Egg TechnicalSpecifications(June2017) p1
PRODUCTION&TECHNICALTOURINGINFORMATION
Egg
Aco-productionbetweenMelbourneTheatreCompanyandTerrapinPuppetTheatre.
Note:thesespecificationsarebasedontheoriginalseasonandaresubjecttochangeduringremount.
Egg TechnicalSpecifications(June2017) p2
TABLEOFCONTENTS
1. SET .................................................................................................... ERROR! BOOKMARK NOT DEFINED.
2. VENUEREQUIREMENTS .................................................................................................................................... 6
2.1 GENERALSTAGEDIMENSIONS ...................................................................................................................... 62.2 PROSCENIUMDIMENSIONS .......................................................................................................................... 62.3 LOADINGDOCK ............................................................................................................................................. 62.4 STAGESURFACE ............................................................................................................................................ 62.5 FLYINGSYSTEM ............................................................................................................................................. 62.6 RIGGINGREQUIREMENTS ............................................................................................................................. 62.7 ACCESSEQUIPMENT ..................................................................................................................................... 62.8 MASKING ...................................................................................................................................................... 72.9 STORAGE ....................................................................................................................................................... 72.10 FOHCONTROLPOSITION ......................................................................................................................... 72.11 DRESSINGROOMSANDOFFICES ............................................................................................................. 72.18 BUMP-IN .................................................................................................................................................. 72.19 BUMP-OUT ............................................................................................................................................... 7
3. ENVIRONMENTHEALTH&SAFETY .................................................................................................................. 8
3.1 RISKASSESSMENT ......................................................................................................................................... 83.2 SPECIALPERFORMANCECONDITIONS .......................................................................................................... 8
4. SCHEDULE .......................................................................................................................................................... 8
4.1 PRERIG ......................................................................................................................................................... 84.2 BUMP-IN ....................................................................................................................................................... 94.3 BUMP-OUT ................................................................................................................................................... 9
5. SET/STAGING ................................................................................................................................................ 10
5.1 GENERALSETDESCRIPTION ........................................................................................................................ 10
6. LIGHTING ......................................................................................................................................................... 11
6.1 GENERAL ..................................................................................................................................................... 116.2 LIGHTINGPOSITIONS .................................................................................................................................. 116.3 LIGHTINGDIMMERS ................................................................................................................................... 116.4 LAMPCOUNT .............................................................................................................................................. 116.5 PROVISIONALLANTERNLIST: ...................................................................................................................... 116.6 LIGHTING–SETELECTRICS .......................................................................................................................... 116.7 LIGHTINGDESK&OTHER ............................................................................................................................ 12
7. SOUND ............................................................................................................................................................. 12
7.1 GENERALOVERVIEW .................................................................................................................................. 127.2 SPEAKERS .................................................................................................................................................... 127.3 FOHCONTROL ............................................................................................................................................. 127.4 PLAYBACK ............................................................................................................................................... 127.5 MICROPHONES ....................................................................................................................................... 137.6 APRA MATERIALS .................................................................................................................................. 13
