43
DAIKIN ALTHERMA LOW-TEMPERATURE HEAT PUMP The natural choice Preliminary version

The natural choice - szegedklima.hu

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The natural choice - szegedklima.hu

DAikin AlthermA

low-temperAture

heAt pump

The naturalchoice

preliminary version

Page 2: The natural choice - szegedklima.hu

Brand newlow TemperaTure

4Daikin alTherma

the new DAikin AlthermA

low-temperAture heAt pump,

An innovAtive proDuct rAnge,

DesigneD to Deliver only the best

in climAte control

Page 3: The natural choice - szegedklima.hu

you

Page 4: The natural choice - szegedklima.hu

Brand newlow TemperaTure

4Daikin alTherma

the new DAikin AlthermA

low temperAture heAt pump,

An innovAtive proDuct rAnge,

DesigneD to Deliver only the best

in climAte control

Page 5: The natural choice - szegedklima.hu

p. 6

p. 22

Best seasonal efficiencies, providing the highest savings on running costs

• excellentCOPratingsforincentiveandcertificationschemes

• noneedfororonlyverylimiteduseofelectricalassistance• bestefficienciesachievedwithinthemostrelevant

temperaturerange

perfect fit for new builds, as well as for low-energy houses

• custom-madeproductforverylowheatloads• buildtowithstandmostseverewinterconditions• heating,coolinganddomestichotwaterinonesystem

benefits

Page 6: The natural choice - szegedklima.hu

6

p. 30

p. 14

integrated indoor unit: best solution for domestic hot water for installer & customer

• allcomponentsandconnectionsfactory-made• verysmallinstallationfootprintrequired• minimumelectricalinputwithconstantavailabilityofhotwater

new user interface: high functionalities, easy to use

• self-explanatorycontrollerforeasyandquickcommissioning• possibilityofpreparinganduploadingfieldsettingviaaPC• feedbackonoperationconditionsandenergyconsumption

Page 7: The natural choice - szegedklima.hu

Best seasonal

Withmanyyearsofair-to-waterheatpumpexperienceand over150,000unitsinstalledthroughoutEurope,wecontinuouslystrivetooptimiseDaikinAltherma’sperformance.Thisisachievedby a constant focus on limiting electrical inputsduringeach newproduct-development-process,resultinginfurtherreducing therunningcosts.

providingthe highest savings on running costs

Page 8: The natural choice - szegedklima.hu

Best seasonalprovidingthe highest savings on running costs

5

efficiencies

Page 9: The natural choice - szegedklima.hu

6

high heAt pump efficiencies At All outDoor AnD wAter temperAtures

1.

Each capacity class has an individually sised compressor,dimensioned toprovideoptimal efficiencies per capacityrange.Thisavoidshavinganover-dimensionedcompressor,leadingtolowerseasonalefficiencies.

For example, the compressor of the new 4kWclass is designed to work at optimal frequencies,deliveringthelowcapacitiesneededbyhouseswith lowheatloadsmoreefficiently.

In addition to its efficient compressor range, the DaikinAltherma optimises efficiency at all outside and watertemperatureswiththeuseof:

• a pressure sensor for detailed measurement ofcondensing pressure level to evaluate the optimalamountofsubcool.

• an individual dimensioned plate heat exchanger percapacityclass,toofferoptimalefficienciesper capacityrange.

• Low-capacity 4-8kW range is equipped with swingcompressor:integrationofmainmovingpartsinonecomponent,assuringnoabrasionandnorefrigerantleakages, guaranteeing optimal reliability andefficiency;

• High-capacity11-16kWrangeisequippedwithscrollcompressors:quiet,compactandrobust,guaranteeingoptimaloperational reliability (novalvesandbuilt-inswing-link coupling) and efficiency (through a lowinitialflowandaconstantcompressionratio).

heat pump efficiency = SCop = heatingoutput/year

electricityinput/yearThetotalheatingoutputperyear isdefinedbytheclimaticconditionsandhousespecificationsand is independent tothetypeofheatingsystem.Thetotalelectricityinputperyearisthe criticalparameterasthisiswhatthecustomerpaysfor.

Theseasonalefficiency(alsocalledSCOP)ofaheatpumpistheaverageefficiencyoverawholeyear,takingintoaccountspecificclimaticconditionsandhousespecifications(heatload,requiredwatertemperatures,etc.).ThismeanstheSCOPvaluecanbeseenastherealoperatingefficiencyofaheatpumpsystem,takingintoaccountalltherequiredinputsandspecificapplicationconditions.

swing scroll

DaikinAlthermalowtemperatureusesarangeofefficientcompressors,limitingelectricalcompressorinputstoitsmaximum.This results inoptimal efficiencies at several ratedconditions, providingexcellent ratings, complyingwithincentiveandcertificationschemes (e.g.EPBDregulations)throughoutEurope.

Page 10: The natural choice - szegedklima.hu

7

high heAting cApAcities Down to low outsiDe temperAture

2.

DaikinAltherma low temperature maintains itshighheatingcapacitiesdown to lowoutdoor temperatures. Theelectricalback-upheaterassistanceisnolongerrequiredoronlyverylimited.Thesehighheatingcapacities,availableon thewholeDaikinAltherma lowtemperature4kW-16kWrange,areachievedthankstothecombinationof:

• Optimisedcontrolstoachievehigherfrequencyofuseatlowoutdoortemperatures• Liquidinjectiontoavoidtoohighdischargetemperatureswhenhighwatertemperaturesarerequired

atlowoutdoortemperatures• Perfectlydimensionedplateheatexchangerstomaximisetheheatexchangesurface

-15 -10 -5 0 5

18

16

14

12

10

8

6

4

2

0

Heatingcapacity(kW)

Outsidetemperature(°C)

less Buh required

Typical application:

• Location:Munich• Designtemperature:-15°C• Heatload:14kW• Heatingofftemperature:16°C

StandardHPsystemerlQ016cAHeatload

A comparison is made between a standard low-temperature air-to-waterheat pump system, and the new Daikin Altherma units (ERLQ-C range – 11-16kW):

• Newrangedeliversaround3kWadditionallyat-15°C(+40%)• Equilibriumtemperatureshiftsfrom-5°Cto-10°C• Operationofelectricalassistanceisverylimited

ThisisillustratedbyatypicalapplicationinMunich

Page 11: The natural choice - szegedklima.hu

8

DAikin inverter compressors with high moDulAting rAnge

3.

Whentheheatloadislowerthanthemaximumcapacityoftheheatpumpsystem,thecompressorcanturninpartialloadoperation.Thisreducedcompressorfrequencyresultsin:

• Highercompressorefficiencyinpartialloadoperation• Deliveredcapacitiesexactlymatchingtheactualheatingdemandofthebuilding• Obtainingthecapacitiesneededwithminimumenergyconsumption• Lesson/offoperation,increasingtheoperationlifecycleofthecompressor

ThenewDaikinAlthermalowtemperaturehasahighmodulatingrange,meaningthecompressorcanmodulatedowntolowfrequenciestooffer thehighestefficienciesovertherelevanttemperaturerange.Eachinvertercompressorhasacertainmaximumandminimumfrequency,andworksinbetweentheoptimaloperationareawiththehighestoperatingefficiencies.Thisisillustratedbythegraphbellow.

