TESTING NVLAP LAB CODE 600150-0 Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1 st North Industry Road, Songshan Lake Science & Technology Park, Dongguan, Guangdong, China Tel: 86-769-22212079 Website: http://www.ntc-cert.com Report No: NTCLR20120116 Report Version: V1.4 Page 1 of 15 Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2017 Prepared For RAB Lighting Inc. Prepared By Dongguan New Testing Centre Co., Ltd. Prepare byReview by: Engineer: Alan Wang Technical Lead: Vincent Yuan Date: 2020-12-16 Issue Date: 2020-12-16 Revised Date: N/A

TESTING Report Version: V1.4 Photometric Test Report

  • Upload
    others

  • View
    2

  • Download
    4

Embed Size (px)

Citation preview

Page 1: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 1 of 15

Photometric Test Report

Relevant Standards

IES LM-79-2008

ANSI C82.77-2017

Prepared For

RAB Lighting Inc.

Prepared By

Dongguan New Testing Centre Co., Ltd.

Prepare by: Review by:

Engineer: Alan Wang Technical Lead: Vincent Yuan

Date: 2020-12-16 Issue Date: 2020-12-16

Revised Date: N/A

Page 2: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 2 of 15

1.0 Test Summary

DLC Technical Requirements V5.1

Outdoor – Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires

Requirement Category Test Method Requirements Test Value

Luminaire Output (lm)

(Goniophotometer – Section 4.2) (0°-180° zones) IES LM-79-2008 N/A 1838.7

Minimum Luminaire Efficacy (lm/W)

(Goniophotometer – Section 4.2) (0°-180° zones) IES LM-79-2008 N/A 148.64

Luminaire Output (lm)

(Goniophotometer – Section 4.2) (0°-90° zones) IES LM-79-2008 300 1480.1

Minimum Luminaire Efficacy (lm/W)

(Goniophotometer – Section 4.2) (0-90° zones) IES LM-79-2008

Standard

105

Premium

120 119.65

Power (Input Wattage) (W)

(Goniophotometer – Section 4.2) IES LM-79-2008 Worst Case 12.37

Total Harmonic Distortion (A%)

(THD & PF – Section 4.3) ANSI C82.77:2014

20.00% 120V 9.52

20.00% 277V 13.91

Power Factor

(THD & PF – Section 4.3) ANSI C82.77:2014

0.9 120V 0.9841

0.9 277V 0.9009

Allowable CCTs* (K)

(Integrating Sphere – Section 4.1) IES LM-79-2008

7 steps 3985±275 3988

4 steps 3985±154 3988

Minimum CRI

(Integrating Sphere – Section 4.1)

IES LM-79-2008

CIE13.3-1995 ≥70 71.9

Minimum R9

(Integrating Sphere – Section 4.1)

IES LM-79-2008

CIE13.3-1995 ≥-40 -18

Minimum Rf

(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 ≥70 76

Minimum Rg

(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 ≥89 96

IES Rcs,h1

(Integrating Sphere – Section 4.1) ANSI/IES TM-30-18 -18%≤IES Rcs,h1≤+23% -14%

Zonal Lumen Requirement (80°-90°)

(Goniophotometer – Section 4.2) IES LM-79-2008 ≤10% 9.86%

Input Voltage (V)

(Goniophotometer – Section 4.2) IES LM-79-2008

Worst Cast 120.0

(Goniophotometer – Section 4.2) Non-Worst Case 277.0

Input Current (A)

(Goniophotometer – Section 4.2) IES LM-79-2008

Worst Case 0.1043

(Goniophotometer – Section 4.2) Non-Worst Case 0.0049

Power (Input Wattage – W)

(Goniophotometer – Section 4.2) IES LM-79-2008

Worst Case 12.37

(Goniophotometer – Section 4.2) Non-Worst Case 12.31

Page 3: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 3 of 15

2.0 Test List

Test Item Test Test Date Model Number Sample No.

1 Integrating Sphere Test 2020-12-16 BRISKS17L-740 201207011-S1

2 Goniophotometer Test 2020-12-16 BRISKS17L-740 201207011-S1

3 THD and PF Test 2020-12-16 BRISKS17L-740 201207011-S1

Remark (If any)

1. The results contained in this report pertain only to the tested samples.

2. This report shall not be reproduced, no limited part or full, without approval of Dongguan New Testing

Centre Co., Ltd.