8. COMMUNICATIONSANDVIDEO .................................................................................................................... 14
8.1 COMM’S CHANNELS .............................................................................................................................. 148.2 RADIOORHARDWIREDCOMM’SALLOCATIONS ......................................................................................... 148.3 ADDITIONALPRODUCTIONDESKREQUIREMENTS ..................................................................................... 148.4 MASTERPANEL/STAGEMANAGEMENTDESK ........................................................................................... 148.5 CUELIGHTS ................................................................................................................................................. 14
9. PROPSANDFURNITURE ................................................................................................................................. 14
9.1 GENERALOVERVIEW .................................................................................................................................. 14
Egg TechnicalSpecifications(June2017) p3
10. WARDROBE ..................................................................................................................................................... 14
10.1 FACILITIESREQUIRED ............................................................................................................................. 1410.2 WARDROBEMAINTENANCE .................................................................................................................. 15
11. POWER ............................................................................................................................................................ 15
11.1 LIGHTINGANDSOUND ........................................................................................................................... 1511.2 GENERALPOWER ................................................................................................................................... 15
12. GREENROOMREQUIREMENTS ...................................................................................................................... 15
12.1 DRINKINGWATER .................................................................................................................................. 1512.2 GREENROOMREQUIREMENTS .............................................................................................................. 15
13. CLEANING ........................................................................................................................................................ 15
14. SECURITY ......................................................................................................................................................... 15
15. FOHINFORMATION ........................................................................................................................................ 15
17.1 RUNNINGTIMES .................................................................................................................................... 1517.2 LATECOMERSENTRY .............................................................................................................................. 1617.3 FOHWARNINGS ..................................................................................................................................... 16
AdditionalDocumentstothisinformation,tobeprovidedseparately:a.ProductionSchedule–venuespecificb.FloorPlanc.LightingPland.RiskAssessmentandMSDSse.FOHInformationSheet
Egg TechnicalSpecifications(June2017) p4
1. SET
Egg TechnicalSpecifications(June2017) p5
Egg TechnicalSpecifications(June2017) p6
2. VENUEREQUIREMENTS
2.1 GENERALSTAGEDIMENSIONS
The show requires aminimum stage depth of 7000mm from the setting line and an idealwidth ofwalltowall,and9000mmstagewidthbetweenmaskinglegs.TheProduction requires a completely clear stage, and request that backstage and loadingdock areclearfromthecommencementoftheBump-in.StandardLegsandBorderswillbeutilisedifperformedinaProsceniumArchvenue.AblacksmotherisrequestedUSoftheset.Preferreddepthis7000mmfromSettingLinealthoughbetween7000mmto11000mmUSofthesettinglineisacceptable.TheentirestageareaMUSTbeclearofallitems–includingbins,ladders,EWP’sandlightingracks.
2.2 PROSCENIUMDIMENSIONSTheoriginalproductionwasperformedintheSouthbankTheatre,LawlerStudio–ablackboxstudiowithtieredseatinginanendonconfiguration.Therequiredminimumprosceniumopeningforthisproductionis:Width: 7,800mmHeight: 5,000mm
2.3 LOADINGDOCKTheProductionrequiresminimumdimensionsforthedockdoorof:Width: 850mmHeight: 2000mmAccesstotheloadingdockmustbelevelandwithoutanyobstacles.Itispreferablefortheloadingdocktobeatstagelevel.
Thesettravelsin1x3Tonnetruck.
2.4 STAGESURFACETheVenue’sstagesurfacemustbecleanandlevel.Terrapinmustbeabletoaffixtothestagefloorusing20mmtechscrewsorsimilarmeans.
2.5 FLYINGSYSTEMThereisnoflyingduringtheperformance.
2.6 RIGGINGREQUIREMENTSTheArch/Slashcurtainisriggedwithtwo(2)dropperstokeepitvertical;howeverthesetpieceisgrounded,andremainsstaticfortheentireperformance.Itissecured(screwed)tothefloorateitherendanddoesnotneedtobeflownatanystage.Droppersandreutlingercablegripstobesuppliedbytouringcompany.
2.7 ACCESSEQUIPMENTTheVenueisexpectedtosupplysuitableaccessequipmentwhichmustbeinfullworkingorder.1xSinglePersonElectricLiftrequiredwithreachtolightingpositionsrequiredforlightingfocus.
Egg TechnicalSpecifications(June2017) p7
2.8 MASKINGAllMaskingprovidedbyvenueandshouldbeinplacepriortoscheduledbump-in:
VenuestandardconfigurationofBlackWoolBorders–whereapplicableConfigurationofBlackWoolLegsasperHangingPlot1xBlackWoolSmotherisrequiredupstageofset.SeeHangingPlot
2.9 STORAGETheremustbesufficientroomforstorageoftheProduction’spropscases,toolcrates,etc.orwithincloseproximityofthestagearea,butnotinthestagearea.Ifstorageisnotavailableparkingfor3Tonnetruckshouldbeeasilyaccessiblefromthestage.