Heatload>maxcapacity:fullload Compressorwilloperateat100%frequency, withadditionalelectricalassistanceifrequired

max capacity > heat load > min capacity: partial load compressor will reduce its frequency delivering the capacities required by the house, with high operating efficiencies

Mincapacity>heatload:partialloadwithon/offCompressorwillworkatitsminimumfrequencywithhighoperatingefficiencies,butswitchingon/offtodeliverthecapacitiesrequired

1

2

3

heatloadline ERLQ006CAmaxcapacity

ERLQ006CAmincapacity

1 2 3-7 -5 -3 -1 1 3 5 7 9 11 13 15

8

7

6

5

4

3

2

1

0

Capa

city(kW)

Outdoortemperature(°C)

max frequency

wide optimal operation area at relevant outside temperature (-2°C to 10°C)

min frequency

optimal operation area

Page 12: The natural choice - szegedklima.hu

9

Typical application:

• Location:Paris• Designtemperature:-7°C• Heatload:7kW• Heatingofftemperature:16°C

Efficient partial-load operation is especially important for the temperaturerangewherethehighestheatoutputisrequired.Typically,80%ofthetotalheatoutput is required in anoutdoor temperature rangeof -2°C to10°C.Achievinghighefficienciesinthistemperaturerange,contributesstronglytohighseasonalefficiencies.

• Largestpartofheatoutputdeliveredatoptimalefficiencies• Lesson/offoperationwhenheatloadbecomeslowerthantheminimum

capacitytheheatpumpcandeliver,optimisingefficiencyandcomfort

Operationhours kWhheatoutput Taswitchoff

Heatoutput(kWh)

-10 -2 0 10 20 30

HighefficiencycrucialinTarange-2C°to10°C

Heatload7kW

1600

1200

800

400

0

1000

800

600

400

200

0

Outdoortemperature(°C)

Operationhours(h)

• Modulatingrangedoubledvsstandard air-to-waterheatpumps

• Newrangedeliversaround1kWadditionalin full-loadconditionat-7°C(+25%)

heatloadlinestandardHPmaxcapacitystandardHPmincapacityERLQ006CAmaxcapacityERLQ006CAmincapacity

-7 -5 -3 -1 1 3 5 7 9 11 13 15

Outdoortemperature(°C)

optimal operation area

too small

8

7

6

5

4

3

2

1

0

Capa

city(kW)

-7 -5 -3 -1 1 3 5 7 9 11 13 15

Outdoortemperature(°C)

wide optimal operation area at

relevant Ta (-2°C to 10°C)

8

7

6

5

4

3

2

1

0

Capa

city(kW)

Standard heat pump Daikin altherma

The partial load operation and optimal operation area can be illustrated by atypicalapplicationinParis

Page 13: The natural choice - szegedklima.hu

smArt heAting controls4.

1 Weather-dependentset-pointcontrol:DaikinAlthermamaximisesefficiencyateveryoutdoortemperaturethroughitsweather-dependentset-pointcontrol.Thiscontrollogicwillalwayskeepthewatertemperaturesaslowaspossible,tomaximisetheheatpumpefficiencyforeachspecificoutdoortemperature.Thisresultsin:

• Higherheatpumpefficiencywithlowerwatertemperatures• Nounnecessaryoverheating,therebydeliveringthetemperaturesrequired• Continuousheatingatlowerwatertemperatures,providingstableroomtemperatures

2 Inverter technology: lowering thecompressor frequencywith increasingoutdoor temperatures, thus increasing theefficiency

Theexampleshownisforatypicalapplicationusingunder-floorheating:

• Awatertemperatureof38°Cisrequiredatadesign temperatureof-10°C(1)

• Awater temperatureofonly25°C is requiredat a spaceheatingofftemperatureof16°C(2)

• For temperaturesbetween -10°C and16°C, theDaikinAlthermaunitcalculates the required water temperature, to guarantee maximumefficiency,withcontinuousheating,ateachoutdoortemperature. -10°C 16°C

Ta

1

2

Floating set-point

38°C

25°C

t set-point(Tlwc)

The combined effect of the Daikin Altherma weather-dependent set-point control and the Daikin Altherma invertercompressorsmaximises the efficiency at each outdoor temperature, assuring stableroomtemperatures.

10

Page 14: The natural choice - szegedklima.hu

11

limiting electricAl inputs of AuxiliAry components

5.

Inadditiontolimitingtheelectricalinputofthecompressorandtheelectricalback-upheater,Daikinpaysspecialattentiontolimitingelectricalinputsofauxiliarycomponents.Thisalsocontributestothehighseasonalefficienciesachievedby theDaikinAlthermarange.

• Factory-mountedhighefficiencycirculatingpumpalreadyqualifyingforfutureregulations(ErP2015)withanA-energylabel(EEI≤0.23)

• NostandbylossesofinverterdrivePCB,loweringelectricityconsumptionduringstandbymode• Nobottomplateheaterneeded on4-8kWclass• Low-capacitybottomplateheateron11-16kWclass(ERLQ-Cseries),onlyoperatingduringdefrostcycles,resultsin90%

lesselectricityconsumptionwhencomparedwithstandardthermostaticcontrolledbottomplateheaters.

applicable units: 4-8kw location: munich (Germany)

advantage compared to tradional hp system Conditions operating hours

per year Yearly benefit

Highefficiencycirculatingpump 45Wless(TBC)* accordingtoEN14511 5300hours 240 kwh

NostandbylossesinverterdrivePCB 20w less instandbymode 3400hours 70 kwh

Nobottomplateheater 60w less whenTabelow4°C 2800hours 170 kwh

applicable units: 11-16kw location: munich (Germany)

advantage compared to tradional hp system Conditions operating hours

per year Yearly benefit

Highefficiencycirculatingpump 65Wless(TBC)* accordingtoEN14511 5300hours 340 kwh

NostandbylossesinverterdrivePCB 20w less instandbymode 3400hours 70 kwh

Lowcapacitybottomplateheater 60Wless+smartlogic whenTabelow4°C 2800hours 160 kwh

*preliminarydata

Page 15: The natural choice - szegedklima.hu

12

TheDaikinAlthermalowtemperatureisfullyoptimisedtofulfill theefficiency, comfort and applicationneedsofnewlybuilthouses.Inaddition,theextendedproductrangenowofferstheperfectsolutionforlow-energyhouses,evenforverylowheatloads.

perfect fit for new builds,low energy houses

as well as for

Page 16: The natural choice - szegedklima.hu

perfect fit for new builds,

13

Page 17: The natural choice - szegedklima.hu

14

ThenewDaikinAlthermalowtemperatureisdesignedtomeettherequirementsofnewlybuiltandlow-energyhousescharacterisedbylowheatloads.

