Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
© b
y D
oka
Gm
bH, A
-330
0 Am
stet
ten
999808602 11/2017en-GB
-
The Formwork Experts.
Concremote Web portalUser ManualPlease retain for future reference© by Doka GmbH, A-3300 Amstetten
2 999808602 - 11/2017
User Manual Concremote Web portal
Contents
3 Introduction3 General remarks
4 The Doka Concremote service4 System description
6 Overview and introduction
12 Application and usage
User Manual Concremote Web portal Introduction
3999808602 - 11/2017
IntroductionGeneral remarks
Remarks on this booklet
▪ This manual describes the Concremote Web portal, its function and intended use.
▪ This booklet is aimed at all persons who will be work-ing with the Doka product or system that it describes. It contains information on the standard design for setting up this system, and on correct, compliant uti-lisation of the system.
▪ All persons working with the product described herein must be familiar with the contents of this booklet and with all the safety instructions it contains.
▪ Customer is required to provide instruction and famil-iarisation for persons unable to read and understand this document, or who experience difficulty in doing so.
▪ The customer is to ensure that the information mate-rials provided by Doka (e.g. User Information book-lets, Instructions for Assembly and Use, Operating Instruction manuals, plans etc.) are up to date and available to all users, and that they have been made aware of them and have easy access to them at the usage location.
Manufacturer
▪ B | A | S Remote Sensing B.V. ▪ We reserve the right to make alterations in the inter-
ests of technical progress.
Support
Symbols used
The following symbols are used in this booklet:
Landline: International, Netherlands, Belgium: +31 77 850 7220 Germany, Austria: +49 281 1649 0890
E-mail: [email protected]
NOTICEFailure to observe this may lead to malfunc-tion or damage.
CAUTION / WARNING / DANGERFailure to observe this may lead to material damage, and to injury to health which may range up to the severe or even life-threaten-ing.
InstructionThis symbol indicates that actions need to be taken by the user.
Sight-checkIndicates that you need to do a sight-check to make sure that necessary actions have been carried out.
TipPoints out useful practical tips.
ReferenceRefers to other documents and materials.
4 999808602 - 11/2017
The Doka Concremote service User Manual Concremote Web portal
The Doka Concremote serviceSystem description
Concrete monitoring: how it works, how it is used
Measuring concrete strength in real time.Concremote is a service for performing non-destructive real-time measurement of concrete strengths in struc-ture members (floor-slabs, walls, beams, etc.) on the site.This service comprises two parts: ▪ measuring-sensors ▪ data management and processingThe sensors placed on the structure member continu-ously measure the heat development of the concrete, which is mainly influenced by the hydration heat of the cement and by ambient temperatures. The more intense the heat development, the faster the strength development of the concrete.The measured data (temperature measurements) from the structure member are transmitted to the com-puting centre via the mobile communications network as data packets. At the computing centre, they are automatically evaluated by the maturity monitoring method, using calibration measurement.A separate calibration measurement is needed for each different grade of concrete to be measured at the site. This calibration measurement must be performed either by the clients themselves, by the concrete sup-plier or by an appointed test laboratory – ideally, using Concremote calibration boxes. For this purpose, six cubes are stored under defined partially adiabatic con-ditions. The cubes are tested at different times, depending on the target value (for stripping, curing, etc.). Each of these tests yields a compressive strength value, and the temperature value associated with it. From this calibration measurement, the relationship can be computed between the strength and the matu-rity of the grade of concrete concerned.The Concremote Web portal continuously provides these data and strengths to its users. This enables the user to follow the concrete strength development 'live'.As soon as the target value is reached, the next steps (stripping, pre-stressing, etc.) can be taken.
Precise measurement facilitates accurate control
Efficient construction processesThe strength values computed by Concremote accord-ing to the mainstream maturity methods (de Vree, Arrhenius, Nurse-Saul), permit targeted control of form-ing and concreting operations in real time.Concremote provides very accurate results on the basis of reference values, which in turn are based on the cube strengths obtained from the calibration meas-urement.It records profiles of both the concrete temperature and the ambient temperature around the sensors.
Multi-functional
2 types of sensorThe Concremote slab sensor and the Concremote cable sensor can be used in a targeted manner in all areas of cast-in-place building construction.
