Heat pumps with freshwater technology THE POWER FAMILY www.idm-energie.com Technical documentation Installation instructions TERRA CL 8-33 HGL/BA (P) (400V) with Navigator ® 1.0 Control 812215 Rev.14 - Translation of original insturction

TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

  • Upload
    doduong

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

Heat pumps with freshwater technology

T H E P O WE R FA M I LYw w w . i d m - e n e r g i e . c o m

Te c h n i c a l d o c u m e n t a t i o nI n s t a l l a t i o n i n s t r u c t i o n s

T E R R A C L 8 - 3 3 H G L / B A ( P ) ( 4 0 0 V )

w i t h N a v i g a t o r ® 1 . 0 C o n t r o l

8122

15 R

ev.1

4 - T

rans

latio

n of

orig

inal

inst

urct

ion

Page 2: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

2. Allgemeine Beschreibung

Installation instruction TERRA CL2

1

2

3

4

5

6

7

8

9

10

11

12

13

Contents

Contents

1. DESCRIPTION 41.1. General Information 41.2. Description 51.3. Application range 51.4. Scope of delivery 51.5. Protection of the environment 5

2. TECHNICAL DATA 6

3. DESIGN 7

4. DIMENSIONS 104.1. Heat Pump CL 104.1.1. Cable bushing TERRA CL HGL 114.1.2. Cable bushing TERRA CL BA 114.2. Control cabinet 124.3. Intake box (optional accessories) 12

5. INTERIOR INSTALLATION 145.1. Installation Instructions 145.2. Heating Connection 145.3. Condensation run-off 145.4. Air Routing 145.5. Air Inlet and Outlet 145.6. Noise 155.7. Noise expansion 155.8. Decoupling of buildings 165.9. Installation space 165.10. Corner installation 175.10.1. Space Required and Accessibility 175.10.2. Customer preparation 185.10.3. Accessories for corner installation 195.10.4. Assembly Instructions - Corner Installation 195.11. Installation – Standard air duct 205.11.1. Accessories – Standard air duct 215.11.2. Customer preparation – Option 1 225.11.3. Customer preparation – Option 2 235.11.4. Assembly instructions - Standard duct 245.12. Installation – Flexible air hose 255.12.1. Customer preparation – Flexible air hose 265.12.2. Accessories – Flexible air hose 275.12.3. Assembly instructions – Flexible air hose 285.13. Flexible air hose with air intake box 295.14. Conversion from left to right-side connection 30

6. EXTERIOR INSTALLATION 326.1. Customer preparation 326.2. Distances 33

Page 3: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 3

1

2

3

4

5

6

7

8

9

10

11

12

13

Contents

Cont

ents

General instructions on operating the heat pump.

Important instructions on assembling and operating the heat pump. It is imperative that these are observed.

General instructions on assembling the heat pump.

Space for customer servicetelephone number

6.3. Accessories – Exterior installation 33

7. HEATING SIDE CONNECTION 347.1. Requirement heating side connection 347.2. TERRA CL HGL heat pump with IDM Hygienik with separation plate 357.3. TERRA CL HGL heat pump with IDM Hygienik and heating buff er 367.4. TERRA CL BA heat pump with Hygienik and separation plate 377.5. TERRA CL BA heat pump with Hygienik and without separation plate and heating buff er 387.6. TERRA CL BA oil/gas boiler, Hygienik with separation plate and heating buff er 397.7. TERRA CL HGL-P with process reversal for cooling and Hygienik with separation plate 407.8. TERRA CL BA-P with process reversal for cooling and Hygienik with separation plate 41

8. ELECTRICAL CONNECTION 428.1. Power supply 428.2. Connection Diagram Electrical Components 438.3. Power Supply Connection 448.4. Connection lines control cabinet - heat pump 448.5. EMC 458.6. Layout of the Inputs on the Central Unit 468.7. Sensor design 468.7.1. Sensor equipment 468.7.2. Flow temperature sensor 468.8. Impulse Inputs 468.9. Layout Digital Inputs 468.10. Layout Outputs 478.10.1. Analogue Outputs (80-87) 478.10.2. Triac outputs (10-12) 478.10.3. Digital outputs 230V AC (20 -38): 478.11. Actuation of the changeover valve on the heat source side at direct cooling 478.12. Actuation of the changeover valve on the heat source side at process reversal 488.13. Connection of the mixers 488.14. System Earthing 488.15. Maximum Restriction for Underfl oor Heating 488.16. Composite signal zone valves 488.17. Connection external preselected target value 0-10V 48

9. COMMISSIONING 509.1. Commissioning information 509.1.1. First switch-on of the heat pump 509.1.2. Operation 509.2. Malfunctions 50

All rights reserved for modifi cations to the technology and design.

Page 4: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

1. Allgemeine Beschreibung

Installation instruction TERRA CL4

1

2

3

4

5

6

7

8

9

10

11

12

13

1

Description

1. Description

1.1. General I nformation

By purchasing this system you have acquired a modern and effi cient heating system. Ongoing qua-lity controls and improvements as well as functional checks at the plant guarantee you technically perfect equipment.

Please read through this documentation carefully. It contains important information for correct installation and safe and economical operation of the system.

Safety instructions:Installation and maintenance work can be hazardous due to high system pressure, high temperatures and live parts and may only be operated by specialist staff. Heat pumps may only be installed by competent spe-cialist staff and commissioned by a customer service company trained to do so by IDM-Energiesysteme GmbH. When working on the heat pump, the system must be deactivated and secured against reactivation. In addition, all safety instructions in the relevant do-cumentation, stickers on the heat pump itself and all other applicable safety regulations must be observed.

Transport:During transport, the heat pump must never be inclined more than 30°. The heat pump must not be transported on the connection fi ttings. The transport packaging may only be removed if the heat pump is located at its installation location.

Sound emission:TERRA heat pumps are very quiet in operation thanks to their design. It is however important that the site of the heater is situated as far as possible from noise-sensitive living areas. A noise-insulating door should be fi tted door.

Construction drying and screed heatingThe heat pump is not designed for the increased heat requirements when drying out construction work or heating plaster or screed. This must be covered by equipment to be provided by the customer if required.

Servicing and maintenance:Regular maintenance as well as checking and servi-cing of all system components guarantee its safe and economical operation in the long term. To achieve this, we recommend a maintenance contract with the relevant customer service company.

Cleaning:If necessary, the TERRA heat pump can be cleaned with a damp cloth. The use of cleaning agents is not recommended.The fi ns of the heatexchanger package must be cleaned if required (e.g. leaves can block the air fl ow).

Installing additional components:The installation of additional components which have not been tested with the equipment may impair function. No liability is accepted and the guarantee becomes void in the event of damage caused for this reason.

Standards and directives:

Note for the installation of the heatpump follow all eff ective national and inter-national piping- and installation rules same as rules for accident prevention and safety regulations when installing pipeline systems and electrical components and equipment as well as the instructions of this Installation instruction.

Thereto belongs among other things:

- the general effective rules for accident prevention and safety regulations

- the regulations for environmental protection - the provisions/regulations of the professional asso-ciations.

- the effective laws, standards, guidelines and regu-lations e.g. DIN,EN,DVGW,VDI and VDE

- regulations of the local suppliers/supply companies

Page 5: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 5

1

2

3

4

5

6

7

8

9

10

11

12

13

1

Allgemeine Beschreibung

Des

crip

tion

1 .2 . Descr ipt ion

The TERRA CL is an air-water heat pump with suction gas cooled scroll compressor with large multi-row Al/Cu fi nned evaporator. A special speed-controlled radial fan means that large fl ow rates can be achieved at low speeds.A plate heat exchanger is used as the condenser. The machine frame consists of a steel-reinforced plastic profi le. The cover panels are foam-insulated. This means that the casing is completely protected from cold bridges and has excellent sound insulation.

The heating controller is a modern controller that ful-fi ls all the functions of standard heating regulation.

The heat pump has a compact design, the evaporator is ready-fi tted in the top of the heat pump casing. The heat pump is fi lled with refrigerant and is checked in the factory before shipping for reliable functioning.

1.3 . Appl icat ion range

For monovalent heating and cooling of detached and semi-detached houses under appropriate environ-mental conditions. The building must be equipped with low-temperature heating (e.g. underfl oor heating, wall heating, low-temperature radiator heating).

TERRA CL heat pumps work using the R407C safety refrigerant which, when correctly mounted and com-missioned, circulates in a closed circuit. This minimis-es its environmental impact.