3. This report does not imply product certification, approval, or endorsement by NVLAP, or any agency of the

Federal Government.

3.0 Product Description

Luminaire Description: Wall Pack Light, Model No. BRISKS17L-740, 4000K

Electrical Specification: 120-277Vac, 50/60Hz, 14W

Photos of Luminaire Characteristics

Page 4: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 4 of 15

4.0 LM-79 Measurement and Test Results

4.1 Integrating Sphere Test

Model No. BRISKS17L-740 Sample ID 201207011-S1

Operate time

(Min.) 10

Stabilization time

(Min.) 60

Temperature

(°C) 25.4

Humidity

(%RH) 41.0

Test Method

The Samples were tested according to the IES LM-79-2008.

Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient

temperature condition inside the sphere was maintained at 25±1°C.

The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through

the detector port of the integrating sphere.

The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage) applied to the device

under test shall be regulated to within ±0.2 percent under load.

The sample was measured using 4π geometry and operated at rated voltage and was stabilized before measurement.

Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral

radiant flux measurements taken at 1 nm intervals over the range of 380 to 780nm.

Test Result

Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor

120.0 60 0.1043 12.37 0.9841

277.0 60 0.0049 12.31 0.9009

CCT (K) CRI R9 Duv Rf Rg IES Rcs,h1

3988 71.9 -18 -0.0003 76 96 -14%

Page 5: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 5 of 15

4.1 Integrating Sphere Test

Page 6: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 6 of 15

4.1 Integrating Sphere Test

x

y

u ' R a 73

v ' R 9 -18

Notes:CIE 13.3-1995

(CRI)

0.4381

0.4080

0.2496

0.5231

This is a recommended method fordisplaying ANSI/IES TM-30-18information.

0

10

20

30

40

50

60

70

80

90

100

CES

01C

ES03

CES

05C

ES07

CES

09C

ES11

CES

13C

ES15

CES

17C

ES19

CES

21C

ES23

CES

25C

ES27

CES

29C

ES31

CES

33C

ES35

CES

37C

ES39

CES

41C

ES43

CES

45C

ES47

CES

49C

ES51

CES

53C

ES55

CES

57C

ES59

CES

61C

ES63

CES

65C

ES67

CES

69C

ES71

CES

73C

ES75

CES

77C

ES79

CES

81C

ES83

CES

85C

ES87

CES

89C

ES91

CES

93C

ES95

CES

97C

ES99

Co

lor

Sam

ple

Fid

elit

y (R

f,C

ESi)

380 430 480 530 580 630 680 730 780

Rad

ian

t P

ow

er

(Eq

ua

l Lu

min

ous

Flu

x)

Wavelength (nm)

Reference Test

-0.0

2

0.1

0 0.1

9

0.1

5

0.0

9

-0.0

5

-0.1

4

-0.0

7

0.0

1

0.1

6 0.2

5

0.1

4

0.0

0

-0.1

3

-0.1

7

-0.2

0

-0.5

-0.4

-0.3

-0.2

-0.1

0.0

0.1

0.2

0.3

0.4

0.5

Loca

l Hue

Shi

ft (R

hs,hj)

74 7363

7585 85

7884 81

7065

74

8578 74 74

0102030405060708090

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Loca

l Col

or F

idel

ity

(Rf,

hj)

Hue-Angle Bin (j)

-14

%

-12

% -4%

5% 8

% 8%

-1%

-7%

-12

%

-12

% -6%

7% 9% 11%

1%

-7%

-40%

-30%

-20%

-10%

0%

10%

20%

30%

40%

Loca

l Ch

rom

a Sh

ift

(Rcs

,hj)

-20%

20%

1

2

3

45

16

6

7

8

9

10 15

11

12 13

14 Duv

76

CCT

96

0.0014

RgRf

3012 K

Page 7: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 7 of 15

4.0 LM-79 Measurement and Test Results

4.2 Goniophotometer Test

Model No. BRISKS17L-740 Sample ID 201207011-S1

Operate time

(Min.) 30

Stabilization time

(Min.) 60

Temperature

(°C) 25.3

Humidity

(%RH) 47.3

Test Method

The Samples were tested according to the IES LM-79-2008.

Photometric parameters were measured using a type C goniophotometer and software.

