CLIENT: ARISTONE DESIGNS, Inc. 1615 East Weber Drive Tempe, Arizona PROJECT DESCRIPTION AND ADDRESS: Structural Design of PRECAST CONCRETE COLUMNS Great State of Arizona GENERAL INFORMATION: BUILDING CODES: 2006 I.B.C. 2003 I.B.C. NOTES: FOR ADDITIONAL INFORMATION - SEE BASIS OF DESIGN. THE NELSON GROUP Job Name: Aristone - Column Design ENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 1 of 36 1136 EAST HARMONY AVE. SUITE 205 By: C.A.N. Date: 01.29.07 MESA, ARIZONA 85204 [480] 497-0003 FAX: [480] 497-0038 2006-BASIS.lwp PDF created with pdfFactory Pro trial version www.pdffactory.com

THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

  • Upload
    hadat

  • View
    221

  • Download
    5

Embed Size (px)

Citation preview

Page 1: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

CLIENT:

ARISTONE DESIGNS, Inc.

1615 East Weber Drive

Tempe, Arizona

PROJECT DESCRIPTION AND ADDRESS:

Structural Design of

PRECAST CONCRETE COLUMNS

Great State of Arizona

GENERAL INFORMATION:

BUILDING CODES:

2006 I.B.C.

2003 I.B.C.

NOTES:

FOR ADDITIONAL INFORMATION - SEE BASIS OF DESIGN.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 1 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.29.07MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-BASIS.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 2: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

TABLE OF CONTENTS

COVER SHEET - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1TABLE OF CONTENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2BASIS OF DESIGN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3COLUMN ‘CT-27’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5

COLUMN ‘CT-24’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

COLUMN ‘CT-21’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

COLUMN ‘CT-18’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14

COLUMN ‘CT-16’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

COLUMN ‘CT-13’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20

COLUMN ‘CT-11’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 23

COLUMN ‘CS-24’ [Round] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 26

COLUMN ‘CCF-21’ [Corinthian Fluted] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 28LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 28STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 29

COLUMN ‘CSQ-24’ [Square] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 31LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 31STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32

COLUMN ‘CSQ-18’ [Square] - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34LOAD TABLE & COLUMN SECTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34STRUCTURAL CALCULATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 2 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.29.07MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-BASIS.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 3: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

BASIS FOR DESIGN:

BUILDING CODE:• 2006 EDITION OF THE INTERNATIONAL BUILDING CODE.

• 2003 EDITION OF THE INTERNATIONAL BUILDING CODE

LOADS:• MAXIMUM VERTICAL POINT LOAD ALLOWED, TO BE DETERMINED DURING CALCULATIONS.

FOUNDATIONS:• TO BE DESIGNED BY THE STRUCTURAL ENGINEER OF RECORD FOR SPECIFIC PROJECTS.

CONCRETE: • MINIMUM 28 DAY STRENGTH = 3,000 P.S.I. EXCEPT AS FOLLOWS:

COLUMNS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4,000 p.s.i..

REINFORCING:• BARS #4 AND SMALLER: - - - - - - - - - - - - - - - - - - - - - - - - - FY = 40,000 P.S.I..

• BARS #5 AND LARGER: - - - - - - - - - - - - - - - - - - - - - - - - - - FY = 60,000 P.S.I..

INSERTS:• COIL LOOP INSERTS SHALL BE MANUFACTURED BY ‘DAYTON RICHMOND’ OR EQUIVALENT WITH

CURRENT ‘ICC’ EVALUATION REPORT.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 3 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.29.07MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-BASIS.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 4: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

30.0 kips 7.5 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

4 #7 VERTICAL REINFORCING

#3 TIES @ 8" O.C. [8" SQUARE]

PRECAST CONCRETECOLUMN

CONCRETE BASE

BY THE ENGINEER OF RECORD.

HEIGHT"H"

143 1/2" MAX.