1.4 . Scope of del iver y

- Heat pump unit with suction gas cooled scroll compressor

- Stainless steel plate heat exchanger as condenser - Finned tube Al/Cu evaporator package - Speed-controlled radial fan - Starting current limiter with rotary fi eld monitoring

- Refrigerant collector and dryer - Thermostatic expansion valve - Refrigerant inspection glass - Refrigerant heat exchanger - pressure controller for high and low pressure moni-toring

- Integrated switching valve for defrosting - Switch cabinet with integrated regulation - Defrost regulator - Inlet air sensor - Thermal relay to protect the compressor - Thermally insulated basic frame - Cladding, insulated against heat and noise - Electric heating immerser for any re-heating required (6 kW integrated in TERRA CL 8-15, for TERRA CL 20-33 a 9 kW heating immerser is avail-able as accessories)

- fl exible connection hoses

HGL heat pumps

- Built-in HGL valve - Stainless steel plate heat exchanger as HGL exchanger

Other accessories:see also the IDM pricing list

1.5 . Protec t ion of the environment

The lower the maximum fl ow temperature is set, the higher the effi ciency of the heat pump.

Heatpumps are electrical equipment made from high valuable materials, which are not allowed to be disposed like normal household garbage, but have to be disposed professional and proper according the regulations of the local authorities.

A non-proper disposal can cause, apart from sanctions for the violator, environ-mental damages and harm for your health.

The charging pump is integrated in TERRA CL 8-15 HJGL/BA, loosely suplied with the TERRA CL 20-33 HGL and available as aces-sories for TERRA CL 20-33 BA!

Page 6: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

2. Allgemeine Beschreibung

Installation instruction TERRA CL6

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

Technical data

2. Technical data according to EN 14511 Typ Unit 8 10 12 15 20 TWIN 25 TWIN 30 TWIN 33

Heat output for A2/W35 [kW] 8,6 10,4 12,3 15,2 20,1 23,1 29,0 32,6

Heat output for A7/W35 [kW] 11,1 13,6 16,0 18,9 23,8 26,7 33,3 39,2

Heat output for A-7/W35 [kW] 7,3 8,8 10,4 12,2 17,2 19,9 24,0 28,0

Power consumption A2/W35 [kW] 2,44 2,97 3,57 4,47 5,52 6,69 8,17 9,59

Power consumption A7/W35 [kW] 2,59 3,24 3,85 4,49 6,07 7,01 8,48 9,80

Power consumption A-7/W35 [kW] 2,37 2,84 3,53 3,94 5,61 6,48 7,97 9,33

COP for A7/W35 4,3 4,2 4,2 4,2 3,9 3,8 3,9 4

COP for A2/W35 3,5 3,5 3,5 3,4 3,6 3,5 3,5 3,4

Cooling output for A35/W7 [kW] 7,2 8,4 10,4 12,2 16,8 20,8 24,4 --

Cooling output for A35/W18 [kW] 9,8 11,5 14,4 16,8 23,0 28,8 33,6 --

Power consumption A35/W7 [kW] 3,10 3,80 4,50 5,50 7,60 9,00 11,00 --

Power consumption fo A35/W18 [kW] 3,60 4,40 5,30 6,70 8,80 10,60 13,40 --

EER for A35/W7 2,3 2,2 2,3 2,2 2,2 2,3 2,2 --

Weight HGL/Basic [kg] 254/240 269/255 413/395 468/450 488/470 498/480

Dimensions HxBxT [cm]

153x110x75

153x110x75

173x120x88

193x130x98

193x130x98

193x130x98

Condenser copper-soldered stainless steel plate heat exchanger

Radiator fl ow and return pipe R1“ AG R1“ AG R1“ AG R1“ AG R 1¼“ AG R 1 ½“ AG R 1 ½“ AG R 1 ½“ AG

max. fl ow temperature [°C] 55 55 55 55 55 55 55 55

max. operational pressure [bar] 3 3 3 3 3 3 3 3

min. heating circuit water volume [l/h] 1500 1800 2200 2650 3550 4200 5250 5650

Pressure loss - heating side [kPa] 10 11 15 17 15 16 17 18

Recommended or installed storage tank charging pump (Grundfos / Wilo)

UPS 25-60 EAS 35/6

UPS 25-60 EAS 25/6

UPS 25/80

UPS 25-80

TOP S 30/7

TOP S 30/7

TOP S 30/10

TOP S 30/10

for Terra CL-BA not embodied in the delivery

Remaining pressure of loading pump (standard pump)

[kPa] 35 30 52 46 40 32 70 62

Installed or recommented electric immersion heater

[kW] 6 6 6 6 9 9 9 9

not embodied in the delivery

Condensation run-off R1“ AG R1“ AG R1“ AG R1“ AG R1“ AG R1“ AG R1“ AG R1“ AG

Compressor stages 1 1 1 1 2 2 2 1

Fan type radial / RPM-regulated

Nominal air volume [m³/h] 3500 4000 4500 5500 7000 8100 9500 10000

Externally available compression [Pa] 70 30 100 90 200 250 200 200

Refrigerant R407C

Filling quantity CL [kg] 4 4,2 6 6,1 8,5 10,3 10,5 10,5

Minimum dimension of site CL [m³] 12,9 13,6 19,4 19,7 27,4 33,2 33,9 33,9

Filling quantity CL (P) (reversibel)

[kg] 7,9 8 9,9 10,5 11,3 12,5 13 14

Minimum dimension of site CL (P) [m³] 25,5 25,8 31,9 33,9 36,5 40,3 41,9 45,2

Electrical connection [V] 3x400V / 50Hz

Operating current (compressor+fan) [A] 8,4 9,8 11,1 12,8 19,2 23 26,4 29,2

starting current [A] 18,6 22,1 26,25 34,8 31,2 38,15 43,8 66,7

Upstream fuse primary current [A] 13 13 13 16 20 25 32 32

Upstream fuse control current [A] 13 13 13 13 13 13 13 13

Upstream fuse electric heating element

[A] 13 13 13 13 - - - -

Accustic power level of

duct inlet [dB(A)] 61 62 64 65 72 76 79 81

duct outlet [dB(A)] 51 52 56 57 62 65 68 69

internal unit [dB(A)] 54 55 61 62 66 70 73 75

Page 7: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 7

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

CL 08

CL 10

CL 12

CL 15

CL 33

CL 20

CL 25

CL 30

0,0

5,0

15,0

25,0

35,0

45,0

-20 -15 -10 -5 0 5 10 15 20

35 EN145135 EN1451

{{outside temperature [°C]

heat

ing

capa

city

[kW

]

bivalence point of the particular heatpump type

standard external temperature

electr. additional heatingat TERRA CL 15

service water required

electr. additional heatingat TERRA CL 20

building- characteristic line

required heating capacity atstandard external temperatureincl. service water required

Des

ign

3. Design

The dimensioning of an air/water heat pump should be such that the bivalence point is between -3 and -10 °C. This will help ensure that more than 90° of the annual heating requirement is covered by the heat pump.

The maximum heating output of a building is deter-mined in the design, including its water consumption requirement.

In addition, the standard outside temperature is required. This is determined by geographical location and can be obtained from various institutions.

Example:Single-family house in Germany4 persons

Service water requirement: 4 x 0.25 kW = 1 kWHeating output requirement: 16 kWStandard - outside temperature Germany: - 16 °COff-period factor: 1.1

Heating output required:

(Service water consumption required + heating output required) x off-period factor = 18.7 kW

Page 8: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

3. Allgemeine Beschreibung

Installation instruction TERRA CL8

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

CL 08

CL 10CL 12

CL 15

CL 33

CL 20

CL 25

CL 30

0,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

-20 -15 -10 -5 0 5 10 15 20

W35 EN1451135 EN14535 EN145

Outside temperature [°C]

Hea

tin

g c

apac

ity

[kW

]

0,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

-20 -15 -10 -5 0 5 10 15 20

CL 08

CL 10

CL 12CL 15

CL 33

CL 20

CL 25

CL 30W45 EN1451145 EN14545 EN145

Outside temperature [°C]

He

atin

g c

apac

ity

[kW

]

Design

Design

Performance charts

Page 9: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 9

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

0,0

5,0

10,0

15,0

20,0

25,0

30,0

35,0

40,0

45,0

-20 -15 -10 -5 0 5 10 15 20

CL 08

CL 10

CL 12CL 15

CL 33

CL 20

CL 25

CL 30W55 EN1451155 EN14555 EN145

Hea

tin

g c

apac

ity

[kW

]

Outside temperature [°C]

-20 -15 -10 -5 0 5 10 15 20 25 30 35

20

25

30

35

40

45

50

55

60

10

[°C]

[°C]

R407c

Outside temperature

flow

tem

pera

ture

TERRA CL - Heating

0 5 10 15 20 25 30 35 40 45 50

4

6

8

10

12

14

16

18

20

2

[°C]

