73
1

the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

1

Page 2: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

Findersat is a dynamic presence in the production and distribution of electronics and electrical products.

It comes as a natural development of the finders company founded in 1990 and is a decisive step in gaining a leading position in the relevant market. Findersat "meets" the digital age and envisions a dynamic future. Utilizing the experience of old executives and investing in the knowledge and freshness

of the younger, it aspires to be a reference brand in the category of products it produces and distributes. The integrated program for the production, amplification and transmission of digital TV signals, adapted to the digital age and the "Greek product" stamp, is enriched with new products that meet modern

market demands. The ambition and aspirations of its founders is to establish its presence in the field of electrical products. Producing also, the central heating panel, which already enjoys the confidence of the technical world, the company implements an ambitious program of production and distribution of

electrical products. The modern facilities in the Industrial Area of Greece Ioannina, the quality control of the produced products, the specialization of the executives and the quality of the services provided, maintain the relationship of trust with the market and strengthens the hope for further development.

2 the company

Page 3: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

the relationship with our clients

Findersat's clients are its core capital. Maintaining the relationship of trust between the company and its

customers is a constant pursuit of the company's executives. The complete program of production, transport and amplification of the TV signal, the top quality of the

products, the well-organized commercial department and the complete administrative organization, create the conditions to have only satisfied customers.

The management and executive staff of Findersat promise consistent commitment to continuous improvement of products and services.

relationship with our clients 3

Page 4: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

index

1 mast amplifiers 5

2 central amplifiers 13

3 linear – line amplifiers – pro amplifiers 20

4 socket – aerial mixers – splitters 25

5 TV antennas 32

6 accessories – connections components 41

7 coaxial cables – special cables 46

8 modulators 53

9 support components 55

10 satellite components 60

11 panels for autonomy of central heating 67

4 index

Page 5: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

1. mast amplifiers

index

mast amplifiers 5

Type Page

F232SP 6

F226SP 7

F2U26SP 8

F126SP 9

FD234SP 10

FD134SP 11

TR1 12

TR2 12

TR3 12

Page 6: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 1 UHF input

and splitter

TYPE F232 SP

Inputs RF UHF

Max gain dB 32

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 104

Consumption mA 50

Operating Voltage VDC 12

supplier with 2 outputs

Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

packing

F232SP

1 piece mm 180X140X50

weight Kg 0.380

Enables you install a 3rd TV (TV3), with external cable via the incorporated splitter, avoiding the use of the cable inside the house.

application example

6 mast amplifiers

Page 7: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 1 UHF input

and splitter

TYPE F226 SP

Inputs RF UHF

Max gain dB 26

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 104

Consumption mA 50

Operating Voltage VDC 12

supplier with 2 outputs

Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

packing

1 piece mm 180X140X50

weight Kg 0.380

F226SP

Enables you install a 3rd TV (TV3), with external cable via the incorporated splitter, avoiding the use of the cable inside the house.

application example

mast amplifiers 7

Page 8: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 2 inputs (UHF-UHF)

and splitter

TYPE F2U26 SP

Input RF UHF UHF

Max Gain dB 26 26

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 96

Consumption mA 40

Operating Voltage VDC 12

supplier with 2 outputs

Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

packing

F2U26SP

1 piece mm 180X140X50

weight Kg 0.380

Enables you install a 3rd TV (TV3), with external cable via the incorporated splitter, avoiding the use of the cable inside the house.

application example

8 mast amplifiers

Page 9: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 1 UHF/VHF log input

and splitter

TYPE F126 SP

input RF UHF/VHF

Max gain dB 26

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 104

Consumption mA 40

Operating Voltage VDC 12

supplier with 2 outputs

Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

F126SP packing

1 piece mm 180X140X50

weight Kg 0.380

The amplifier has the same V/U input and accepts the signal from the VHF/UHF antennas, mainly logarithmic. With two different adjustable attenuators enables you adjust the signal VHF or UHF, when needed. Enables you also install a 3rd TV (TV3), via the incorporateted splitter, without passing the cable through the house.

application example

mast amplifiers 9

Page 10: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

shielded amplifier with 1 input

and splitter

TYPE FD234 SP

Input RF UHF

Max gain dB 34

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 104

Consumption mA 50

Operating Voltage VDC 12

supplier with 2 outputs

Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

F234SP packing

1 piece mm 155X60X235

weight Kg 0.650

With metallic cover and F ends . Each packing contains also the male F connectors needed for the connections. For

the convenience of the installer, the amplifier can be easily removed from the plastic box and be put back after

the connections. Enables you also install a 3rd TV (TV3) , via the incorporated splitter, without passing the cable

through the house.

application example

10 mast amplifiers

Page 11: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

shielded amplifier with 1 input

and splitter

TYPE FD134 SP

Input RF UHF/VHF

Max gain dB 34

Regulation gain dB 0-15

Noise figure dB ‹ 4

Output level dBμV 104

Consumption mA 50

Operating Voltage VDC 12

supplier with 2 outputs

FD134SP Mains supply VAC 220-230

Output voltage VDC 12±5%

Consumption mA 83

packing

1 piece mm 155X60X235

weight Kg 0.650

With metallic cover and F ends. Each packing contains also the male F connectors needed for the connections. For

the convenience of the installer, the amplifier can be easily removed from the plastic box and be put back after the

connections. The amplifier has the same V/U input and accepts the signal from the VHF/UHF antennas, mainly

logarithmic. With two different adjustable attenuators enables you adjust the signal VHF or UHF, when needed.