2.10 FOHCONTROLPOSITIONAudioplaybackincludingmixing,musicandsoundeffectsisoperatedbytheTouringTechnicianfromaFOHcontrolposition.LightingiscalledbytheTouringStageManagerandoperatedbytheTouringTechnicianfromFOHpositonsuchasvenuecontrolroom,unlessthereisinsufficientroomavailabletoaccommodatethetouredlightingdeskinwhichcaseanalternativeoperatingposition,suchasrearofauditorium,willneedtobearranged.
2.11 DRESSINGROOMSANDOFFICESTheProductionrequiresthefollowingofficesanddressingrooms:
1xMaleDressingroom(for1xMalecast)1xFemaleDressingroom(for2xFemalecast)Thedressingroomsmustbeequippedwithappropriatetables,chairs,mirrors,etc.withaccesstotoiletsandshowers.Ifpossiblethefollowingfacilitieswouldbeappreciated:1xStageManagementOfficewithinternetfacilities;printerandtelephone1xfullyequippedLaundryincludingwashingmachine,tumbledryerandDryingCupboard
2.12 BUMP-INStaffingfortheBump-inisshownintheProductionSchedule,sendasattachment,orrefertosection4.2ofthisdocumentforasummary.Themajorityofbump-intasksaredepartmentspecifichoweverwerequireassistancefromallrosteredvenuestafftoassistwithunloadingthetruckandassemblingtheset.ManualHandlingrequirementshavebeenminimisedasmuchaspossiblewithinthedesignandconstructionoftheset,whichisasimplebolttogetherassembly.
2.13 BUMP-OUTForstaffing/timerequirementspleaserefertofullProductionscheduleorsection4.3ofthisdocumenttoviewasummary.Asperbump-inrequirements,venuestaffarerequiredtoassistwithbasicmanualhandlingtasksandunloading/loadingthetruck.
Egg TechnicalSpecifications(June2017) p8
Pleasenote:thisbump-outallocationdoesnotallowforfullLx/Audioresettovenuestandard.Pleaseallowforthisaspervenuerequirements.
3. EnvironmentHealth&Safety
3.1 RISKASSESSMENTTheRiskAssessmentfortheproductionisaseparatedocument,sentasanattachment.
3.2 SPECIALPERFORMANCECONDITIONSTherearenospecialperformanceconditionsforthisproduction.AnMSDSareavailableforitemscoveredwithintheriskassessmentincludingArrowrootpowder(a.k.aTapiocaflour).Afewhandfulsofwhite“snowlike”confettiisused,manuallythrownintheairbycastonstage.MSDSfortheArrowrootpowderisavailable,sentasanattachment.
4. SCHEDULE
4.1 PRERIGAfullLighting,Audioandsoftmaskingprerigisrequired–forfixturestobecolouredandflashedpriortodesignatedbump-in.WithSufficientR119andR132FrostavailableatFocus.GelcolourtobeprovidedbyVenues.
Venuetoconfirmtimeandstaffingtoachievepre-rigrequirements
Lighting:LxPreRig,colour,flashandhavepatchsheetsavailablefortouringstaff.SetLxbarsto6.3m(preferredheight–tobar).N/Aforfixedgridvenues.SinglerunPowerandDMXtoMSPSforLEDcontrollers(pracunits)7DimmablecircuitsavailableUSPSforSetLX
Staffingaspervenuerequirements
Audio:- Prepareaudiooutputsandinputsaslistedin
section7.4ofthisschedule- PowersupplyrequiredforTouringAudio
equipment(QLABcomputer)atStageManagementDesk:(PromptcornerorFOHControldependentonvenueconfiguration)
- Positionpatchandtest2xspeakersonstage,USPSandUSOP.
- HeadsetsrequiredforSM,LightingOperatorandDutyTechnician.
Staffingaspervenuerequirements
Masking:Hangallsoftmasking:LegsandbordersasperhangingplotRearsmother:Ifavailable–tabswithcentersplitpreferredasUSsmother.
Staffingaspervenuerequirements
Egg TechnicalSpecifications(June2017) p9
4.2 BUMP-INTobeusedasaguideonly,andissubjecttochange.Avenuespecificschedulewillbeprovidedtotakeintoaccountvenueminimumstaffinglevels.