[°C]

R407c

0

outside temperatur

flow

tem

pera

tur

TERRA CL - Cooling

Design

Des

ign

Application range

Page 10: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

4. Allgemeine Beschreibung

Installation instruction TERRA CL10

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

d

f

b

h

a

l

k

j

i

g

ad

e

t

m

1

2

3

4

5

Dim

ensions

4. Dimensions

Conduit bushings in TERRA CL HGL:

1 ... HGL fl ow (fl ex. connection hose)2 ... Heating fl ow (fl ex. connection hose)3 ... Sensor and control lines4 ... Heating return5 ... Condensation run-off

Conduit bushings in TERRA CL BA:

1 ... Heating fl ow (fl ex. connection hose)2 ... Sensor lines3 ... Control lines (CL 12-15 heating return)4 ... Heating return (CL 12-15 control lines)5 ... Condensation run-off

Typ b h t a d e f g i j k l m8 1100 1535 750 640 865 690 1035 575 460 350 240 125 12510 1100 1535 750 640 865 690 1035 575 460 350 240 125 125

12 1200 1635 780 640 965 720 1135 575 460 350 240 125 12515 1200 1635 780 640 965 720 1135 575 460 350 240 125 125

20 1200 1735 880 740 965 820 1135 675 540 400 260 125 125

25 1300 1935 980 740 1165 920 1235 675 540 400 260 125 12530 1300 1935 980 740 1165 920 1235 675 540 400 260 125 12533 1300 1935 980 740 1165 920 1235 675 540 400 260 125 125

TERRA CL 08-33

Alle Maße in mm

4.1 . Heat Pump CL

Page 11: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 11

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

Dimensions

Dim

ensi

ons

4 .1 .1 . Cable bushing TERRA CL HGL

4.1 .2 . Cable bushing TERRA CL BA

Page 12: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

4. Allgemeine Beschreibung

Installation instruction TERRA CL12

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

600

560

180

T B

H

Dimensions

Dim

ensions

4 .2 . Control cabinet

4 .3 . I ntake box (opt ional accessor ies)

The control cabinet contains the complete heat pump control system. It is separate from the heat pump, mounted on a suitable wall with the frame screws provided.

The connection cables are laid through the PG screw connections provided on the bottom of the control cabinet.

All dimensions in mm

Type TERRA CL B H t08-10 1098 924 600

12-15 1198 1024 700

Page 13: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 13

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

Dimensions

Dim

ensi

ons

Note :

Page 14: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL14

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

5. Interior installation

5.1. I nsta l lat ion I nstruc t ions

Interior installation of the heat pump is recommended. This means that the work involved in frost protection and condensation run-off heating can be avoided. It also means that the inlet air / outlet air can be con-veyed to the heat pump with the least possible heat losses. Various installation options are described in detail in the following chapters.

All components of the heat pump are insulated so that no condensation is formed on the external parts even at outlet air temperatures of -20°C. However, it is still advisable to air the room regularly.

The heat pump is decoupled via vibration dampers. The installation location should consist of a solid base.

5.2 . Heat ing Connec t ion

A fl exible hose set is included as standard for heating connections. See technical data for appropriate con-nection sizes for specifi c machines. It is advisable to use air source heat pumps only in combination with a buffer tank such as the IDM Hygienik Tank.

5.3 . Condensat ion run- off

Air source heat pumps generate condensation during operation. With larger machines, up to 50l of water can be extracted from the ambient air per day. The condensation run-off should be conveyed into the waste water channel via a siphon using the appropri-ate pipe diameter for the machine.

5.4 . Ai r Rout ing

The various air ducts (see accessories for interior installation) and wall openings are designed specifi -cally for the relevant machines in question. Effi cient and fault-free operation can only be ensured if the appropriately sized connection elements are used.

5.5 . Ai r I n let and Outlet

The options for how the air inlet and air outlet are designed are varied. The list below provides design guidelines:

- Air inlet side and air outlet side should always be on two different sides of the building.

- Openings in the masonry must always be protected against the penetration of foreign bodies (leaves, small animals). To do this, mesh grilles should be fi t-ted in light shafts, and weather-shield grilles should be installed on visible walls.

- Wall openings must be created as per the specifi ca-tions and insulated against damp penetration using a closed-pore insulating material (minimum thick-ness 50 mm).

Even light shafts which are too small enlarge the pressure loss of the air rout-ing. These must therefore be suffi ciently large.

Light shafts must have a rainwater run-off.

Page 15: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 15

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Inte

rior

inst

alla

tion

5 .6 . Noise

Noise level in the installation room depends on various factors such as room size, absorption capacity, refl ection, free noise propagation, etc. For this reason, it is important that the heat pump is situated as far as possible from noise-sensitive areas. A noise-insulating door should be fi tted.

The night-time reduction in the fan speed means that noise can be reduced by up to 4 dB. Noise level on the inlet and exhaust air openings are also reduced by approx. 4 dB when using air shafts or ducts.

In case of exterior installation, the installation of the heat pump in a corner can lead to a higher noise level. Superposition of the sound waves means that noise level can increase up to 3 dB.

5.7 . Noise expansion

The father you leave the noise source, the noise energy will get "smaller" and the immission value will reduce. Dependent from the source typ you will have more or less decrease.

Is the noise source directly on the ground, a 1/2-sphe-reshaped noise level-decrease could accepted. The noise level for different distances you will fi nd in tables. On the Pic down you see the noise level-decrease for TERRAL CL.

By noise-refelxion or nois-absorption because of local conditions, in the practice differences are possible.

0

5

10

15

20

25

30

0 2 4 6 8 10 12 14 16

Noiseleveldecrease[db(A)]

Distance [m]

Page 16: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL16

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Interior installation

- The heat pumps should be installed in a frost-proof room. (Room temperature should be between 5°C and 35°C)

- In case of a fl oating fl oor screed the screed and the sound damping around the heat pump have to be omitted.

- Heat pumps should not be installed in wet rooms or in potentially dust or explosion-endangered rooms.

- Gas from refrigerants in plant rooms must not es-cape into vicinal rooms, stair rooms, courtyards, walks or into the drainage system of the building. The gas has to be channelled off safely.

- In case of danger, the plant room has to be eva-cuated immediately.

- For powering off the cooling facility, a remote power-off switch has to be installed nearby the door of the plant room.

- A mechanical ventilation on site is only essential, if the minimum dimension of site (see page 6) is below the limit . In that case a mechanical ventilati-on (EN 378) is essential!

5 .9 . I nsta l lat ion space

T

T

12

34

1. Concrete floor2. impact sound isulation3. floor screed4. recess

Observe:

• effects of obstacles• Objectrefelxions• groundrefl exions• Absorption because of plants• Effects of wind and Temperature-stratifi cation

5.8 . Decoupl ing of bui ld ings

To reduce vibrations and noises in the building, heat pumps must be decoupled best possible. Don't pre-pare heat pumps on lightwight construction fl oors. If you have a fl oating fl oor screed, the fl oor screed near to the heat pump must recessed (see pic below).

For outdoor heatpumps the adjustet noise level is decisive!

5m

10m

10m

10m

10m

5m

5m

5m

Page 17: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 17

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

min. 500mm

Interior installation

Inte

rior

inst

alla

tion

5 .10 . Corner insta l lat ion

The ideal position for the heat pump has proved to be in a corner. Wall openings can be prepared by the customer in advance. These openings must be insu-lated with closed pore insulating material (minimum thickness 50 mm).

5.10.1 . Space Required and Access ibi l i t y

To guarantee maintenance and operation of the heat pump, the following minimum distances must be observed:

Front side (operation and maintenance side) = 800 mmMaintenance side = 500 mm

Observing these distances will help ensure problem-free system maintenance and operation.

A condensation run-off with siphon must normally be fi tted opposite the exhaust air opening for the heat pump.

Heating connection /Condensation run-off/Electrical connections

Page 18: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL18

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5a

b d

c

ee

f g

a

bd

c

ee

fg

Interior installation

Interior installation

Based on accessibility, the exhaust air opening should ideally be on the right-hand side.

Specifi ed dimensions include clearances. Wall opening should be thicker around the wall insulation. Minimum thickness of the wall insulation is 50 mm.

5.10.2 . Customer preparat ion

Exhaust air opening to right Exhaust air opening to left

An even, solid installation surface must be selected. After positioning the heat pump, it must then be lev-elled. There are adjustable feet on the heat pump for this purpose.

