www.paclp.com The Globally Accepted Industry Standard for Gasoline Testing AC REFORMULYZER ® M3 WORLDWIDE ACCEPTED INDUSTRY STANDARD FOR GASOLINE & GASOLINE BLENDS TESTING • Group Type Analysis per Carbon Number for O-PIONA Samples • Complete Solution with Calculation Reporting, Diagnostic Tool, Certified QC Samples and Trend Recording • Fully Compliant with ASTM D6839, D5443, EN 14517 and ISO 22854

The Globally Accepted Industry Standard for Gasoline ...supertec.com.ar/archivos/23_archivo.pdfThe Globally Accepted Industry Standard for Gasoline Testing ... • UOP 870 • ISO

Embed Size (px)

Citation preview

www.paclp.com

The Globally Accepted Industry Standard for Gasoline Testing

Ac RefoRmulyzeR® m3

WORLDWIDE ACCEPTED INDUSTRY STANDARD FOR gASOLINE & gASOLINE BLENDS TESTINg

• Group Type Analysis per Carbon Number for O-PIONA Samples• Complete Solution with Calculation Reporting, Diagnostic Tool,

Certified QC Samples and Trend Recording • Fully Compliant with ASTM D6839, D5443, EN 14517 and ISO 22854

ThE WORLDWIDE ACCEPTED INDUSTRY STANDARD IN gASOLINE & gASOLINE BLENDS TESTINgAC Analytical Controls pioneered, developed and optimized the AC Reformulyzer® Mark 3 (M3) application, which is used globally by nearly all refineries. The Reformulyzer® M3 analysis is based on a multi-dimensional column switching technique. After sample introduction, a set of columns and traps separates the sample into different hydrocarbon groups. The multi-dimensional technique determines carbon number distribution for (Iso-)Paraffins, Olefins, Naphthenes, Aromatics and Oxygenates. The Reformulyzer® M3 complies with accepted international standard test methods, including: • ASTM D5443, (D6293), D6839• IP 382, (526), 566• UOP 870• ISO 22854

AC Reformulyzer® M3 analysis of gasoline in 75 minutes

AC

Ref

orm

ulyz

er® M

3

WIDE RANgE OF REPORT OPTIONS• Hydrocarbon type concentrations by carbon number in

weight% and liquid volume%

• Oxygenated component concentrations in weight% and liquid volume% as specified by EN 228

• Benzene, Total Aromatics, Total Olefins and Total Saturates in liquid volume%; Oxygen in weight%, Oxygenates in liquid volume%

• Density in g/ml, kg/m3 and lb/gal• Average molecular weight• RON/MON calculation for the PIONA mode• C:H:O ratio and Calorific Value• Excellent LIMS connectivity: upload the results directly to

your LIMS or manually after approval

AC Reformulyzer® M3 report options

Report of a Winterspec analysis

reformulyzer 048 Winterspec AC

Data FileName Operator Acquired On Processed On Sample Name

Sample Type Instrument Method

C:\Chem32\1\DATA\D1002\048 Winterspec4.dAdmin2/17/2010 1:30:25 PM2/17/2010 1:30:29 PM048 Winterspec

Winter02Winterspec ETBE

104Vial Inj Volume 0,1 μ

:::::::

:

:l:

SampleGroup:

Winterspec EtOH/ETBE

00.02.048C048 Gasoline N lot 004

Reference Number:Reference Name

:

Analysis ConditionsA 3.4 EthAlcSep 110B 5.3 OlefinSep1 100E 2.5 OlefinSep2 150

Normalized weight percent resultsC-nr Naph. Paraf. Cycl Ol. Olef. Arom . Oxyg. Total

12 0.95 0.95 34 0.99 0.48 1.47 5 0.24 10.44 0.14 3.53 14.35 6 1.77 9.47 0.45 2.76 0.96 9.96 25.37 7 1.42 6.93 0.38 1.72 9.96 20.41 8 0.98 8.75 0.13 0.87 14.67 25.40 9 0.39 1.01 0.29 8.42 10.12 10 0.04 0.90 0.94