Duration Task
2hrs UnloadTruck/SetBump-inandMark-up
1.5hrs Installtouredtechnicalequipment
4to4.5hrs LightingFocus
3hrs LightingandAudioPlotting
Bump-inStaffingrequirements:1xDutyTechnician 11hours1xLightingSupervisor 11hours1xElectrics 4.5hours1xAudio 6.5hours(splitshift)Note:ElectricsandAudiopositionscanbecombinedtosameindividualifmulti-skilledtechnicianisavailable.
Showcrew:– 1xStageManager 1xLightingOperator/TouringTechnician
1xDutyTechnician
4.3 BUMP-OUTTheBump-outwilltakeapproximately2to3hoursasitallowstimeforpartialwardrobemaintenancetobecompletedpostshow.Thebump-outwilltypicallycommencefollowingtheendofthefinalperformancewithouttheneedforamealbreakpostperformance.1xDutyTechnician 3hours1xElectrics/Audio 3hoursPleasenote:Thistimeallocationisindicativeoftimerequiredfortheproductiontopack-upandloadout.Itdoesnottakeintoaccounttimerequiredforvenuerequirementssuchreinstatingvenuestandardconfigurations.Additionaltimeshouldbeallowedforthisbythevenueaccordingtovenuerequirements.
Egg TechnicalSpecifications(June2017) p10
5. SET/STAGING
5.1 GENERALSETDESCRIPTIONTheSETforEggconsistsofanArchwaywithSlashCurtain,agroundrowreferredtoasthePlayboard,andmultipleplyshapesthatassembletobecometheEggTree.Theproductionalsocontainspuppets,aslistedbelow,andaseriesofpropsincludingjewellery,silverware,millinery,eyewear,oldfashionedtoolsanddomesticitems.Furtherdescriptionoftheindividualitemsislistedbelow:ArchwithSlashCurtain:Anarchwayconstructedfromasteelframe,cladwithply.Thearchsitsonthefloorateitherside,butiskeptverticalviatwoSWRdroppers.100mmwidestripsofpvcandplasticfabricsareattachedtoplycoversthatboltontotheUSfaceoftheArch.Playboard:Atimberframed,plycladgroundrowset850mmdownstageoftheArch/SlashCurtain.ItisusedasaperchforthepuppetsandhasadditionaltwodimensionalshapesmadeofplythataremountedonthebackofthePlayboardtowhichslideupanddowntobeinoroutofview.EggTree:MadefromsevenindividualpiecesofvaryingshapesthatassembletogetherviaspigotsandsleevestomaketheEggTree.PiecesareregisteredwithLettersAtoHalthoughpieces“E”and“D”arepermanentlyjoined.Whenassembled,thesurfaceofonesideofthetreeisflatply,thereversesidehas2.5dimensionaldetailingtogivetheimpressionofeachpiecebeingabuildingwhichisdisplayedwhenpiecesareseparated.Additionalfeaturesexistinthefollowingpieces:
- PieceA:Containsaretractablerollerblind(notusedintheshow)- PieceB:Hasa removable lid (attachedwithmagnets)which isdressedwithpracticalprops.
The inside of the box is also dressed with “precious things” that are mostly non-practicalprops.Setelectrics,comprisingofLEDstrip,batteryandpressureswitchwhichactivatesthelightsourcewhenthelidisremoved,arefittedwithinthispiece.
- PieceF:Hasahingedsidewhichopens to reveala lightbox.This isused to revealabacklitusedasanX-Rayof theOvopuppet. Therefore the contentsof thispiece includeLED strip,batteryandpressureswitchwhichactivatesthelightsourcewhenthelidisopened.