▪ CIP concrete slabs ▪ Wall and column formwork ▪ Crane-climbed and automatic climbing projects ▪ Bridge and tunnel building sites ▪ Mass concrete structures
Easy to use
Wireless data transmission and easy access from anywhereThe user-friendly Concremote Web portal can be used effortlessly and can be accessed from any internet-enabled device at any time.
User Manual Concremote Web portal The Doka Concremote service
5999808602 - 11/2017
Certainty for the construction project
Helps you take decisions and records your data ▪ Compliant decision-making based on the measured
data. ▪ Strength development can be estimated early on
from graphs. ▪ Printing and storage of data for long-term verifica-
tion.
Exact results enabled by calibration
The Concremote calibration box is used to cali-brate the different grades of concrete used. These calibration measurements provide reference data for computing the compressive strength develop-ment in relation to the maturity.Before the sensors are used, Concremote generates a calibration curve for each grade of concrete, by means of the Concremote calibration boxes.
Online data access
Via the user-optimised, web-based programme, users can access the data at any time. Furthermore, they can grant read and write permissions.Users can store data and unlock them for use by authorised persons.Accurate documentation ensures both certainty for the building process and transparency.
The temperature, maturity and strength data will help you take many decisions more accurately: ▪ Stripping time ▪ Crack width limitation (stresses) ▪ Loads ▪ Curing measures ▪ Pre-stressing ▪ Cycle times ▪ Temporary reshoring ▪ Construction conditions ▪ Concrete orders ▪ Team coordinationetc.
Process scheme
Follow the directions in the ‘Concremote cali-bration box’ User Information booklet.
Follow the directions in the ‘Concremote’ User Information booklet.
9 86 82580 -
6 999808602 - 11/2017
Overview and introduction User Manual Concremote Web portal
Overview and introduction
Login
You will receive your Concremote Web portal login details by e-mail as soon as you have placed your order for Concremote.To log in enter the following web address into your browser http://concremote.doka.com.
Home page
After logging in you will be redirected to the home page. The home page gives you an overview of the existing projects.
Selection options on the left-hand side: ▪ 'Menu': Opens the menu options. ▪ 'Concremote': Takes you to your measurements,
the available devices (sensors) and the available concrete mixtures and calibration curves.
▪ 'Your user name' (in the window, top right): Here you will find
- Contact details- Change password- Log-off
9 86 82680 -
NOTICE ▪ You have to define a personal password
when you visit the Web portal for the first time.
▪ If, at some time, you find you have forgotten or mislaid your password, click on 'Forgot-ten your password?' to reset the pass-word.
▪ After starting the application, you can change the default password. Just click on your user name at the top right of the start screen and select 'Change password'.
▪ You are not allowed to pass your login details on to unauthorised persons.
A Starting the Web portal (link to the graph page)B Overview of structures, measurements and sensor statusC Personal data and contact details
9 86 82780 -
A B
C User name
NOTICEYou can exit the Web portal securely at any time by clicking on your user name and then on the 'Logout' button.
User Manual Concremote Web portal Overview and introduction
7999808602 - 11/2017
Graph page
You can open the graph page by going to 'Concre-mote' and then selecting 'Measurements'. Alterna-tively, you can select a measurement directly on the home page by selecting 'Measurement selection'.
9 86 86380 -
A Measurement selection menu: You can select existing measure-ments here. Drop-down menu: The choices are: - New - Edit - Delete - User (project only) - Notification (measurement only) - Copy (measurement only) It is also possible to change the choice of 'Project', 'Structure', 'Location' or 'Part' of the measurement.
B Visualisation of compressive strength, temperature, maturity and temperature difference (delta T)
C Details of the measurement (measuring period, details of the concrete, calculation method, sensor status)
D Buttons for creating a report, viewing detailed measured data and downloading.
9 86 82880 -
A
B
C
D
User name
8 999808602 - 11/2017
Overview and introduction User Manual Concremote Web portal
Buttons (D) at the top right-hand corner of the graph page:'Create report' button ▪ Click on this button to open a window in which you can
create a report for the selected measurement:
'Detailed measured data' button ▪ Click on this button to view the detailed measured
data.