Enables you also install a 3rd TV (TV3) , via the incorporateted splitter, without passing the cable through the

house.

application example

mast amplifiers 11

Page 12: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

Suppliers +12VDC findersat

TR1 TR2 TR3

application example

12 mast amplifiers

TYPE TR1 TR2 TR3

Main supply VAC 220-230 220-230 220-230

Output voltage VDC +12(±5%) +12(±5%) +12(±5%)

Maximum current mA 83 83 83

Number of RF outputs 2 2 2

Input loss dB ≤5 ≤5 ≤5

Maximum consumption W 2,5 2,5 2,5

Dimensions mm 105Χ65Χ40 122Χ77Χ42 95Χ133Χ40

Page 13: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

2. central amplifiers

index

central amplifiers 13

TYPE page

FR1 14

FR1-2U 15

FR3 16

FR4 17

FK7 18

FK8 19

Page 14: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 2 inputs (series FR)

TYPE FR1

RF input VHF - UHF

Gain dB 24 - 26

Regulation dB 0-15

Noise figure dB ‹ 5

Output for pre amplifier

Output level RF dBμV 112

Main supply VAC 220-230

Consumption mA 70

Dimensions mm 130X47X250

packing

FR1

1 piece mm 145X55X285

16 pieces mm 290X300X470

weight 1 piece weight 16 pieces

Kg 0.75 12.00

suggestions for central installations

14 central amplifiers

Page 15: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 3 inputs (series FR)

TYPE FR1-2U

RF inputs VHF-UHF-UHF

Gain dB 24- 26- 26

Regulation dB 0-15

Noise figure dB ‹ 5

Output for pre amplifier VDC +18

Output level RF dBμV 112

Main supply VAC 220-230

Consumption mA 70

Dimensions mm 130X47X250

packing

FR1-2U

1 piece mm 145X55X285

16 pieces mm 290Χ300Χ470

weight 1 piece weight 16 pieces

Kg 0,75 12,00

suggestions for central installations

central amplifiers 15

Page 16: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 3 inputs (series FR)

ΤΥΠΟΣ FR3-800MHZ

RF inputs FM-VHF-UHF

Gain dB 32-32-34

Regulation dB 0-15

Noise figure dB ≤ 5

Output for pre amplifier VDC +18

Output level RF dBμV 116

Main supply VAC 220-230

Consumption mA 90

Dimensions mm 265X47X130

packing

FR3-800MHZ

1 piece mm 280X55X145

16 pieces mm 290X47X130

weight 1 piece weight 16 pieces

Kg 0.75 12.00

suggestions for central installations

16 central amplifiers

Page 17: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 4 inputs (series FR)

TYPE FR4

RF inputs FM-VHF-UHF-

UHF

Gain dB 32-32-34-34

Regulation dB 0-15

Noise figure dB ‹ 5

Output for pre amplifier VDC +18

Output level RF dBμV 116

Main supply VAC 220-230

Consumption mA 90

Dimensions mm 265X47X130

packing

FR4

1 piece mm 280X55X145

16 pieces mm 290X300X470

weight 1 piece weight 16 pieces

Kg 0.75 12.00

suggestions for central installations

central amplifiers 17

Page 18: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 1 input V/U (series FK)

TYPE FK7

RF input VHF/ UHF

Gain dB 28 32

Regulation dB 0-15

Noise figure dB ‹ 5

Output for pre amplifier VDC

Output level RF dBμV 112

Main supply VAC 220-230

Consumption mA 50

Dimensions mm 205X55X120

Packing

FK7

suggestions for central installations

18 central amplifiers

1 piece mm 220X55X145

20 pieces mm 290X300X470

weight 1 piece weight 20 piece

Kg 0.65 13.00

Page 19: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

amplifier with 3 inputs (series FK)

packing

FK8

1 piece mm 220X55X145

20 pieces mm 290X300X470

weight 1 piece

weight 20 pieces

Kg 0.65

13.00

suggestions for central installations

central amplifiers 19

TYPE FK8

RF inputs VHF-UHF-UHF

Gain dB 30 30 30

Regulation dB 0-15

Noise figure dB ‹ 5

Output for pre amplifier VDC

Output level RF dBμV 112

Main supply VAC 220-230

Consumption mA 70

Dimensions mm 205X55X120

Page 20: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

3. linear – line amplifiers

pre amplifiers

Index

TYPE page

FP128 21

FL126 23

F112 24

20 linear – line amplifiers – pre amplifiers

Page 21: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

Linear

TYPE FP 128

RF inputs FM/VHF/UHF

Gain dB 12

Regulation dB

Noise figure dB ≤4

Output for pre amplifier VDC

Output level RF dBμV 128

Main supply VAC 220-230

Consumption mA 220

Dimensions mm 130X47X265

packing

1 piece mm 145X55X285

16 pieces mm 290X300X470

weight 1 piece weight 16 pieces

Kg 0.75 12

FP128

application example

linear – line amplifiers – pre amplifiers 21

Page 22: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

diagram of central installation using linear FP 128

The installation includes 192 sockets divided for each apartment in 4 sectors, with 3 pass sockets and 1 terminal

socket in every sector. The same installation could also function using terminal sockets and a splitter ¼ in the beginning of each sector.

22 linear – line amplifiers – pre amplifiers

Page 23: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

line amplifier

packing

FL 126

application example

linear – line amplifiers – pre amplifiers 23

TYPE FL 126

RF inputs VHF - UHF

Gain dB 22 - 24

Regulation dB 0-15

Noise figure dB ≤5

Output for pre amplifier VDC

Output level RF dBμV 96

Main supply VAC 220-230

Consumption W 2.3

Dimensions mm 95Χ133Χ40

1 piece mm 107Χ135Χ52

44 pieces mm 290X300X470

weight 1 piece weight 44 pieces

Kg 0.28 12.5

Page 24: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

pre amplifier

TYPE F112

RF input UHF

Gain dB 12

Regulation dB

Noise figure dB ≤4

Output for pre amplifier VDC

Output level RF dBμV 90

Main supply VDC +18

Consumption mA 7

Dimensions mm 60X40

F112

application example

24 linear – line amplifiers – pre amplifiers

Page 25: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

4. sockets – aerial mixers

splitters

index

sockets – aerial mixers - splitters 25

TYPE page

DIEL 26

TER 26

DIEL-S 26

TER-S 26

MIXVU 27

MIXVUU 27

MIXVUU-SP 27

FSP16 28

FSP18 29

DFD12 30

DFD13 30

DFD14 30

DFD16 31

DFD18 31

Page 26: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

thought pass socket TV-RD

TYPE DIEL

Frequency range MHz 5 - 862

Transit loss dB 2,5

output loss (±0,5dB) to TV to RD

dB 7,5 20,5

cover YES

terminal socket TV-RD

DIEL - TER

TYPE TER

Frequency range MHz 5 - 862

Output loss to TV to RD

dB ≤3,5 ≤10

cover YES

For use in networks with columns, star splitters or complicated systems. Cast main part, very resistant, designed to be installed in a typical electrolocical box of 56mm diameter.

thought pass TV-RD-SAT

terminal socket TV-RD-SAT

DIEL-S / TER-S

TYPE TER-S

Frequency range TV RD SAT

MHz 5-68/120-862 87-108

950-2150

Transit loss (±0,5dB) to TV to RD to SAT

dB ≤1 ≤1,5 ≤2

cover YES

transferred DC via SAT output

YES

For use in networks with columns, star splitters or complicated systems. Cast main part , very resistant, designed to be installed in a typical electrolocical box of 56mm diameter.

