13
Report #: 2088-1 Page 1 of 12 The Compliance Management Group 202 Forest Street Marlborough, MA 01752 (P) 508-281-5985 www.cmgcorp.net (F) 508-281-5972 Test Report #: 2088-1 Date: July 1, 2005 Issued To : William Hammond American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Uninterruptable Power Supply Model Number SUA2200JB Serial Number(s) YS0427122760 Product Test Standard APC Design Standard Test Description Generated Magnetic fields Test Dates May 18, 2005 Test Engineer(s) Adam Chubka Test Results N/A Prepared By: ______________________ Reviewed By: ______________________ Ron Leczynski Mike Morrow Senior EMC Engineer VP of Engineering and Operations This test report shall not be reproduced, except in full, without the written approval of The Compliance Management Group.

Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Embed Size (px)

Citation preview

Page 1: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 1 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

Test Report #: 2088-1

Date: July 1, 2005

Issued To:

William Hammond American Power Conversion

85 Rangeway Road North Billerica, MA 01862 USA

978-670-2440

Product Name/Description Uninterruptable Power Supply Model Number SUA2200JB Serial Number(s) YS0427122760 Product Test Standard APC Design Standard Test Description Generated Magnetic fields Test Dates May 18, 2005 Test Engineer(s) Adam Chubka Test Results N/A

Prepared By: ______________________ Reviewed By: ______________________

Ron Leczynski Mike Morrow Senior EMC Engineer VP of Engineering and Operations

This test report shall not be reproduced, except in full, without the written approval of The Compliance Management Group.

Page 2: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 2 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

TABLE OF CONTENTS

Title Page SECTION 1 OVERVIEW .................................................................................................................................................. 3

1.1 PURPOSE OF TEST ......................................................................................................................................................... 3 1.2 DATES OF TEST............................................................................................................................................................. 3

SECTION 2 REFERENCES .............................................................................................................................................. 3 2.1 PROCEDURES/STANDARDS ........................................................................................................................................... 3

SECTION 3 DETAILS ....................................................................................................................................................... 3 3.1 DESCRIPTION OF PRODUCT........................................................................................................................................... 3 3.2 TEST SOFTWARE/OPERATING MODE............................................................................................................................ 3 3.3 LABORATORY TEST CONFIGURATION .......................................................................................................................... 4 3.4 PICTURES ..................................................................................................................................................................... 5

SECTION 4 CONCLUSIONS............................................................................................................................................ 7 4.1 TEST RESULTS.............................................................................................................................................................. 7 4.2 SPECIAL NOTES............................................................................................................................................................ 7 4.3 REQUIRED COMPLIANCE MODIFICATIONS.................................................................................................................... 7

APPENDIX A EMI EMISSIONS AND IMMUNITY TEST FORM ............................................................................. 8

APPENDIX B COMPLIANCE MANAGEMENT GROUP CREDENTIALS ............................................................... 12

Page 3: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 3 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

SECTION 1 OVERVIEW 1.1 Purpose of Test To determine if the Uninterruptable Power Supply Model SUA2200JB will meet the following

emissions requirements:

APC Design Standard, Generated Magnetic fields, No limits apply. 1.2 Dates of Test May 18, 2005 SECTION 2 REFERENCES 2.1 Procedures/Standards ° APC Design standard Magnetic measurement procedure SECTION 3 DETAILS 3.1 Description of Product The Equipment Under Test (EUT) consisted of a Uninterruptable Power Supply, Model

SUA2200JB. The voltage supplied to the EUT was 100 VAC, 60 Hz. The voltage supplied to the support equipment was 120 VAC, 60 Hz.

The specific EUT information is listed in Appendix A. 3.2 Test Software/Operating Mode:

An Uninterruptible power supply provides backup electrical power during black outs. Full load charging and discharging were the two modes of operation tested.