Type a b c d e f g8 1000 830 650 830 90 650 65010 1000 830 650 830 90 650 650

12 1100 930 680 930 90 650 65015 1100 930 680 930 90 650 650

20 1100 930 780 930 90 750 750

25 1200 1130 880 1130 90 750 75030 1200 1130 880 1130 90 750 75033 1200 1130 880 1130 90 750 750

TERRA CL 08-33

All dimensions in mm

Corner installation

Page 19: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 19

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Pos. 341

Pos. 342 (343)

Pos. 345 (346)

Pos. 344

Interior installation

Inte

rior

inst

alla

tion

5 .10 .3 . Accessor ies for corner insta l lat ion

Pos. 341 .... Wall connection intake (for tight transfer)Pos. 342 .... Weather shield grille intakePos. 343 .... Mesh grille intakePos. 344 .... Wall connection outlet (for tight transfer)Pos. 345 .... Weather shield grille outletPos. 346 .... Mesh grille outlet

5.10.4 . Assembly I nstruc t ions - Corner I nsta l lat ion

Wall connection is supplied separately. Vertical connections must be affi xed fi rst. To do this, simply remove the fi lm on the rear side. The cellular rubber can then be affi xed fl ush with the external edge of the heat pump. Additionally the horizontal elements are also lined on the front. This will help ensure an optimum seal.

Before the machine is positioned in the corner, a check should be carried out to ensure that the wall opening prepared by the customer has been insulated. The machine can then be moved into the corner.

If there are any air gaps on the outlet or inlet open-ings due to the ground being uneven, this can be corrected using the adjustable machine feet.

Noise level in the installation room depends on vari-ous factors such as room size, absorption capacity, refl ection, free noise propagation, etc. For this rea-son, it is important that the heat pump is situated as far as possible from noise-sensitive areas. A noise-insulating door should be fi tted.

Signifi cant pressure against the wall should be avoided.

The heat pump may only be moved with the panels fi tted.

Page 20: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL20

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Interior installation

5 .11 . I nsta l lat ion – Standard a i r duc t

If there are no two external walls directly available for installation, the air fl ow can be conveyed outwards via insulated air ducts. Our range includes standard air ducts which can be connected directly to the heat pump without adaptation.

There are two ways to do this:

Option 1

Option 2

This method is used if there are no two external walls available. As a short circuit may occur between the supply and exhaust sides with this method, the inlet and outlet should be positioned as far apart as pos-sible. The unit can be separated from any shrubbery by fi tting dividing walls if necessary.

This method is equivalent to corner installation. This method can be used if corner installation is not pos-sible due to space restrictions or if a gap needs to be bridged between the heat pump and outlet side.

Air ducts can be connected to the right and left of the heat pump. Heating and electrical connections can also be fi tted on both sides.

Page 21: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 21

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Pos. 341

Pos. 342 (343)

Pos. 421 Pos. 423(424)

Pos. 425 Pos. 426

Pos. 427 (428)

Pos. 341

Pos. 342 (343)

Pos. 421 Pos. 423(424)

Pos. 426

Pos. 427 (428)

Interior installation

Inte

rior

inst

alla

tion

5 .11 .1 . Accessor ies – Standard a i r duc t

Option 1:

Option 2:

Pos. 341 ... Wall connection intakePos. 421 ... Outlet panel right / leftPos. 423 ... Duct (1000 mm)Pos. 424 ... Duct (1500 mm)Pos. 425 ... Elbow 90°Pos. 426 ... Wall connection

Pos. 342 .... Weather shield grille intakePos. 343 .... Mesh grille intakePos. 427 .... Weather shield grille outletPos. 428 .... Mesh grille outlet

The air ducts are delivered with the installation material (screws, washers, nuts).

Page 22: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL22

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5 a

bc

de

f

g

Type a b c d e f g**8 1000 830 500 700 650 720 110010 1000 830 500 700 650 720 1100

12 1100 930 500 700 650 770 110015 1100 930 500 700 650 770 1100

TERRA CL 08-15

All dimensions in mm

Standard duct - Version 1 (90°)

** for 1000 mm duct length / length can be cut to size as required

Interior installation

Interior installation

5 .11 .2 . Customer preparat ion – Option 1

Specifi ed dimensions include clearances. Wall opening should be thicker around the wall insula-tion. Minimum thickness of the wall insulation is 50 mm.

Page 23: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 23

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5a

b

c

d

ef

gh

Type a b c d e f g** h8 1000 830 500 700 650 720 1100 27010 1000 830 500 700 650 720 1100 270

12 1100 930 500 700 650 770 1100 27015 1100 930 500 700 650 770 1100 270

TERRA CL 08-15

All dimensions in mm

Standard duct - Version 2 (180°)

** for 1000 mm duct length / length can be cut to size as required

Interior installation

Inte

rior

inst

alla

tion

5 .11 .3 . Customer preparat ion – Option 2

Specifi ed dimensions include clearances. Wall opening should be thicker around the wall insulation. Minimum thickness of the wall insulation is 50 mm.

Page 24: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL24

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Interior installation

5 .11 .4 . Assembly instruc t ions - Standard duc t

Air Inlet Side

The inlet-side wall connection is supplied separately. Vertical connections must be affi xed fi rst. To do this, simply remove the fi lm on the rear side. The cellular rubber can then be affi xed fl ush with the external edge of the heat pump.

Additionally the horizontal elements are also lined on the front. This will help ensure an optimum seal.

Before the machine is positioned on the inlet opening, check that the wall opening prepared by the customer has been insulated.

If there are any air gaps on the outlet or inlet openings due to the ground being uneven, this can be corrected using the adjustable machine feet.

The heat pump may only be moved with the panels fi tted.

Signifi cant pressure against the wall should be avoided.

If two or more ducts are assembled together, the duct must be supported (above or below).

Outlet Panel

The outlet panel is mounted using the four clamps supplied.

Duct:Assemble the duct using the screw set supplied. The fi tting length should then be checked.

If the straight duct is too long, two rivets can be bored open on one side so that the fl ange can be removed. The duct can then be cut to length using an angle grinder or a jigsaw with the relevant blade. The fl ange can then be re-fi tted.

Insulation:The insulation for the straight duct is supplied sepa-rately. This is self-adhesive and needs to be affi xed once the duct has been cut to the correct length.

Wall connection:The wall connection is sprayed into the wall opening with assembly foam. The outlet duct must be con-nected before the foam hardens.

Page 25: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 25

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Inte

rior

inst

alla

tion

5 .12 . I nsta l lat ion – Flexible a i r hose

This option is suitable for connecting to air openings at varied heights. The air hose is supplied in three different lengths and can be cut to length as required.

Option 1

Option 2

Page 26: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL26

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

a

b

c

d

e

f

a

b

e

c

d

TERRA CL 8 15flexible hose

Typ a b c d e f Ø air hose8 1000 830 620 620 650 >1000 50010 1000 830 620 620 650 >1000 500

12 1100 930 720 720 650 >1000 60015 1100 930 720 720 650 >1000 600

all dimenions in mm

Interior installation

Interior installation

5 .12 .1 . Customer preparat ion – Flexible a i r hose

Specifi ed dimensions include clearances. Wall opening should be thicker around the wall insula-tion. Minimum thickness of the wall insulation is 50 mm.

Option 1

Option 2

Page 27: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 27

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Pos. 341

Pos. 342 (343)

Pos. 381 Pos. 387 Pos. 3861(3862)(3863)

Pos. 387 Pos. 383 Pos. 384(385)

Pos. 342 (343)

Pos. 388

Pos. 384 (385)

Pos. 383Pos. 3861(3862)(3863)

Pos. 382

Pos. 344

Interior installation

Inte

rior

inst

alla

tion

5 .12 .2 . Accessor ies – Flexible a i r hose

Pos. 341 ... Wall connection intakePos. 381 ... Outlet panel right / leftPos. 3861 ... Insulated air hose (5 m)Pos. 3862 ... Insulated air hose (3 m)Pos. 3863 ... Insulated air hose (2 m)Pos. 383 ... Wall fl ange

Optional accessories:

Pos. 342 .... Weather shield grille intakePos. 343 .... Mesh grille intakePos. 382 .... Top outlet panelPos. 384 .... Weather shield grille outletPos. 385 .... Mesh grille outletPos. 388 ... Side panel right / left

Option 1 Option 2

Page 28: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL28

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Interior installation

5 .12 .3 . Assembly instruc t ions – Flexible a i r hose

Air Inlet Side

The inlet-side wall connection is supplied separately. Vertical connections must be affi xed fi rst. To do this, simply remove the fi lm on the rear. The cellular rubber can then be affi xed fl ush with the external edge of the heat pump.

Additionally the horizontal elements are also lined on the front. This will help ensure an optimum seal.

Before the machine is positioned on the inlet opening, check that the wall opening prepared by the customer has been insulated.

The heat pump may only be moved with the panels fi tted.

Signifi cant pressure against the wall should be avoided.