Thelowcapacity4kWunitwithitshighmodulatingrangeoffersoptimalefficiencyinmostrelevantoutdoortemperaturerangesbycombiningcompressorsandplateheatexchangersthathavebeenspecificalydesignedforsmallerheatloads.

optimiseD unit for low heAt loADs1.

The new-build house market in Europe is moving towardssmallerheatloads,dueto:

1. Growingimportanceoflow-energyhouses2. Strengthenedlegislationonenergyconsumptionin

newresidentialconstructions(e.g.EPBDregulations)3. Decreasingsizeofnew-buildhouses4. EUmemberstatesplanningtoreachtheir

20-20-20targets

Page 18: The natural choice - szegedklima.hu

15

Outdoortemperature(°C)

optimal operation area too small and not in relevant Ta (-3°C to 7°C)

8

7

6

5

4

3

2

1

0

Capa

city(kW)

heatloadlineStandardHPmaxcapacityStandardHPmincapacityERLQ006CAmaxcapacityERLQ006CAmincapacity

-7 -5 -3 -1 1 3 5 7 9 11 13 15 -7 -5 -3 -1 1 3 5 7 9 11 13 15

Outdoortemperature(°C)

wide optimal operation area at relevant Ta (-3°C to 7°C)

8

7

6

5

4

3

2

1

0

Capa

city(kW)

Low-energyhouseshavealowerspaceheatingofftemperature(12°C)thannormalinsulatedhouses(16°C).Thismeansthatthemostrelevantoutdoortemperature-range for low-energyhouses, shifts towards lower temperatures.A typical low-energyhouse(seedetailsbelow)has80%ofitstotalheatoutputintheoutdoortemperaturerangeof-3°Cto7°C.

Withthenew4kWunit,DaikinAlthermalowtemperatureoffersafullproductline-upwithaspecificallydimensionedheatpumpsystem(compressor,modulatingrange,plateheatexchanger,…)todelivertherequiredcapacitiesforthehouse,withthebestpossibleefficiencies.

ThenewDaikinAltherma4kWunitisdevelopedanddimensionedtoreachoptimalefficienciesatthemostrelevanttemperaturerange,thankstoitshighmodulatingrange.

Typical application:

• Location:Paris• Designtemperature:-7°C• Heatload:4kW• Heatingoff

temperature:12°C

Operationhours kWhheatoutput Taswitchoff

-10 -5 0 5 10 15 20 25 30

HighefficiencycrucialinTarange-3C°to7°C

Heatload4kW

800

700

600

500

400

300

200

100

0

1000

900

800

700

600

500

400

300

200

100

0

Outdoortemperature(°C)

Heatoutput(kWh)Operationhours(h)

Thisisillustratedbythepracticalexamplebelow

Standard heat pump Daikin altherma

Page 19: The natural choice - szegedklima.hu

16

mAximum comfort2.

DaikinAltherma lowtemperature: onesystemforoptimal year-roundcomfort

optimal comfort conditions:Keeping the house at the desired temperature thewholeyear,withbothheatingandcoolingpossible• Only one outdoor unit required to provide heating

andcooling• Same emitters can be used for heating and cooling

(Daikinheatpumpconvectororunder-floor system)

Stable room temperatures: The combined effect of the Daikin inverter compressorsand weather-dependent set-point control guarantees acontinuousheatingoperation.

Withhigheroutdoor temperature, thewater temperaturewill be lowered and the frequency of the compressorreduced,inordertoensurea continuousheatingoperation,providingstableroomtemperature.

room thermostat: TheDaikinuserinterfacecanbeinstalledinthelivingroomusingtheroomthermostatfunction,whichcanadditionallylowerorraisetheset-pointwatertemperatureinfunctionofactualroomtemperature,toevenbettermatchtheset-pointroomtemperature.

Page 20: The natural choice - szegedklima.hu

17

balancing vessel

Under-floorheating

mixingvalve

Lowtemperatureradiator

45°C

35°C45°C

Under-floorheating

All types of heAt emitters possible3.

25°C35°C

Heatpumpconvector 35°C45°C

TheDaikinheatpumpconvectorisspecificallydesignedtoofferoptimalefficienciesandcomfortforresidentialapplications.

• Smalldimensionscomparedtolow-temperatureradiators• Lowsoundlevel,optimalforbedroomapplications• High-capacitycoolingwithwatertemperaturesdownto6°C

Thankstothemultipleset-pointfunction,acombinationofdifferenttypesofheatemittersoperatingatdifferentwatertemperaturesispossible.Whenthereisnoheatingrequestfromthehighertemperaturezone,thewatertemperaturewill be lowered to the temperature required by thelow temperature zone. This ensures keeping the watertemperaturesaslowaspossible,whilealwaysguaranteeingthehighestefficiency.

Tset Thermostatus

Space1 low-temperatureradiator

45°C off on on off

Space2 under-floorheating

35°C off on off on

Heatpump off 45°C 45°C 35°C

TheDaikinAlthermalowtemperaturehasanoperationrangeupto55°Cleavingwatertemperature,allowingforconnectiontoalltypesoflow-temperatureheatemitters.

40°C55°CLowtemperatureradiators

700mm

ConsoleDaikin

600mm

600mm

2000mmRadiateur standard basse température

Page 21: The natural choice - szegedklima.hu

18

DAikin AlthermA is suitAble for All climAtes, even withstAnDing severe winter conDitions

4.

Daikinisrenownedfor itsknow-howrelatedtofrostprotectiononitsheatpumprange. Theoutdoorunitsarespecificallydesignedtoavoidicebuild-upproblems,eveninthemostseverewinterconditions.

Daikin Altherma low temperature has a guaranteedoperation down to an outside temperature of -25°C.Thisensuressufficientheatpumpoperationforeventhecoldestclimates.

1.The4-8kW rangeof DaikinAlthermahasa specificallydesignedcasingtoavoid the riskof ice formationontheoutdoorunitcoil.

• The outdoor unit has a free hanging coil,ensuring no ice accumulates in the lower part of theoutdoor unit. This is key to offering appropriatefrost protection and has the additional advantagethat no electrical bottom plate heater is required.

• The discharge grill is also specifically designed toavoidiceaccumulation.

This adequate frost protection results in one productofferingthroughoutEurope,fromthesouthofSpaintothenorthofFinland.

Page 22: The natural choice - szegedklima.hu

19

hot gas pipe

Side plate

2. The 11-16kW range of Daikin Altherma (ERLQ-C) hasspecificfrostprotectiontoavoidtheriskoficeformingontheoutdoorunitcoil.