Puppet-Ovo:Ahand-madepuppetthatappearsasagrub-likecreaturewithalargeface,operationalbeak,multiplelimbs(twoofwhichareoperational),asmoothfrontandafurcoveredback.TheOvopuppetisextendableto“grow”inlength,hasextendableantennaandasetofwingsthatisaseparatepiecebutattachestoits’backplate.Puppet–Egg:Alarge“nest”forOvo,muchlikeacocoon.Madefromvariousrecycledmaterialsithasasoftinteriorandtexturedfabricouterlayertowhichvarious“foundobjects”areattached.ThisEgghasaslitatthebasetoallowthepuppettobetakenin/out,andisdraggedalongthefloorbutaropeandcarabiner.ThisEggalsodoublesasatravelcasefortheOvopuppettoofferprotection.Puppet–PartialEgg:thisisa1/3versionofthefullEgg,representingit“underconstruction”.Itisalsoreferredtoasthe“Brokenegg”asitsplitsapartinordertobeputbacktogetherduringthecourseoftheshow.Theslitsaresecuredtogetherviauseofmagnets.Puppet–Tinkerfigures:SmallwoodenreplicasoftheTinkercharacters.Thesehaveatrigger-actionoperationwhicharticulatethearmsandlegstoachieveawalkingaction.OtheritemsareusedinconjunctionwiththeTinkerpuppetstorepresentotherfullsizepropsintheshowincludingtheEggandoversizedbackpack.
PleaseviewFloorPlan,sentasanattachment.
Egg TechnicalSpecifications(June2017) p11
6. LIGHTING
6.1 GENERAL- AllDRAFTlightingpositionsandfixturerequirementsaredetailedintheLightingequipmentlist
below.- Otherthantouredsetelectrics,alllightingfixturesutilizedwillbefromvenuestockequipment.- A lighting plan will be supplied to confirm required placement of fixtures to be used in the
production.- The Production requires control of the Venue House Light system from the Lighting Console
position. It should be dimmable, and fade times adjustable to suit the Lighting Designrequirements.
- WorklightsshallbemadeavailableonthedayoftheBump-in.- Bluelightshouldbeavailableforbackstageareasduringperformancemode.
6.2 LIGHTINGPOSITIONSFOH:Forfrontwash/Specials.Boxboomswillbeusedforspecialswhereavailable.OnstageLightingpositions:includelightingbarsoverheadandsix(6)booms,3perside.Pleasenote:BorderdeadstosuitLxBarsat6.3m(toBarheight)Note:N/Aforfixedgridvenues.
6.3 LIGHTINGDIMMERS55x2kW(including19xFloorCircuits)ThiscountexcludesHouseLights.
6.4 LAMPCOUNTTotalLampCount Approx63Units(excludingsetelectrics)–
Usethisasaguideonly,thiswillvaryfromvenuetovenue.
6.5 PROVISIONALLANTERNLIST:
ThislistisnominatedastheGenerictourremount,nottheoriginalMelbourneproduction.PleaseseeVenuespecificLXplanforconfirmedfixtures.
6.6 LIGHTING–SETELECTRICSThefollowingSetelectricsaretoured-
OBJECT PLACEMENT NOTES
5xLEDsourcesUSofPlayboard,mountedtoset
GroundrowandspecialsforArchandSlashcurtain
Bulbs-7DimmableCircuits MountedonArch FeaturelightsBatteryOperatedLEDStrip OnProps
TYPE WATT BEAMANGLE NOTES TOTALFresnel 1.2Kw 22Fresnel 650w 8Par64 5ProfileS4 750 25-50 28Boompipe(3m)andbases
6
Egg TechnicalSpecifications(June2017) p12
Allsetelectricsarelowvoltageandconnecttotransformersfor240Vpower.2xpowercircuitsrequiredand1xDMXcableonaseparateuniverserequiredtobesuppliedbyvenuetoonstagepositionforthis,locatedUSPSoftheset.
6.7 LIGHTINGDESK&OTHERThetouredlightingdeskrequiresaDMXoutputtoconnecttohousesystem.TheproductionwasoriginallyprogrammedonanETCIonlightingconsole.Colourcutlistwillbeprovidedwiththevenuetosupply.Substitutionstocolourmaybemadeasrequired,pleasecontacttheTouringTechniciantodiscusssubstitutionswhererequired.PleasenotethataLightingpre-rig(includingcolour,patch,flashthroughandtroubleshootandsupplyofDMXandpowerforonstagesetelectricsisessentialtothesuccessoftheproduction.AlltouringelectricalequipmenthasbeenTested&TaggedtoAustralianStandard:AS3760
7. SOUNDAllSoundrequirementsaredetailedintheSoundequipmentlistsetoutbelow.
7.1 GENERALOVERVIEWTheProducer/VenueistoprovideahighqualityPAabletoproduce110dBundistortedsignalatmixposition.TheProducer/Venuewillalsosupplyallnecessaryrigging.
