18
Technologies for Assessing the Condition of Water Mains NC AWWA Spring Conference 2014 Matt Shultz, PE - HDR

Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Embed Size (px)

Citation preview

Page 1: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Technologies for Assessing the Condition of Water Mains NC AWWA Spring Conference 2014 Matt Shultz, PE - HDR

Page 2: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Condition Assessment

•  Determining and documenting the physical state of infrastructure at a point in time

•  Identify improvements to extend asset life •  Prioritizing improvements

Page 3: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Aging Infrastructure is the driver for Condition Assessment and Renewal

Reference: AWWA, Buried No Longer: Confronting America’s Water Infrastructure Challenge, 2012

Page 4: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Water Main Failures Can Cause Problems

Photo: Bill O’Leary, Washington Post

Page 5: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

….and have Consequences

Photo: Al Seib, LA Times

Page 6: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Three Components of Condition Assessment Determine Success and Usefulness

Page 7: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Assessment Technologies…there are a lot of them

Source: EPA, 2012 Condition Assessment Technologies for Water Transmission and Distribution Systems

Page 8: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Ductile and Cast Iron Pipe…aging is a problem

Aging can occur from: •  Internal corrosion •  External corrosion •  Fatigue Failure Methods: •  Pits or rust holes •  Bursts (longitudinal) •  Breaks (circumferential) •  Leaks at joints or service taps

Pitting Corrosion

General Corrosion

Page 9: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Aging is a problem…but not always the answer

The Evolution of Iron Pipe is Dominated by Reduction in Wall Thickness

1928 Class D CI

1.58” 1952

Class 150 CI 1.22” 1957

Class 27 CI 0.94”

1957 Class 22 CI

0.87” 1965 Class 3 DI

0.58” 1976

Class 50 DI 0.43”

1991 Class 150 DI

0.38”

EXAMPLE FOR MINIMUM WALL 36-INCH IRON PIPE

Page 10: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

External Corrosion…corrosive soils

Soil and Water Analysis •  Resistivity, pH, Sulfate, Chloride, Redox Potential, Etc.

–  DIPRA 10-Point (AWWA C105) •  Linear Polarisation Resistance

Page 11: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

External Corrosion… stray currents

ANODEGROUND BED

+

CATHODICALLY PROTECTEDSECTION OF PIPELINE A

-

POSITIVE DC CURRENT FLOW PIPELINE A

PIPELINE B

RECTIFIER

ACCELERATED CORROSIONON PIPELINE A

Overhead Power Transit Systems

Other Utilities

Page 12: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Ductile and Cast Iron – Assessment Technologies

Electromagnetic: Remote Field Eddy Current •  PICA’s See Snake •  Provides end to end 360-deg evaluation •  Accurate determines pit size, depth, and location •  Provides general corrosion loss •  2” to 36” pipes, tools match pipe size •  Free swimming or tethered •  Waterline can remain in service •  Can navigate through bends

Page 13: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Design - PCCP Standards Changed Over Time …and not always for the better

Page 14: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Assessment Technology - PCCP Water Mains

Page 15: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Acoustic Events/Wire Breaks Leading up to SDCWA Failure

Page 16: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Asbestos Cement Pipe

Deterioration can occur from: •  Soft Water Corrosion •  Acidic Corrosion (low pH water) •  Sulfate Corrosion •  H2S Corrosion Failure Methods: •  Bursts (longitudinal) •  Breaks (circumferential)

Page 17: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

AC Pipe: Acoustic Velocity Thickness

A comparison by Sweetwater Water Authority (CA) was promising

Page 18: Technologies for Assessing the Condition of Water Mains · – DIPRA 10-Point (AWWA C105) ... tools match pipe size ... Technologies for Assessing the Condition of Water Mains

Technologies for Assessing the Condition of Water Mains NC AWWA Spring Conference 2014 Matt Shultz, PE - HDR