• Hotgaspass:hotgaseousrefrigerantcomingfrom the compressor runs through the bottom platetokeepthebase freeof iceandall thedrainholes open

• Sub-cool pass: before the refrigerant pipe is splitby the distributor to the hairpins, the refrigerantpasses through the bottom of the coil to keep thislowerpartfreeofice

Sub-cool passsealing

Only a small capacitybottomplateheater is installed(35W) on the ERLQ-C range, with smart operationlogic only operating during defrost cycles. This savesaround 90% of electricity consumption compared toatraditionalheatpumpsystemwithathermostaticallycontrolledbottomplateheater.

distributor

Page 23: The natural choice - szegedklima.hu

best solution for domestic hot water – for installer & customer

integrated indoor unit:

20

Page 24: The natural choice - szegedklima.hu

21

ThenewDaikinAlthermalowtemperatureintegratedindoorunitis anall-in-onefloor-standingheatpumpunitincludingthedomestic hotwatertank(availablein180land260l).Thismakesittheeasiest and fastest installationwhendomestichotwaterisrequired, andprovidesthe highest domestic hot water heating efficiency and comfortfortheenduserinacompact,sleekdesign. Whendomestichotwaterispreferredincombinationwith theDaikinAlthermalowtemperature,the integrated indoor unit is the best solution, for the installer and the end user! Awall-mountedindoorunitisavailableaswell,toofferthebestsolutioninspecificsituations,e.g.whennodomestichotwaterheatingisrequiredoracombinationwiththermalsolarenergyispreferred.

integrated indoor unit:

all in one

Page 25: The natural choice - szegedklima.hu

170cm

22

60cm

74cm

eAsiest AnD fAstest instAllAtion, Domestic hot wAter tAnk incluDeD

• Thestainlesssteeldomestichotwatertank is includedin the unit, with all connections between heat pumpmodule and tank factory made. This allows for a fastinstallation compared to a traditional set-up (wall-mountedwithseparatedomestichotwater tank)withonlywaterandrefrigerantpipestobeconnected.

• All hydraulic components are included (circulatingpump,expansionvessel,back-upheater,etc.Noneedtolookforthirdpartycomponents.

• Theelectric PCBboard andhydraulic components areaccessiblefromthefront.Thisensureseasyserviceabilityand avoids the risk of any damage to electricalcomponentsduetowaterleakages.

• Allwaterandrefrigerantconnectionsareat thetopofthe unit, assuring easy connection and accessibility. This means no connections are required at the backof the unit, resulting in a lower installation footprint.

1.

Components areaccessible fromthefront

Page 26: The natural choice - szegedklima.hu

23

compAct inDoor unit with sleek Design2.

2

Smallerinstallationfootprint.Noside/backclearancesrequired

74 cm

60 cm95 cm + X

58cm 37cmx

hydrobox

Dhw tank

VS

Thankstotheall-in-onedesign,theinstallationspaceisminimisedbothintermsoffootprintandheight

Compared to the traditional split-up version for a wall-mounted indoor unit and separate domestic hot water tank, theintegratedindoorunitgreatlyreducestheinstallationspacerequired.

1

3

4

Small footprint: with a width of only 60cm and a depthof74cm,theintegratedindoorunithasasimilarfootprintcomparedtootherhouseholdappliances.

Smallinstallationfootprint:nosideclearancesarerequired,and no space is required behind the unit for the piping,asthepipingconnectionsareatthetop.Thisresultsinaninstallationfootprintofonly0.44m².

Lowinstallationheight:boththe180land260lversioncomewithaheightof1.7m.Therequiredinstallationhightislessthan2m,takingintoaccount30cmforinstallingthepiping.

Thecompactnessoftheintegratedindoorunitisemphasisedbyitssleekdesignandmodernlook,easilyfittingwithotherhouseholdappliances.

60 cm

Space reduced

bymorethan 30%

Page 27: The natural choice - szegedklima.hu

24

BESTSOLUTIONFORDOMESTICHOTWATERHEATING:high efficiency – high comfort

3.

DaikinAlthermausesasmartcontrolprincipletoheat-upthe domestic hot water tank, maximising efficiency andcomfort for the end-user.The combination of the reheatand schedule function guarantees minimumelectricalinputandensurestheconstantavailabilityofhotwater.• Schedulefunction:heat-upthetankataspecifiedtime

during theday, up to apre-set tank temperature.Thisaction can be repeated four times per day, with thepossibility of setting two different tank temperatures(storagecomfortandstorageeconomic.)

• Reheat function: when the tank temperature goesbelowa specifiedminimumreheat temperature,DaikinAlthermaswitchesautomaticallytodomestichotwaterheating,heatingupthetanktoaspecifiedmaximumreheattemperature.

• These two control functionalities can be usedindividually,butalsoincombinationtoprovidethebestefficiencyandmaximumcomfort. Theschedulefunctioncanbeusedtoheatupthetankduring the night with the low electricity tariff, up to a relatively low tank temperature (e.g. 50°C avoidingtheuseofelectricalassistance).Whenhigherhotwaterconsumptionoccursduringtheday, loweringthetanktemperature to the minimum reheat temperature, theheatpumpwillswitchautomaticallytodomestichotwaterheatingwiththereheatfunctiontoguaranteetheconstantavailabilityofhotwater. Thankstothelargecoilsurfaceofthetank(coilsurfaceof 1.56m2) heating up the tank with the scheduledfunctionorreheatfunctionoccursveryquickly.

The domestic hot water tank of the integrated indoorunit is equippedwith thick polystyrene insulationwhichresults in 50% less heat loss compared toa standard insulated tank.This results inhighsavingsonrunningcostsaslessenergyisrequiredforthenextheat-upcycle.

• Heat loss from the180l tank: only 1.2kWhperday(temperaturedifferenceof45°Cbetweentankandroomtemperature).Thisresultsinadifferenceof440kWhperyearcomparedtoastandardinsulatedtank.

DaikinAltherma lowtemperaturecanheat thedomestichotwatertankuptohightanktemperatureswithheatpumpoperationonly.Thisavoidstheuseofelectricalassistanceforheatingupthehotwatertank,maximisingtheefficiencyofhotwaterproduction.

• Tank temperaturewithheatpumponlyoperation: up to 55°C with the 11-16kW unit (ERLQ-C range) andupto50°Cwiththe4-8kWunit.Tanktemperaturecanbefurtherraisedto60°Cwiththestandardback-upheateroftheheatpumpmodule,orupto80°Cwithanoptionalboosterheaterinthetank.

Thisresultsin highhotwatervolumes.Followingvolumescanbeachievedwithonlyoneheat-upcycle.

• Hotwatervolumeof300lisavailableat40°C,sufficientfor six showers, without any electrical assistancerequired (260l tank, tank temperature50°C,coldwatertemperature10°C,oneheat-upcycle)

• Thehotwatervolumecanbefurtherincreasedto375lusing the standard back-up heater (260l tank, tanktemperatureupto60°C).

Page 28: The natural choice - szegedklima.hu

25

4.