'Graph page' button ▪ Click on this button to view the graph page.
'Download' button for Excel file ▪ Click on this button to start automatic download of the
detailed measured data as an Excel file.
9 86 83080 -
User Manual Concremote Web portal Overview and introduction
9999808602 - 11/2017
Selecting a measurement
➤Select the desired project, structure, location and part (from top to bottom) in the drop-down menu on the left-hand side .
➤Then select a measurement from the drop-down list at the bottom of the menu.
Under 'Measurement details' in the middle part of the drop-down menu you can see the parameters filed for the measurement.
What the graphs illustrate
There are four views, each showing detailed informa-tion; you can zoom these views: ▪ ‘Compressive strength’: in MPa (N/mm²) or psi. ▪ ‘Temperature’: in degrees Celsius or Fahrenheit. ▪ ‘Maturity’. In degrees Celsius-hours (°Ch) ▪ ‘Delta T’. The temperature difference between
defined measuring points, in degrees Celsius.
What the graphs show
Compressive strength
In this graph you can monitor the compressive strength development.Move the mouse pointer along the curve to view the measured values for each time stamp. The legend below the graph explains the use of the various colours.
9 86 83180 -
9
8683
280
-
9 86 82880 -
WARNING➤Decisions based on non-calibrated data
(outside the green area) can lead to injury.
A Compressive strength developmentB Target value and target-value lineC Calibrated rangeD Non-calibrated range (white)
9 86 83380 -
A
C
D
B
10 999808602 - 11/2017
Overview and introduction User Manual Concremote Web portal
Temperature
This graph illustrates the temperature profile of the measurement as a function of time.The concrete temperature and the ambient tempera-ture recorded by the sensor are both displayed in one graph in different colours. Move the mouse pointer along the curve to view the measured values for each time stamp.The legend below the graph explains the use of the var-ious colours.
Maturity
The maturity curve is generated on the basis of the measured temperature, the time, as well as the con-crete data on which the measurement is based.Move the mouse pointer along the curve to view the measured values for each time stamp.
Delta T (temperature difference)
The delta-T curve shows the difference in temperature between the defined measuring points. The difference in temperature, for example between concrete core and the surface of the concrete, should be as small as pos-sible in order to avoid cracking; this applies in particular to mass-concrete structures.Move the mouse pointer along the curve to view the measured values for each time stamp. The legend below the graph explains the use of the various colours.
Download graphic
You can download any graphic as a PDF or PNG file by clicking this button.
A Concrete temperature measured by the sensorB Ambient temperature measured by the sensor
A Development of weighted maturity
9 86 83480 -
AB
9 86 83580 -
A
A Temperature difference between defined measuring points
9 86 83680 -
A
User Manual Concremote Web portal Overview and introduction
11999808602 - 11/2017
Project management
If you have authorisation to create new projects and measurements, you can do so by going to 'Measure-ment selection' and clicking on the grey drop-down button beside 'Project'.
Selection options: ▪ ‘New’: For creating a new project in the drop-down
menu. ▪ 'Edit': For editing an existing project. ▪ 'Remove': For deleting the selected project. ▪ 'User': For adding or deleting users enabled for the
selected project.If you select 'New' a window opens in which you can 'Create a new project'. If you select 'Edit' a window opens in which you can 'Edit an existing project'.
A Drop-down button
9 86 83880 -
A
9 86 83980 -
9 86 84080 -
12 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
Application and usage
General
This section describes the most important ways in which the Concremote Web portal can be used. If you have any further questions or problems, please contact Concremote support or your Doka contact person.General notes regarding the measured data: ▪ All of the data measured and transmitted by the sen-
sors are stored in the computing centre for years. ▪ These data remain stored in the computing centre
even if a measurement is deleted from the Concre-mote Web portal.
▪ So a measurement deleted in the Concremote Web portal can easily be restored and the measurement result displayed again on the basis of the data stored in the computing centre.
Active symbols
Inactive symbols
Function test
It is recommended to perform a function test each time before using Concremote in a structure.➤Add a measurement with all existing sensors.➤ Insert the battery to activate a slab sensor and con-
nect the cable to activate a cable sensor.➤Check the sensors in the overview given on the
home page or on the graph page.
