4
PENDULUM TESTING MACHINE equipments TechnofinE The Testing Technology Excellence

TechnofinE equipments...B Specimen setting and centering long for Charpy test (Useful particularly for carrying out tests at sub zero temp.) B Gauge for checking distance of specimen

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TechnofinE equipments...B Specimen setting and centering long for Charpy test (Useful particularly for carrying out tests at sub zero temp.) B Gauge for checking distance of specimen

PENDULUM

TESTING MACHINE

e q u i p m e n t s TechnofinE

The Testing Technology Excellence

Page 2: TechnofinE equipments...B Specimen setting and centering long for Charpy test (Useful particularly for carrying out tests at sub zero temp.) B Gauge for checking distance of specimen

FEATURES

B For Charpy, Izod Tests for various meterials

B Model TFIT is as per IS3766-1977, IS1598-1977, IS1757-1988, IS1499-1977

and BS 131 Part I,II,III,IV

B Model TFIT-300-EN & TFIT-300-D Confirms to IS, BS Standards as above & also

confirms to BS EN 10045-1983 (For Charpy)

B Works on Pendulum Principle, Difference between height of drop of Pendulum

before Rupture & Height of rise after Rupture of specimen is directly proportional to

impact energy absorbed.

B Direct indication of impact energy abosrbed by specimen on large dial for TFIT-300-N,

TFIT-300-EN.

B Safety guard for the Pendulum.

STANDARD ACCESSORIES

B Charpy Striker - 1 No.

B Izod Striker - 1 No.

B Charpy Izod Support Block - 1 No.

B Specimen Setting Gauges - 2 Nos.

B Set of Spanners - 1 Set

OPTIONAL ACCESSORIES B Specimen setting and centering long for Charpy test

(Useful particularly for carrying out tests at sub zero temp.)

B Gauge for checking distance of specimen notch from both ends for charpy and Izod

test specimen. (One guage for Charpy and one gauge for Izod).

B Specimen clamps for Izod specimen

B Gauge for checking std. 'U' notch on specimen.

B Gauge for checking std. 'V' notch on specimen.

B Gauge for checking depth below the std. 'U' notch on specimen.

B Gauge for checking depth below the std. 'V' notch on specimen.

B Template for checking cross section of 10 x 10 mm for Izod/Charpy square

test specimen.

B 'U' notch milling cutter.

B 'V' notch milling cutter.

B Subzero Temperature bath with digital calibrated temperature indicatore.

B Dry ice making unit

B Lateral expansion gauge.

-300-N

ANALOGUE

IMPACT TESTING MACHINE

Page 3: TechnofinE equipments...B Specimen setting and centering long for Charpy test (Useful particularly for carrying out tests at sub zero temp.) B Gauge for checking distance of specimen

SALIENT FEATURES B Direct indication of impact energy abosrbed by specimen onDigital Display B 21x8 Lines LCD Graphics Display with Backlit B Data entry for Serial No., Batch No., No. of readings for Average, Date & Time B Battery Backup Real Time Clock for Test results time stamp B Results are displayed in BIG Fontsize B For average option, upto 9 previous results are displayed on screen, Average and

standard deviation values are displayed after completion of test. B 500 Results are stored in the system with automatic result data entry in storage. B User can enable auto save result storage in system or disable it. B Batch wise reports and stastical reports are displayed on Screen and printed on printer B At a time user can see 7 readings on LCD display & he can scroll with UP/DOWN keys B Serial Port for Dot Matrix Printer or Thermal Printer interface B Print result consists of Batch No, Serial No. Date Time, Impact Energy & Unit B RS232C Port can be programmable, Baud rate can be selected B Digital Measuring and control technology comes as standard with the hardness

testing machines that enables test sequence parameters to be reported with a high level of precision.

FEATURES B For Charpy, Izod Tests for various meterials

B Strictly confirms to ASTM-E-23- current Standard

B Works on Pendulum Principle, Difference between height of drop of Pendulum before

Rupture & Height of rise aftr Rupture of specimen is directly proportional to impact energy

absorbed by specimen on large dial./Digital readout.

B Two hand pendulum release operation for operator for operator safety.

B Large safety guards on both sides of pendulum.