Thewall-mountedindoorunitis theperfectsolution,incertainsituations

1.WhennodomestichotwaterisrequiredincombinationwiththeDaikinAlthermasystem:

• Allhydrauliccomponentsareincludedintheheatpumpunit(circulatingpump,expansionvessel,back-upheater,etc),noneedtolookforthird-partycomponents

• All hydraulic components and the PCB board, areaccessiblefromthefrontforeasyserviceability

• Compactunit:height88cm,width48cm,depth37cm• Small installation space as no side clearances are

required• Modern outlook easily fits in with other modern

householdappliances.

2.Thewall-mountedindoorunitcanbecombinedwith aseparatedomestichotwatertank.

• stainlesssteeltank:150l,200lor300l• enameltank:150l,200lor300l.

wAll-mounteD inDoor unit incluDing All hyDrAulic components

3. ConnectiontoDAIKINsolarsystem

• Pressurisedthermalhotwater• Separatedomestichotwatertankcanbeused

(stainlessandenamel)• Specificdesignedsolarkitselectsmostrelevantsource

(solar or heat pump) to heat up the tank, assuringoptimalefficiencyandmaximumcomfort.

Page 29: The natural choice - szegedklima.hu

26

high functionalities

26

easy to usenew user

Page 30: The natural choice - szegedklima.hu

27

TheDaikinAlthermalowtemperatureisequippedwithanewuser-interface.Commissioning,servicingandday-to-dayoperationbecomestraightforwardthemulti-lingualandgraphicalinterfacethatprovidesfull-textrepresentation,easymenunavigationandintelligent controlfeatures.

interface

Page 31: The natural choice - szegedklima.hu

28

28

Quick AnD eAsy commissioning1.

Atthefirststart-up,aquickconfigurationwizardwillguidetheinstallerthroughthecommissioningprocess.Througha seriesof shortquestions, the set-upofbasicparameterswill automaticallybecompleted.Fine-tuning theseparametersremainspossibleusingthemenu-basednavigation.Asaresultofthequickconfigurationwizard,onlytheparametersettingsrelevanttotheinstallationwillbeshowninthemenus.Theirrelevantparameterswillbehiddenandthusinaccessible.

TheparameterscanbedownloadedtoaPCasaback-up,orbeduplicatedtoothersimilarinstallations.Ifpreferred, theparametersettingscanalsobepreparedonbeforehandanduploadedtotheunitsduringcommissioning.

Before theactual test-runof theunit, anactuator testmodeallowsall thewiredcomponents tobeactivatedonebyone.Thisallowsforaquickandeasycheckofallconnectionsandwiringsmadetoensureacorrectoperation.Anautomaticscreed-drying functioncanbeactivated toproceedthroughagradualheat-upofanUnder-floorheatingsystemtoavoidcracksinthefloorduringthefirstheat-up.Individualandeasy-to-programmescheduletimers for heating, cooling, domestic hotwater operation and recirculation noise-sensitive operation and electricalboosterheaterallowtoadjusttheoperationoftheunittomatchtheend-user’stypicaldailyschedule.

Afterthecommissioning,accesstotheinstaller’smenucanberestricted(manuallyorautomaticallyafteronehour)toavoidwrongmanipulationoftheunitbytheend-user.

Page 32: The natural choice - szegedklima.hu

29

Graphicalscreen withbacklight

On/Off

Menuback

NavigationalbuttonsConfirm

home

Errorinfo

eAsy serviceAbility

room temperAture control functionAlity

user-frienDly with intuitive controls

2.

3.

4.

In case something goes wrong, full-text errormessageswillguidetheend-usertotakeappropriateactiontotryandresolvetheproblem.Iftheproblempersistsandasite intervention isnecessary, theservice engineerwillbeabletoreviewthelast20erroroccurrences.

Detailed information on the operationalconditionsof theunit, suchas the runninghoursofthedifferentelements,operatingtemperaturesornumberof starts, can easily be read out from the extended end-user’smenu.

TheuserinterfaceitselfisequippedwithatemperaturesensorandcanbeinstalledremotelyfromtheDaikinAlthermalowtemperatureindoorunit.

• Installedontheunit,itwillallowquickandeasyaccesstotheunit’soperatinginformationandsettings.• Installed remotely (e.g. in a living room) itwill also act as a room thermostatwithmore advanced features than

astandardroomthermostat,resultinginmorestableroomtemperatures,increasedefficiencyandoperationlifecycle.Asecondoptionalinterfacecanstillbeinstalledontheunitforservicepurposes.

Inthedetaileddisplaymode,thelargegraphicaldisplayoftheuserinterfacedisplaystheactualroomtemperatureandtheoperationmodeoftheunit.Dependingontheend-user’spreference,asimplifiedbasicdisplayisavailablethatshowsjusttheactualroomtemperatureandonlyallowstheroomtemperatureset-pointtobechanged.

Usersettingscanbeaccessedthroughanintuitiveandself-explanatorymenu.Thismenuwillalsogiveaccess to additional information such as theenergy consumption and heat production of thesystem,splitupbetweenheating,coolinganddomestichotwateroperation,enablingclosemonitoringoftheunit’sefficientoperation.

Page 33: The natural choice - szegedklima.hu

100% 100%100% 100%

61%

27%

53%

21%

30

exAmple on running cost AnD co2 compArison 1.

heat pump in practice

The Daikin Altherma low temperature heat pumpoperates much more efficiently than a traditional fossil-fuelboiler.Comparedtoacondensinggasboiler,installing a Daikin Altherma low temperature results in a runningcost reduction of 39%. The savings are even up to 47%whencomparingtheDaikinAlthermalowtemperaturetoacondensingoilboiler.

Since aheatpumponly indirectly emitsCO2, the systemproduces up to 79% less CO2 compared to a traditionalfossil-fuel boiler. When the electricity used to run the heat pump is gained fully from renewable energysources, the heat pump is CO2 neutral. Thus, installing aDaikinAlthermalowtemperaturecontributesactivelytoabetterandcleanerenvironment.

*DatacalculatedbytakingintoaccountBelgianconditions:Averageenergyprices2007-2011,CO2emissionfactorforelectricity,productionandBelgianclimateconditions.

ReductiononCO2Lessrunningcosts

gas gasHeat pump

Heat pump

Heat pump

Heat pump

oil oil

Page 34: The natural choice - szegedklima.hu

31

eco-cAlculAtor2.

simulAtion softwAre3.

Daikinprovidesaweb-basedtooltogiveaquickestimationofsavingsonrunningcostsandsavingsonCO2emissions.Basedonafewinputsfromthecustomer(location,housetype,floorarea,numberofpeople),acomparisonismadebetween the Daikin Altherma heat pump system andtraditional heating systems. This comparison includesthe space heating and domestic hot water heating.This isavailable forbothnewbuildsandrefurbishmentapplications.