2414"

20"

1718"

3/4"x 9" FLARED COILLOOP INSERT

4 #7 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

27"6"

12"

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

4

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 5: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-27’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 143 1/2” . . . . . . . . . . . . . USE 12’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 15” . . . . . . . . . . . . . . . . . . [Actual Dia. = 17.125” Minimum]

CONC. COVER . . . . . . . . . . 2.5” . . . . . . . . . . . . . . . . . [Actual Cover = 2.5” + 1.25” = 3.75”]

LOAD ECCENTRICITY . . . 6”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 30,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 30,000 # . . . . . . . . . . . . M1 = 7.5 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 5 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT27.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 6: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-27-12 [30.0k & 7.5k-f]] PG. 6 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 12.000 ft 4,000.0 40,000.0

4 1.000 2.400

psi

Rebar Percent 1.358 %LL & ST Loads Act SeparateSpiral Ties NOT Used

15.000 12.000 4

7

2.500

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 30.000 6.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 7.500k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 15.00in, with 4 #7 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 51.00 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

68.16 0.00 0.00 k

inin

M-critical 38.25 0.00 0.00 k-ftCombined Eccentricity 9.0000 0.0000 0.0000 inMagnification Factor 1.04 0.00 0.00Design Eccentricity 9.3737 0.0000 0.0000 in

39.84 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 550.94 550.94 550.94 kP : Balanced 241.74 241.74 241.74 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

5.1790 5.1790 5.1790 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 38.400 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 4.7175 19.7475 in 19.7475 ininPhi 0.7278 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 3,583.44 0.00 0.00Pc : pi^2 E I / (k Lu)^2 1,705.59 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0399 0.0000 0.0000Delta 1.0415 0.0000 0.0000Ecc: Ecc Loads + Moments 9.0000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 7: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

25.0 kips 5.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

24"

12"

2112"

HEIGHT"H"

119 3/4" MAX.

6"

1518"

18"

3/4"x 6" FLARED COILLOOP INSERT

4 #6 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

#3 TIES @ 8" O.C. [8" SQUARE]

4 #6 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

CONCRETE BASE

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

7

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 8: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-24’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 119 1/2” . . . . . . . . . . . . . USE 10’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 14” . . . . . . . . . . . . . . . . . . [Actual Dia. = 15.125” Minimum]

CONC. COVER . . . . . . . . . . 2.0” . . . . . . . . . . . . . . . . . [Actual Cover = 2.0” + .5” = 2.5”]

LOAD ECCENTRICITY . . . 6”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 25,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 25,000 # . . . . . . . . . . . . M1 = 5.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 8 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT24.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 9: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-24-10 [25.0k & 5.0k-f]] PG. 9 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 10.000 ft 4,000.0 40,000.0

4 1.000 1.760

psi

Rebar Percent 1.143 %LL & ST Loads Act SeparateSpiral Ties NOT Used

14.000 10.000 4

6

2.000

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 25.000 6.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 5.000k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 14.00in, with 4 #6 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 42.50 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

56.64 0.00 0.00 k

inin

M-critical 29.75 0.00 0.00 k-ftCombined Eccentricity 8.4000 0.0000 0.0000 inMagnification Factor 1.03 0.00 0.00Design Eccentricity 8.6634 0.0000 0.0000 in

30.68 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 470.24 470.24 470.24 kP : Balanced 217.62 217.62 217.62 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

4.5862 4.5862 4.5862 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 34.286 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 4.1270 18.7570 in 18.7570 ininPhi 0.7380 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 2,719.24 0.00 0.00Pc : pi^2 E I / (k Lu)^2 1,863.73 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0304 0.0000 0.0000Delta 1.0314 0.0000 0.0000Ecc: Ecc Loads + Moments 8.4000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 10: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

22.0 kips 2.5 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

16"

21"

14 1/2"

19"

3/4"x 6" FLARED COILLOOP INSERT

4 #5 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

#3 TIES @ 8" O.C. [8" SQUARE]

4 #5 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

6"

HEIGHT"H"

119 3/4" MAX.