If there are any air gaps on the outlet or inlet openings due to the ground being uneven, this can be corrected using the adjustable machine feet.

Outlet panels:

The outlet panel is mounted using the four clamps supplied.

Wall fl ange:

The wall fl ange must be fi tted to the air outlet opening using suitable mounting materials. There are four bore holes at the corners of the fl ange for this purpose.

Flexible hose:

The hose can be cut to any size required. For con-necting the two fl anges, the hose insulation is pushed together at both ends.

The hose is fi tted onto the fl ange using a hose clamp. The insulation can then be pushed back onto the fl ange.

The air hose should be supported by a bracket every 0.5 m.

Page 29: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 29

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Pos. 405

Pos. 383

Pos. 384(385)

Pos. 383Pos. 384(385)

Pos. 3861(3862)(3863)

Pos. 402

Pos. 3861(3862)(3863)

Pos. 381Pos. 388

Interior installation

Inte

rior

inst

alla

tion

5 .13 . Flexible a i r hose with a i r intake box

Pos. 381 ... Outlet panel right / leftPos. 3861 ... Insulated air hose (5m)Pos. 3862 ... Insulated air hose (3m)Pos. 3863 ... Insulated air hose (2m)Pos. 383 ... Wall fl angePos. 402 ... Air intake box with connection on topPos. 405 ... Air intake box with lateral connection

Optional accessories:

Pos. 384 .... Weather shield grille outletPos. 385 .... Mesh grille outletPos. 388 .... Side panel right / left

The dimensions for the wall openings, and the openings for the outlet hose, are listed on page 23.

Page 30: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

5. Allgemeine Beschreibung

Installation instruction TERRA CL30

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Interior installation

5 .14 . Convers ion f rom lef t to r ight-s ide connec t ion

The larger TERRA CL and also all TER-RA CL HGL machines need no other pipe clamp. It's also not necessary to shorten the thread rod. You only have to turn the connection by 180°.

The TERRA CL HGL is pre-fi tted with left-hand side connection openings. The connection side can be changed if required. The following steps are required to do this:

Remove the panels on the left and the right-hand side by unfastening the eight respectively four screws.

Remove the central bar and the assembly angle by unscrewing the clamping screws above and below.

Converting the hydraulic pipework CL 8-10 BA

For converting the hydraulic pipework remove the left-hand side pipework and the cable fi ttings.

2

3

4

1

To remove the pipework unfasten the pipe clamps (2) and the connection angle (3) on the plate heat exchanger. Turn the upper elbow joint by 180° and tighten again (according to the picture). Tighten the fi xing clips and threaded rods. Install the circulation pump and turn the pump head back.

The heating side connection of the elec-trical heater may not be exposed to hea-vy tension!

For the upper pipework remove the copper extension pipe (1) at the connection (4). The heating side con-nection is carried out directly on the electrical heater.

Mount the thread rod in the provided tap hole on the right side of the base plate. To fi x the upper pipework you have to shorten the upper thread rod. So you can fi x the pipework with the thread rod and the provided pipe clamp (54 - 59mm) on the electical heater.

Re- fasten all connecting cables using the cable bin-der. Then re-fi t the panels onto the opposite side.

Page 31: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 31

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

Interior installation

Inte

rior

inst

alla

tion

Note :

Page 32: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

6. Allgemeine Beschreibung

Installation instruction TERRA CL32

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

Exterior installation

6. Exterior installation

6.1. Customer preparat ion

Foundation:The foundation should be level and stable. A base can be provided by the customer or a paving slab can be laid on a gravel base. The air source heat pump should be positioned slightly higher than the immediate site profi le.

Space requirements:The heat pump must be positioned so that there is suffi cient space for air intake and air outlet (see mini-mum distances for exterior installation). It should not be possible for the inlet and exhaust air openings to become blocked by snow, leaves, etc.Installation in wall niches is to be avoided.

Inlet air:The inlet air must be free of impurities such as sand and caustic materials such as ammonia, sulphur, chlorine, etc.

Condensation pipe:The condensation pipe must be laid so that the water can also fl ow off even at outside temperatures below 0°C. A heatable siphon should be fi tted. Alternatively, an electrical self-regulating heating cable can be used that is selected via the Navigator Control.

Frost protection:If, in the case of bivalent-alternative operation, the HP is shut down at low outside temperatures, there is a potential danger that the heating lines and the condenser plate heat exchanger could freeze.

The following frost protection options are possible:

- Electrical self-regulating heating cable on pipes and condenser

- Frost protection function of the control system.

Heating connections:

In general, all lines outdoors should be kept as short as possible. All pipes and wall openings must be pro-fessionally heat-insulated and frost-protected during installation.

It might be necessary to install a self-regulating elec-trical heating cable to protect the lines from frost.

Installation location:

Despite the reduction in speed during the night, the heat pump should not be positioned adjacent to a living room or bedroom. The relevant installation guidelines conforming to EN 378, for example, must be observed.

Page 33: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 33

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

min. 1 m

min. 2 m min. 2 mmin. 0,8 mC

DE

B

A

alternativ

connection heating sidecondensation run off

Pos. 491

Pos. 494

Pos. 301 Pos. 301

Pos. 302

Pos. 303Pos. 306

Exterior installation

Exte

rior

inst

alla

tion

6 .2 . Distances

Type TERRA CL A B C D E08-10 750 1100

190 150 12512-15 780 1200

20 880 1200

25-33 980 1300

6.3 . Accessor ies – Ex ter ior insta l lat ion

Noise insulation cover intake

Noise isulation cover outlet

Pos. 301 ... Unit roof coatedPos. 302 ... Weather shield grille intakePos. 303 ... Weather shield grille outletPos. 306 ... Cover box - insulatedPos. 491 ... Noise insulation cover intakePos. 494 ... Noise insulation cover outlet

Type Terra CL H B T08-10 891 1089 401

12-20 991 1189 451

25-33 1191 1289 601

Type Terra CL H B T08-10 864 739 401

12-15 964 769 451

22 964 869 451

25-33 1164 969 601 All dimensions in mm!

Page 34: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

7. Allgemeine Beschreibung

Installation instruction TERRA CL34

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

Heating Side Connection

7. Heating Side Connection

7.1. Requirement heat ing s ide connec t ion

The relevant laws, regulations and standards for ma-chine room piping and for heat pump systems must also be observed.

- It is essential that a dirt trap is fi tted in the heating return pipe.

- Safety devices and expansion devices for closed heating systems according to EN 12828 must be fi tted.

- The dimensioning of the lines must be in accordance with the required fl ow volumes.

- The connection hoses supplied for the heat pump fl ow and return lines must always be installed. The connection hoses can be cut to the required length, but not shorter than 60 cm. In addition, the connec-tion hoses must not be bent.

- Venting options should be fi tted at the highest points of the connection lines, and draining options at the lowest points.

- To avoid heat loss connection lines should be insu-lated using suitable material.

Oxygen diffusionWith plastic pipe underfl oor heating or open heating systems which are not diffusion-tight, corrosion may occur on steel parts when using steel pipes, steel radiators or storage tanks due to oxygen diffusion.

Corrosion products can be deposited in the conden-ser and may cause heating losses to the heat pump or high-pressure faults.

For this reason, open heating systems or steel pipe installations in combination with plastic pipe under-fl oor heating which is not diffusion-tight should be avoided.

Heating water qualityDepending on the quality of the heating water, lime scale may occur (adherent coating primarily consisting of calcium carbonate) on heat exchanger surfaces in particular, i.e. with a high proportion of calcium hydro-gen carbonate there is a risk of lime scale forming.

For this reason, in systems with a water hardness of over 14°dH or with a calcium hydrogen carbonate concentration of more than 2.5 mol/m³, the heating water should be treated accordingly (softened/demi-neralised).

Information on the calcium hydrogen carbonate con-centration c(Ca(HCO3)2) of your heating water can be obtained from your water supply company.

The pH value should also be checked; this should be between 8 and 9.5.

- EN 12828 - ÖNORM H 5195 - VDI Directive no. 2035

Incorrect fl ow volumes due to incorrect pipework, incorrect fi ttings or incorrect pump operation may cause damage.

Page 35: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 35

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T T

TT

T

T

MM

T

T

B32 B61

B51

B335B33B3333

B3B3B3999

B41 B42

B1

M222

M211

B52

B62

M31

M41

M322

M4222

HW

CW

separation plate

HygienikTERRA CL HGL

RE (B) RE (A)

HC (A)HC (B)

FS FS

OS

Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the

function of the whole system!

Heating Side Connection

Hea

ting

Sid

e Co

nnec

tion

When using a fl ow meter to measure the heat volume, the sensor B39 must be fi tted in an immersion sleeve in the heat pump return directly in the heat pump (see installation instructions fl ow meter).