TheDaikinAlthermasimulationsoftwareprovidesforeveryspecificapplicationandappropriateheatpumpselection,takingintoaccounttheneedsofthebuildingandspecificclimate data. An installer can provide the following data:

• houseapplication:heat/cool load,water temperatures,powersupply

• climateconditions:location,designtemperature• domestichotwaterrequirements:tankvolume,

material,solarconnection• preferences:“heatingoff“temperature,

nightsetbackfunction

Based on the specific house and location details, thesoftware provides a full dimensioning assuring a correctmaterialselection.

Aswell as a fullmaterial selection, the softwareprovidesdetailedinformationfortheinstallerandtheend-user,onthe expected outcome of the specified Daikin Althermaunitforitsspecificapplicationandclimate:

• seasonalefficiencyoftheheatpumpsystem• amountofback-upheateroperation• energyconsumptionandenergycostpermonth• savings on running costs compared to traditional

heatingsystems

Allthisinformationwillbesummarisedinadetailedreport.

Page 35: The natural choice - szegedklima.hu

32

oudoor unit: 4-6-8 kw

heat pump convector

4. integrAtion for A totAl solution

Whetheryouhaveanewlybuilthouseorliveinanexistinglowenergyhome,theDaikinAlthermalowtemperaturesplitallowsforcompletelyintegratedcomponentsfortotalclimatecontrol.Whetheryouoptfortheintegratedfloorstanding indoor unit to provide heating and domestichotwaterorgoforawallmountedindoorunit,whetheryou use under-floor heating or heat pump convectors,whether your electricity comes from the grid or from a renewable eco-friendly resource like solar power, the Daikin Altherma low temperatureisatotalsolution4you.

Page 36: The natural choice - szegedklima.hu

33

integrated indoor unit

Solar connection (optional)

under-floor heating

heat pump convector

Domestic hot water

Page 37: The natural choice - szegedklima.hu

34

heAting only

inDoor uniT *ehBh04C3V preliminarY DaTa

*ehBh08C3V preliminarY DaTa

*ehBh08C9w preliminarY DaTa ehBh016C ehBh016C ehBh016C

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 880x480x350 880x480x350 880x480x350Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.006/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801/4.572/3.603/2.764/3.405/2.706/2.207 4.501/4.35 2/3.553/2.724/3.355/2.606/2.107

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata(1)EW30°C;LW35°C;ambientconditions:10°CDB(2)EW30°C;LW35°C;ambientconditions:7°CDB/6°CWB(3)EW30°C;LW35°C;ambientconditions:2°CDB/1°CWB(4)EW30°C;LW35°C;ambientconditions:-7°CDB/-8°CWB(5)EW40°C;

LW45°C;ambientconditions:7°CDB/6°CWB(6)EW40°C;LW45°C;ambientconditions:2°CDB/1°CWB(7)EW40°C;LW45°C;ambientconditions:-7°CDB/-8°CWB

heAting & cooling

inDoor uniT *ehBX04C3V preliminarY DaTa

*ehBX08C3V preliminarY DaTa

*ehBX08C9w preliminarY DaTa ehBX016C ehBX016C ehBX016C

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 880x480x350 880x480x350 880x480x350Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Cooling Ambient Min.~Max. °CDB 10~43 10~43 10~43

Waterside Min.~Max. °C 5~50 5~50 5~50Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.00 6/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.12 6/6.157

Max. kW 3.504 5.004 6.104

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

cop 5.171/5.002/3.753/2.824/3.505 /2.746/2.227 4.801/4.572/3.603/2.764/3.405 /2.70(6)/2.207 4.501/4.352/3.553/2.724/3.355 /2.606/2.107

eer 3.318/2.31(9) 2.878/2.219 2.768/2.289

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata(1)EW30°C;LW35°C;ambientconditions:10°CDB(2)EW30°C;LW35°C;ambientconditions:7°CDB/6°CWB(3)EW30°C;LW35°C;ambientconditions:2°CDB/1°CWB(4)EW30°C;LW35°C;ambientconditions:-7°CDB/-8°CWB(5)EW40°C;

LW45°C;ambientconditions:7°CDB/6°CWB(6)EW40°C;LW45°C;ambientconditions:2°CDB/1°CWB(7)EW40°C;LW45°C;ambientconditions:-7°CDB/-8°CWB

5. technicAl specificAtions

Page 38: The natural choice - szegedklima.hu

35

heAting only

inDoor uniT *ehBh04C3V preliminarY DaTa

*ehBh08C3V preliminarY DaTa

*ehBh08C9w preliminarY DaTa ehBh016C ehBh016C ehBh016C

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 880x480x350 880x480x350 880x480x350Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.006/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801/4.572/3.603/2.764/3.405/2.706/2.207 4.501/4.35 2/3.553/2.724/3.355/2.606/2.107

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata

heAting & cooling

inDoor uniT *ehBX04C3V preliminarY DaTa

*ehBX08C3V preliminarY DaTa

*ehBX08C9w preliminarY DaTa ehBX016C ehBX016C ehBX016C

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 880x480x350 880x480x350 880x480x350Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Cooling Ambient Min.~Max. °CDB 10~43 10~43 10~43

Waterside Min.~Max. °C 5~50 5~50 5~50Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.00 6/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.12 6/6.157

Max. kW 3.504 5.004 6.104

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

cop 5.171/5.002/3.753/2.824/3.505 /2.746/2.227 4.801/4.572/3.603/2.764/3.405 /2.70(6)/2.207 4.501/4.352/3.553/2.724/3.355 /2.606/2.107

eer 3.318/2.31(9) 2.878/2.219 2.768/2.289

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

Page 39: The natural choice - szegedklima.hu

36

heAting only

inDoor uniT *ehVh04S18C3V preliminarY DaTa

*ehVh08S18C3V preliminarY DaTa

*ehVh08S26C9w preliminarY DaTa ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 1,700x600x740 1,700x600x740 1,700x600x740Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.30 2

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.006/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801 /4.572/3.603/2.764/3.405/2.706/2.207 4.501/4.352/3.553/2.724/3.355/2.606/2.107

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata(1)EW30°C;LW35°C;ambientconditions:10°CDB(2)EW30°C;LW35°C;ambientconditions:7°CDB/6°CWB(3)EW30°C;LW35°C;ambientconditions:2°CDB/1°CWB(4)EW30°C;LW35°C;ambientconditions:-7°CDB/-8°CWB(5)EW40°C;

LW45°C;ambientconditions:7°CDB/6°CWB(6)EW40°C;LW45°C;ambientconditions:2°CDB/1°CWB(7)EW40°C;LW45°C;ambientconditions:-7°CDB/-8°CWB

(1)EW30°C;LW35°C;ambientconditions:10°CDB(2)EW30°C;LW35°C;ambientconditions:7°CDB/6°CWB(3)EW30°C;LW35°C;ambientconditions:2°CDB/1°CWB(4)EW30°C;LW35°C;ambientconditions:-7°CDB/-8°CWB(5)EW40°C;