12"

CONCRETE BASE

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

10

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 11: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-21’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 119 3/4” . . . . . . . . . . . . . USE 10’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 12.5” . . . . . . . . . . . . . . . . [Actual Dia. = 14.5” Minimum]

CONC. COVER . . . . . . . . . . 1.25” . . . . . . . . . . . . . . . . [Actual Cover = 1.25” + 1.0” = 2.25”]

LOAD ECCENTRICITY . . . 6”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 22,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 22,000 # . . . . . . . . . . . . M1 = 2.5 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 11 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT21.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 12: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-21-10 [22.0k & 2.5k-f]] PG. 12 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 10.000 ft 4,000.0 40,000.0

4 1.000 1.240

psi

Rebar Percent 1.010 %LL & ST Loads Act SeparateSpiral Ties NOT Used

12.500 10.000 4

5

1.250

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 22.000 6.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 2.500k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 12.50in, with 4 #5 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 37.40 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

44.63 0.00 0.00 k

inin

M-critical 22.95 0.00 0.00 k-ftCombined Eccentricity 7.3636 0.0000 0.0000 inMagnification Factor 1.04 0.00 0.00Design Eccentricity 7.6873 0.0000 0.0000 in

23.96 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 370.10 370.10 370.10 kP : Balanced 183.08 183.08 183.08 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

3.9044 3.9044 3.9044 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 38.400 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 3.4762 17.3462 in 17.3462 ininPhi 0.7404 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 1,728.12 0.00 0.00Pc : pi^2 E I / (k Lu)^2 1,184.44 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0421 0.0000 0.0000Delta 1.0440 0.0000 0.0000Ecc: Ecc Loads + Moments 7.3636 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 13: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

15.0 kips 2.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

1714"

1312"

12"

HEIGHT"H"

143 12" MAX.

12"

18"

4 5/8"

3/4"x 6" FLARED COIL LOOP INSERT

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[6" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C. [6" SQUARE]

PRECAST CONCRETECOLUMN

CONCRETE BASE

BY THE ENGINEER OF RECORD.

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

13

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 14: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-18’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 144” . . . . . . . . . . . . . . . . USE 12’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 10” . . . . . . . . . . . . . . . . . . [Actual Dia. = 12” Minimum]

CONC. COVER . . . . . . . . . . 1.25” . . . . . . . . . . . . . . . . [Actual Cover = 1.25” + 1” = 2.25”]

LOAD ECCENTRICITY . . . 4”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 15,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 15,000 # . . . . . . . . . . . . M1 = 2.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 14 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT18.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 15: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-18-12 [15.0k & 2.0k-f] PG 15 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 12.000 ft 4,000.0 40,000.0

4 1.000 0.800

psi

Rebar Percent 1.019 %LL & ST Loads Act SeparateSpiral Ties NOT Used

10.000 12.000 4

4

1.250

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 15.000 4.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 2.000k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 10.00in, with 4 #4 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 25.50 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

27.50 0.00 0.00 k

inin

M-critical 11.90 0.00 0.00 k-ftCombined Eccentricity 5.6000 0.0000 0.0000 inMagnification Factor 1.11 0.00 0.00Design Eccentricity 6.2286 0.0000 0.0000 in

13.24 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 237.05 237.05 237.05 kP : Balanced 113.68 113.68 113.68 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

3.1629 3.1629 3.1629 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 57.600 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 2.7950 13.3750 in 13.3750 ininPhi 0.7478 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 707.84 0.00 0.00Pc : pi^2 E I / (k Lu)^2 336.91 0.00 0.00alpha: MaxPu / (.75 Pc) 0.1009 0.0000 0.0000Delta 1.1122 0.0000 0.0000Ecc: Ecc Loads + Moments 5.6000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 16: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

10.0 kips 1.5 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

12"

10"

16"

HEIGHT"H"

95 1/2" MAX.

12"

1612"

3 3/4"

3/4"x 6" FLARED COILLOOP INSERT

4 #5 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[5" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

#3 TIES @ 8" O.C. [5" SQUARE]

4 #5 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

CONCRETE BASE

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

16

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 17: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-16’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 95 1/2”” . . . . . . . . . . . . . USE 8’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 8” . . . . . . . . . . . . . . . . . . . [Actual Dia. = 10” Minimum]

CONC. COVER . . . . . . . . . . 1.0” . . . . . . . . . . . . . . . . . [Actual Cover = 1.0” + 1.0” = 2.0”]

LOAD ECCENTRICITY . . . 3”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 10,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 10,000 # . . . . . . . . . . . . M1 = 1.5 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 17 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT16.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 18: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-16-8 [10.0k & 1.5k-f] PG 18 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 8.000 ft 4,000.0 40,000.0

4 1.000 0.800

psi

Rebar Percent 1.592 %LL & ST Loads Act SeparateSpiral Ties NOT Used

8.000 8.000 4

4

1.000

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 10.000 3.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 1.500k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 8.00in, with 4 #4 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 17.00 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