7.2 SPEAKERSFOHPAsystemshallbeusedateachvenue.Ideallythisshallinclude:- FOHLFullrangeFOHPASpeaker- FOHRFullrangeFOHPASpeaker- Subs- 1StageSpeakerUSL.- 1StageSpeakerUSR.- WirelessspeakerwornbyPuppeteer(Toured)
Thepresenterwillsupplycablesforaudiopatchingrequirements.
7.3 FOHAUDIOCONTROLAudiowillbeoperatedbytheTechnicnafromFOHposition.ItCANNOTbebehindanywindows.
7.4 PLAYBACKTheaudioplaybacksystemwillbetoured.ItwillbeoperatedbytheTouringStageManager.ThesettingofallamplificationlevelsshallbeatTerrapin’sdiscretion,butwillnotexceedthelimitsdefinedbyAustralianEH&Sregulations.Theaudioplaybacksystemcomprisesof:
Egg TechnicalSpecifications(June2017) p13
MTCTouringAudioRackContentsItem DescriptionPlaybackComputer AppleMacMinii7dualHD–Keyboard,Mouse,GObuttonandMonitorincludedPlaybackSoftware QLab3.1.23SoundCard RMEFireFaceUCX–6BalancedTRSJackout–1xStereoUn-balancedoutIEM SennheiserEW300G3IEMSystem–1Ch:566.450MHzMulti-Core 8wayBalanced3pinXLRoutputs(1.2mlong)CueLights Custom12VDCCuelightsystem(willtourwith2x20mXLR)PatchingRequirementsOutputsfromMTCTouringAudioRackEquipmentsource
Output ChannelDescription
Destination Supplier ConnectionType
RMESound 1 FOHLeft VenueFOHMixer MTC BalancedXLRRMESound 2 FOHRight VenueFOHMixer MTC BalancedXLRRMESound 3 Subs(MONO) VenueFOHMixer MTC BalancedXLRRMESound 4 USLeft VenueFOHMixer MTC BalancedXLRRMESound 5 USRight VenueFOHMixer MTC BalancedXLRRMESound 6 OVO IEMTransmitterinRack MTC BalancedXLROUTPUTSFROMVenueFOHMixingConsoleEquipmentsource
ChannelDescription
Destination Connections Supplier Notes
VenueFOHMixer FOHLeft VenuePAFOHLeft BalancedXLR Venue VenueFOHMixer FOHRight VenuePAFOHRight BalancedXLR Venue VenueFOHMixer Subs VenueSubs BalancedXLR Venue VenueFOHMixer USLeft USOPonFloorDSofArch BalancedXLR Venue RCF310A’sor
equivalentVenueFOHMixer USRight USPSonFloorDSofArch BalancedXLR Venue RCF310A’sor
equivalentOTHEREquipmentSource
ChannelDescription
Destination
Supplier ConnectionType
Note
CueLightsystem Cuelight USPS MTC/Venue BalancedXLR Directtieline,donotpatchthroughDSPoranyotherprocessingsystem
7.5 MICROPHONESSMshoutmicrequiredinpromptcorner/FOHcontrolforFOHannouncements.Terrapinwilltourwirelessradiomicsfortheperformers.
7.6 APRAMATERIALSTherearenoAPRAmaterialsrequiredtobelicensedforthisproduction.Allaudio/soundmaterialisoriginalcontentcomposedforthisproduction.