LW45°C;ambientconditions:7°CDB/6°CWB(6)EW40°C;LW45°C;ambientconditions:2°CDB/1°CWB(7)EW40°C;LW45°C;ambientconditions:-7°CDB/-8°CWB

heAting & cooling

inDoor uniT *ehVX04S18C3V preliminarY DaTa

*ehVX08S18C3V preliminarY DaTa

*ehVX08S26C9w preliminarY DaTa ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 1,700x600x740 1,700x600x740 1,700x600x740Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Cooling Ambient Min.~Max. °CDB 10~43 10~43 10~43

Waterside Min.~Max. °C 5~50 5~50 5~50Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.00(5)/4.00(6)/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.50(1)/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801/4.572 /3.603/2.764/3.405/2.706/2.207 4.501/4.352/3.553/2.724/3.35 5/2.606/2.107

eer 3.318/2.319 2.878/2.219 2.768/2.289

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata

Page 40: The natural choice - szegedklima.hu

37

heAting only

inDoor uniT *ehVh04S18C3V preliminarY DaTa

*ehVh08S18C3V preliminarY DaTa

*ehVh08S26C9w preliminarY DaTa ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 1,700x600x740 1,700x600x740 1,700x600x740Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.30 2

Nom. kW 4.501/4.502/3.503/4.104/4.005/4.006/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.501/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801 /4.572/3.603/2.764/3.405/2.706/2.207 4.501/4.352/3.553/2.724/3.355/2.606/2.107

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata

heAting & cooling

inDoor uniT *ehVX04S18C3V preliminarY DaTa

*ehVX08S18C3V preliminarY DaTa

*ehVX08S26C9w preliminarY DaTa ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w ehVh16S18C3V/S26C9w

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

Casing Colour S5730White/RAL7037 S5730White/RAL7037 S5730White/RAL7037Dimensions Unit HeightxWidthxDepth mm 1,700x600x740 1,700x600x740 1,700x600x740Operationrange Heating Ambient Min.~Max. °C -20~25 -20~25 -20~25

Waterside Min.~Max. °C 25~55 25~55 25~55Cooling Ambient Min.~Max. °CDB 10~43 10~43 10~43

Waterside Min.~Max. °C 5~50 5~50 5~50Domestichotwater

Ambient Min.~Max. °CDB -20~35 -20~35 -20~35Waterside Min.~Max. °C 25~55 25~55 25~55

Soundpowerlevel Nom. dBA 42 42 42Soundpressurelevel Nom. dBA 281 281 281

Powersupply name V3 V3 9WPhase 1~ 1~ -

ouTDoor uniT *erlQ004CV3 preliminarY DaTa

*erlQ006CV3 preliminarY DaTa

*erlQ008CV3 preliminarY DaTa erlQ011CV3/Cw1 erlQ014CV3/Cw1 erlQ016CV3/Cw1

Heatingcapacity Min. kW 1.802 2.302 2.302

Nom. kW 4.501/4.502/3.503/4.104/4.00(5)/4.00(6)/4.417 6.001/6.002/4.703/5.204/5.505/5.176/5.157 7.50(1)/7.502/5.803/5.504/7.005/6.126/6.157

Max. kW 3.504 5.004 6.104

Coolingcapacity Nom. kW 5.608/5.129 8.168/5.869 8.378/6.659

cop 5.171/5.002/3.753/2.824/3.505/2.746/2.227 4.801/4.572 /3.603/2.764/3.405/2.706/2.207 4.501/4.352/3.553/2.724/3.35 5/2.606/2.107

eer 3.318/2.319 2.878/2.219 2.768/2.289

Dimensions Unit HeightxWidthxDepth mm 735x825x300 735x825x300 735x825x300Operationrange Heating Min.~Max. °CWB -20~25 -20~25 -20~25

Cooling Min.~Max. °CDB 10~43 10~43 10~43Domestichotwater Min.~Max. °CDB -20~35 -20~35 -20~35

Refrigerant Charge kg 2 2 2Soundpowerlevel Heating Nom. dBA 61 61 62

Cooling Nom. dBA 63 63 63Soundpressurelevel

Heating Nom. dBA 48 48 49Cooling Nom. dBA 48 48 50

Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/-/- V3/1~/-/- V3/1~/-/-

*Note:greycellscontainpreliminarydata

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

no DaTa aVailaBle YeT

Page 41: The natural choice - szegedklima.hu

38

STainleSS STeel DomeSTiC hoT waTer Tank ekhwS150B3V3 ekhwS200B3V3 ekhwS300B3V3 ekhwS200B3Z2 ekhwS300B3Z2

Casing Colour neutral whitematerial epoxy-coated mild steel

weight unit empty kg 37 45 59 45 59Tank water volume l 150 200 300 200 300

material Stainless steel (Din 1.4521)maximum water temperature °C 85

heat exchanger Quantity 1Tube material Duplex steel lDX 2101

Booster heater Capacity kw 3power supply phase/Frequency/Voltage hz/V 1~/50/230 2~/50/400

enameleD STeel DomeSTiC hoT waTer Tank ekhwe150a3V3 ekhwe200a3V3 ekhwe300a3V3 ekhwe200a3Z2 ekhwe300a3Z2

Casing Colour ral9010material epoxy coated steel

weight unit empty kg 80 104 140 104 140Tank water volume l 150 200 300 200 300

material enamel coated steel acc.Din4753Tl2maximum water temperature °C 75

Booster heater Capacity kw 3.0power supply phase/Frequency/Voltage hz/V 1~/50/230 2~/50/400

wireleSS room ThermoSTaT ekrTr1

Dimensions Thermostat height/width/Depth

mm 87/125/34

receiver height/width/Depth

mm 170/50/28

weight Thermostat g 210receiver g 125

outside temperature

Storage min./max. °C -20/60operation min./max. °C 0/50

Temperature setting range

heating min./max. °C 4/37Cooling min./max. °C 4/37

Clock Yesregulation function proportional bandpower supply Thermostat Voltage V Battery powered 3x aa-lrG (alkaline)

receiver Voltage V 230Frequency hz 50phase 1~

Connection Thermostat wirelessreceiver wired

maximum distance to receiver

indoor m approx.30moutdoor m approx.100m

wireD room ThermoSTaT ekrTwa

Dimensions unit height/width/Depth

mm 87/125/34

weight unit g 215outdoor temperature

Storage min./max. °C -20/60operation min./max. °C 0/50

Temperature setting range

heating min./max. °C 4/37Cooling min./max. °C 4/37

Clock Yesregulation function proportional bandpower supply Voltage V Battery powered 3* aa-lr6 (alkaline)Connection Type wired

Domestic hot wAter tAnk

room thermostAt

Page 42: The natural choice - szegedklima.hu

39

STainleSS STeel DomeSTiC hoT waTer Tank ekhwS150B3V3 ekhwS200B3V3 ekhwS300B3V3 ekhwS200B3Z2 ekhwS300B3Z2

