Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the traditional rational for the
certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
Who We Are
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Who We Are
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Our Customers:
Data Com Installers
(DCI) and Contractors
Who We Are
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Our Customers:
Data Com Installers
(DCI) and Contractors
Datacenter Architects,
Consultants and
Designers
Who We Are
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Our Customers:
Data Com Installers
(DCI) and Contractors
Datacenter Architects,
Consultants and
Designers
Communications
Service Technicians
Who We Are
Industrial
Automation
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Our Customers:
Data Com Installers
(DCI) and Contractors
Datacenter Architects,
Consultants and
Designers
Communications
Service TechniciansControls Engineers,
Electricians and System
Integrators
Who We Are
Industrial
Automation
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for
professionals who install and maintain critical network cabling infrastructure.
Our Customers:
Data Com Installers
(DCI) and Contractors
Datacenter Architects,
Consultants and
Designers
Communications
Service TechniciansControls Engineers,
Electricians and System
Integrators
Started in 1992 (part of FLUKE)
Worldwide Presence
Over 700 employees
Service customers in more than 120 countries
Industrial Technologies
Transportation Tech. Franchise Distribution
Professional Instrumentation
Field Solutions Product Realization Health Sensing Tech.
Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the
traditional rational for the certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
Driving Forces For The Certification Of Newly Installed Cabling
Building automation Datacenter Factory automation
M1I 1
C1E
1
M3I 3
C3E
3
( Commercial Building )
Driving Forces For The Certification Of Newly Installed Cabling
Building automation Datacenter Factory automation
M1I 1
C1E
1
M3I 3
C3E
3
( Commercial Building )
Obtain the manufacturers' warranty … Guarantee todays and future applications
Driving Forces For The Certification Of Newly Installed Cabling
Building automation Datacenter Factory automation
M1I 1
C1E
1
M3I 3
C3E
3
( Commercial Building )
Obtain the manufacturers' warranty … Guarantee todays and future applications
Prevent expensive downtime(Serial Process)
Driving Forces For The Certification Of Newly Installed Cabling
Building automation Datacenter Factory automation
M1I 1
C1E
1
M3I 3
C3E
3
( Commercial Building )
Obtain the manufacturers' warranty … Guarantee todays and future applications
Prevent expensive downtime(Serial Process)
Deployment is driven by cabling standards
Driving Forces For The Certification Of Newly Installed Cabling
Building automation Datacenter Factory automation
M1I 1
C1E
1
M3I 3
C3E
3
( Commercial Building )
Obtain the manufacturers' warranty … Guarantee todays and future applications
Prevent expensive downtime(Serial Process)
Deployment is driven by cabling standards
Verify the performance headroom between the installation and the application requirement(accommodate environmental changes and variation in the applications load)
Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the traditional
rational for the certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
Parameter: Insertion Loss
In dB, the signal loss down the cable
Probably the most important of all parameters
Depends on …
➢ Length
➢ Cable construction (Diameter, Shield, Twist Rate, …)
➢ Materials used
➢ Ambient temperature
Workmanship and installation is secondary
Parameter: Return Loss
In dB, the reflected signal on the same pair
Depends on the cable design and quality of the
manufacturing process
Workmanship and handling of the cable is critical
Zzzzzz
Parameter: TCL
Transverse Conversion Loss
In dB, the ratio of a common-mode voltage measured on
a wire pair at the near-end relative to a differential-mode
voltage applied to the near-end of the same pair
Depends on quality of the design and manufacturing of
cables and connectors
Workmanship and handling of the cable is less critical
(RL will suffer more)
Parameter: ELTCTL
Equal Level Transverse Conversion Transfer Loss
In dB, the normalized ratio of a common-mode voltage
measured on a wire pair at the far-end relative to a
differential-mode voltage applied to the near-end of the same
pair
Depends on quality of the design and manufacturing of
cables
Often considered an optional parameter for shielded system
Workmanship and handling of the cable is less critical
(RL will suffer first)
TCL / ELTCTL are Balance Parameters
In Laymen’s Terms: It stands for the conversion from
a desired “good” differential mode signal into an
undesired “bad” common mode signal and vice versa
in case of EMI
The topic is complex, but it is well explained
in the new “Balance e-Book”
click HERE or scan →
Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the traditional
rational for the certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
Adapting Cabling Tester For SPE
Are these SPE Adapters from the
recent automation show “Real”
products ?