21.00 0.00 0.00 k

inin

M-critical 6.80 0.00 0.00 k-ftCombined Eccentricity 4.8000 0.0000 0.0000 inMagnification Factor 1.08 0.00 0.00Design Eccentricity 5.1780 0.0000 0.0000 in

7.34 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 160.15 160.15 160.15 kP : Balanced 72.26 72.26 72.26 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

2.8712 2.8712 2.8712 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 48.000 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 2.5640 10.7940 in 10.7940 ininPhi 0.7084 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 289.93 0.00 0.00Pc : pi^2 E I / (k Lu)^2 310.49 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0730 0.0000 0.0000Delta 1.0788 0.0000 0.0000Ecc: Ecc Loads + Moments 4.8000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 19: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

10.0 kips 1.5 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

1312"

13"

9"

514"

10"

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C. [5" SQUARE]

PRECAST CONCRETECOLUMN

CONCRETE BASE

3 3/4"

3/4"x 6" COIL LOOPINSERT

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[5" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

HEIGHT"H"

95 12" MAX.

12"

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

19

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 20: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-13’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 95½” . . . . . . . . . . . . . . . . USE 8’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 8.0” . . . . . . . . . . . . . . . . . [Actual Dia. = 9.0” Minimum]

CONC. COVER . . . . . . . . . . 1.0” . . . . . . . . . . . . . . . . . [Actual Cover = 1.0” + 0.5” = 1.5”]

LOAD ECCENTRICITY . . . 3”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 10,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 10,000 # . . . . . . . . . . . . M1 = 1.5 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 20 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT13.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 21: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-13-8 [10.0k & 1.5k-f] PG. 21 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 8.000 ft 4,000.0 40,000.0

4 1.000 0.800

psi

Rebar Percent 1.592 %LL & ST Loads Act SeparateSpiral Ties NOT Used

8.000 8.000 4

4

1.000

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 10.000 3.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 1.500k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 8.00in, with 4 #4 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 17.00 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

21.00 0.00 0.00 k

inin

M-critical 6.80 0.00 0.00 k-ftCombined Eccentricity 4.8000 0.0000 0.0000 inMagnification Factor 1.08 0.00 0.00Design Eccentricity 5.1780 0.0000 0.0000 in

7.34 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 160.15 160.15 160.15 kP : Balanced 72.26 72.26 72.26 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

2.8712 2.8712 2.8712 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 48.000 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 2.5640 10.7940 in 10.7940 ininPhi 0.7084 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 289.93 0.00 0.00Pc : pi^2 E I / (k Lu)^2 310.49 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0730 0.0000 0.0000Delta 1.0788 0.0000 0.0000Ecc: Ecc Loads + Moments 4.8000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 22: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

5.0 kips 1.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

934"

HEIGHT"H"

91 12" MAX.

8"

1612"

3"

3/4"x 6" FLARED COIL LOOP INSERT

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[4 1/8" SQUARE]

PRECAST CONCRETECOLUMN

16.5" EXTENSION OFVERTICAL REINFORCING.

4 #4 VERTICAL REINFORCING

#3 TIES @ 8" O.C. [4 1/8" SQUARE]

PRECAST CONCRETECOLUMN

6 3/4"

11"

412"

6" DIA. HOLE [FOR SHAFT REBAR]

CONCRETE BASE

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

22

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 23: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CT-11’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 71½” . . . . . . . . . . . . . . . . USE 7’-8”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 6.75” . . . . . . . . . . . . . . . . [Actual Dia. = 6.75” Minimum]

CONC. COVER . . . . . . . . . . 1.00” . . . . . . . . . . . . . . . . [Actual Cover = 1.00”]

LOAD ECCENTRICITY . . . 3”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 5,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 5,000 # . . . . . . . . . . . . . M1 = 1.5 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 23 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CT11.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 24: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CT-11-8 [5.0k & 1.5k-f] PG. 24 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 8.000 ft 4,000.0 40,000.0

4 1.000 0.800

psi

Rebar Percent 2.236 %LL & ST Loads Act SeparateSpiral Ties NOT Used

6.750 8.000 4

4

1.000

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 5.000 3.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 1.500k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 6.75in, with 4 #4 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 8.50 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