Casing Colour neutral whitematerial epoxy-coated mild steel

weight unit empty kg 37 45 59 45 59Tank water volume l 150 200 300 200 300

material Stainless steel (Din 1.4521)maximum water temperature °C 85

heat exchanger Quantity 1Tube material Duplex steel lDX 2101

Booster heater Capacity kw 3power supply phase/Frequency/Voltage hz/V 1~/50/230 2~/50/400

wireleSS room ThermoSTaT ekrTr1

Dimensions Thermostat height/width/Depth

mm 87/125/34

receiver height/width/Depth

mm 170/50/28

weight Thermostat g 210receiver g 125

outside temperature

Storage min./max. °C -20/60operation min./max. °C 0/50

Temperature setting range

heating min./max. °C 4/37Cooling min./max. °C 4/37

Clock Yesregulation function proportional bandpower supply Thermostat Voltage V Battery powered 3x aa-lrG (alkaline)

receiver Voltage V 230Frequency hz 50phase 1~

Connection Thermostat wirelessreceiver wired

maximum distance to receiver

indoor m approx.30moutdoor m approx.100m

wireD room ThermoSTaT ekrTwa

Dimensions unit height/width/Depth

mm 87/125/34

weight unit g 215outdoor temperature

Storage min./max. °C -20/60operation min./max. °C 0/50

Temperature setting range

heating min./max. °C 4/37Cooling min./max. °C 4/37

Clock Yesregulation function proportional bandpower supply Voltage V Battery powered 3* aa-lr6 (alkaline)Connection Type wired

Solar ConneCTion ekSolhwaV1

Dimensions unit heightxwidthxDepth mm 770x305x270weight unit kg 8operation range outdoor

temperaturemin.~max. °C 1~35

Sound pressure level

nom. dBa 27

Thermal performance

Zero loss collector efficiency η0 % -

power supply phase/Frequency/Voltage hz/V 1~/50/220-240power supply intake indoor unit

aCCeSSorY ekSr3pa

mounting on wallDimensions unit heightxwidthxDepth mm 332x230x145Thermal performance

Zero loss collector efficiency η0 % -

Control Type Digital temperature difference controller with plain text displaypower consumption w 2

Sensor Solar panel temperature sensor pt1000Storage tank sensor pTCreturn flow sensor pTCFeed temperature and flow sensor Voltage signal (3.5V DC)

power supply Frequency;Voltage hz;V /50/230

Solar ColleCTor ekSV26p ekSh26p

Dimensions unit heightxwidthxDepth mm 2,000x1,300x85 1,300x2,000x85weight unit kg 43Volume l 1.7 2.1Surface outer m² 2.601

aperture m² 2.364absorber m² 2.354

Coating micro-therm (absorption max.96%, emission ca. 5% +/-2%)absorber harp-shaped copper pipe register with laser-welded highly selective coated aluminium plateGlazing Single pane safety glass, transmission +/- 92%allowed roof angle

min.~max. ° 15~80

operating pressure

max. bar 6

Stand still temperature

max. °C 200

Thermal performance

Zero loss collector efficiency η0 % 78.7heat loss coefficient a1 w/m².k 4.270Temperature dependence of the heat loss coefficient a2

w/m².k² 0.0070

Thermal capacity kJ/k 6.5incident angle modifier

am at 50° 0.94

installed position Vertical horizontal

inDoor uniTS FwXV20aVeB FwXV15aVeB

heating capacity Total capacity nom. kw 2.0 1.5Cooling capacity Total capacity nom. kw 1.7 1.2

Sensible capacity

nom. kw 1.4 0.98

power input heating nom. kw 0.015 0.013Cooling nom. kw 0.015 0.013

Dimensions unit height/width/Depth

mm 600/700/210

weight unit kg 15piping connections

Drain/oD/inlet/outlet mm/inch 18/G 1/2/G 1/2

Sound pressure level

heating nom. dBa 29 19Cooling nom. dBa 29 19

power supply phase/Frequency/Voltage hz/V 1~/50/60/220-240/220

solAr connection

solAr collector

heAt pump convector

(1)Cooling: indoor temp. 27°CDB, 19°CwB; entering water temp. 7°C, water temperature rise 5k.(2)heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5k.

Page 43: The natural choice - szegedklima.hu

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Daikinproductsaredistributedby:

fsc

ECPEN12-724_P

Daikin’s unique position as a manufacturer of airconditioning equipment, compressors and refrigerantshasledtoitscloseinvolvementinenvironmentalissues.ForseveralyearsDaikinhashadtheintentiontobecomea leader in the provision of products that have limitedimpact on the environment. This challenge demandsthe eco design and development of a wide rangeof products and an energy management system,resulting in energy conservation and a reduction ofwaste.

ECPEN12-724_P

•xxxx•03/12•C

opyrightDaikin

Printedon

non

-chlorinated

pap

er.Prepa

redbyl

a m

ovid

a, Belgium

Resp.Ed.:D

aikinEurope

N.V.,Z

andvoo

rdestraat3

00,B-8400Oostend

e

Daikin Europe N.V. participates in the EuroventCertification programme for Air conditioners(AC), Liquid Chilling Packages (LCP) and Fan coilUnits (FCU), Check ongoing validity of certificateonline: www.eurovent-certification.com or using: www.certiflash.com

The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. hascompiledthecontentofthisleaflettothebestofitsknowledge.Noexpressorimpliedwarranty is given for the completeness, accuracy, reliability or fitnessforparticularpurposeof its content and theproducts and servicespresentedtherein.Specificationsaresubjecttochangewithoutpriornotice.DaikinEuropeN.V.explicitlyrejectsanyliabilityforanydirectorindirectdamage,inthebroadestsense,arisingfromorrelatedtotheuseand/orinterpretationofthisleaflet.AllcontentiscopyrightedbyDaikinEuropeN.V.

Daikin altherma is the market creator of the air-to-water heat pump business• firstinverter-drivensplitlow-temperatureheatpumpsystem• firstheatpumpsystemfortruehigh-temperatureapplications• first inverter-driven split heat pump system for apartment and

commercialapplications• full range of heating solutions for any kind of application, including

solar collectors, domestic hot water tanks, under-floor heating, heatpumpconvectoretc.

Daikin altherma is the reference on quality and reliability• 50yearsofheatpumpexperience• 6yearsofair-to-waterheatpumpexperience• Daikin Altherma is the most sold air-to-water heat pump system

throughoutEurope,withover150,000systemssold

a clean environmentIn producing your customer’s climate-control system, we strive forsustainable energy consumption, product recycling and waste reduction.Daikinrigorouslyappliestheprinciplesofeco-design,thusrestrictingtheuseofmaterialsthatareharmfultoourenvironment.

Daikin altherma

&Daikin in general

Daikin is known worldwide as one of the biggest aC players, with a wide product range for residential, commercial and industrial applications