Drop-down button
'Create report' button
'Detailed measured data' button
'Graph page' button
'Download' button for Excel file
Pop-up menu
Sensor status: OK (click on the button for details)
Sensor status: Error (click on the button for details)
Sensor status: Done (click on the button for details)
A function test is particularly important for pro-jects where connectivity may be limited.
NOTICEIf a failure occurs, immediately inform Concre-mote support or your Doka contact person.
User Manual Concremote Web portal Application and usage
13999808602 - 11/2017
Create structure, location and part
➤Click on 'Concremote' (A) on the left-hand side and then select the project from 'Measurement selec-tion'.
➤Click on the drop-down button beside the structures list and select 'New' (B) . You can also edit or delete an existing structure.
➤The 'Add structure' window opens and you can enter a name for the new structure.
➤After clicking on 'Save' you can follow the same pro-cedure again to add or edit a location and a structure member, as applicable.
A 'Concremote' buttonB 'New' menu item
Use meaningful descriptors, e.g. 'Structure member A', 'House 1', etc.
9 86 84180 -
B
A
9 86 84380 -
14 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
How to add a measurement
Start by selecting from the 'Measurement selection' section the project for which you want to create a new measurement.➤Click on the drop-down button and select 'New'. You
also have the option of editing existing measure-ments by clicking on 'Edit'.
Step 1
➤Add a description and a starting date to the measure-ment.
➤ If applicable, activate the 'Close measurement automatically when target value is reached' checkbox. Otherwise, clear the tick from this check-box.
➤Confirm that you have read and accepted the gen-eral terms and conditions of use by activating the ‘I agree to the Terms & Conditions of Concremote' checkbox.
➤Select 'Continue' to move on to the next step.
9 86 84480 -
9 86 84580 -
User name
User Manual Concremote Web portal Application and usage
15999808602 - 11/2017
Step 2
➤Select the correct concrete mixture and calibration curve for this measurement.
➤Click on 'Next' to proceed to the next step.
Step 3
➤Click on the drop-down buttons and select the devices and the configuration of the sensors. If you need to add devices, click on the plus sign ('+').
➤Click on 'Next' to proceed to the next step.
NOTICE➤You have to confirm your choice of concrete
mixture before you can proceed to step 3 by clicking on 'Next'. Make sure that the con-crete mixture you selected corresponds to that actually used for the structure.
➤You can leave both these fields blank if you merely want to have the temperature logged.
9 86 84680 -
User name
9 86 84780 -
User name
16 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
Step 4
➤Configure the device by selecting a colour and nam-ing the measuring points in the first column.
➤At 'Temperature/compressive-strength develop-ment', select the parameters you want to have graphed in measurement. The precondition for 'Compressive-strength development' is prior calibra-tion of the concrete mixture(s), with the correspond-ing data filed and accessible to the program.
➤Click on 'Next' to proceed to the next step.
➤By selecting 'Add' you include an additional step in which you configure notification.
➤Click on 'Yes' to acknowledge the prompt and create a notification (see the section headed 'Configure notification', 'Step 1')
➤Click on 'No' in response to the prompt if you prefer to configure confirmation at a later point in time.
9 86 84880 -
User name
9 86 84980 -
User Manual Concremote Web portal Application and usage
17999808602 - 11/2017
Measuring points of the devices
▪ 0: Ambient temperature (measurement of the air temperature using the sensor)
▪ 1-3: Measurement of the concrete temperature using the sensor, either by means of a sensing element inside the sensor or with a cable (in cables with 3 measuring points, position 1 is the first measuring point after the sensor)
Concremote slab sensor
Concremote cable sensor
Option with sensing element wall
Has to be connected to the cable sensor.
Option for (lost) cable with 1 or 3 sensors
Has to be connected to the cable sensor.
A Measuring point 0: Measurement of the ambient temperature in the sensor housing
B Measuring point 1: Concrete temperature
A Measuring point 0: Measurement of the ambient temperature in the sensor housing
B Connection for wall sensor or (lost) cable
9 86 84980 -9 86 85080 -
A
B
9 86 85180 -
A
B
A Measuring point 1: Sensor for concrete temperature
A Measuring point 1(-3): Sensor(s) for concrete temperature
9
8685
280
-
A
9 86 85380 -
A
A
A
18 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
Configure notification (text message or email)
➤You can configure text-message (SMS) or email notification either when you are creating a sensor or afterwards, by clicking on the drop-down button beside a selected measurement and selecting 'Noti-fications'.