10.18 0.00 0.00 k

inin

M-critical 4.67 0.00 0.00 k-ftCombined Eccentricity 6.6000 0.0000 0.0000 inMagnification Factor 1.08 0.00 0.00Design Eccentricity 7.1122 0.0000 0.0000 in

5.04 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 120.76 120.76 120.76 kP : Balanced 49.59 49.59 49.59 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

2.7519 2.7519 2.7519 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 56.889 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 2.0334 8.9334 in 8.9334 ininPhi 0.7817 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 146.94 0.00 0.00Pc : pi^2 E I / (k Lu)^2 157.36 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0720 0.0000 0.0000Delta 1.0776 0.0000 0.0000Ecc: Ecc Loads + Moments 6.6000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 25: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

8"

2"

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

30.0 kips 7.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

24"

12"

HEIGHT"H"

96" MAX.

6"

#3 TIES @ 8" O.C. [8" SQUARE]

4 #7 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

CONCRETE BASE

3/4"x 6" FLARED COILLOOP INSERT

4 #7 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

17"

19"

24"

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

25

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 26: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CS-24’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 96” . . . . . . . . . . . . . . . . . . USE 8’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 15” . . . . . . . . . . . . . . . . . . [Actual Dia. = 17” Minimum]

CONC. COVER . . . . . . . . . . 2.5” . . . . . . . . . . . . . . . . . [Actual Cover = 2.5” + 1.5” = 3.5”]

LOAD ECCENTRICITY . . . 6”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 30,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 30,000 # . . . . . . . . . . . . M1 = 7.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 26 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CS24.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 27: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CS-24-8 [30.0k & 7.0k-f]] PG. 27 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 8.000 ft 4,000.0 40,000.0

4 1.000 2.400

psi

Rebar Percent 1.358 %LL & ST Loads Act SeparateSpiral Ties NOT Used

15.000 8.000 4

7

2.500

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 30.000 6.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 7.000k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 15.00in, with 4 #7 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 51.00 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

73.62 358.11 358.11 k

inin

M-critical 37.40 0.00 0.00 k-ftCombined Eccentricity 8.8000 0.0000 0.0000 inMagnification Factor 1.00 1.00 1.00Design Eccentricity 8.8000 0.0000 0.0000 in

37.40 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 550.94 550.94 550.94 kP : Balanced 241.74 241.74 241.74 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

5.1790 5.1790 5.1790 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 25.600 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 4.8975 19.7475 in 19.7475 ininPhi 0.7091 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 0.00 0.00 0.00Pc : pi^2 E I / (k Lu)^2 0.00 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0000 0.0000 0.0000Delta 1.0000 0.0000 0.0000Ecc: Ecc Loads + Moments 8.8000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 28: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT12"

2034"

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

15.0 kips 2.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

HEIGHT"H"

125 1/4" MAX.

21"

2312"

3/4"x 6" FLARED COILLOOP INSERT

4 #6 VERTICAL REINFORCING

#4 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" VOID FORVERTICAL REINFORCING.

1334"

1812"

934"

20 3/4" EXTENSION OFVERTICAL REINFORCING.

4 #6 VERTICAL REINFORCING

#4 TIES @ 8" O.C. [8" SQUARE]

PRECAST CONCRETECOLUMN

CONCRETE BASE

6"

1658"

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

28

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 29: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CCF-21’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 153.5” . . . . . . . . . . . . . . . USE 12’-9”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

DIA. [DESIGN] . . . . . . . . . . . 11.5” . . . . . . . . . . . . . . . . [Actual Dia. = 12.75” Minimum]

CONC. COVER . . . . . . . . . . 1.0” . . . . . . . . . . . . . . . . . [Actual Cover = 1.0” + 1.25” = 2.25”]

LOAD ECCENTRICITY . . . 4”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 15,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 15,000 # . . . . . . . . . . . . M1 = 2.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 29 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CCF21.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 30: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CCF-21-12 [15.0k & 2.0k-f]] PG. 30 of 36

Circular Concrete ColumnRev: 580002User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Total Height 12.750 ft 4,000.0 40,000.0