Page 4: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 4 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

3.3 Laboratory Test Configuration Test Equipment: Magnetic Field Test Equipment Serial # Calibration Due Fischer Custom Communications model MM-1 Magfield Meter 231 12/4/2005 Extech Temp & Humid Meter, Model TH437 (Rock Ridge) EXT006 1/25/06 Fisher Scientific Barometer, Model 14-648-51 (Rock Ridge) 41363306 10/11/05

Note: All calibrations are performed in 12-month intervals. UWCE: Use With Calibrated Equipment

Rock Ridge: Radiated Emissions open area test site. Augusta: A 12 foot wide, 25.5 foot long, 12 foot high chamber with a 12 inch

raised floor. The 4 walls and ceiling are covered with ferrite tile. The floor has a 10 foot by 10 foot ferrite patch that covers the area under the antenna and extends toward the EUT. All power and signal cables are run under the raised floor. An 8 foot wide, 12 foot long, 7 foot high control room is attached to the EUT end. Bulkheads and waveguides are provided to bring cables into the control room. All power entering the two rooms is filtered. The ferrite chamber is calibrated for Field Uniformity.

Pebble Beach: A 9 foot wide, 12 foot long 8 foot high screen room with no ferrite tiles

or absorber cones.

All test equipment used is calibrated and traceable to NIST requirements. Test Environment: Temp.= 22.1°C, Relative Humidity = 38% Barometric Pressure = 100kPa Note: In general, relative humidity levels below 30% represent conditions slightly

more severe than required for some tests (i.e., ESD and EFT).

Page 5: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 5 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

3.4 Pictures

EUT Setup for Generated Magnetic fields X AXIS (Sides)

EUT Setup for Generated Magnetic fields Y AXIS (Front/Rear)

Page 6: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 6 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

3.4 Pictures (continued)

EUT Setup for Generated Magnetic fields Z AXIS (Top/Bottom)

Page 7: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 7 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

SECTION 4 CONCLUSIONS 4.1 Summary of Test Results APC DESIGN STANDARD, GENERATED MAGNETIC FIELDS Test facility used: Rock Ridge

The Measurement of generated magnetic fields at 1 meter distant and also the distant at which point the DC magnetic field drops to 0.5 gauss (Earth’s average magnetic field at sea level) in both directions of X, Y, & Z Axis from the EUT. No limis apply.

The Test was conducted in two modes of operation. EUT at Full Load while connected to the AC mains and Discharging on Battery.

Test Results:

DC Magnetic Field @ 1 Meter from E.U.T.

Axis AC Power Battery Power X (right side) 0.0008 Gauss 0.0022 Gauss X (left side) 0.0009 Gauss 0.0023 Gauss

Y (front) 0.0005 Gauss 0.0013 Gauss Y (rear) 0.0006 Gauss 0.0012 Gauss Z (top) 0.0012 Gauss 0.0026 Gauss

Z (bottom) 0.001 Gauss 0.002 Gauss

Distance from E.U.T. to obtain 0.5 Gauss Axis AC Power Battery Power

X (right side) N/A 4 cm X (left side) 1.5 cm N/A

Y (front) N/A N/A Y (rear) N/A N/A Z (top) N/A N/A

Z (bottom) N/A N/A

N/A: Less than 0.5 Gauss next to EUT 4.2 Special Notes The test engineers were Adam Chubka. The test results set forth in this report are expressly limited to the configuration and tests

herein. Any changes in configuration may void test results. The Compliance Management Group agrees to quote charges for any retesting requested by the customer.

4.3 Required Compliance Modifications None.

Page 8: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 8 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

APPENDIX A

EMI Emissions and Immunity Test Form

CLIENT INFORMATION Customer APC Contact Person William Hammond Telephone # 978-670-2440 xt. 17232 Fax # 978-670-2830 Email address [email protected]

PRODUCT INFORMATION Product Name SmartUPS Model Number SUA2200JB + SUA3000JB Serial Number Dimensions 17” x 20.5” x 8” Weight ≈ 120 lbs. Test Purpose (such as qualify new or modified product)

VCCI-A certification

TEST SETUP INFORMATION Voltage: 100 Current: 30.0 Frequency: 50/60Hz [X ] Single-Phase [ ] 3-Phase Please note any special conditions that would affect product configuration and testing.

