Upload
others
View
17
Download
0
Embed Size (px)
Citation preview
Report No.: 2015A0265
06-999-1110-01 Page 1 of 48
Test Report EMC
Test Laboratory:
Philips (China) investment Co., Ltd. Lighting EMC Laboratory Bld. 9, Lane 888 Tianlin Road
Shanghai Business Park, 200233 SHANGHAI Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected]
Equipment under Test:
Applicant: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI
Manufacturer: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI
EUT: Electronic Ballast
Brand/model: Xitanium 40W 0.35A 115V 230V 10NC:9290 014 029
EUT received: 2015-04-07
Information concerning the Test report:
Report number: 2015A0265
Contact: Mr. Mao, Xiaojun Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected]
Applied standards:
German Standard European Standard IEC/CISPR-Standard DIN EN 55015:2014-03 EN 55015:2013 CISPR 15:2013 + IS1:2013 +
IS2:2013 DIN EN55015:2009-11 EN 55015:2006 + A1:2007 +
A2:2009 CISPR 15:2005 + A1:2006 + A2:2008
DIN EN 61547:2010-03 EN 61547:2009 IEC 61547:2009 DIN EN 61000-3-2:2010-03 EN 61000-3-2:2006 + A1:2009 +
A2:2009 IEC 61000-3-2:2005 + A1:2008 + A2:2009
DIN EN 61000-3-3:2014-03 EN 61000-3-3:2013 IEC 61000-3-3:2013 DIN EN 61000-3-3:2009-06 EN 61000-3-3:2008 IEC 61000-3-3:2008
Remarks to the Standards: None
Result: Pass
Date of issue: 2015-05-11
Tested by:
Mr Yuan Yu
Mr. ZhouWeiping
Reviewed:
Mr. Mao, Xiaojun
Report No.: 2015A0265
06-999-1110-01 Page 7 of 48
5 Test and measuring results
5.1 Disturbance voltage
5.1.1 EN 55015 Disturbance voltage (9 kHz - 30 MHz) at power input
General information about the Test:
Tested by: Mr. Yuan Yu
Test date: 2015-05-06
Instruments: Test site for luminaries Inventory number Description Manufacturer Type
RD-15-0060 EMI Receiver Rohde & Schwarz ESR7 RD-04-0125 Power Source KIKUSUI PCR1000CA RD-18-0027 LISN (for DC Measurement) Schwarzbeck NSLK 8127
Environmental conditions: Rated value Measured value
Ambient temperature: 15 - 25 °C 24 °C
Information concerning the Test:
Test set-up: DIN EN 55015, Clause 8 For built-in appliances the Technical Report CISPR 30(-1 for fluo; -2 for HID)
Operating mode: 1,2
Result: pass
Protocol: See next pages
Report No.: 2015A0265
06-999-1110-01 Page 12 of 48
Philips Lighting Standard Testing Laboratory RFI Voltage Test at Mains Input
Manufacture: Philips Lighting Electronics Test date. 06-May-2015
Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V
Phase L Control number: LED-2015-0164-02
Operating mode: 230V/50Hz Operator: Yuan Yu
Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output
Scan setting:
Frequency Receiver setting
Start Stop Step IF BW detector Meas-time Atten Preamp OpRge
9KHz 150KHz 50Hz 200Hz QP+AV 2 Sec Auto OFF 60dB
150KHz 30MHz 2.25KHz 9KHz QP+AV 2 Sec Auto OFF 60dB
100 kHz 1 MHz 10 MHz9 kHz 30 MHz
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
0.0
120.0
dBμV
Limits
55015MQP
55015MAV
Transducer
8121
Traces
QP
AV
Peak Search Results
Trace Frequency Level Limit Delta Limit Delta Ref Comment
(MHz) (dBμV) (dBμV) (dB) (dB)
* = limit exceeded
Report No.: 2015A0265
06-999-1110-01 Page 20 of 48
5.2 Radiated Magnetic field strength (9 kHz - 30 MHz)
General information about the Test:
Tested by: Mr. Xu Zhongwei
Test date: 2015-05-06
Instruments: Test site for luminaries Inventory number Description Manufacturer Type