4 1.000 1.240

psi

Rebar Percent 1.194 %LL & ST Loads Act SeparateSpiral Ties NOT Used

11.500 12.750 4

5

1.000

f'cDiameter inFy Unbraced Length ft

psi

Seismic ZoneNumber of Bars

Column is BRACEDTotal Rebar Area in2Bar Size

Bar Cover in

Eff. Length Factor

Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

Loads

k 15.000 4.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink

k-ft 2.000k-ft

Applied Moments... @ Top k-ftk-ft @ Bottom k-ftk-ft

Summary

Column Diameter= 11.50in, with 4 #5 BarsColumn is OK

Applied Pu : Max Factored ACI C-1 ACI C-2 ACI C-3 25.50 0.00 0.00 kk

Allowable Pn * Phi @ Design Ecc.k

50.09 0.00 0.00 k

inin

M-critical 11.90 0.00 0.00 k-ftCombined Eccentricity 5.6000 0.0000 0.0000 inMagnification Factor 1.07 0.00 0.00Design Eccentricity 5.9902 0.0000 0.0000 in

12.73 k-ft 0.00 k-ft 0.00 k-ftMagnified Design MomentPo * 0.80 318.83 318.83 318.83 kP : Balanced 198.46 157.04 157.04 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

2.7266 3.7349 3.7349 in

Slenderness per ACI 318-02 Section 10.12 & 10.13

Actual k Lu / r 53.217 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 4.2957 16.2057 in 16.2057 ininPhi 0.6500 0.6500 0.6500Max Limit kl/r 34.0000 34.0000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 0.0000Cm 1.0000 1.0000 1.0000EI / 1000 1,238.02 0.00 0.00Pc : pi^2 E I / (k Lu)^2 521.97 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0651 0.0000 0.0000Delta 1.0697 0.0000 0.0000Ecc: Ecc Loads + Moments 5.6000 0.0000 0.0000 inDesign Ecc = Ecc * Delta 0.0000 0.0000 0.0000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 31: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

25.0 kips 10.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

24"

12"

6"

#3 TIES @ 8" O.C. [8" SQUARE]

4 #7 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

24"

18"

CONCRETE BASE

HEIGHT"H"

84" MAX.

3/4"x 6" FLARED COILLOOP INSERT

4 #7 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[8" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

31

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 32: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CSQ-24’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 84” . . . . . . . . . . . . . . . . . . USE 7’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

H = W [DESIGN] . . . . . . . . . 15” . . . . . . . . . . . . . . . . . . [Actual Dia. = 17” Minimum]

CONC. COVER . . . . . . . . . . 4.5” . . . . . . . . . . . . . . . . . [Actual Cover = 4.5” + 1.0” = 5.5”]

LOAD ECCENTRICITY . . . 6”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 25,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 25,000 # . . . . . . . . . . . . M1 = 10.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 32 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CSQ24.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 33: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CSQ-24-8 25.0k & 10.0k-ft] 33 of 36

Rectangular Concrete ColumnRev: 580003User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Width 4,000.0 40,000.0

2 1.000inDepth psi 15.000

15.000

- #

7.000

d = 2 7 4.500 2 7 10.500 in- #

f'cinFy Unbraced Length ft

psi Total Height 7.000 ft

Seismic ZoneRebar:ind =

Eff. Length FactorLL & ST Loads Act Together Column is BRACED

LoadsNote: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.

Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

0.000 25.000 6.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink k

10.000 10.000

Applied Moments... @ Top k-ftk-ft k-ft @ Bottom k-ftk-ft k-ft

Summary

15.00 x 15.00in Column, Rebar: 2-#7 @ 4.50in, 2-#7 @ 10.50in

Column is OK

Applied : Pu : Max Factored ACI C-1 ACI C-2 ACI C-3

42.50 31.88 0.00 kkAllowable : Pn * Phi @ Design Ecc.

k 74.49 74.49 168.94 k

inin

M-critical 38.25 28.69 0.00 k-ftCombined Eccentricity 10.800 10.800 6.000 inMagnification Factor 1.00 1.00 1.00Design Eccentricity 10.800 10.800 6.000 in

Po * .80 682.27 682.27 682.27 kP : Balanced 298.82 298.82 298.82 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

