Test Report IESNA LM79 - 2008
Photometric testing and evaluation in accordance with LM79-2008
Laboratory : Ilmenau University of TechnologyGroup of Lighting EngineeringProf.-Schmidt-Str. 2698693 Ilmenau / Germany
Report prepared for: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany
Report number: LM79-20180403-10642 / 02
Testing performed by : ILEXA GbRWerner-von-Siemens-Straße 4a98693 Ilmenau / Germany
Tel.: (+49) 3677 / 466 33 0Fax: (+49) 3677 / 466 33 14Internet: www.ilexa.de
Sample tested: 6050/604 20W
Manufacturer: R. STAHL Schaltgeräte GmbH
Table of contents
1. Description of test sample................................................................................................31.1. General informationen......................................................................................................31.2. Manufacturer specifications..............................................................................................31.3. Pictures............................................................................................................................42. Scope of testing...............................................................................................................53. Equipment........................................................................................................................54. Additional information.......................................................................................................55. Test results.......................................................................................................................66. Results goniophotometer.................................................................................................76.1. Illuminance plots..............................................................................................................76.2. Candela plots...................................................................................................................87. Results spectroradiometer.............................................................................................107.1. Relative spectral distribution..........................................................................................107.2. Chromaticity diagram.....................................................................................................117.3. Color calculation.............................................................................................................12
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 2 of 12
General information
This report may not be reproduced except in full without permission of ILEXA GbR.
This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.
________________________________
Wladimir JordanowILEXA GbR president
1. Description of test sample
1.1. General information
Sample received: 29.03.2018
Manufacturer: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany
Model number: 6050/604-202-xxx-000850-000
Model type: Luminaire
Diameter / Height: 340mm / 195mm
1.2. Manufacturer specifications
Voltage [V]: 230.0 AC
Current [A]: -/-
Frequency [Hz]: 50.0
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 3 of 12
1.3. Pictures
Figure 1: Luminaire as measured
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 4 of 12
2. Scope of testing
-Photometric and electrical testing in accordance with IESNA LM 79 2008 IES (Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products).All measurements are made using the goniophotometer / spectroradiometer test method.
The spectral values are measured at a given direction with vertikal angle theta= 0°.
Date of test: 05.04.2018
Report and test prepared by: Kranhold / ILEXA GbR
3. Test equipment list
-Testing is performed in accordance with the procedures outlined in IESNA LM79 2008.The sample is evaluated for photometric and electrical characteristics using a goniophotometer, located in an temperature - controlled, draft free photometric laboratory.
Item Manufacturer Model Calibration due
Goniophotometer TechnoTeam RiGo801 yearly
Spectroradiometer Jeti specbos 1211 yearly
Power Supply Statron AG BE2/01H-IP-R20-B N/A
Digital Power Meter Yokogawa WT110 N/A
Table 3.1: Test instrumentation
4. Additional information
(none)
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 5 of 12
5. Test results
The results were obtained after stabilization of the sample in accordance with the requirements set forth in section 5.0 of IES LM79-2008.
Goniophotometer Spectroradiometer
Total luminous flux [lm] 2015 -
Luminous efficacy [lm/W] 122.9 -
Correlated color temperature (CCT) [K] - 4798
Color rendering index (CRI - Ra) - 81.9
Chromaticity (x / y) - 0.3522 / 0.3651
Table 5.1: Photometric results
Input power [W] 16.4
Input voltage [V] 229.9 AC
Input current [A] 0.0741
Input frequency [Hz] 50.0
Table 5.2: Electrical results
Orientation (burning position) during test horizontal
Prior operation time [minutes] 30
Stabilization time [minutes] >180
Total operating time [minutes] >180
Ambient temperature [°C] 24.7
Table 5.3: Additional Parameters
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 6 of 12
6. Results goniophotometer
6.1. Illuminance plots
Figure 2: Isolux diagram (mounting height 3m)
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 7 of 12
0 2-2 4 m-4 m
0 0
2 m 2 m
-2 -2
8,0
8,0
8,0
8,0
16 16
16
16
16
16
1632
32
32
32
32
32
64
64
64
ti l t angle :
swivel angle :
0,0
0,0
°
°
mounting height:
orientation :
3,0
0,0
m
°
light loss factor : 1,0
6.2. Candela plots
Figure 3: 3D - luminous intensity distribution
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 8 of 12
Figure 4: Polar candela distribution
Figure 5: Cartesian candela distribution
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 9 of 12
C0,0-C180,0 C90,0-C270,0
90°90°
75°
60°
45°
30° 15° 0° 15° 30°
45°
60°
75°
300
450
600
750
cd
0
150
300
450
600
750
900
0°45° 45°90° 90°135° 135°180° 180°
C0,0 C90,0
I (cd)
beam angle
7. Results spectroradiometer
7.1. Relative spectral distribution
Figure 6: Relative spectral distribution
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel. +493677 / 466 33-0 • Fax: +493677 / 466 33-14 • [email protected]
Date: 07.05.2018 Test Report IESNA LM79 - 2008 - Nr. LM79-20180403-10642 / 02Version: LM79-2018.04
Page 10 of 12
350 400 450 500 550 600 650 700 750 800 850 900 950 1000
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Wavelength [nm]
Rela
tive
spectr
al dis
trib
ution
7.3. Color calculation
color sample CRI color sample CRI
R1 79.7 R9 7.8
R2 86.6 R10 67.9
R3 91.6 R11 79.2
R4 81.0 R12 52.0
R5 79.4 R13 81.4
R6 80.8 R14 95.4
R7 88.3 R15 73.9
R8 67.6
Ra 81.9 CCT 4798 K
Table 7.2: Color calculation – CRI R1-R15, Ra and correlated color temperature