26 sockets – aerial mixers - splitters

TYPE DIEL-S

Frequency range TV

RD SAT

MHz 5-68/120-862

87-108 950-2150

Transit loss TV RD

SAT

dB 1 1

4

Output loss (±0,5dB) to TV to RD to SAT

dB 11.5 11.5 10

cover YES

transferred DC via SAT output

YES

Page 27: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

mast aerial mixers

TYPE ΜΙΧ VU MIX VUU MIX VU-SP

Frequency range MHz 5-862 5-862

RF inputs V - U V - U - U

Transit loss dB 1 1.5 1 2 2

packing

1 piece 44 pieces

mm 52X107X131 290/400/470

52X107X131 290/400/470

52X107X131 290/400/470

weight 1 piece weight 44 pieces

kg 0.35 15,5

0.35 15,5

0.35 15,5

MIXVU MIXVUU MIXVU-SP

application example

sockets – aerial mixers - splitters 27

Page 28: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

mast aerial mixers

TYPE FSP 16

Frequency range MHz 5-900

Number of outputs 2

Transit loss dB 4

Transit voltage DC YES

packing

1 piece 44 pieces

mm 52/107/131 290/300/470

weight 1 piece

weight 44 pieces

Kg 0,35

15,5

FSP16

application example

Combining the splitter FSP16 and a mast amplifier of the SP series

28 sockets – aerial mixers - splitters

Page 29: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

mast aerial mixers

TYPE FSP 18

Frequency range MHz 5-900

Number of outputs 3

Transit loss dB 6

Transit voltage DC YES

packing

1 piece 44 pieces

mm 52/107/131 290/300/470

weight 1 piece 44 pieces

Kg 0,35 15,5

FSP18

application example

Combining the splitter FSP18 and a mast amplifier of the SP series

sockets – aerial mixers - splitters 29

Page 30: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

shielded F- type splitters

TYPE DFD12 DFD13 DFD14

Frequency range MHz 5-2500 5-2500 5-2500

Branch loss dB 4 6 8

Transit voltage DC YES YES YES

Metal protection box YES YES YES

DFD12 DFD13 DFD14

Splitters suitable for central installations with strong metal protection box and F ends. Their packing includes also components for the placement. They allow transit voltage.

application example

30 sockets – aerial mixers - splitters

Page 31: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

shielded F- type splitters

TYPE DFD16 DFD18

Frequency range MHz 5-2500 5-2500

Branch loss dB 12 15

Transit voltage DC YES YES

Metal protection box YES YES

DFD16 DFD18

Splitters suitable for central installations with strong metal protection box and F ends. Their packing includes also components for the placement. They allow transit voltage.

application example

sockets – aerial mixers - splitters 31

Page 32: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

5. TV antennas

index

TYPE page

UB60 33

R20 34

R20-P 34

R50 35

GBII 36

GBI 36

UP6 36

T320 37

T360 37

PR20 38

PR4 39

PR6 39

PR12 39

LOG14 40

LOG16 40

32 TV antennas

Page 33: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

UB series

TYPE channels gain

dB

parts relation

Ε/Ο(dB)

horizontal

angle

vertical

angle

length

mm

packing

pieces

UB60 21-69 15 48 27 40° 45° 1180 5

UB60

UHF wide band antennas. The main part is constructed of square shaped aluminum profile , dimensions 15.7x 15.7 mm, and the rest parts of circular shaped aluminum ,diameter 5mm . The rest elements are already assembled to the central part. All types have transformer adaptor and metal parts from galvanized steel. As reflector is used aluminum grating. Separately packed, in dual colored cardboard box.

Gain curves

TV antennas 33

Page 34: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

R series

R20 R20-P

UHF wide band antennas. The main part is constructed of square shaped aluminum profile , dimensions 15.7x 15.7 mm, and the rest parts of aluminum ,dimensions 6x7 mm . The elements are already assembled to the central part. All types have transformer adaptor and metal parts from galvanized steel. As reflector is used aluminum grating. Separately packed , in dual colored cardboard box.

Gain curves

34 TV antennas

TYPE channels gain dB

parts relation Ε/Ο(dB)

horizontal angle

vertical angle

length

packing pieces

R20 21-69 6.0 8 26 40° 45° 33 2

R20-P 21-69 18 8 26 40° 45° 33 2

Page 35: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

R series

TYPE channels gain

dB

parts relation

Ε/Ο(dB)

horizontal

angle

vertical

angle

length

mm

packing

pieces

R50 21-69 16.5 52 30 38° 41° 1020 5

R100 21-69 17.5 100 32 28° 30° 2350 5

R50 R100

UHF wide band antennas. The main part is constructed of square shaped aluminum profile , dimensions 15.7x 15.7 mm, and the rest parts of aluminum ,dimensions 6x7 mm . The elements are already assembled to the central part. All types have transformer adaptor and metal parts from galvanized steel. As reflector is used aluminum dish, diameter 440 mm . Separately packed , in dual colored cardboard box.