5.470 5.470 5.470 in

38.25 k-ft 28.69 k-ft 0.00 k-ftMagnified Design Moment

Slenderness per ACI 318-95 Section 10.12 & 10.13

Actual k Lu / r 18.667 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 3.8100 3.8100 in 6.4650 ininPhi 0.7581 0.7581 0.6500Max Limit kl/r 39.3333 39.3333 34.0000Beta = M:sustained/M:max 0.0000 0.0000 1.0000Cm 1.0000 1.0000 1.0000EI / 1000 0.00 0.00 0.00Pc : pi^2 E I / (k Lu)^2 0.00 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0000 0.0000 0.0000Delta 1.0000 1.0000 1.0000Ecc: Ecc Loads + Moments 10.800 10.800 6.000 inDesign Ecc = Ecc * Delta 10.800 10.800 6.000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 34: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

ACTUAL [H] MOMENT

ALLOWABLE LOADS

VERTICALDESIGN

HEIGHT

CONCRETE STRENGTH = 4,000 PSI.REINFORCING STRENGTH: Fy = 40,000 PSIALL CONCRETE SHALL BE VIBRATED DURINGPLACEMENT.REINFORCING SHALL BE RESTRAINED DURINGPLACEMENT OF CONCRETE.

CONNECTION AT TOP AND BOTTOM SHALL BESPECIFIED, ON CONSTRUCTION DOCUMENTS,

REINFORCING AND CONCRETE PLACEMENTSHALL CONFORM TO "ACI 318" SPECIFICATIONAND REQUIREMENTS.

ALL COLUMNS SHALL BE BRACED AGAINSTSIDESWAY.

A.

C.D.

F.

E.

G.

10.0 kips 5.0 ft-kips

COIL LOOP INSERTS SHALL BE MANUFACTUREDBY DAYTON RICHMOND OR EQUIVALENT.

H.

BUILDING CODES:

B.

I.

BY THE ENGINEER OF RECORD.

18"

12"

18"

HEIGHT"H"

84" MAX.

3/4"x 6" FLARED COILLOOP INSERT

4 #5 VERTICAL REINFORCING

#3 TIES @ 8" O.C.[6" SQUARE]

PRECAST CONCRETECOLUMN

12" EXTENSION OFVERTICAL REINFORCING.

12"

#3 TIES @ 6" O.C. [8" SQUARE]

4 #5 VERTICAL REINFORCING

PRECAST CONCRETECOLUMN

CONCRETE BASE

458"

OF

07-155JOB NO.

C.A.N.REV'D BY:

01.30.08DATE:

C.A.N.DRWN BY:

361615 East Weber DriveARISTONE DESIGNS, Inc.

Tempe, Arizona

34

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 35: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

COLUMN ‘CSQ-18’

GRAVITY LOADS:

• DESIGN VALUES:

LMAX . . . . . . . . . . . . . . . . . . . . . 84” . . . . . . . . . . . . . . . . . . USE 7’-0”

F’C . . . . . . . . . . . . . . . . . . . . . . 4,000 PSI

FY . . . . . . . . . . . . . . . . . . . . . . 40,000 PSI

H = W [DESIGN] . . . . . . . . . 10” . . . . . . . . . . . . . . . . . . [Actual Dia. = 11” Minimum]

CONC. COVER . . . . . . . . . . 3.25” . . . . . . . . . . . . . . . . [Actual Cover = 3.25” + 0.5” = 3.75”]

LOAD ECCENTRICITY . . . 4”

CONNECTIONS AT TOP AND BOTTOM OF COLUMN SHALL BE DETAILED BY DESIGNENGINEER.

• DESIGN LOADS:

P1 = 10,000 #

LOAD ARE ENTERED INTO THE DESIGN PROGRAM AS LIVE LOADS SO THAT THE HIGHERLOAD FACTOR OF 1.7 WOULD BE APPLIED TO LOADS. THIS PRODUCES A MORECONSERVATIVE DESIGN.

• ALLOWABLE MOMENTS: [DETERMINED FROM DESIGN PROGRAM RESULTS]

P1 = 10,000 # . . . . . . . . . . . . M1 = 5.0 ft-kips

REFER TO ATTACHED CALCULATIONS RESULTS FROM “ENERCALC” DESIGN PROGRAM FORADDITIONAL INFORMATION.

