Sterile Processing Department/Endoscopy
One Integrated Approach to Healthcare.
VERIFY® RESI-TEST™ SWAB Cleaning Indicator
CERTAINTYTHE POWER OF
Quick, Easy, CleanVERIFY® RESI-TEST™ SLIDE-THRU Cleaning Indicator
Manual cleaning confirmation
has never been so easy for all
your medical devices.
Whether it’s checking
the exterior or lumen of a
device, you can quickly and
accurately confirm if residual
protein soils are present after
the cleaning process.
VERIFY YOUR PROCESSThere is no room for error in your daily process. With just a few swipes or a gentle tug, combined with a quick shake, VERIFY RESI-TEST Cleaning Indicators are tailored to detect the most difficult to clean soils - proteins.
Fast spot check for hard to clean instruments and devices
Ease of Use Productivity
Seamlessly incorporate into your existing process
Reduces interpretation failure with an easy to see color change to see if residual protein soils are present after cleaning
With the potential for transmission of infectious organisms on the rise, closely following standards becomes paramount. ANSI/AAMI standards indicate a need for more than a visual inspection after manual cleaning.
PRESENCE OF PROTEIN Proteins can remain on devices after improper manual cleaning.
Since protein is present in all procedural soils, and a component of most other soils (carbohydrates, lipids, etc), it is the most appropriate marker in cleaning verification. RESI-TEST Cleaning Indicators test down to 1µg of protein, lower than the industry guideline of 6.4 μg*/cm2.
“…methods that are able to measure organic residues that are not detectable using visual inspection should be considered in facility cleaning policy and procedures”– ANSI/AAMI ST91:2015
Proteins are not water soluble so they are a challenging soil to remove
*AAMI/ANSI ST91:2015
Contact your STERIS representative or visit steris.com/ResiTest to learn more.
5960 Heisley RoadMentor, OH 44060-1834 • USA440-354-2600 • 800-548-4873www.steris.com
M9068EN.2019.11 Rev. B©2019 STERISAll rights reserved.
VERIFY RESI-TEST SWAB CLEANING INDICATOR• Swab accommodates both surfaces
and the hard-to-clean tip of devices
• Only requires a swab of a surface,
snap of the tube and a quick shake
LCC 100 100 TestsLCC101 25 Tests (5 Controls)
2D79QH Large, 2.8-5.0mm ID/ 290cm Length 100 brushes
2D74QH Medium, 1.5-2.6mm ID/ 220cm Length 100 brushes
2D73QH Small, 1.0-1.2mm ID/ 150cm Length 100 brushes
VERIFY RESI-TEST SLIDE-THRU CLEANING INDICATOR• Three sizes available to properly fit most lumened
devices
• Just slide through internal channels, clip end into
test tube and wait for results
Easy to read results in less than 10 seconds