Gain curves

TV antennas 35

Page 36: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

PANEL series

TYPE channels gain dB

parts relation Ε/Ο(dB)

horizontal angle

vertical angle

length/width mm

packing pieces

GBII 21-69 14.5 20 45° 24° 840/640 6

GBI 21-69 14 18 52° 27° 840/640 8

UP6 21-69 12,5 20 45° 26° 810/540 8

GBII G BI UP6

UHF PANEL type antennas. The main part is constructed of square shaped aluminum profile, dimensions 15.7x 15.7 mm, and the rest parts of solid aluminum, cutting 4 mm . The type GBII, has directive parts and is packed separately in four colored cardboard box. All types have transformer adaptor and metal parts from galvanized steel. As reflector, is used aluminum grating, dimensions 840x 640 mm (types GBII and GBI) and wire grating (type UP6).

Gain curves

36 TV antennas

Page 37: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

T series

TYPE channels gain

dB

parts relation

Ε/Ο(dB)

horizontal

angle

vertical

angle

length

mm

packing

pieces

T320 21-60 14.5 41 23 40° 45° 1150 6

T360 21-60 16 56 30 32° 36° 1450 5

T320 T360

Broadband UHF Antennas. The main part is made of 15,7 x 15,7 mm square aluminum profiles, and solid aluminum elements with a cross section of Φ 6 mm. All types have an adapter transformer and the metal parts are made of galvanized steel. Reflector uses an aluminum grill. They are delivered assembled.

Gain curves

MHz CHAN.

TV antennas 37

Page 38: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

PR series

TYPE Channels gain

dB

parts relation

Ε/Ο(dB)

horizontal

angle

vertical

angle

length

mm

packing

pieces

PR20 21-60 15 25 22 36° 45° 1215 12

PR20

UHF wide band antennas. The main part is constructed of square shaped aluminum profile , dimensions 15.7x 15.7 mm, and the rest parts of solid aluminum ,cutting 6 mm. All types have transformer adaptor and metal parts from galvanized steel. As reflector, is used aluminum grating. Dispatched fully assembled.

Gain curves

38 TV antennas

Page 39: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

PR series

TYPE channels gain dB

parts relation Ε/Ο(dB)

horizontal angle

vertical angle

length mm

packing pieces

PR4 21-60 10,5 8 16 46° 40° 490 50

PR6 21-60 12.0 11 17 44° 42° 800 30

PR12 21-60 13,5 15 20 40° 43° 1220 20

PR4 PR6 PR12

UHF wide band antennas. The main part is constructed of square shaped aluminum profile , dimensions 15.7x 15.7 mm, and the rest parts of solid aluminum, cutting 6 mm. All types have transformer adaptor and metal parts from galvanized steel. As reflector, is used aluminum grating. Dispatched fully assembled.

Gain curves

TV antennas 39

Page 40: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

TV antennas

LOG series

TYPE channels gain

dB

parts relation

Ε/Ο(dB)

horizontal

angle

vertical

angle

length

mm

packing

pieces

LOG14 21-69 11.3 28 28 30° 36° 1040 14

LOG16 5-69 10.2/11.3 32 26 32° 36° 1200 10

LOG14 LOG16

LOG 14: UHF logarithmic antenna. The main part is constructed of square shaped aluminum profile, dimensions 15.7x 15.7 mm, and the rest parts of solid aluminum, cutting 4 mm. LOG 16: VHF-UHF logarithmic antenna. The main part is constructed of square shaped aluminum profile, dimensions 15.7x 15.7 mm, and the rest parts of solid aluminum, cutting 4 mm. Both types have transformer adaptor and metal parts from galvanized steel. For the cable connection bear F connectors. The proper F connector is included.

Gain curves

40 TV antennas

Page 41: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

6. various accessories

components for connections

index

various accessories – components for connections 41

TYPE page TYPE page

FAS 42 0122 44

FTHS 42 0123 44

FAG 42 0452 44

FTHG 42 HDMI/1.5 45

T 42 HDMI/2 45

FFA 42 3122 45

MFF 42 3199 45

MFTH 42 1312 45

AFVT 42

FFAG 42

TF 42

R75 43

R75F 43

M/S-U 43

M/S-V 43

M/S-US 43

0120 43

0117 43

1001 44

1002 44

1003 44

0336 44

0337 44

Page 42: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

connectors for coaxial cables

T female /male /female

FAS – FTHS FAG - FTHG T Male connector Angular male connector T female/male/ female

Female connector Angular female connector

F connectors for coaxial cables

F joints

adaptor F/ female connector

T F connector

TYPE FFA MFF MFTH AFVT FFAG TF

Frequency range MHz 0-2400 0-2400 0-2400 0-2400 0-2400 0-2400

External cable diameter max

min

mm 7

6.7

Central conductor diameter max min

mm 1.3 0.8

1.3 0.8

1.3 0.8

1.3 0.8

Dimensions (diameter/length) mm 11/19 12/23 11/21 12/27 9/25 9.5/41

Number of pieces 100 50 50 50 50 50

FFA MFF MFTH AFVT FFAG TF

Male F connector joint F joint F adaptor F/ angular male F T F connector male - male female - female connector female connector