THE NELSON GROUP Job Name: Aristone - Column DesignENGINEERING & DEVELOPING, INC. Job No.: 2007-155 Sheet No.: 35 of 361136 EAST HARMONY AVE. � SUITE 205 By: C.A.N. Date: 01.30.08MESA, ARIZONA 85204[480] 497-0003 � FAX: [480] 497-0038

2006-CALC-CSQ18.lwp

PDF created with pdfFactory Pro trial version www.pdffactory.com

Page 36: THE NELSON GROUP Job Name: Aristone - Column Design ... · Structural Design of PRECAST CONCRETE COLUMNS ... PLACEMENT. REINFORCING SHALL BE ... 2006 IBC: Structural Design of Reinforced

The Nelson GroupEngineering & Developing, Inc.1136 East Harmony Ave., Ste 205Mesa, Arizona 85204

Description CSQ-18-8 10.0k & 5.0k-ft] 36 of 36

Rectangular Concrete ColumnRev: 580003User: KW-0603042, Ver 5.8.0, 1-Nov-2006(c)1983-2006 ENERCALC Engineering Software 07-155.ecw:Calculations

ARISTONE - COLUMN DESIGN 07-155C.A.N.

Scope :

Title : Job #

Description :Dsgnr: Date:

2006 IBC: Structural Design of Reinforced Concrete Columns

ARISTONE DESIGNS, Inc.1615 East Weber Drive

General Information Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000

Width 4,000.0 40,000.0

2 1.000inDepth psi 10.000

10.000

- #

7.000

d = 2 5 3.250 2 5 7.875 in- #

f'cinFy Unbraced Length ft

psi Total Height 7.000 ft

Seismic ZoneRebar:ind =

Eff. Length FactorLL & ST Loads Act Together Column is BRACED

LoadsNote: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design.

Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2

0.000 10.000 4.000Dead Load Live Load Short Term Eccentricity

Axial Loads k ink k

5.000 5.000

Applied Moments... @ Top k-ftk-ft k-ft @ Bottom k-ftk-ft k-ft

Summary

10.00 x 10.00in Column, Rebar: 2-#5 @ 3.25in, 2-#5 @ 7.88in

Column is OK

Applied : Pu : Max Factored ACI C-1 ACI C-2 ACI C-3

17.00 12.75 0.00 kkAllowable : Pn * Phi @ Design Ecc.

k 26.33 26.33 82.21 k

inin

M-critical 14.17 10.62 0.00 k-ftCombined Eccentricity 10.000 10.000 4.000 inMagnification Factor 1.00 1.00 1.00Design Eccentricity 10.000 10.000 4.000 in

Po * .80 308.31 308.31 308.31 kP : Balanced 150.44 150.44 150.44 kEcc : Balanced

kk

k-ftk-ftinin

inin

kkkk

3.504 3.504 3.504 in

14.17 k-ft 10.62 k-ft 0.00 k-ftMagnified Design Moment

Slenderness per ACI 318-95 Section 10.12 & 10.13

Actual k Lu / r 28.000 Elastic Modulus 3,605.0 ksi Beta 0.850ACI Eq. C-2ACI Eq. C-1 ACI Eq. C-3

Neutral Axis Distance 2.5350 2.5350 in 4.7250 ininPhi 0.7919 0.7919 0.6500Max Limit kl/r 41.2000 41.2000 34.0000Beta = M:sustained/M:max 0.0000 0.0000 1.0000Cm 1.0000 1.0000 1.0000EI / 1000 0.00 0.00 0.00Pc : pi^2 E I / (k Lu)^2 0.00 0.00 0.00alpha: MaxPu / (.75 Pc) 0.0000 0.0000 0.0000Delta 1.0000 1.0000 1.0000Ecc: Ecc Loads + Moments 10.000 10.000 4.000 inDesign Ecc = Ecc * Delta 10.000 10.000 4.000 in

ACI Factors 1.400 1.700 1.700 1.100

0.750 0.900 1.300

1.400 0.900

(per ACI 318-02, applied internally to entered loads)

ACI C-1 & C-2 DLACI C-1 & C-2 LLACI C-1 & C-2 ST

....seismic = ST * :

ACI C-2 Group FactorACI C-3 Dead Load FactorACI C-3 Short Term Factor

Add''l "1.4" Factor for SeismicAdd''l "0.9" Factor for Seismic

PDF created with pdfFactory Pro trial version www.pdffactory.com