➤Clicking on the 'Notifications' button opens the noti-fication menu, where you can view existing notifica-tions and delete or add notifications.
➤Click on the 'Add' button to create a new notification.
9 86 85480 -
9
8685
580
-
User name
User Manual Concremote Web portal Application and usage
19999808602 - 11/2017
Step 1
➤Enter a descriptive text for the notification (e.g. 'Tar-get value achieved' and select a notification type from the drop-down menu. You can choose between 'At a fixed time' and 'When reaching a defined value'
➤Then add the recipient(s) of the notification by click-ing on the drop-down button in the bottom part of the screen. Select notification by text message (SMS) or email by ticking the checkboxes as appropriate and selecting the correct values.
➤You can add recipients by clicking on the plus sign ('+') on the right.
➤Click on 'Continue' to proceed to the next step.NOTICEIf a person to be notified is missing from the list, inform Concremote support or your desig-nated Doka contact person accordingly.
Optional: Control external devices (e.g. heating or cooling systems):You can also select the port via which notifica-tion will be received. You can also select the command (ON or OFF) that will trigger notifica-tion.
9 86 85780 -
9
8685
680
-
User name
20 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
Step 2a (At a fixed time)
This step depends on your choice of notification type in Step 1.➤ If you selected 'At a fixed time', you can now enter
the date and the time when you want notification sent.
➤Click on 'Save' to save the notification settings and return to the notification menu.
Step 2b (When reaching a defined value)
➤ If you selected 'When reaching a defined value', the next step is to decide whether you want to acti-vate the 'Receive separate notification for each measuring point' checkbox.If you do not activate this checkbox notification is issued as soon as all the selected measuring points have reached the target value.
➤The 'Compressive strength' part of the screen is where you select the sensor values, the preferred criteria and the target value. You can click on 'Add delta, temperature/maturity' if you want to add more criteria.
➤Click on 'Save' to save the notification settings and return to the notification menu.
9
8685
880
-
User name
9
8685
980
-
User name
User Manual Concremote Web portal Application and usage
21999808602 - 11/2017
How to repeat and copy a measurement
➤To copy a measurement, just select the measure-ment you want to copy and click on its drop-down button. Click on 'Copy'.
➤A pop-up window opens and you can enter a name, the starting date and also the starting time for the measurement. Here too, you have to confirm that you accept the 'General terms and conditions' and then click on 'Copy' again.
Reading the data
After entering all the data, you can monitor the meas-urement on the graph page. The recorded data are dis-played with a one-hour delay.
Note: ▪ If only the temperature is shown, without the com-
pressive strength, no calibration curve is on file for this measurement or you did not select a calibration curve.
▪ Note that compressive strength is not displayed until a certain maturity level has been reached. If ambient temperatures are low, for example, it might take a while before the compressive-strength cure appears.
▪ You can hide and show individual curves in the graph. You do this by clicking on the corresponding elements in the legend underneath the graph. A greyed text indicates a hidden curve.
Optional: Manual conclusion of a measurement
You can conclude a measurement in progress at any time by clicking on 'Stop measurement'.
9 86 86080 -
9 86 86180 -
9 86 86480 -
9 86 86580 -
22 999808602 - 11/2017
Application and usage User Manual Concremote Web portal
User Manual Concremote Web portal Application and usage
23999808602 - 11/2017
999808602 - 11/2017Doka GmbH | Josef Umdasch Platz 1 | 3300 Amstetten | Austria | T +43 7472 605-0 | F +43 7472 66430 | [email protected] | www.doka.com
Near to you, worldwide
Doka is one of the world leaders in developing, manu-facturing and distributing formwork technology for use in all fields of the construction sector.With more than 160 sales and logistics facilities in over 70 countries, the Doka Group has a highly efficient dis-tribution network which ensures that equipment and
technical support are provided swiftly and profession-ally.An enterprise forming part of the Umdasch Group, the Doka Group employs a worldwide workforce of more than 6000.
www.doka.com/concremote