RD-15-0060 EMI Receiver Rohde & Schwarz ESR7 RD-04-0125 Power Source KIKUSUI PCR1000CA RD-08-0352 Large loop Antenna SCHWARZBECK HXYZ9170
Environmental conditions: Rated value Measured value
Ambient temperature: 15 - 25 °C 23 - 25 °C
Information concerning the Test:
Test set-up: The device is located at the centre of a 2 m 3-Loop antenna. For built-in appliances the Technical Report CISPR 30(-1 for fluo; -2 for HID)
Operating mode: 1,2
Result: pass
Protocol: See next pages…
Report No.: 2015A0265
06-999-1110-01 Page 21 of 48
Standard Testing Laboratory Radiated Magnetic Field Strength(Loop Antenna)
Manufacture: Philips Lighting Electronics Test Date 06-May-2015
Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V
Antenna X Control number: LED-2015-0164-01
Operating mode: 230V/50Hz Operator: Xu Zhongwei
Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output
Scan setting:
Frequency Receiver setting
Start Stop Step IF BW detector Meas-time Atten Preamp OpRge
9KHz 150KHz 100Hz 200Hz PK 20ms Auto OFF 60dB
150KHz 30MHz 5KHz 9KHz PK 5ms Auto OFF 60dB
100 kHz 1 MHz 10 MHz9 kHz 30 MHz
-20.0
-10.0
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
-30.0
100.0
dBμA
Limits
LLA
Transducer
LLA
Traces
PK+
Report No.: 2015A0265
06-999-1110-01 Page 27 of 48
5.3 EN 55015 RF Emission in the frequency range 30 MHz - 300 MHz
Selected measurement method for RF disturbances in the frequency range from 30 to 300 MHz
x CDN-method according to Annex B of DIN EN55015
Antenna-method according to CISPR 22 clause 10
Remarks to the CDN Method:
If the lighting equipment complies with the requirements of Annex B of EN55015, it is deemed to comply with the limits of the sub clause 4.4.2 Table 3b - Radiated RF disturbances limits in the frequency range 30 – 300 MHz.
5.3.1 EN 55015 RF Emission in the frequency range 30 MHz - 300 MHz (CDN-Method)
General information about the Test:
Tested by: Mr. Yuan Yu
Test date: 2015-05-06
Instruments: Inventory number Description Manufacturer Type
RD-15-0060 EMI Receiver Rohde & Schwarz ESR7
RD-04-0125 Power Source KIKUSUI PCR1000CA
CDN / Clamps: Inventory number Description Manufacturer Type
RD-09-0113 CDN TESEQ CDNE310 RD-17-0005-4 CDN schaffner CDN A201
Environmental conditions: Rated value Measured value
Ambient temperature: 15 - 25 °C 23 - 25 °C
Information concerning the Test:
Test set-up: The EUT was tested as part of the reference luminaire in accordance with CISPR 30The test setup was make according to the decriptions of Annex B in EN 55015
Operating mode: 1,2,
Result: pass
Protocol: Next pages
Report No.: 2015A0265
06-999-1110-01 Page 28 of 48
Philips Lighting Standard Testing Laboratory RF Emission in Frequency range 30MHz-300MHz(CDN method)
Manufacture: Philips Lighting Electronics Test date 06-May-2015
Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V
Operating mode: 230V/50Hz Control number: LED-2015-0164-01
Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output
Operator: Yuan Yu
Scan setting:
Frequency Receiver setting
Start Stop Step IF BW detector Meas-time Atten Preamp OpRge
30MHHz 300MHz 30KHz 120KHz QP 2 Sec Auto OFF 60dB
100 MHz30 MHz 300 MHz
20.0
30.0
40.0
50.0
60.0
70.0
80.0
10.0
90.0
dBμV
Limits
Bersier
Transducer
M301 28
Traces
QP
Peak Search Results
Trace Frequency Level Limit Delta Limit Delta Ref Comment
(MHz) (dBμV) (dBμV) (dB) (dB)
* = limit exceeded