B NIST approval of machine with samples from NIST, USA can be arranged.

B Motorised with higher capacity impact machine is also available.

STANDARD ACCESSORIES B Charpy Striker - 1 No.

B Charpy Support Block - 1 No.

B Specimen Setting Gauge (for Charpy) - 1 No.

B Set of Spanners - 1 Set

B Foundation Bracket - 1 No.

OPTIONAL ACCESSORIES B Self Centering tong for Charpy Test Specimen (useful particularly for carrying out tests at

sub zero temp)

B Sub zero temp. bath with digital calibrated temperature indicator.

B GO-NO-GO, Gauges for specimens confirming following parameters within specified limits

1. Centre line of notch from both ends 2. Angle of V notch

3. Depth below standard V notch 4. Cross section of 10x10 mm specimen.

B Milling cutter for V notch

B Lateral Expansion gauge as per ASTM-E-23

B Standard Impact specimen for verification of machine from NIST, USA

(we also undertake calibration of machines of any make, as per ASTM-E-23 including

approval from NIST, USA)

ASTM Charpy Impact Testing Machine TFIT-300-ASTM

DIGITAL IMPACT TESTING MACHINE TFIT- 300-D & TFIT-300-ASTM-D

Page 4: TechnofinE equipments...B Specimen setting and centering long for Charpy test (Useful particularly for carrying out tests at sub zero temp.) B Gauge for checking distance of specimen

Description

Pendulum Drop Angle (Degree)

Pendulum Effective Weight (Kg.)

Striking velocity of Pendulum (m/Sec)

Pendulum Impact Energy (Joules)

Min. Scale Graduation (Joules)

(Only for FIT-300-D)

Distance between axis of Pendulum to centre of strike (length of pendulum in mm)

Max. total friction & windage losses.

Striking edge

a. Angle (Degree

b. Radious of curvaturer (mm)

c. Width at tip (mm)

d. Horizontal relief (Degree)

e. Vertical relief (Degree)

Specimen Anvils and supports

a. Suitable for max. specimen cross section (mm)

b. Distance between specimen Anvils (mm)

c. Included angle of Anvil tip (Degree)

d. Radius of curvature at Anvil tip. (mm)

Over all size (mm) (approx)

Net Weight (kg) (approx)

We can also supply UTM, Compression, Tensile, Torsion, Fatgue Machines and Hardness Testers & Customer Built Testing Machines 'Technofine' reserves the right to change above specification without any notice due to constant improvements in design.

CHARPY

140

21.300

5.308

300

2

0.5

813.5

0.5% of Max. Impact Energy

30

2

18

----

----

10x10

40

79

1

FIT-300-N,FIT-300-EN,FIT-300-D

IZOD

90

21.300

3.984

170

2

0.5

813.5

0.5% of Max. Impact Energy

70

0.7

10

5

FIT-300-N-ASTM FIT-14 FIT-4.2

IZOD

120

4.665

2.44

14

0.1

----

204

0.5% of Max. Impact Energy

---

3.2

----

----

----

12.7x12.7

---

---

---

CHARPY

140

22.350

5.18

300

2

---

775

0.75% of Max. Impact Energy

30

8

4

---

---

10x10

40

80

1

IZOD

120

1.40

2.45

4.2

0.05

----

204

0.5% of Max. Impact Energy

---

3.2

---

---

---

12.7x12.7

---

---

---

Model

For Model FIT-300-N:300 For Model FIT-300-EN:450 For Model FIT-300-D: 450

760(L)x440(W)x1925(H)

935 (L) x430 (W)x2070 (H)

500

500 (L) x 250 (W) x 625 (H)

45 45

---

---

---

10x10

---

TECHNICAL SPECIFICATIONS

2, Nilkanthnagar, Sangli - Haripur road, Haripur, Tal. Miraj, Dist. Sangli, M.S., INDIA, Email: [email protected] / [email protected]

TechnofinE e q u i p m e n t s MFGR. OF MATERIAL TESTING MACHINEB Computerised Universal Testing Machine B Computerised Hardness Testing Machine B All Types of Testing Machines

We reserve the rights to change the abobe specifications without any notice.

Authorised Channel Partner