42 various accessories – components for connections

TYPE FAS FTHS FAG FTHG T

External cable diameter max

min

mm 7

5

7

5

7

5

8

5

Central conductor diameter max min

mm 1.8 0.5

1.8 0.5

1.5 0.5

1.5 0.5

Dimensions (diameter/length) mm 16/46 16/46 9.5/25 30

packing Τεμ. 100 100 100 100 50

colour WHITE WHITE WHITE WHITE WHITE

Page 43: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

terminal resistors

TYPE R75 R75F

resistor Ω 75 75

application general F

Dimensions (diameter/length ) mm 5/18 12/14

R75 R75F

transformer adaptors

TYPE M/S-U M/S-V M/S-US

Input channel UHF VHF UHF

Dimensions (diameter/length ) mm 50/32.5 50/32.5 67/41

Ends type SCREW COLLAR

SCREW COLLAR

SCREW COLLAR

M/S-U M/S-V M/S-US

SCART components

TYPE 0120 0117

Connection SCART

female-female

SCART

3RCA/VHS

Dimensions mm 55X60 55X60

Switch YES

0120 0117

various accessories – components for connections 43

Page 44: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

connection cables

TYPE 1001 1002 1003 0336 0337

Cable Coaxial Coaxial Coaxial

Ends type Male -

female

Male -

male

Male -

female

SCART

SCART

SCART

SCART

Length m 1,5 1,5 3 1.5 5

1001-1002-1003 0336-0337

connection cables

0122 0123 0452

44 various accessories – components for connections

TYPE 0122 0123 0452

cable

Ends type SCART male 2 « female

SCART male 3 « female

SCART male 4 RCA

Length m 0.35 0.35 1,5

Switch YES

Page 45: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

connection cables

TYPE HDMI/1.5 HDMI/2 3122

Cable

Ends type 24KGold pl. 24KGold pl. 2RCA male 2RCA male

Length m 1.5 2.00 1,5

HDMI/1.5 – HDMI/2 3122

supply cables 220 V

TYPE 3199 1312

cable 2X0.75 3X1

Connector type Bipolar 220V 8 type

SUKO 220V triangle

length m 1.50 1.80

3199 1312

various accessories – components for connections 45

Page 46: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

7. coaxial cables

special cables

index

46 coaxial cables - special cables

TYPE page

MICROSAT 3.6mm 47

DIGISAT122 47

DIGISAT 123 47

SAT 423 47

DIGISAT 822 47

PROSAT 2CU 47

DIGISAT 823 48

DIGISAT 5 ELITE 48

INSAT 110 48

SILVER 48

RG 213U 48

10/45 49

10/96 49

UTP5 (M&P) 50

FTP5 (M&P) 50

UTP6 (M&P) 50

FTP6 (M&P) 50

UTP5(GMT) 51

UTP5 (GMT) 51

FTP5 (GMT) 51

UTP6 (GMT) 51

CCTV 1+2X0.50 52

TR2X0.50 52

TR2X0.75 52

TR2X1 52

TR2X1.5 52

BR2X0.5 52

BR2X0.75 52

BR2X1 52

BR2X1.5 52

AL4X0.22 52

AL6X0.22 52

Page 47: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

coaxial cables Messi & Paoloni

TYPE

MICROSAT

3.6mm

DIGISAT

122

DIGISAT

123

SAT 423 DIGISAT

822

PROSAT

2CU

inner conductor(material/diameter) mm CCS/0.41 Cu/0.8 Cu/0.8 Cu/1.0 Cu/1.1 Cu/1.1

physical expansion dielectric(diam.) mm±0.1 1,9 3.5 3.5 4.6 4.85 4.70

jacket (diameter ) mm±0.2 3,6 5.0 5 6.5 6.8 6.8

minimum bending radius mm 15 20 20 30 35 30

nominal impedance Ohm±3 75 75 75 75 75 75

attenuation at 20° C 5 MHz dB/100m 3,5 1.3 1.3 1.3 1.2 1.2

50 MHz dB/100m 9,8 5.5 5.5 4.5 4.0 3.9

200 MHz dB/100m 19,7 10.6 10.8 8.5 6.5 6.6

470 MHz dB/100m 31,0 16.9 16.7 13.3 11.9 11.7

860 MHz dB/100m 42,9 23.6 23.1 19.1 17.4 17.0

1000 MHz dB/100m 46,6 25.6 25.1 20.9 19.0 18.8

1750 MHz dB/100m 64,5 34.4 33.6 28.5 26.1 25.8

2050 MHz dB/100m 69,7 37.5 36.8 31.6 28.7 28.3

2150 MHz dB/100m 71,3 38.2 37.5 32.1 29.4 29.1

2400 MHz dB/100m 75,4 40.5 39.7 34.5 31.3 31.0

3000 MHz dB/100m 84,3 45.4 44.8 39.0 35.3 34.8

tension test of the jacket KV 4,0 4.0 4.0 4.0 4.0 4.0

packing coils/drums m 100 150/500 150/500 100/500 100/500 100/500

All the cables are constructed with the most sophisticated technology according to the European requirements, with reference to norms: CEI 100-7(TV reception installations ) EN 50117-5 (cable networks)- CEI 2052

coaxial cables - special cables 47

Page 48: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

coaxial cables messi & paoloni

All the cables are constructed with the most sophisticated technology according to the European requirements, with reference to norms: CEI 100-7(TV reception installations ) EN 50117-5 (cable networks)- CEI 2052

48 coaxial cables - special cables

TYPE DIGISAT

823 ELITE

DIGISAT

5 ELITE

IN SAT

110ELITE

SILVER RG

213U

MND

650

inner conductor(material/diameter) mm Cu/1.1 Cu/1.16 Cu/1.16 Cu/1.1 Cu/7x0.75 CCS/1.02

physical expansion dielectric(diam.) mm±0.1 4.85 5.0 5.0 4.80 7.25 4.60

jacket (diameter) mm±0.2 6.6 6.8 6.9 6.70 10.2 6.6

minimum bending radius mm 35 35 80 35 60 30

nominal impedance Ohm±3 75 75 75 75 50 75

attenuation at 20°C 5 MHz dB/100m 1.2 1.0 1.0 1.2 3.4

50 MHz dB/100m 4.0 3.6 3.6 4.0 4.3 5.9

200 MHz dB/100m 7.3 6.6 6.6 7.3 9.4 8.5

470 MHz dB/100m 12.0 11.0 11.0 12.0 (400) 13.8 13.0

860 MHz dB/100m 16.8 15.6 15.6 16.8 (800)20.4 18.5

1000 MHz dB/100m 18.2 17.0 17.0 18.2 20.0

1750 MHz dB/100m 24.8 23.3 23.3 24.8 27.0

2050 MHz dB/100m 27.2 25.6 25.6 27.2 29.7

2150 MHz dB/100m 27.9 26.2 26.2 27.9 30.5

2400 MHz dB/100m 29.6 27.8 27.8 29.4 32.5

3000 MHz dB/100m 33.5 31.6 31.6 33.2 37.0

tension test of the jacket KV 4.0 4.0 6.0 4.0 4.4 4.0

packing coils/drums m 100/500 100/500 100/500 100/500 500 100/500

for the use of underground facilities

YES

Page 49: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

coaxial cables CCS

All the cables are constructed with the most sophisticated technology according to the European requirements, with reference to norms: EN 50117-1: 2002 (EN 50289-1-6)

