage Monitors own supply Phase Loss & Neutral loss detection. Phase Reverse detection Phase Asymmetry 10% (Phase to Phase) Adjustable Over & Under voltage trip level Adjustable Operate Time & Release Time SPDT, DPDT Relay output (5 A, Resistive) Din rail & base mounting
ILED indications
nstant trip in case of Interruption, Phase Reverse and Phase Loss
l
l
technical specification.
Output Relay will energize after operatetime if following conditions are withinlimit:1. All phases are present and phase voltages are within the over & under voltage trip levels set on the device.
2. If Phase Sequence is ok.
3. If Phase to phase asymmetry is less than value mentioned in
Relay will trip after release time if any of Phase exceeds over voltageand under voltage trip levels.Relay will be trip in
MLL030_03
TECHNICAL SPECIFICATION:
Pollution Degree
Frequency
Function
Cat. No.:
Power Consumption
Asymmetry
Hysteresis
On DelayTime Delay
Setting Accuracy
Trip Levels
Trip time for:
Supply Voltage ( )
Phase, Neutral and Voltage Control
2
10 VA (Max.)
Respective fault condition will be indicated by LED immediately & Relay will be tripped after specified trip time only.
LED Indicationson front plate
Degree of Protection
36 x 90 x 60
95% RH (without condensation)
-10 C to +70 C
-10 C to +60 C
5 1 x 10 Operations
7 1 x 10 Operations
Ag Alloy
5 A (Res.) @ 240 VAC
Mechanical Life Expectancy
Electrical Life Expectancy
Operating Temperature
Storage Temperature
Housing Flame Retardant UL 94-V0
Humidity (Non-Condensing)
Contact Material
Utilization Category AC-15 Rated Voltage(Ue):230V/125V;Rated Current(Ie):1.3 A/2.5A
Contact Rating
Certifications
Max. Operating Altitude
Weight (Unpacked)
Dimensions in mm (W x Hx D)
CE, RoHS
2000 m
120 g Approx.
IP-20 for Terminals ; IP-30 for Housing
Contact Arrangement
Neutral Fail
UV
OV
Asymmetry
Phase reverse
Power ON
Green
ON
ON
ON
ON
ON
ON BLINK BLINK
Phase Fail BLINK OFF OFF OFF
Phase Fail * BLINK ON OFF BLINK
BLINK
OFF ON OFF
ON OFF OFF
OFF
OFF
OFF
OFF
OFF
ON
BLINK
OFF OFF
UV OV Blink: ASY, ON: REV
Relay Output 2 C/O
415 VAC ; 3-Phase 4-Wire
47 to 53 Hz
5 s +/-1 s (fixed)
5sec +/- 1sec (Fixed)
94 V+/-4 V Ph-Ph.
07 V+/-2 V
105% to 125% of
55% to 95% of
+/- 5% of full scale
Under Voltage
Over Voltage
º º
º º
Mounting Base / Din-Rail (35 mm Symmetrical)
The technical information provided in this document is correct at the time of going to the press.Product innovation being a continuous process, we reserve the right to alter specifications without any prior notice.
Note :
SUPPLY MONITORING DEVICE
SERIES SM500
3-Phase 4-Wire
Cat. No.:
RoHS
Terminal Details :
Phase failurePhase to phase ImbalanceUnder voltageOver voltage
Trip time for neutral failure
Product relay will not become on, if the phase sequence is reverse at power on.If the phase sequence is reversed during running condition the product will remain healthy.
500 ms to 1 sec
Utilization Category DC-13 Rated Voltage(Ue):250V/120V/24V;Rated Current(Ie):0.1A/0.22A/2A
MAC04D0100
*Phase fail indications when I/P voltages are below UV set point and below asymmetry
MAC04D0100
Kindly set the potentiometers knobpointers for UV & OV settings, correctly onthe marking lines on front plate. Do not set the pot knob pointers in between the markings. This is to ensure the correct tripping voltage values with respect to the set value.
Caution!
Phase, Neutral and Voltage Control
380 VAC ; 3-Phase 4-Wire
MAC04D0119
MAC04D0119
SUPPLY MONITORING DEVICE
SERIES SM500
3-Phase 4-Wire
FUNCTION DESCRIPTION:
MAIN FEATURES:
Automatic recovery on fault removal.
l Monitors own supplyl Phase loss (failure) detection. l Neutral loss detection.l Phase reverse detection.l Phase asymmetry.l Adjustable Over & Under voltage trip levell Fixed Operate Time & Release Time Delayl 2 C/O Relay output (5 A, Resistive)l Din rail & base mountingl LED indication for all failure conditions.l
l
technical specification. Relay will trip after the release time, if any of the above condition fails.
Output Relay will energize after operatetime if following conditions are satisfied:
1. All phases are present and phase voltages are within the over & under voltage trip levels set on the device.
2. Neutral is present.
3. Phase Sequence is ok.
4. Phase to phase asymmetry is less than value mentioned in
In case of balanced load condition, if neutral is open, virtual neutral is formed at the star point, hence the product will not trip & remain healthy.
16 18 26 28
FOR THREE PHASE FOUR WIRE APPLICATION
L1 L3 N
SM 500
NR
15 25
L2
Y B
MLL030_03
Connetion Details :
l
l
l
MAC04D0100 : 415 VAC PH-PH
Ref. Voltage
MAC04D0119 : 380 VAC PH-PH
CERTIFICATION :
CISPR 14-1 Ed. 5.0 (2005-11) Class A
IEC 60068-2-6 Ed. 7.0 ( 2007-12) 5 g
>50 k
90.0
68.0
45.0
60.0
DIN
RA
IL
(35 M
M -
SY
MM
ET
RIC
AL)
36.0
Ø4.2
100.0
C / C
OVERALL & MOUNTING DIMENSIONS (in mm) FRONT FACIA :
MAC04D0100
MAC04D0119
380 Un