Adapting Cabling Tester For SPE
Are these SPE Adapters from the
recent automation show “Real”
products ?
Adapting Cabling Tester For SPE
Solution based on the “Laboratory Adapter” for
the DSX-5000/8000
Ideal for assembly houses .... Lower running
cost because only the top “daughter board”
needs to be replaced
Fully functional for field trials
Source: Weidmüller
Will eventually be replaced by a regular
End2End/Channel/Patch Cord adapter
➢ Which housing M8 / M12 / Push Pull / All ?
Pictures Courtesy of Weidmüller
Interface GmbH & Co. KG
Adapting Cabling Tester For SPE
We discourage the use of hybrid courts to adapt to SPE
1. The RL, TCL, ELTCTL, would need to be 12+ dB better then
the test limit to not dominate the test result
Adapting Cabling Tester For SPE
We discourage the use of hybrid courts to adapt to SPE
1. The RL, TCL, ELTCTL, would need to be 12+ dB better then
the test limit to not dominate the test result
2. A calibration process works well for IL but not for low
frequency RL, TCL, ELTCTL
Adapting Cabling Tester For SPE
We discourage the use of hybrid courts to adapt to SPE
1. The RL, TCL, ELTCTL, would need to be 12+ dB better then
the test limit to not dominate the test result
2. A calibration process works well for IL but not for low
frequency RL, TCL, ELTCTL
3. Verification of the condition of the hybrid cord is very
complex
Needs For Testing A New Generation Of Connecting Hardware
1. Conceptional & Design In Phase
Laboratory Grade Tools
Needs For Testing A New Generation Of Connecting Hardware
1. Conceptional & Design In Phase
2. Experimental Phase(Early Implementers)
Laboratory Grade Tools
Needs For Testing A New Generation Of Connecting Hardware
1. Conceptional & Design In Phase
2. Experimental Phase(Early Implementers)
3. Implementation Tests
Laboratory Grade Tools
Needs For Testing A New Generation Of Connecting Hardware
1. Conceptional & Design In Phase
2. Experimental Phase(Early Implementers)
3. Implementation Tests
4. Large Scale Deployment(Tornado)
Field Test Tools
Laboratory Grade Tools
Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the traditional
rational for the certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
Trouble Shoot SPE Links
The RL margin is negative but
saved by the 3dB Rule
The RL plot suggest a cable
problem
The link is causing problem
The RL margin is negative
5m 2m
Trouble Shoot SPE Links
The RL margin is negative but
saved by the 3dB Rule
The RL plot suggest a cable
problem
The link is causing problem
The RL margin is negative
The HDTDR confirm a problem
in the second segment
5m 2m
Agenda
Who we are
The motivation for testing SPE cabling systems in comparison with the traditional
rational for the certification of new built cabling systems
The key performance parameters in a SPE system
Adapting cabling tester for SPE
Trouble shooting a SPE cabling system
The challenges for the installed base of cable testers in the testing of SPE
The challenges for the installed base of cable testers in the testing of SPE
Multiple housing M8 / M12 / PushPull / etc… will require “universal” adapters.
➢ Hybrid cords have not proven to be a good alternative
Many testers in the field today can not measure TCL and ELTCTL
Some of the long range version e.g.: 10Base-T1L specify performance down to 0.1 MHz
➢ The installed base of testers starts testing at 1.0 MHz
➢ Sounds trivial but represents a decade in frequency
➢ For IL the 0.1 …. 1.0 MHz extension may not offer significant findings.
For other parameters significant issues may be found < 1.0 MHz depending on topology
➢ Some testers may be modifiable through SW
Conclusion
Testing SPE links is feasible with some of the installed field testers
A mass roll out will require a ruggedized adapter with a universal
adaption for different housing
SPE testing is ready for you!
Thank You For Your Attention! … Questions?
Please fell free to reach out to us if you have questions
If you want to stay updated on news around Industrial Ethernet Testing