coaxial cables - special cables 49

TYPE

10/45 10/96

inner conductor(material/diameter) mm CCS/1.00 CCS/1.1

physical expansion dielectric(diam.) mm±0.1 4.6 4.8

jacket (diameter ) mm±0.2 6.6 6.8

minimum bending radius mm 30 33

nominal impedance Ohm±3 75 75

attenuation at 20°C 5 MHz dB/100m 1.4 1.2

50 MHz dB/100m 4.5 4.0

200 MHz dB/100m 8.8 6.7

470 MHz dB/100m 13.5 12.0

860 MHz dB/100m 19.5 18

1000 MHz dB/100m 21.2 20

1750 MHz dB/100m 29.0 26.3

2050 MHz dB/100m 32.0 29.0

2150 MHz dB/100m 32.5 31

2400 MHz dB/100m 35.5 31.9

3000 MHz dB/100m 42.0 36.2

tension test of the jacket KV 4.0 4.0

packing coils/drums m 100/500 100/500

Page 50: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

UTP - FTP cables messi & paoloni

TYPE CAT.5/E

UTP FTP

CAT.6

UTP FTP

conductor ( nom. diameter) 24 AWG 24 AWG 23 AWG 23 AWG

insulation mm ‹ 1 ‹ 1 ‹ 1.1 ‹ 1.1

no. couples 4 4 4 4

drain wires NAI NAI

jacket (material- diameter ) PVC/LSZH-5.4 PVC/LSZH-6.5 PVC/LSZH-7.0 PVC/LSZH-7.2

nominal impedance 0-100MHz Ohm 100±15% 100±15% 100±15% 100±15%

100-250MHz 100±22% 100±22%

NEXT PSNEXT PSELFEXT ATTEN NEXT PSNEXT PSELFEXT ATTEN

Loss 1MHz dB/100m 65.3 62.3 63.8 2.1 66.0 64.0 64.8 2.1

10 MHz dB/100m 50.3 47.3 43.8 6.5 59.3 57.3 44.8 6.0

16 MHz dB/100m 47.3 44.4 39.7 8.2 56.2 54.2 40.7 7.6

31.25 MHz dB/100m 42.9 39.9 33.9 11.7 51.9 49.9 34.9 10.7

62.5 MHz dB/100m 38.4 35.4 27.8 17.0 47.4 45.4 28.9 15.5

100 MHz dB/100m 35.3 32.3 23.8 22.0 44.3 42.3 24.8 19.9

150 MHz dB/100m 41.4 39.4 21.0 25.3

200 MHz dB/100m 39.8 37.8 18.8 29.2

250 MHz dB/100m 38.3 36.3 16.8 33.0

packing m 305 305 305 305

All the cables are constructed with the most sophisticated technology according to the European requirements, with reference to norms: ISO/IEC 11801 - EN 50173 – EIA/TIA568 B2

50 coaxial cables - special cables

Page 51: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

cables UTP - FTP GMT

TYPE CAT.5/E

UTP FTP

CAT.6

UTP

conductor (nom. diameter) mm 0.55 0.55 0.55

insulation mm ‹ 1 ‹ 1 ‹ 1.1

no. couples 4 4 4

drain wires NAI

jacket (material- diameter) PVC/LSZH-5.1 PVC/LSZH-5.5 PVC/LSZH-6.20

nominal impedance 0-100MHz Ohm 100±18% 100±18% 100±18%

100-250MHz 100±25%

NEXT PSNEXT PSELFEXT ATTEN NEXT PSNEXT

loss 1MHz dB/100m 65.8 62.8 64.0 2.4 66.9 64.4

10 MHz dB/100m 51.0 48.0 44.2 6.7 60.0 57.8

16 MHz dB/100m 47.9 44.8 40.2 8.5 56.6 54.3

31.25 MHz dB/100m 43.5 40.3 34.3 12.0 52.2 50.3

62.5 MHz dB/100m 39.0 35.8 28.2 17.3 47.5 45.6

100 MHz dB/100m 35.9 32.7 24.3 22.2 44.7 42.5

150 MHz dB/100m 41.6 39.7

200 MHz dB/100m 40.2 38.0

250 MHz dB/100m 38.6 36.5

packing m 305 305 305

All the cables are constructed with the most sophisticated technology according to the European requirements, with reference to norms: EN 61000-6-3: 2007 / EN 61000-6-1 :2007

coaxial cables - special cables 51

Page 52: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

CCTV - alarm - speaker cables

²

CCTV TR BR AL AL

speaker cables

TYPE TRANSPARENT (TR)

2X0.50 2X0.75 2X1.0 2X1.5

BLACK - RED (BR)

2X0.50 2X0.75 2X1.0 2X1.5

cable cut mm² 2x0.50 2x0.75 2x1.0 2x1.5 2x0.50 2x0.75 2x1.0 2x1.5

complicated impedance Ohm/KM ‹ 35 ‹ 24 ‹ 17 ‹ 12.5 ‹ 35 ‹ 24 ‹ 17 ‹ 12.5

colour TRANSP. TRANSP. TRANSP. TRANSP. BLACK RED

BLACK RED

BLACK RED

BLACK RED

packing m 100 100 100 100 100 100 100 100

CCTV – alarm cables

TYPE CCTV 1+2X0.50 AL4X0.22 AL6X0.22

cable cut mm² 1 Mini RG59 + 2X0.50 4X0.22 6X0.22

complicated impedance Ohm±3 75 (RG59)

shield AL Foil AL Foil AL Foil

colour WHITE WHITE WHITE

packing m 100/300 100 100

52 coaxial cables - special cables

Page 53: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

8. modulators

index

modulators 53

TYPE page

MOD 54

MOD5-12 54

MOD21-69 54

Page 54: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

RF modulators

TYPE MOD MS2169

RF outputs 2-4/5-12/21-69 21-69

Output signal level dBμV 70±3 75±4

Output resistance Ohm 75 75

Input Α 3RCA-AV input 3RCA-AV input

Input Β 75 Ohm ant.in. 75 Ohm ant.in.