11+ 0.69 0.29 0.98 PolyTotal 4.80 38.28 1.10 9.70 35.21 10.90 100.00

Normalized volume percent resultsC-nr Naph. Paraf. Cycl Ol. Olef. Arom . Oxyg. Total

12 0.89 0.89 34 1.27 0.59 1.86 5 0.24 12.61 0.13 4.04 17.02 6 1.72 10.66 0.42 3.01 0.81 9.96 26.57 7 1.38 7.47 0.36 1.81 8.50 19.52 8 0.93 9.13 0.12 0.89 12.50 23.58 9 0.37 1.03 0.30 7.16 8.85 10 0.04 0.76 0.80

11+ 0.67 0.25 0.92 PolyTotal 4.63 42.83 1.04 10.67 29.98 10.84 100.00

Oxygenate Wt% LV% O2%

Oxygenates results

ETBE 9.96 9.96 1.56Ethanol 0.95 0.89 0.33Total 10.90 10.84 1.89

EN 14517 / ASTM D 6839

Benzene 0.81 LV%Total Aromatics 29.98 LV%Total Olefins 11.71 LV%Total Oxygenates 10.84 LV%Total Saturates 47.47 LV%Total Oxygen 1.89 Wt%

Reports Fuel Specifications EN228 includes the EN ISO 22854 (Multidimensional GC, Reformulyzer) as Referee Method for Hydrocarbon content (Olefins & Aromatics), Benzene, Oxygenates and Oxygen content. It therefore replaces FIA (EN15553) for Hydrocarbon content, EN12177 for Benzene and EN1601 for Oxygenates.

QUALITY CONTROL SAMPLESBesides the gravimetric PIONA standards, AC offers a set of quality control samples that covers most light petroleum streams:

• Reformer feed• Reformate• FCC naphtha• Gasoline containing MTBE

• Oxygenates free gasoline • Gasoline containing Ethanol • Gasoline containing ETBE &

Ethanol

www.paclp.comANALYSIS SIMULATION PROGRAMTRAINING TOOL FOR SELF-ExPLANATORY OPERATION

AC developed the Reformulyzer® M3 Analysis Simulation Program to train users in the multi-dimensional technique, by showing the analysis sequence step-by-step. The program demonstrates sample separation through various columns and traps integrated into the software. Simultaneously the elution pattern can be observed in the chromatogram.

INTEgRATED DIAgNOSTIC TOOL AUTOMATES vALIDATIONAC has developed an integrated diagnostic tool to validate the Reformulyzer® M3’s performance.

After analysis of the QC samples, the diagnostic tool reports validation and statistical data for:• a specific analysis• a series of analyses over a longer

period

The diagnostic tool will automatically mark results outside specification limits. You will find these marked results in the on-screen report. The diagnostic tool also advices on possible causes for components exceeding the limits and reviews data for trend recording.

AC Reformulyzer® M3 Diagnostic Tool

AC Reformulyzer® M3 on-screen report

AC REFORMULYzER® M3 USER gROUPReformulyzer® users can join the AC User Group. AC organizes interactive meetings periodically that allow users to share and exchange technical knowledge.An important part of the user group is the Performance Monitoring Program (PMP), a regular round robin anonymous testing program that helps labs verify their analyzer’s precision.Results are processed anonymously; AC reports the statistical values and offers suggestions for improving precision.The 2010 PMP test consisted of 4 samples: three gasolines, one high olefinic FCC naphtha. One gasoline contained a relative high ethanol concentration, exceeding the current Fuel specifications limits to prepare the analyzer for possible future market developments.

solidpartnersproven solutions

U.S.A.PAC, LP | 8824 Fallbrook Drive | Houston, Texas 77064T: +1 800.444.TEST | O: +1 281.940.1803 | F: +1 [email protected] | [email protected]

FRANCEBP 70285 | Verson | 14653 CARPIQUET CedexT: +33 (0) 231 264 300 | F: +33 (0) 321 266 [email protected] | [email protected]