7.2 . TERRA CL HGL heat pump with IDM H ygienik with separat ion plate

During the priority charging procedure, the top area of the storage tank is charged with the speed-controlled charging pump at the set HGL temperature.

During the heating operation of the heat pump, a proportion of the fl ow is always charged into the top storage tank area via the HGL exchanger and the HGL valve at the set HGL temperature.

This keeps the Hygienik at the right temperature whilst at the same time the lower storage tank area is better used as a buffer due to the higher temperature, this means

- longer running times for the heat pump - longer deadtimes - more tapwater and higher tapwater temperature

Page 36: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

7. Allgemeine Beschreibung

Installation instruction TERRA CL36

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T

T

T

T

TT

MM

T

T

B51B52

B62

M31

M41

M32

M4222

B322

B3B 55B33

B4B4B4111

B42

B1

M22MM 2

M21

B3B3B3999

BufferHygienik

OS

HW

CW

TERRA CL HGL

RE (B) RE (A)

HC (A)HC (B)

FS FS

Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the

function of the whole system!

Heating Side Connection

Heating Side Connection

7 .3 . TERRA CL HGL heat pump with IDM H ygienik and heat ing buffer

The Hygienik is only used to prepare tapwater and during the priority charging procedure is charged with a speed-controlled charging pump at the set HGL temperature.

The heating is supplied via an additional heating buffer. During the heating operation of the heat pump, the top area of the Hygienik is recharged at the set HGL temperature.

When using fl ow meters to measure the heat volume, sensor B39 must be fi tted in an immersion sleeve in the heat pump return directly in the heat pump (see installation instructions fl ow meter).

Page 37: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 37

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T

T

P

T

M

T

T

M

T

M

T

B32 B61

B51

M21

B39

B41M63

M31

M41

M322

M42

B52

B62

B1

B42

M22

B333

TERRA CL BA Hygienik

HW

CW

FSFS

HC(A)HC(B)

Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the

function of the whole system!

Heating Side Connection

Hea

ting

Sid

e Co

nnec

tion

When using a fl ow meter to measure the heat volume, the sensor B39 must be fi tted in an immersion sleeve in the heat pump return directly in the heat pump (see installation instructions fl ow meter).

7.4 . TERRA CL BA heat pump with H ygienik and separat ion plate

Page 38: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

7. Allgemeine Beschreibung

Installation instruction TERRA CL38

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T

P

T

M

T

M

T

M

T

T

B32 B61

B51

M21

B4B4B 11

M63

B39B3B 33

M31M41

M32M42

B52

B62

TERRA CL BABuffer Hygienik

HW

CW

RE(A)

FS

OSRE(B)

FSHC (A)HC (B)

Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the

function of the whole system!

Heating Side Connection

Heating Side Connection

7 .5 . TERRA CL BA heat pump with H ygienik and without separat ion plate and heat ing buffer

For larger systems (over approx. 27kW), with either signifi cant hot water consumption or a very low hot water consumption, it is advisable to separate the heating buffer and the Hygienik. The buffer in question is heated via the priority valve as required. For hot water supply, a Hygienik without separation plate is used.

When using a fl ow meter to measure the heat volume, the sensor B39 must be fi tted in an immer-sion sleeve in the heat pump return directly in the heat pump (see installation instructions fl ow meter).

Page 39: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 39

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T

T

P

T

M

T

T

M

T

M

P

T

B322 B61

B51

M21

B39

B41M63

M31

M41

M322

M42

B52

B62

B1

B42

M22

B33

TERRA CL BA Hygienik

HW

CW

RE(A)

FS

OS RE(B)

FS

Oil-/Gas burner

HC(A)HC(B)

Note: This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no professional planning of an executing companie! On part of IDM-Energiesysteme can no warrenty be taken concerning the

function of the whole system!

Heating Side Connection

Hea

ting

Sid

e Co

nnec

tion

7 .6 . TERRA CL BA oi l /gas boi ler, H ygienik with separat ion plate and heat ing buffer

Switching in of the oil boiler is carried out via the potential-free contact for the second heat generator. (Terminal strip X2 terminals 3 and 4)

Page 40: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

7. Allgemeine Beschreibung

Installation instruction TERRA CL40

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

T

TT

T

MM

M

B

A

P

T rH% T

M

M

T

T

T

T

T

HygienikTERRA CL HGL-P

RE (B) RE (A)

HC (A)HC (B)

FSFS

Coolingvalve

OS

HW

CW

Coolingvalve

Cooling buffer

Coolingvalve

Note: On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no

professional planning of an executing company!

Separation plate

B61

B51B52

B62

M31

M41

M322

M422

M61

BB39B39

B41B42

B1

M222

B32

M62

M62

M21

B35B33

BBB40

B31

Heating Side Connection

Heating Side Connection

7 .7 . TERRA CL HGL-P with process reversal for cool ing and H ygienik with separat ion plate

A room humidity sensor resp. dew point switch must be installed for dew point monitoring. (see installation instruction room humidity sensor resp. dew point switch!)

Page 41: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 41

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

TT

TT

T

T

MM

M

P

T rH% T

M

M

M

T

T

HygienikTERRA CL BA

RE (B) RE (A)

HC (A)HC (B)

FSFS

Coolingvalve

OS

HW

CW

SPF

Separation plate

Coolingvalve

Cooling puffer Coolingvalve

Note: On part of IDM-Energiesysteme can no warrenty be taken concerning the function of the whole system! This is only a tentative suggestion for installing an IDM heat pump in the heating system. This suggestion replaces no

professional planning of an executing company!

B61

B51B52

B62

M31

M41

M322

M422

M61

B39B39B39

B41B42

B1

M222

B32

M62

M62

M21

B33

B400 M63

B31

Heating Side Connection

Hea

ting

Sid

e Co

nnec

tion

7 .8 . TERRA CL BA-P with process reversal for cool ing and H ygienik with separat ion plate

A room humidity sensor resp. dew point switch must be installed for dew point monitoring. (see installation instruction room humidity sensor resp. dew point switch!)

Page 42: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

8. Allgemeine Beschreibung

Installation instruction TERRA CL42

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

C L

Primary currentelectric immersion heater (3x400V/50HZ)

Power supplyelectric immersion heater 5G1,5mm²

Sensors 18G0,75mm²

Control current 25G1,0mm²

Power supply compressor 1

Power supply compressor 2 (Terra CL TWIN)

Power supply evaporator fan

Primary current heat pump (3x400V/50HZ)

Control current (1x230V/50HZ)

Sensor and control lines on-site

Navigator control cabinet

Heat pump TERRA CL

Electrical connection

8. Electrical connection

8.1. Power supply

Electrical connection must be registered with the relevant power supply company.

The necessary series-connected fuse for the primary circuit can be found in the technical data. It is essential that a fuse design is used (“C” or "K" characteristic). The relevant cable cross section must be determined by the electrician.

All systems are equipped with a start-up current limiter.The heat pump is operated via the Navigator Control.

Depending on system design, the relevant sensors are required; see the connection diagrams on the fol-lowing pages for more information.

For reliable operation of the heat pump, the voltage in the mains network must be within specifi c tolerance limits, between 360 and 430 V (check with the rel-evant power supply company if necessary).

The connection cables between the control cabinet and the heat pump are not included in the scope of delivery. The layout of the respective line cross section for the compressor must be carried out by an electrician according to the technical data (see page 6). The power consumption of the compressor can also be taken from the wiring diagram enclosed.

Connection box with terminal blocks in heat pump TERRA CL

Page 43: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 43

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

T 6,3 A

T 6,3 A

T 6,3 A

T 3,15 A

T 1,6 A

T 800 mA

T 160 mA

Display

X1

B

1

2

X6

X11

X5

F10

K1

External expansionmodul/

Cascade user

Internal expansion module

Control unit

SD- C

ard

LAN

EIB/

KNX

Step

mot

or m

odul

e

GSM- module

Central processing unit

H8F6

F1

F2

H4

F8

F4

F5

H7

F10

H6

F3

H5

H1

H3H2

-

+

SD-Card

Electrical connection

Elec

tric

al c

onne

ctio

n

8 .2 . Connec t ion Diagram Elec tr ica l Components

The central unit of the control system is located in the control cabinet. All connections on the central unit are designed as pluggable.

Additional modules such as the internal expansion module for another two heating circuits, as well as the external expansion module for three heating circuits and the GSM module, are connected in accordance with the diagram below.