Egg TechnicalSpecifications(June2017) p14
8. COMMUNICATIONSANDVIDEOTheProductionrequiresaperformancecommunicationssystemtobeprovidedwhichincludes:
8.1 COMM’SCHANNELS1. AudioandLighting
8.2 RADIOorHARDWIREDCOMM’SALLOCATIONS1. 1xSM 1set
Note:wirelesspreferred,otherwiselongleadrequired)2. 1xLightingOperatorheadset 1set3. 1xDutyTechnician 1setTOTAL 3Sets
8.3 MASTERPANEL/STAGEMANAGEMENTDESKThemasterpanelforcommunicationsshouldbelocatedattheSMpositioninpromptcornerorFOHcontrolaspervenueconfiguration.Venuemustalsoprovidethefollowing;
- 1xFOHvideofeedoffullstageshotincolour.Anadditionalinfraredfeed/monitorrequestedifavailable(N/AifSMpositionedFOH)
- Abackofhousepagingsystemwithcompletecoverageofallbackstageareas.- Abackofhouseprogramfeedwithcompletecoverageofallbackstageareas.AllequipmentsuppliedbytheVenuemustbesuppliedandmaintainedattheexpenseoftheVenue.
Pleasenote:SMpositioncanbefromFOHinnon-prosceniumarchvenues(e.g.EarlArtCentre).VideofeedisnotrequiredifSMhasfullviewofstagefromcallingposition.
8.4 CUELIGHTSCuelightsystemwillbetoured:Twocuelightsarerequiredfortheproduction.RequestforXLRcabletobeprovidedfromvenuestock–torunfromPromptcorner/controlpositiontoUSPS.CUELIGHTPLACEMENT
1. 1xUSPS(visiblefromUSofArch/Slashcurtain2. 1xCastentrancetostage(specificallyrequiredifSMlocatedFOH).
9. PROPSandFURNITURE
9.1 GENERALOVERVIEWPleaserefertosection5.1fordescriptionofEggTreeandpuppetsfeaturedinthisproduction.Otherwisesmalltouringpropsitemsinclude:
Anoversizedbackpack,jewellery,silverware,eyewear,oldfashionedtools,papiermacheeggs,kitchenimplementsanddomesticitems.
10. WARDROBE
10.1 FACILITIESREQUIREDTheProductionrequiresthefollowinglaundryequipment;
Egg TechnicalSpecifications(June2017) p15
1xWashingmachine1xDryingRoomorDryingCabinet1xTumbledryer1xIronandIroningboard
10.2 WARDROBEMAINTENANCEWardrobemaintenanceshallbecompletedbytheStageManager.
11. POWER
11.1 LIGHTINGANDSOUNDThepowersupplyforLightingshallbeseparatetothepowersupplyoftheSoundsystem.
11.2 GENERALPOWER2x240volt10ampGPO’sfortoolsandotherequipment.
12. GREENROOMREQUIREMENTS
12.1 DRINKINGWATERPleaseprovideaccesstofiltereddrinkingwater.
12.2 GREENROOMREQUIREMENTSIfpossible,pleaseprovideteaandcoffeemakingfacilitiesfortheCompanyincludinggroundcoffee,teabags,sugar,andfreshmilkperperformance,cupsormugs,spoonsetc.
Arefrigeratorwithafreezercompartment(foricepacks)isrequiredaswellasrunningwater.
Accessto1microwaverequestedifavailable.
13. CLEANINGThe Production requires the use of one (1) good quality vacuum cleaner, preferably a back packvacuumcleaner.
14. SECURITYFromthecommencementoftheBump-inuntiltheconclusionoftheBump-out,theVenuewillsupplyadequatesecurity forallequipment, sets,propertiesandpersonalbelongings fromthebeginningoftheBump-inuntiltheconclusionoftheBump-out.
15. FOHINFORMATION
15.1 RUNNINGTIMESApproximaterunningtimeis1hourwithoutanintervalHouseopens: 15minutespriortoperformancecommencing.
Egg TechnicalSpecifications(June2017) p16
15.2 LATECOMERSENTRYTheperformancecanbeheldfor2minutestoreducetheamountoflatecomersifrequired.
PleaseseeFOHinformationsheet,sentasattachmentforlatecomer’sentrypoints.
Ifpossible,itispreferredforanylatecomerstobeseatedattherearoftheauditoriumtoreducethedisruptiontootheraudiencemembers.
15.3 FOHWARNINGSNouseofmobilephonesandnophotographypermitted.