S – VIDEO input Mini din 4 pins

Supply voltage VAC 220-230 220-230

MOD MOD5-12 MS2169

application example

54 modulators

Page 55: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

9. support components

index

TYPE page

IG-P 56

IG-V 56

I-AL 56

ZIS 56

ZIL 56

VI 56

SIR 56

AI 56

DB1 57

VT5 57

VT10 57

VT25 57

VT40 57

VT50 57

VT70 57

VTG20 58

VTG30 58

VTG45 58

VKD 58

VKD120 58

VKG 58

VKG120 58

VKTD 59

DT1500A 59

DBU165 59

DBU300 59

GB6060 59

DTB60 59

support components 55

Page 56: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

masts - mast base

wire rope - clamps

IG-P IG-V I-AL ZIS ZIL SIR AI VI

drawings – dimensions

IG-P

ZIS ZIL

I IG-V

VI

I-AL

56 support components

TYPE IG-P IG-V I-AL ZIS ZIL VI SIR AI

item lenght mm 1400 1400 1100 1100

1350 110 140

external diameter / thickness mm 38/1.0 42/1.0 37/1.0 33/1.0

41/1.5 48/1.3 3.00

blade cut mm 30X3

clamp opening mm 50 50

thread mm 8 8

items set 3 3 3

packing m/item 10 10 10 25 25 10 500 10

Page 57: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

wall – floor mounts

TYPE DB1 VT5 VT10 VT25 VT40 VT50 VT70

blade cut mm 28X2.5 40X4 40X4 40X4 40X4 40X4

pad dimensions mm 175X105

support of antenna /satellite ANT. ANT. ANT. ANT. ANT. ANT. ANT.

placed on wall/floor WALL WALL WALL WALL WALL WALL WALL

distance from the wall mm 35 40 100 250 400 500 700 clamp opening mm 65 55 65 65 65 65 65

pieces set 2 2 2 2

packing 10 10 10 5 5 5 5

DB1 VT5 VT10 VT25 - 40 - 50 - 70

drawings – dimensions

DB1

VT5

support components 57

Page 58: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

wall – floor mounts

TYPE VTG20 VTG35 VTG45 VKD VKD120 VKG VKG120

external diam./thickness mm 42X1.8 42X1.8 42X1.8 48Χ2 60Χ2 48Χ2 60Χ2

Height mm 250 250 250 650 750 300 300

Placed on wall/floor WALL WALL WALL FLOOR FLOOR WALL WALL

Support of anten. /satellite ANT. ANT. ANT. SAT. SAT. SAT. SAT.

Pad dimensions mm 105Χ120 105Χ120 105Χ120 (3)40Χ4 (3)40Χ4 115Χ190 190Χ190

Clamp opening/thread mm 67/8 67/8 67/8

Distance from the wall mm 200 350 450 320 500

packing item 5 5 5 5 5 5 5

VTG20 – 30 – 45 VKD – VKD120 VKG – VKG120

drawings – dimensions

VKG

VKD120

VKG

VTG20-35-45 120

VKD

58 support components

Page 59: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

wall – floor mounts

TYPE VKTD DT1500A DBU165 DBU300 GB6060 DTB60

external diam./thickness mm 42/1,8 42/1,8 42/1,8 42/1,8 60/1,8 42/1,8

height mm 460 600 290 290 600 600

Placed on wall/floor WALL/FLOOR WALL/FLOOR WALL WALL FLOOR FLOOR

Support of anten. /satellite SAT SAT ANT/SAT ANT/SAT SAT SAT

Pad dimensions mm 160Χ120 105Χ175 105Χ175 120Χ120 150Χ150

Clamp opening/thread mm

Distance from the wall mm 460 250 240 325 320 500

packing items 5 5 10 10 5 5

VKTD DT1500A DBU165 – 300 GB6060 DTB60

drawings – dimensions

VKTD DT1500A DBU165

DBU300 GB6060 DTB60

support components 59

Page 60: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

10. satellite installations

index

TYPE page

S70 61

S80 61

S90 61

S110 61

LNBI 62

LNBII 62

LNB QUAD 62

LNB QUATRO 62

MS0504 63

MS0508 63

MS0512 63

MS0516 63

MS0904 63

MS0908 63

MS0912 63

MS0916 63

SATYCON 64

EDISION HD 64

DS2/1 65

DS4/1 65

DS2/1PL 65

DS4/1PL 65

MIXSAT/TV 65

SF 66

V2LNB 66

V3LNB 66

60 satellite installations

Page 61: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

satellite dishes

TYPE S70 S80 S90 S110

dish type OFSET OFSET OFSET OFSET

offset angle ° 28 26 28 26

Reception frequency GHz 10.7-12.7 10.7-12.7 10.7-12.7 10.7-12.7

gain dB 35-37 37-38 38-39.7 40.6-42.8

material Galvanized steel

Finish coal Double polyester powder coating

colour RAL 7035 RAL 7035 RAL 7035 RAL 7035

Small axis diameter mm 600 700 800 1000

Long axis diameter mm 660 780 900 1100

LNB place mm 23-40 23-40 23-40 23-40

S70-80-90-110

application example

satellite installations 61

Page 62: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

LNB

TYPE LNB I LNB II LNB QUAD LNB QUATRO

input (low band) GHz 10.7-11.7 10.7-11.7 10.7-11.7 10.7-11.7

(high band) GHz 11.7-12.75 11.7-12.75 11.7-12.75 11.7-12.75

output (low band) MHz 950-1950 950-1950 950-1950

(high band) MHz 1100-2150 1100-2150 1100-2150

noise figure high/low dB 0.2 0.2 0.2 0.3

feed fitting diameter mm 40 40 40 40

connection only with multiswitch YES

LNB I LNB II LNB QUAD LNB QUATRO

application example

62 satellite installations

Page 63: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

multiswitches

TYPE MS0504 MS0508 MS0512 MS0516 MS0904 MS0908 MS0912 MS0916

number of SAT inputs 4 4 4 4 8 8 8 8

number of SAT outputs-subscribers

4 8 12 16 4 8 12 16

satel. band frequency MHz 950-2300 950-2300 950-2300 950-2300 950-2300 950-2300 950-2300 950-2300