Page 44: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

8. Allgemeine Beschreibung

Installation instruction TERRA CL44

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

C L

L1 L2 L3

T1 T2 T3

L1 L2 L3

T1 T2 T3

37

38

21 12

X1

X1

X2

X211

L PEN PE

1

N

Q1 Q2

Prim

ary

curr

ent

heat

pum

p 3x

400V

/ 50

Hz

Prim

ary

curr

ent

Ele

ctric

hea

ting

elem

ent

3x40

0V /

50H

z

Con

trol c

urre

nt 1

x230

V /

50H

z

Electrical connection

Electrical connection

8 .3 . Power Supply Connec t ion

The connection of the primary circuit for the heat pump and for the electric immersion heater, as well as for the control power connection, is executed directly on the control cabinet of the CL heat pump.

Control power connection: 1x230 V / 50 HzPrimary current heat pump: 3x400 V / 50HzPrimary current electric immersion heater: 3x400 V / 50Hz

The supply lines must have the relevant thickness. For more information, see technical data regarding max. power consumption.

The wiring must be carried out in accordance with the electric wiring diagram enclosed with the heat pump.

8.4 . Connec t ion l ines control cabinet - heat pump

Connection line electric heating:The supply line for the electric immersion heater can be carried out with 5G1.5 mm² for heat pump designs CL 08-15. For larger heat pumps, the connection ca-ble must be designed in accordance with the output data of the electric immersion heater used on-site.

Sensors - connection line:The connection line for the sensors is designed as 18G0.75 mm² cable.

Control current connection line:The connection line for the control current is designed as 25G1 mm² cable.

Evaporator fan cable:The connection line for the evaporator fan is designed as 5G1,5 mm² cable.

Compressor cable:The compressor cable is designed as 4-pole cable. The line cross section must be designed in accord-ance with the power consumption of the compressor.CL 08-15 ... 1 x 4G1,5mm²CL TWIN 20-30 ... 2 x 4G1,5mm²CL 33 ... 1 x 4G6,0mm²

The electrical connection of the connec-tion lines between the heat pump and switch cabinet must be taken from the enclosed wiring diagram.

The power consumption of the com-pressors can also be taken from the enclosed wiring diagram.

Page 45: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 45

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

Electrical connection

Elec

tric

al c

onne

ctio

n

8 .5 . EMC

Please take note of the following with regard to this is-sue: Electro-Magnetic Compatibility (EMC) demands additional work and expertise from all manufacturers and operators of modern electrical technology and electronics year on year.

As the number of electronic devices in use increases continually, the number of potential sources of inter-ference also increases. A combination of cables from the power supply company, transmission stations and other communications devices generate an invisible “electrosmog".

This interference affects all systems, both biological (us as living beings) as well as technical electrical systems. They generate undesirable fault currents which can have different effects.

The effects on biological systems can only be guessed at currently, but the effects on technical electrical sys-tems are measurable, and in the worst case, visible as well.

The faults can have different effects:

- Short-term measurement faults - Permanent measurement faults - Short-term interruption in data connections - Permanent interruption in data connections - Data losses - Damage to equipment

Potential sources of interference are essentially all technical electrical systems, e.g. contactor coils, electric motors, transmitters, mains and high-voltage lines, etc., and the equipment can be affected via dif-ferent coupling routes (galvanic, inductive, capacitive, via radiation).

As far as we are concerned, everything has been done to protect the Navigator Control from interfer-ence (Hardware design, EMI-proof electrical panel, network fi lter, etc.). In particular, it is the responsibility of the electrician to prevent possible coupling paths when setting up the electrical installation.

Page 46: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

8. Allgemeine Beschreibung

Installation instruction TERRA CL46

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

93

92

94

brownbrown

white

DZ (B3 )whiteVolume flow

HGL flow

Volume flow heating flow

GND

12V DC

95

DZ (B2)

In each heat pump a standard sensor set is included in the delivery, which is supplied in the control cabinet of the heat pump.

Electrical connection

Electrical connection

8 .6 . Layout of the I nputs on the Centra l Unit

The sensor inputs on the central unit are described in the electrical wiring.

8.7 . Sensor design

Sensor lines have a cable cross section of 0.75 mm² as standard.

The sensor positions are shown in the relevant in-stallation diagram. Reliable operation can only be ensured by correct positioning and good heat transfer (heat conducting paste).

If necessary, the sensors can be extended using a suitable cable. It must be ensured that the connection is clean and corrosion-free.

8.7 .1 . Sensor equipment

The following sensors are contained in the scope of delivery or are already installed and, in any case, required:

- Air heat exchanger sensor (B72) - Heat pump fl ow sensor (B33) - HGL fl ow sensor (B35) (only for the HGL design) - Buffer tank sensor (B39) - Air intake sensor (B37) - Flow sensor heating circuit A (B51) - Sensor Hygienik (B41) - Sensor tap water (B42) - Outdoor sensor (B32)

(All other sensors are optional depending on the sys-tem equipment).

8.7 .2 . Flow temperature sensor

The fl ow temperature sensors for the heating circuits used are required in every case. They must be con-nected on the corresponding fl ow lines and in accord-ance with the connection diagram.

The fl ow sensors for the heating circuits C-G are connected on the respective heating circuit expan-sion module. (see the installation instructions for the expansion module for more information)

8.8 . I mpulse I nputs

When using fl ow meters in the heat pump fl ow to measure the heat volume, these are connected as follows:

For installation and confi guration of the Navigator control, see fl ow meter installation instruction.

8.9 . Layout Digita l I nputs

The sensor inputs on the central unit are described in the electrical wiring.

Sensor lines should be run separately from mains cables (see EMC issue).

Page 47: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 47

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

Electrical connection

Elec

tric

al c

onne

ctio

n

8 .10 . Layout Outputs

8.10.1 . Analogue Outputs (80-87)

The analogue outputs on the central unit are de-scribed in the electrical wiring.

8.10.2 . Tr iac outputs (10-12)

The triac outputs on the central unit are described in the electrical wiring.

8.10.3 . Digita l outputs 230V AC (20 -38) :

HGL-heat pumps use inputs 36-37 for the actuation for the circulation pump.

Basic-heat pumps use inputs 36-37 to switch between heating and priority mode.

The digital outputs on the central unit are described in the electrical wiring.

8.11. Ac tuat ion of the changeover valve on the heat source s ide at d i rec t cool ing

According to the hydraulic scheme it may be essen-tial to gate two switching valves parallel. To prevent damage due to induced voltages on the drives, the included auxiliary relay must be installed according to the diagram!

gelb

/grü

n /

yello

w/g

reen

gelb

/grü

n /

yello

w/g

reen

M

N

schw

arz

/ bla

ck

brau

n / b

row

n

blau

/ bl

ue

M

Nsc

hwar

z / b

lack

brau

n / b

row

n

blau

/ bl

ue

32 32 Pe 33 33 N

34 34 Pe 35 35 N

36 36 Pe 37 37 N

L

N

Pe

11A1

A2 14 12 24 22

21

K16

Stellantrieb Umschaltventil 1

StellantriebUmschaltventil 2

Umschaltventil 1 kühlen-heizen (M61)

Umschaltventil 2 Kälte- Heizungsspeicher (M62)

Umschaltventil 3 Heizen - Vorrang (M63)

Navigator Hauptplatine

Page 48: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

8. Allgemeine Beschreibung

Installation instruction TERRA CL48

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

Electrical connection

Electrical connection

M MMM

70 71

Roomthermostat

Zone valve with end switch

Navigator main board

Room 1 Room 2 Room 3

Zone 1 Zone 2 Zone 3

Room engine heating circuit A

If you are using zone valves, you can generate composite signal from all zone valves to be able to switch the heating and cooling circuit on and off with the thermostat function.

8.12. Ac tuat ion of the changeover valve on the heat source s ide at process reversal

To actuate the changeover valve on the heat source side, two additional relay must be fi tted by the cus-tomer, which are connected in parallel to the cooling valve and to the cold-side changeover valve as fol-lows: (see diagram below)

8.13. Connec t ion of the mixers

The ESBE mixers are connected as three-pole according to the wiring diagram enclosed.

Mixer open = brownMixer closed=black

8.14. System Ear thing

When the protective conductor is connected correctly, the electrical panel and the heat pump casing are earthed.

32 32 Pe 33 33 N 30 Pe 31 N

L

White

Green

Y / G

Blue

Red

Black 1~M

12 22

21

NPe

11

2414

White

Green

Y / G

Blue

Red

Black 1~M

NPe

1222

21 11 A1

A2

A1

A2

24 14

Umschaltventil 1 kühlen-heizen (M61)

4-Wege Ventil Kältekreislauf (M51)

Navigator Hauptplatine

Hilfsrelais sind im Lieferumfang der Umschaltventil enthal-ten!