TEST SERVICES REQUESTED

Top Level Standard Description Check (if yes)

Emissions Radiated Pre-Scan Engineering evaluation. FCC Part 15 Radio Frequency Devices FCC Part 18 Industrial, Scientific & Medical Equipment ICES-001 Industrial, Scientific & Medical Equipment ICES-003 Digital Apparatus EN55011 Industrial, Scientific & Medical Equipment EN55014 Household Appliances EN55022 Information Technology Equipment (VCCI-A) √ Other Generated magnetic field √ Immunity EN55014 Household Appliances EN55024 Information Technology Equipment EN60601-1-2 Medical Equipment EN61000-6-1 Residential, Commercial & Light Industrial Environment EN61000-6-2 Industrial Environment EN61326-1 Laboratory/Measurement Equipment EN61000-3-2 Harmonics EN61000-3-2 Flicker Other

Page 9: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 9 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

MAGNETIC DEVICES

Are there any magnetic devices in the EUT that may be susceptible to magnetic fields (i.e., magnetic switches or Hall effect sensors)?

PRODUCT DESCRIPTION

(Provide a detailed description of the product under test. What is its function? Describe in adequate detail that an administrator at a government agency can understand)

Uninterruptible power supply, Provides backup electrical power during black outs.

TEST JUSTIFICATION

(If the EUT represents a product family, please explain why this configuration represents the operating mode that should produce the highest emissions while remaining consistent with normal operating conditions.)

PRODUCT [internal] CONFIGURATION INFORMATION Type of Device (such as disk drive, I/O, etc.) Rev Part Number Serial Number Manufacturer & Capacity of

Device

OSCILLATORS & Other Internally Generated Frequencies (such as CPUs, etc.) Frequency Description

16.00MHz xtal CPU clock 24.00MHz xtal CPU clock

NOTE: The highest frequency generated determines the test level.

Page 10: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 10 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

EXTERNAL CABLING INFORMATION

Cable From Cable To Cable Length Part Number # of cable if multiples Description

UNPOPULATED PORTS Port/Device Description/Reason

SUPPORT EQUIPMENT LIST Type of Device

(workstation, keyboard, etc) Part Number Serial Number Manufacturer

Resistive Load Avtron Web Card AP9619 APC

EMISSIONS EXERCISE SOFTWARE DESCRIPTION

(Describe what software is running on the product under test and how it will exercise the system during emissions testing. Include the program cycle time once, in seconds, for all devices to be exercised.)

IMMUNITY EXERCISE SOFTWARE DESCRIPTION

(If different from emissions exercise software. Include the program cycle time once, in seconds, for all devices to be exercised.)

IMMUNITY TESTING PERFORMANCE CRITERIA

(Describe the proper mode of operation of the equipment under test. Explain what the test operator should monitor during the testing to determine if the product is operating within specified parameters)

Page 11: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 11 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

FUNCTIONAL WIRING DIAGRAM OF DEVICE UNDER TEST (to be provided prior to the day of test.)

UPS LOAD

The information contained in this Appendix was provided by William Hammond of American Power Conversion. It contains specific configuration details of the system as tested.

Page 12: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

Report #: 2088-1 Page 12 of 12 The Compliance Management Group ♦ 202 Forest Street ♦ Marlborough, MA 01752

(P) 508-281-5985 ♦ www.cmgcorp.net ♦ (F) 508-281-5972

APPENDIX B

The Compliance Management Group Credentials

BSMI Accreditation No. SL2-IN-E-1125R

Page 13: Test Report #: 2088-1 - - APC USA Report #: 2088-1 Date: July 1, 2005 ... (If the EUT represents a product family, ... determine how good our test reports are,

TEST REPORT POLL

Please rate the attached test report’s quality by responding to the brief questions listed in this poll. Our goal is to provide you with high quality test reports in a timely manner. Therefore, your feedback is vital in order to determine how good our test reports are, and what areas could be improved. Please indicate beside each question what you feel is the rating. Also, feel free to make comments directly on the poll, or by attaching a separate sheet. The completed form should then be returned by either email at [email protected] or FAX to Michael Ryan at 508-281-5972. Your cooperation and effort are truly appreciated. TEST REPORT NUMBER: 2088-1

YES NO 1. Was the information presented clearly?

2. Was the report complete?

3. Was the report timely?

4. Did the report satisfy your requirements?

YOUR NAME (optional): ______________________ Optional Comments: ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

To: Michael Ryan, Program Administrator The Compliance Management Group 202 Forest Street Marlboro, MA 01752

FAX: 508-281-5972