The ambient temperature shall be maintained at 25±1°C, measured at a point not more than 1 m from the sample and

at the same height as the sample.

The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage) applied to the device

under test shall be regulated to within ±0.2 percent under load.

The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire

efficacy, zonal lumen were calculated from the software taken at 1.0° vertical intervals and 15° horizontal intervals.

Test Conditions

Condition Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor

WORST CASE 120.0 60 0.1043 12.37 0.9841

NON-WORST CASE 277.0 60 0.0049 12.31 0.9009

Test Result

Result

Type Flux (lm)

Field Angle (10%) Beam Angle (50%) Luminous

Efficacy

(lm/W)

Zonal Lumen

Requirement

(80°-90°)

BUG

Rating C0-180 C90-270 C0-180 C90-270

0°-180°

zones 1838.7 120.5 120.5 34.6 97.6 148.64 7.90% B1-U3-G2

0°-90°

zones 1480.1 120.5 120.5 34.6 97.6 119.65 9.86% B1-U3-G2

Page 8: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 8 of 15

4.2 Goniophotometer Test

Lighting Distribution Curve

Isolux Plot

Page 9: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 9 of 15

4.2 Goniophotometer Test

Zonal Lumen Summary

Zonal (lm) Total (lm) Percent0-10 39.77 0-10 39.77 2.16%10-20 112.39 0-20 152.16 8.28%20-30 165.18 0-30 317.34 17.26%30-40 195.84 0-40 513.18 27.91%40-50 211.74 0-50 724.92 39.43%50-60 217.01 0-60 941.93 51.23%60-70 208.60 0-70 1150.53 62.57%70-80 183.55 0-80 1334.08 72.56%80-90 146.01 0-90 1480.09 80.50%90-100 112.44 0-100 1592.53 86.61%100-110 85.25 0-110 1677.78 91.25%110-120 62.06 0-120 1739.84 94.63%120-130 43.24 0-130 1783.08 96.98%130-140 28.21 0-140 1811.29 98.51%140-150 16.61 0-150 1827.90 99.42%150-160 7.93 0-160 1835.83 99.85%160-170 2.56 0-170 1838.39 99.99%170-180 0.26 0-180 1838.65 100.00%

Page 10: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 10 of 15

4.2 Goniophotometer Test

LCS/UBG

Page 11: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 11 of 15

4.2 Goniophotometer Test

Coefficients of Utilization

Isolines

Page 12: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 12 of 15

4.2 Goniophotometer Test

Luminous Distribution Intensity Data

Page 13: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 13 of 15

Page 14: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 14 of 15

4.0 LM-79 Measurement and Test Results

4.3 THD and PF Test

Model No. BRISKS17L-740 Sample ID 201207011-S1

Temperature

(°C) 25.4

Humidity

(%RH) 41.0

Test Method

The samples were tested according to the ANSI C82.77:2014

The total harmonic distortion shall be measured to the 40th order.

The ambient temperature shall be maintained at 25±1°C. The sample measurements were made using a digital power

meter and power supply. The sample was operated at rated voltage and was stabilized before measurement. The total

harmonic distortion was calculated.

Test Results

Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor iTHD(%)

120.0 60 0.1043 12.37 0.9841 9.52

277.0 60 0.0049 12.31 0.9009 13.91

Page 15: TESTING Report Version: V1.4 Photometric Test Report

TESTING NVLAP LAB CODE 600150-0

Laboratory: Dongguan New Testing Centre Co., Ltd Address: 3F, No. 1 the 1st North Industry Road, Songshan Lake Science & Technology Park, Dongguan,

Guangdong, China

Tel: 86-769-22212079

Website: http://www.ntc-cert.com

Report No: NTCLR20120116

Report Version: V1.4

Page 15 of 15

5.0 Equipment List:

Equipment ID Equipment Name Last Cal. Due Cal.

NTC-F01-001 Goniophotometer System 2020-11-12 2021-11-11

NTC-F01-006 2.0 meter Integrating Sphere 2020-11-12 2021-11-11

NTC-F01-012 Standard Lamp 2020-11-12 2021-11-11

NTC-F01-013 Standard Lamp 2020-11-12 2021-11-11

NTC-F01-031 Digital Power Meter 2020-08-22 2021-08-21

NTC-F01-019 Temperature & Humidity Meter 2020-11-13 2021-11-12

**********End of Report**********