Getein1600 Immunofluorescence Quantitative Analyzer
WPT3-16-01
Add: No.9 Bofu Road, Luhe District, Nanjing, 211505, China Tel: +86-25-68568594; 68568508; 68588528Fax: +86-25-68568500E-mail: [email protected]; [email protected]: www.bio-GP.com.cn
10 min
10 min
10 min
15 min
15 min
3 min
cTnI
NT-proBNP 100~35000 pg/ml
hs-CRP+CRP
2.5~80.0 ng/ml
0.1~50.0 ng/ml
30~600.0 ng/ml
CK-MB/cTnI/Myo
5 ng/ml
0.1 ng/ml
70 ng/ml
0.1 ng/ml
0.1 ng/ml
3 mg/L
0.5 mg/L
10 mg/L
300 pg/ml
0.5~200.0 mg/L
0.1~10.0 mg/L
0.1~50.0 ng/ml S/P/W.B
S/P/W.B
S/P/W.B
S/P/W.B
P/W.B
S/P/W.BFingertip Blood
0.1~50.0 ng/ml
Cardiovascularinflammatory
diseases;Inflammatory
disorders
45kg
639mm×562mm×728mm (D×W×H)
10,000 data (Max)
AC100V~AC240V, 50Hz~60Hz
Up to 48 samples per run, continuous sample loading for different test items
Whole blood, plasma, serum, urine, fingertip blood
LCD screen: 10.4 inch; Resolution: 800×600
Internal thermal printer
Relative humidity ≤70%, Air pressure 70.0kpa~106.0kpa
English/Chinese(Spanish, French, German, Russian, Arabic, Vietnamese ,etc are under developing)
Lateral Flow Chromatography (Immunofluorescence)
Quantitative
Assay Method
Test Result
Throughput
Sampling Material
Language
Display
Printer
Working Environment
Power Supply
Storage Capacity
Dimensions
Weight
Getein1600 Test Items
Technical Data
Test Item Disease MeasuringRange Sample Cut-off
ValueReaction
Time
Myocardialinfarction
Heart failure
Myocardial injury
Venousthromboembolism;
Pulmonary embolism
Sepsis;Septic shock
D-Dimer
PCT
Select testing items Fully automatic detection Results saved andprinted automatically
Turn on & Enter testing interface Load original sample tubes Insert ready-to-usestrip cassettes
Test Procedure
New benchmark for the development of POCTTo meet multiple needs of emergency, central laboratory
Traditional POCT VS Automatic POCT
Traditional POCT
Operation
Stability of Results
Detection Efficiency
Detection Standardization
Detection Cost
Automatic POCT
Time-consuming, Manual operation, Human fallibility
Fully automatic processing avoids inaccurate results of manual operation
Susceptible to human factors
Relatively low
Not easy to standardize management
Relatively high
Relatively high
Facilitate standardization management
Relatively low (save labor cost)
Stable
Getein�1600
High throughput, On-site testing, Quick access to test reports
Traceability of report results Easy sample collection and operation, minimal training required
Automatic test and less manual intervention from loading to results.
Multiple measures to ensure accurate and reliable test results
Automatic pipetting system, disposable tip with filter to prevent cross-contamination
Easily achieved laboratory standardization
Up to 48 samples per run, continuous sample loading for different test items
Automatic barcode scanning & RFID card recognition to ensure the traceablility of test results.
Maximum 150 tests per hour,the average detection time≤30s per sample
IVDIVD
Quick�and�easyLow�
comprehensive�cost
High�efficiency Less�dosage�
of�samples
Stable�reagents�
for�storage
Perfect after-sale service
Professional technical team
Perfect manufacturer and agent service
Fully-automatic detection& sample loading, standard sop file equipmented, according to regulatory requirement for clinical laboratory standards
Emergency mode: emergency samples can be tested at anytime
User-friendly interface, real-time monitoring of each sample
Visually reagent interface, convenient inventory management
LIS/HIS connectivity, convenient sample management
Liquid auto-induction
Automatic calibration, dilution, loading
Fully-automatic quality control
The Inevitable Development of POCT Performance Optimization and Micro Automation