GERMANYBadstrasse 3-5 | P.O.Box 1241 | D-97912 Lauda-Königshofen, T: +49 9343 6400 | F: +49 9343 640 [email protected] | [email protected]

SINGAPORE61 Science Park Road | #03-09/10 The GalenSingapore Science Park III | Singapore 117525T: +65 6412 0890 | F: +65 6412 [email protected] | [email protected]

NETHERLANDSP.O.Box 10.054 | 3004 AB RotterdamInnsbruckweg 35 | 3047 AG RotterdamT: +31 10 462 4811 | F: +31 10 462 [email protected] | [email protected]

RUSSIAShabolovka Street | 34, Bldg. 2 | 115419 MoscowT: +7 495 617 10 86 | F: +7 495 913 97 [email protected] | [email protected]

CHINARoom 1003, Sunjoy Mansion | No. 6 RiTan Rd.Chao Yang District | Beijing 100020 T: +86 10 650 72236 | F: +86 10 650 [email protected] | [email protected]

INDIA1036 Regus | Trade Center, Level 1Bandra (E) - 400 051 | MumbaiT: +91 22 40 700 447 / 700 | F: +91 22 40 700 [email protected] | [email protected]

MIDDLE EASTA1 Quds Street, A1 Tawar road | LIU#H13 Dubai Airport FreezoneNear Dubai Airport (terminal 2) | P.O.Box #54781 | Dubai, UAE T: +971 04 2947 995 | F: +971 04 2395 [email protected] | [email protected]

SOUTH KOREA#621 World Vision Building | 24-2, Youido-dongSeoul 150-010 T: +82 2785 3900 | F: +82 2785 [email protected] | [email protected]

THAILAND26th Floor, M. Thai Tower | All Seasons Place87 Wireless Road | Lumpini, Phatumwan | Bangkok 10330T: +66 2627 9410 | F: +662627 [email protected] | [email protected]

PAC Authorized Representatives are also located in most countries worldwide. For more information visit www.paclp.com

Ordering Information

CCG6652A M3 REFORMULYZER ON 120V 7890 GC

CCG6652B M3 REFORMULYZER ON 200V 7890 GC

CCG6652C M3 REFORMULYZER ON 230V 7890 GC

CCG6652.100 KIT, SPARE PARTS M3 REFORMULYZER ON 120V 7890 GC

CCG6652.200 KIT, CONSUMABLE PARTS M3 REFORMULYZER ON 120V 7890 GC

Analysis Information

Sample Matrix Gasoline and Gasoline Blending Feedstocks • Reformate• C4 streams• Straight naphtha• FCC naphtha• Alkylate• Isomerate• Oxygenates.

Analysis Modes PNAExtended PNAPIPNAPONAPHONAPIONA PIANOPIHONAOPNAWinterspec

Separation range: (varies per method)

Paraffins C4-C11Olefins C4-C10Naphthenes C5-C11Aromatics C6-C12Oxygenates C1-C6

Standard Method Compliance

ASTM D5443, D6839EN 14517IP 526, IP 566 EN ISO 22854

Utilities Requirements

Carrier gas Helium (99.999%)FID fuel Hydrogen (99.999%) and AirCooling Compressed dry AirSystem Power 110 - 230 Volts

Accessories Included

Testing DocumentationOperating manualCalibration saamplesReference samplesStartup KitCarrier Gas FiltersOven Exhaust deflectorFactory plumbing for quick installation

SPECIFICATIONS

AC Analytical Controls® by PAC,has been the recognized leader in chromatography analyzers for gas, naphtha and gasoline streams in crude oil refining since 1981. AC also provides technology for residuals analysis for the hydrocarbon processing industry. Applications cover the entire spectrum of petroleum, petrochemical and refinery, gas and natural gas analysis; ACs Turn-Key Application solutions include the AC Reformulyzer, SimDis, HiSpeed RGA and DHA instruments.