- The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
PAGE 1 OF 13
Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT
Number: HK11110992-1(R1) Date: 18 January 2012
Applicant: PKG Max-Life PO BOX 179, KUMEU, AUCKLAND, NEW ZEALAND This report supersedes the previous
report HK11110992-1 dated 23 December 2011.
Sample Description Product : AA ALKALINE BATTERIES Brand Name : MAX-LIFE/ DURACELL/ EVEREADY/ ENERGIZER/ PANASONIC Model No. : MAX-LIFE – ALKALINE AA DURACELL – COPPERTOP AA EVEREADY – GOLD ALKALINE AA ENERGIZER – MAX ALKALINE AA PANASONIC – ALKALINE AA Electrical Rating : 1.5V No. of Samples : 9 (Nine) per brand Date Received : 24 November 2011 Date Test Conducted : 24 November 2011 to 15 December 2011 Test Requested : IEC 60086-1: 2011
1. Clause 4.2.1 - Discharge Performance AA type battery discharge performance test for an application of Digital still camera.
Test Method : IEC 60086-1: 2011 in conjunction with IEC 60086-2 Test Results : See the attached sheets Conclusion : See the attached sheets Remark : When determining the test conclusion, the Measurement
Uncertainty of test has been considered.
********************************************* End of Page *********************************************** Reviewed by : ____________________ Kong Ka Hang, Felix Assistant Manager
PAGE 2 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) A COMPARISON MATRIX FOR DIFFERENT BRANDS Test result:
Average Discharge Duration Time (pulses) Brand Application of Digital still camera
MAX-LIFE 55 DURACELL 54 EVEREADY 41 ENERGIZER 63 PANASONIC 89
*********************************************** End of Page ************************************************
PAGE 3 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) 1. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: MAX-LIFE
Datecode: APR 2014
Sample Number
Discharge Duration Time (Pulses)
1 54 2 54 3 56 4 57 5 53 6 56 7 56 8 57 9 56
Average: 55 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. *********************************************** End of Page ************************************************
PAGE 4 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) 2. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: DURACELL
Datecode: MAR 2017
Sample Number
Discharge Duration Time (Pulses)
1 59 2 57 3 57 4 56 5 57 6 55 7 57 8 46 9 47
Average: 54 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. *********************************************** End of Page ************************************************
PAGE 5 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) 3. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: EVEREADY
Datecode: 03-2016
Sample Number
Discharge Duration Time (Pulses)
1 45 2 43 3 46 4 39 5 36 6 39 7 45 8 35 9 45
Average: 41 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. *********************************************** End of Page ************************************************
PAGE 6 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) 4. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: ENERGIZER
Datecode: 03-2018
Sample Number
Discharge Duration Time (Pulses)
1 64 2 63 3 63 4 69 5 65 6 63 7 64 8 57 9 59
Average: 63 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. *********************************************** End of Page ************************************************
PAGE 7 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK11110992-1(R1) 5. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: PANASONIC
Datecode: 08-2017
Sample Number
Discharge Duration Time (Pulses)
1 88 2 88 3 89 4 96 5 89 6 96 7 86 8 87 9 88
Average: 89 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. *********************************************** End of Page ************************************************
PAGE 8 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Marking Number : HK11110992-1(R1)
Max-Life
*********************************************** End of Page ************************************************
PAGE 9 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Marking Number : HK11110992-1(R1)
Duracell
*********************************************** End of Page ************************************************
PAGE 10 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Marking Number : HK11110992-1(R1)
Eveready
*********************************************** End of Page ************************************************
PAGE 11 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Marking Number : HK11110992-1(R1)
Energizer
*********************************************** End of Page ************************************************
PAGE 12 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Marking Number : HK11110992-1(R1)
Panasonic
*********************************************** End of Page ************************************************
PAGE 13 OF 13 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK11110992-1(R1)
Max-Life Duracell