Umschaltventil 3-Wegwärmequellenseitig M74

Umschaltventil 3-WegHeizen-Kühlen M61

After maintenance work, ensure that the equipotential bonding is properly re-established.

8.15. Maximum Restr ic t ion for Under f loor Heat ing

With underfl oor heating circuits, an additional clip-on thermostat must be fi tted and the relevant heating circuit pump supply switched via it in series.

8.16. Composite s ignal zone valves

The composite signal zone valve setting generates a request when one of the zone valves is open. The difference to a roomstat function is that, indepen-dently of heating or cooling operations, a request is generated when a zone valve contact is closed.

8.17. Connec t ion ex ternal preselec ted tar-get value 0-10V

For the connection of the external preselected tar-get value 0-10V the input of the RFF room sensor is used. The external 0-10V signal will indicate the desired temperature for the regulation.

Page 49: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 49

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

Electrical connection

Elec

tric

al c

onne

ctio

n

Note :

Page 50: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH

9. Allgemeine Beschreibung

Installation instruction TERRA CL50

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

9

Comm

issioning

9. Commissioning

9.1. Commiss ioning information

Before start-up of the TERRA heat pump, the heating side must be checked for tightness, rinsed thoroughly, fi lled and bled carefully.

Prerequisites for starting up

- The heating and any storage tank must be fi lled and bled.

- During the start-up the entire buffer tank must be heated to min. 15°C. This, for example, can be done using the electric immersion heater.

- The electrical installation must be complete and fuse-protected in line with legal requirements.

- The heat pump may only be switched on if it is fi lled on the cold side and on the heating side, and if the electrical connections have been checked.

- During start-up, the maximum temperature limit must also be set. The switch-off point of 55°C should be checked and the set shutdown temperature changed as necessary.

- The heat pump is equipped with a start-up delay of 10 minutes so that the compressor only starts run-ning after this period.

- If the heat pump is to be drained on the heating side for frost protection, the connection hose on the heat pump return (plate heat exchanger) must be unfastened.

9.1 .1 . Fi rst switch- on of the heat pump

After actuation of the main switch on the heat pump, the start-up Wizard is started after selecting the lan-guage.

9.1 .2 . Operat ion

The Terra heat pump is switched on and off automati-cally via a fully-automated Navigator Control system. For operation and start-up, please refer to the sepa-rate operation and start-up instructions.

Annual inspection and maintenance of the system by customer services is recommended, in particular with regard to the preserving warranty claims.

9.2 . Mal func t ions

The TERRA heat pump is fi tted with various safety devices to ensure that no damage can be caused to the equipment in the event of faults.

If, contrary to expectations, the heat pump does not work on any occasion, check the error message on the display of the Navigator Control.

For more information, please see the Navigator Con-trol operating instructions.

If an error occurs several times in succession, please contact your IDM Customer Service.

Customer Service telephone:___________________________

According to EU- standard 842/2006, an annual check for heat pumps with more than 3kg refrigerant is prescribed.

Page 51: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P O W E R F A M I L Y

(C) IDM ENERGIESYSTEME GMBH Installation instruction TERRA CL 51

1

2

3

4

5

6

7

8

9

10

11

12

13

1

2

3

4

5

6

7

8

9

Seite 1/1 Revision 2.1

M

IDM-Energiesysteme GmbH Seblas 16-18, 9971 Matrei in Osttirol Phone: 0043 4875/6172, Fax: 0043 4875/6172-85 E-Mail: [email protected], Homepage: www.idm-energie.atUID-Nr.: ATU 433 604 0

Declaration of Conformity (Original copy) IDM-Energiesysteme GmbH, Seblas 16-18, A-9971 Matrei East Tyrol, confirms, that the device(s) referred to below in the version put into circulation by us satisfies/satisfy the requirements of the EC Directives, EC Safety Standards and product-specific ECStandards. The basic components of IDM heat-pumps are condenser, evaporator, pipelines, liquid receiver, valves, surge drum and compressors. General technical Data you can find on the nameplate. A change to the device(s) not authorized by us will render thisdeclaration invalid.

EC Directives

EC Pressure Equipment Directive (97/23/EG)

EC Machine Directive (2006/42/EG)

EC Low Voltage Directive (2006/95/EG)

EC EMC Directive (2004/108/EG)

Details EG-PED (97/23/EG) Fluidgroup: 2 Categorie: II Evaluation procedure: Modul A1

Amongst others, the following harmonized standards have been considered analogously

EN 378 EN 60529 EN ISO 12100-1/2 EN ISO 13857 EN 349 EN 60335-1/2-40 EN 55014-1/2 EN 60204-1 EN 61000-3-2/

Notified body: TÜV AUSTRIA SERVICE GMBH [0408] Krugerstraße 16 1015 Wien

Concerning following products

Direct-evaporation heat-pumps TERRA …DE-HGL (with HGL-technology) TERRA …DE (Basic)

Brine/water respectively water/water heat-pumps TERRA …S/W-HGL (with HGL-technology) TERRA MAX …S/W HGL (with HGL-technology) TERRA …S/W (Basic) TERRA MAX …S/W (Basic) TERRA …S/W-HGL.P (with HGL-technology and process- inverter) TERRA MAX …S/W HGL-P (with HGL-technology and process- inverter) TERRA MAX …S/W-P (Basic and process- inverter)

Air/water heat-pumps TERRA …CL (Basic) TERRA …CL Twin (Basic, two-stage) TERRA …CL-HGL (with HGL-technology) TERRA …CL-HGL Twin (with HGL-technology, two-stage) TERRA …CL-P (Basic with process- inverter) TERRA …CL-P Twin (Basic with process-inverse, two-stage) TERRA …CL-HGL-P (with HGL-technology and process-inverter) TERRA …CL-HGL-P Twin (with HGL-technology and process- inverter, two-stage)

Air/water heat-pumps as split construction with brine-pipework TERRA …SL HGL (with HGL-technology)

Air/water heat-pumps as split construction with refrigerant-pipework TERRA …ML 6 BA (Basic) TERRA …ML 12 HGL (with HGL-technology)

Details on the type, year, serial number and other technical data you can find on the name plate.

Document-authority IDM-Energiesysteme GmbH Seblas 16-18 9971 Matrei in Osttirol

Matrei pp., March 01, 2011 Ing. Andreas Bachler, Technical Director Place, date (Stamp of IDM) Legally binding signature

Commissioning

Com

mis

sion

ing

Page 52: TERRA CL 8-33 HGL/BA (P) (400V) - invisibleheat.co.ukinvisibleheat.co.uk/Manuals/Terra CL HGL BA 8-33 400v (06.12.2011... · TERRA CL 8-33 HGL/BA (P) (400V) ... The fi ns of the

T H E P OW E R FA M I LY

Yo u r I D M p ar t n e r

Always there for you.I D M H E A D Q UA R T E R S I N E A S T E R N T YR O L, AU S T R I A

IDM ENERGIESYSTEME GMBH S eb las 16 – 18 A - 9 971 M atre i in Os t t i ro l , Aus tr iaTe l ep h o n e + 43(0) 4 875. 6172 - 0 Fa x + 43(0) 4 875. 6172 - 85 E - mai l team @idm - en ergie . at

w w w . i d m - e n e r g i e . c o m

IDM - ser vice technology

COMMISSIONING – SERV I CIN G – O N -SI T E SERV I CEO ur s er v ice te chnic ians are hap py to h e lp o n -s i te . Co nt ac t d e t ai ls fo r yo ur re gio nal cus to m er s er v ice centre c an b e fo un d o n o ur website w w w. idm - en ergie .co m .

IDM AcademyPRACTICAL KNOWLEDGE FOR SALES AND TECHNOLOGYT h e co mp re h ensi ve r an g e of s eminar s fo r sp e cia l is t s at th e IDM POW ER FA M ILY is av ai lab l e to yo u at a l l t im es o n o ur websi te w w w. idm - en ergie .co m . We l o o k fo r w ard to re ce i v in g yo ur re gis t r at io n .

ONE STEP AHEAD*T H E P OW E R FA M I L Y

© IDM ENERGIESYSTEME GMBH Matrei i. Osttirol 05.12.11 · Errors and omissions excepted

T H E P OW E R FA M I LY

Yo u r I D M p ar t n e r

I D M H E A D Q UA R T E R S I N E A S T E R N T YR O L, AU S T R I A

IDM ENERGIESYSTEME GMBH S eb las 16 – 18 A - 9 971 M atre i in Os t t i ro l , Aus tr iaTe l ep h o n e + 43(0) 4 875. 6172 - 0 Fa x + 43(0) 4 875. 6172 - 85 E - mai l team @idm - en ergie . at

w w w . i d m - e n e r g i e . c o m

IDM Academy