terr. band frequency MHz 5-862 5-862 5-862 5-862 5-862 5-862 5-862 5-862

satel. inputs regulation dB 0-15 0-15 0-15 0-15 0-15 0-15 0-15 0-15

sat. output level dBμV 80 80 80 80 80 80 80 80

network voltage 50Hz VAC 220-230 220-230 220-230 220-230 220-230 220-230 220-230 220-230

maximum consumption VA 22 22 22 22 45 45 45 45

max. current to LNB mA 600 600 600 600 1400 1400 1600 1600

MS-0508 MS-0908

application example

satellite installations 63

Page 64: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

satellite receivers

TYPE SATYCON EDISION HD

input frequency MHz 950-2150 950-2150

incorporated reader

number of channels 4000 4000

EPG programme guide YES YES

TELETEXT support YES YES

diseq support C1.2 1.2 13/18V

reception SCPC/MCPC FULL HD

greek language menu YES YES

supply voltage VAC 220-230 220-230

dimensions mm 260Χ150Χ50 220Χ150Χ45

EDISION HD SATYCON F1FTA

application example

64 satellite installations

Page 65: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

DisEgc – mix SAT/TV

TYPE DS 2/1 DS 4/1 DS2/1 PL DS 4/1 PL MIXSAT/TV

satellite frequency MHz 900-2400 900-2400 850-2250 850-2250 950-2500

terrestrial frequency MHz 0,15-862

maximum troughpass current mA 500 500 500 500 500

number of LNB I inputs 2 4 2 4

outward placement YES YES

noise dB 3 3 3 3

DS 2/1 DS 4/1 DS4/1 PL MIX SAT/TV

application example

satellite installations 65

Page 66: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

LNB holders

satellite finder

TYPE SF V2LNB V3LNB

frequency range GHz 0.95-2.15

Gain dB 11-15

sensitivity dB 7

Supply voltage VDC 13-18

dimensions mm 62X110

SF V2LNB V3LNB

application example

V2LNB

66 satellite installations

Page 67: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

11. central heating

autonomy panel

index

TYPE page

F8-8K 68

F8S-1K 68

F8S-4K 68

F8D-1K 68

central heating autonomy panels 67

Page 68: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

central heating autonomy panels

Series F8-8K F8S-1K F8S-4K F8D-1K

box Metallic Metallic Metallic metallic

dimensions (1-8 timers) mm 200X290X110 200X290X110 200X290X110 200X290X110

dimensions (9-16 timers) mm 340X290X110 340X290X110 340X290X110 340X290X110

with relay YES YES YES

with diodes YES

with 1 circulator YES YES

with 2 to 4 circulators YES

with 1 to 8 circulators YES

thermal expansion YES YES

maximum current A 5 5 5 5

οperating voltage VAC 220-230 220-230 220-230 220-230

timer lock YES YES YES YES

SERIES DESCRIPTION

F8-8K With relay and possibility of connection of 1 to 8 circulators. The assignment of compartments - circulators is done by the installer, with bridges on a terminal block, according to instructions contained. With this design, it is possible to minimize

the STOK warehouse and fully customize the table in any installation. For example, a 6-hour clock table (F6-6K) can be connected to 6-compartment installations, with 1,2,3 ... up to 6 circulators and any partitioning of compartments per pump. It is connected to electric valves or circulators only. It does not provide automatic thermal expansion.

F8S-1K With relay and possibility of connection to installations with electric valves and 1 circulator. It provides automatic thermal

expansion in the installation, leaving the last electrovalve open and the pump running. No thermal measurement is performed during the thermal expansion operation. The thermal expansion process is controlled by the pump's hydrostatic valve, with a preset (≈ 50 ° C) set by the installer.

F8S-4K With relay and possibility of connection to installations with electric valves and 2 to 4 circulators. The pairing of compartments per pump is done by the manufacturer. It provides automatic thermal expansion to the plant, leaving the last electrovalve open and the last pump running. No thermal measurement is performed during the thermal expansion operation. The thermal expansion process is controlled by the pump's hydrostatic valve, with a preset (≈ 50 ° C) set by the

installer. It can be connected to installations with electric valves and circulators or only with circulators (if there is a 1 compartment per pump).

F8D-1K With passageways and connection capability to installations with electric valves and 1 circulator. It does not provide automatic thermal expansion in the installation.

68 central heating autonomy panels

Page 69: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

typology

F8-8K series

APARTMENTS CIRCULATORS

1 2 3 4 5 6 7 8

2 F2-1K F2-2K

3 F3-1K F3-2K F3-3K

4 F4-1K F4-2K F4-3K F4-4K

5 F5-1K F5-2K F5-3K F5-4K F5-5K

6 F6-1K F6-2K F6-3K F6-4K F6-5K F6-6K

7 F7-1K F7-2K F7-3K F7-4K F7-5K F7-6K F7-7K

8 F8-1K F8-2K F8-3K F8-4K F8-5K F8-6K F8-7K F8-8K

F8S-1K series

APARTMENTS 1 CIRCULATORS

2 F2S-1K

3 F3S-1K

4 F4S-1K

5 F5S-1K

6 F6S-1K

7 F7S-1K

8 F8S-1K

9 F9S-1K

F8S-4K series

APARTMENTS CIRCULATORS

2 3 4

2 F2S-2K

3 F3S-2K F3S-3K

4 F4S-2K F4S-3K F4S-4K

5 F5S-2K F5S-3K F5S-4K

6 F6S-2K F6S-3K F6S-4K

7 F7S-2K F7S-3K F7S-4K

8 F8S-2K F8S-3K F8S-4K

9 F9S-2K F9S-3K F9S-4K

10 F10S-2K F10S-3K F10S-4K

F8D-1K series

APARTMENTS 1 CIRCULATORS

2 F2D-1K

3 F3D-1K

4 F4D-1K

5 F5D-1K

6 F6D-1K

7 F7D-1K

8 F8D-1K

9 F9D-1K

10 F10D-1K

11 F11D-1K

central heating autonomy panels 69

Page 70: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

notes

notes 77

Page 71: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

notes

78 notes

Page 72: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

notes

notes 79

Page 73: the relationship with our clients · 2018. 5. 4. · FP128 application example linear – line amplifiers – pre amplifiers 21 . diagram of central installation using linear FP 128

notes

80 notes